• 제목/요약/키워드: Hollow Fiber Type Module

검색결과 14건 처리시간 0.022초

기체분리막에 의해 상승된 산소농도가 스파크점화기관의 연소에 미치는 영향 (The effects of oxygen-concentration increased by oxygen-enriching membrane on combustion of S.I. engines)

  • 권병철;김형섭
    • 오토저널
    • /
    • 제14권6호
    • /
    • pp.74-80
    • /
    • 1992
  • The purpose of this study is to improve the performance of gasoline engine. Combustion-characteristics orignated from supplying cylinder with fuel-air mixture which was formed by the rise of oxygen-concentration in air with oxygen-enriching membrane have been investigated. The results showed that the poor-limit of oxygen-concentration was increased by shortening combustion-duration because the rise of oxygen-concentration in fuel-air mixture resulted in the promotion of combustion-velocity. Also, the generation of large output of power was expected from combustion in proportion as the amount of oxygen was increased.

  • PDF

한외여과막을 이용한 단백질 정련액으로부터 단백질 분리 (Separation of Protein from Degumming Solution by Utrafiltration Membrane)

  • 김인철;이규호;박주영;정보름;권자영;이기훈
    • 멤브레인
    • /
    • 제17권4호
    • /
    • pp.375-380
    • /
    • 2007
  • 실크 생산공정 중 발생하는 부산물인 세리신을 회수하기 위하여 제조된 폴리에테르술폰 중공사 한외여과 모듈을 운전하였다. 부산물에 함유되어 있는 비누를 염화칼슘을 이용하여 침진시킨 후 침전된 비누가 함유된 세리신 용액의 침지형 및 가압형 모듈 운전 시 막오염 거동을 살펴보았다. 또한 가압형 모듈 운전 시 비누와 단백질이 막오염에 미치는 영향을 조사하였다. 비누를 제거함으로써 막오염이 줄어드는 경향을 보였다. 이로부터 비누가 침전될 때와 침전되기 전에 단백질 상호간에 영향을 끼치며 분리막에도 영향을 미침을 보여주고 있다.

응집·한외여과 조합공정에서 플럭스와 선속도가 막오염에 미치는 영향에 관한 연구 (A Study on Membrane Fouling by Flux and Linear Velocity in Coagulation/Ultrafiltration Membrane System)

  • 문성용;이상협;김승현;윤조희
    • 상하수도학회지
    • /
    • 제19권4호
    • /
    • pp.429-436
    • /
    • 2005
  • A coagulation/ultrafiltration membrane hybrid system was operated to treat river water with capacity of $0.06m^3/d$. The impact on membrane fouling by flux and linear velocity was investigated. It is known that pressure increase is proportional to flux increase. However, pressure increase was much faster than theoretical value in the pilot plant test. So it was suggested that flux was on important factor in ultrafiltration of continuous operation. Membrane fouling was decreased when linear velocity was increased. This phenomenon was found more obviously without coagulation. With the combination of coagulation and sedimentation, membrane fouling was not reduced conspicuously. Big particles formed during coagulation and sedimentation were destroyed by feed and circulation pumping, which resulted in little effect on membrane fouling reduction. The degree of destruction was similar at various linear velocities. In this study, the hollow fiber membrane was used and the system was operated in pressure type module. In case of the system used in this study, membrane fouling has been affected lightly by linear velocity variation when coagulation pretreatment was applied.

막 손상 측정을 위한 압력손실시험의 감도에 영향을 미치는 인자 (Influencing Factors on Sensitivity of Pressure Decay Test for Membrane Damage Assessment)

  • 이용수;김형수;김종오
    • 멤브레인
    • /
    • 제27권4호
    • /
    • pp.367-373
    • /
    • 2017
  • 중공사형 정밀여과(MF)와 한외여과(UF)를 포함한 가압식 막여과 시스템은 높은 수준의 병원균 제거 효율로 인해 음용수 처리에 점점 더 많이 사용되고 있다. 그러나 가압식 막여과 시스템에서 분리막의 손상으로 인한 막완결성의 문제가 발생시 병원체가 유출될 수 있으므로, 효과적인 온라인 또는 오프라인 방식의 막 완결성 모니터링 방법을 통해 수질의 안정성을 보장하여야 한다. 최근 막 완결성 시험 중 하나 인 압력손실시험(pressure decay test, PDT)이 가압식 분리막 모듈을 이용한 음용수 처리 시설에 적용되고 있다. 이 논문에서는 PDT의 기체 주입방법에 따른 세 가지 조건으로 원수 측, 여과수 측, 원수 여과수 양방향 측 세 가지 조건을 선정 후 이에 따른 감지감도를 이론값과 실험값을 적용하여 비교하였다. 실험결과 가압되는 측의 부피와 감도는 반비례함을 확인하였고, 주입부의 반대방향에 부압을 형성 시에도 감도가 증가함을 확인할 수 있다. 즉 막 손상의 감지감도는 주입되는 부분의 체적이 작아질수록, 분리막을 경계로 유입과 여과 측의 압력차가 클수록 높아짐을 알 수 있었다.