• Title/Summary/Keyword: Hole density

Search Result 442, Processing Time 0.025 seconds

Variation in Properties of Seawater Flooded and Non-Flooded CSPE (해수범람 전·후의 CSPE 특성변화)

  • Lee, Jeong-U;Kim, In-Yong;Ji, Seong-Hyun;Jeon, Hwang-Hyun;Shin, Yong-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.12
    • /
    • pp.1724-1729
    • /
    • 2015
  • Chlorosulfonated polyethylene (CSPE) was not flooded seawater and flooded seawater & freshwater for 5 days, respectively, and these samples are referred to as BSF(before seawater flooding) and ASFF(after seawater & freshwater flooding), respectively. The apparent density, dissipation factor, relative permittivity, melting temperature, dielectric breakdown time and increased time of applied voltage are higher than those of BSF, but the insulating resistance, dielectric strength, percent elongation and glass transition temperature of ASFF are lower than those of BSF. The differential temperature of those is $0.026{\sim}0.028(^{\circ}C)$ after AC and DC voltage is applied to ASFF, respectively, and the differential temperature of those is $0.013{\sim}0.037(^{\circ}C)$ after AC and DC voltage is applied to BSF, respectively. In the case AC and DC voltage is applied to ASFF as well as BSF, the variations in temperature of AC voltage are higher than those of DC voltage. It is investigated that dielectric loss due to dissipation factor ($tan{\delta}$) is related to electric dipole conduction current. It is certain that the ionic (electron or hole) leakage current was increased by conducting ions such as $Na^+$, $Cl^-$, $Mg^{2+}$, $SO_4^{2-}$, $Ca^{2+}$ and $K^+$, those are related to cured atoms of O and S that relatively increased after seawater flooding.

A Study on the Image Quality and Patient Dose in Erect Simple Abdomen Radiography (복부 선자세 단순촬영시 화질과 피폭선량에 관한 연구)

  • Kim, Jung-Min;Hayashi, Taro;Ishida, Yuji;Sakurai, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.21 no.1
    • /
    • pp.29-34
    • /
    • 1998
  • The purpose of simple abdomen erect projection is to see the fluid level which indicates gastrointestinal ileus or free air due to perforation. we do not have to insist on low kVp technique in simple abdomen erect position as long as we can detect the fluid level and free air shadow. Therefore, the author tried to decrease patient dose by high kVp technique and to improve the image quality due to motion artifact by reduction of exposure time. [Methods] Experiment 1. * screen/film SRO1000/HRH * exposure factor : $140\;kvp{\pm}5\;kv$ with added filters, 200 mA, 0.01 sec * phantom : Acryles : 15.0 cm(equivalent to 17 cm body thickness) 17.5 cm(equivalent to 21 cm body thickness) 20.0 cm (equivalent to 25 cm body thickness) With the exposure factor for same film density($D=0.8{\pm}0.1$) and with the materials above, we tried to find out entrance skin dose and gonad dose for both male and female. Experiment 2. Burger's phantom radiography were checked to see whether there was any change of image quality according to the kVp and the added filters. Experiment 3. Using rotating meter(self made), we examined the motion artifact and the exposure time limitation. [Results and conculution] 1. Using high voltage technique of 140 kVp with added filter, Skin dose, testicle dose and ovary dose decrease to 89.3%, 47% and 71.4% respectively compare to 70 kVp technique, 2. No great changes of Burger's phantom image has detected as from 70 kVp to 140 kVp and the air hole size of Burger's phantom over 0.028 cc(Diameter 3 mm, hight 4 mm) can be distinghished. 3. 0.01 sec(1 pulse) exposure time is possible in the single phase full wave rectification that why we can quitely reduce the unsharness caused by patient's movement.

  • PDF

자화 유도 결합 플라즈마의 산화물 건식 식각 특성에 관한 연구

  • Jeong, Hui-Un;Kim, Hyeok;Lee, U-Hyeon;Kim, Ji-Won;Hwang, Gi-Ung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.230-230
    • /
    • 2013
  • 플라즈마를 활용한 미세 패턴의 건식 식각은 반도체 소자 공정에 있어서 가장 중요한 기술 중 하나이다. 한편, 매년 발행되는 ITRS Roadmap 에 따르면 DRAM 의 1/2 pitch 는 감소하는 동시에 Contact A/R (Aspect Ratio) 는 증가하고 있다. 이러한 추세 속에서 기존의 공정을 그대로 활용할 경우 식각물의 프로파일 왜곡 혹은 휨 현상이 발생하고 식각 속도가 저하되며 이러한 특성들이 결과적으로는 생산성의 저하로 이어질 수 있다. 이러한 현상을 최소화하기 위해서는 무엇보다 독립된 plasma parameter 들이 식각물의 프로파일 혹은 식각 속도 등에 어떠한 영향을 주는 지에 대한 학문적 이해가 필요하다. 본 논문에서는 최소 CD (Critical Dimenstion) 100nm, 최대 A/R 30 인 HARC (High Aspect Ration Contact hole) 의 식각 특성이 plasma parameter 에 따라 어떻게 변하는지 확인해 보고자 한다. 산화물의 식각은 대표적인 high density plasma source 중의 하나인 ICP에서 진행하였으며 기존에 알려진 plasma parameter 에 더하여 자장의 인가가 산화물의 식각 특성에 어떠한 영향을 주는지 살펴보고자 전자석을 ICP 에 추가로 설치하여 실험을 진행하였다. 결과적으로, plasma parameter 에 따른 혹은 자장의 세기 변화에 따른 산화물의 식각 실험을 플라즈마 진단 실험과 병행하여 진행함으로써 다양한 인자에 따른 산화물의 식각 메커니즘을 정확하게 이해하고자 하였다. 실험 내용을 요약하면 다음과 같다. 먼저, 전자석의 전류 인가 조건에 따라 축 방향 혹은 반경 방향으로의 자장의 분포가 달라질 수 있음을 확인하였고 플라즈마 진단 결과 축 방향 혹은 반경 방향으로의 자장이 증가하였을 때 고밀도의 플라즈마가 형성될 수 있음은 물론 반경 방향으로의 플라즈마 밀도의 균일도가 향상됨을 확인할 수 있었다. 또한 ICP 조건에서 바이어스 주파수, 압력, 바이어스 파워, 소스 파워, 가스 유량 등의 plasma parameter 가 산화물의 식각 특성에 미치는 영향 및 메커니즘을 규명하였고 이 과정을 통해 최적화된 프로파일을 바탕으로 축 방향 혹은 반경 방향으로 증가하는 자장을 인가하였을 때 (M-ICP 혹은 자화 유도 결합 플라즈마) ICP 대비 산화물의 식각 속도가 증가함은 물론 PR-to-oxide 의 선택비가 개선될 수 있음을 확인할 수 있었다. 자장의 인가에 따른 산화물의 정확한 식각 메커니즘은 향후의 실험 진행을 통해 이해하고 이를 통해 궁극적으로는 산화물의 식각 공정이 나아가야 할 올바른 방향을 제시하고자 한다.

  • PDF

Characterization of flow properties of pharmaceutical pellets in draft tube conical spout-fluid beds

  • Foroughi-Dahr, Mohammad;Sotudeh-Gharebagh, Rahmat;Mostoufi, Navid
    • Journal of Industrial and Engineering Chemistry
    • /
    • v.68
    • /
    • pp.274-281
    • /
    • 2018
  • Experimental studies of the hydrodynamic performance of the draft tube conical spout-fluid bed (DCSF) were conducted using pharmaceutical pellets. The experiments were carried out in a DCSF consisted of two sections: (a) a conical section with the cross section of $120mm{\times}250mm$ and the height of 270 mm, (b) a cylindrical section with the diameter of 250 mm and the height of 600 mm. The flow characteristics of solids were investigated with a high speed camera and a pezoresistive absolute pressure transducer simultaneously. These characteristics revealed different flow regimes in the DCSF: packed bed at low gas velocities, fluidized bed in draft tube at higher gas velocities until minimum spouting, and spouted bed. The stable spouting was identified by the presence of two dominant frequencies of the power spectrum density of pressure fluctuation signature: (i) the frequency band 6-9 Hz and (ii) the frequency band 12-15 Hz. The pressure drops across the draft tube as well as the annulus measured in order to better recognize the flow structure in the DCSF. It was observed that the pressure drop across the draft tube, the pressure drop across the annulus, and the minimum spouting velocity increase with the increase in the height of draft tube and distance of the entrainment zone, but with the decrease in the distributor hole pitch. Finally, this study provided novel insight into the hydrodynamic of DCSF, particularly minimum spouting and stable spouting in the DCSF which contains valuable information for process design and scale-up of spouted bed equipment.

Mechanism of Seismic Earth Pressure on Braced Excavation Wall Installed in Shallow Soil Depth by Dynamic Centrifuge Model Tests (동적원심모형실험을 이용한 얕은 지반 굴착 버팀보 지지 흙막이 벽체의 지진토압 메커니즘 분석)

  • Yun, Jong Seok;Park, Seong Jin;Han, Jin Tae;Kim, Jong Kwan;Kim, Dong Chan;Kim, DooKie;Choo, Yun Wook
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.27 no.5
    • /
    • pp.193-202
    • /
    • 2023
  • In this paper, a dynamic centrifuge model test was conducted on a 24.8-meter-deep excavation consisting of a 20 m sand layer and 4.8 m bedrock, classified as S3 by Korean seismic design code KDS 17 10 00. A braced excavation wall supports the hole. From the results, the mechanism of seismically induced earth pressure was investigated, and their distribution and loading points were analyzed. During earthquake loadings, active seismic earth pressure decreases from the at-rest earth pressure since the backfill laterally expands at the movement of the wall toward the active direction. Yet, the passive seismic earth pressure increases from the at-rest earth pressure since the backfill pushes to the wall and laterally compresses at it, moving toward a passive direction and returning to the initial position. The seismic earth pressure distribution shows a half-diamond distribution in the dense sand and a uniform distribution in loose sand. The loading point of dynamic thrust corresponding with seismic earth pressure is at the center of the soil backfill. The dynamic thrust increased differently depending on the backfill's relative density and input motion type. Still, in general, the dynamic thrust increased rapidly when the maximum horizontal displacement of the wall exceeded 0.05 H%.

Response of two-way reinforced concrete voided slabs enhanced by steel fibers and GFRP sheets under monotonic loading

  • Adel A. Al-Azzawi;Shahad H. Mtashar
    • Structural Monitoring and Maintenance
    • /
    • v.10 no.1
    • /
    • pp.1-23
    • /
    • 2023
  • Various efforts have been made to reduce the weight of concrete slabs while preserving their flexural strength. This will result in reducing deflection and allows the utilization of longer spans. The top zone of the slab requires concrete to create the compression block for flexural strength, and the tension zone needs concrete to join with reinforcing for flexural strength. Also, the top and bottom slab faces must be linked to transmit stresses. Voided slab systems were and are still used to make long-span slab buildings lighter. Eight slab specimens of (1000*1000 (1000*1000 mm2) were cast and tested as two-way simply supported slabs in this research. The tested specimens consist of one solid slab and seven voided slabs with the following variables (type of slab solid and voided), thickness of slab (100 and 125 mm), presence of steel fibers (0% and 1%), and the number of GFRP layers). The voids in slabs were made using high-density polystyrene of dimensions (200*200*50 mm) with a central hole of dimensions (50*50*50 mm) at the ineffective concrete zones to give a reduction in weight by (34% to 38%). The slabs were tested as simply supported slabs under partial uniform loading. The results of specimens subjected to monotonic loading show that the combined strengthening by steel fibers and GFRP sheets of the concrete specimen (V-125-2GF-1%) shows the least deflection, deflection (4.6 mm), good ultimate loading capacity (192 MPa), large stiffness at cracking and at ultimate (57 and 41.74) respectively, more ductility (1.44), and high energy absorption (1344.83 kN.mm); so it's the best specimen that can be used as a voided slab under this type of loading.

Toward Next Generation Solar Coronagraph: Diagnostic Coronagraph Experiment

  • Cho, Kyung-Suk;Yang, Heesu;Lee, Jaeok;Bong, Suchan;Choi, Seonghwan;Kim, Jihun;Park, JongYup;Park, YoungDeuk;Kim, Yeon-Han
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.42.2-42.2
    • /
    • 2019
  • Korea Astronomy and Space Science Institute (KASI) has been developing a next-generation coronagraph (NGC) in cooperation with NASA to measure the coronal electron density, temperature, and speed using four different filters around 400 nm. To demonstrate technology for the measurement through the 2017 total solar eclipse across the USA, KASI organized an expedition team to demonstrate the coronagraph measurement scheme and the instrumental technology. The observation site was in Jackson Hole, Wyoming, USA. We built an eclipse observation system, so-called Diagnostic Coronal Experiment (DICE), which is composed of two identical telescopes to improve a signal to noise ratio. The observation was conducted with 4 wavelengths and 3 linear polarization directions according to the planned schedule in a limited total eclipse time of about 140 seconds.Polarization information of corona from the data was successfully obtained but we failed to get the coronal electron temperature and speed information due to a low signal-to-noise ratio of the optical system. In this study, we report the development of DICE and observation results. TSE observation and analysis by using our own developed instrument gave an important lesson that a coronagraph should be carefully designed to archive the scientific purpose. This experience through TSE observation will be very useful for a success of NASA-KASI joint missions called the Balloon-borne Investigation of the Temperature and Speed of Electrons in the Corona (BITSE) and COronal Diagnostic EXperiment (CODEX).

  • PDF

Macroscopic Visualization of Diesel Sprays with respect to Nozzle Hole Numbers and Injection Angles (분공수와 분사각의 영향에 따른 거시적 디젤 분무 가시화)

  • Yongjin Jung;Jinyoung Jang;Choongsik Bae
    • Journal of ILASS-Korea
    • /
    • v.29 no.1
    • /
    • pp.32-37
    • /
    • 2024
  • Macroscopic visualization of non-evaporating sprays was experimentally conducted to investigate spray tip penetration and spray angle under low-density conditions, corresponding to an early injection strategy. Furthermore, injectors with varying injection angles (146° and 70°) and numbers of holes (8 and 14) were employed to examine the impact of injector configuration. Compared to the baseline injector, 8H146, which has 8 holes and a 146° injection angle, the spray tip penetration of the 8H70 injector was found to be longer. This can be attributed to higher momentum due to a smooth flow field between the sac volume and the nozzle inlet, which is located closer to the injector tip centerline. The increase in velocity led to intense turbulence generation, resulting in a wider spray angle. Conversely, the spray tip penetration of the 14H70 injector was shorter than that of the 8H70 injector. The competition between increased velocity and decreased nozzle diameter influenced the spray tip penetration for the 14H70 injector; the increase in momentum, previously observed for the 8H70 injector, contributed to an increase in spray tip penetration, but a decrease in nozzle diameter could lead to a reduction in spray tip penetration. The spray angle for the 14H70 injector was similar to that of the 8H146 injector. Moreover, injection rate measurements revealed that the slope for a narrow injection angle (70°) was steeper than that for a wider injection angle during the injection event.

Experimental and Numerical Analysis of Microvia Reliability for SLP (Substrate Like PCB) (실험 및 수치해석을 이용한 SLP (Substrate Like PCB) 기술에서의 마이크로 비아 신뢰성 연구)

  • Cho, Youngmin;Choa, Sung-Hoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.1
    • /
    • pp.45-54
    • /
    • 2020
  • Recently, market demands of miniaturization, high interconnection density, and fine pitch of PCBs continuously keep increasing. Therefore, SLP (substrate like PCB) technology using a modified semi additive process (MSAP) has attracted great attention. In particular, SLP technology is essential for the development of high-capacity batteries and 5G technology for smartphones. In this study, the reliability of the microvia of hybrid SLP, which is made of conventional HDI (high density interconnect) and MSAP technologies, was investigated by experimental and numerical analysis. Through thermal cycling reliability test using IST (interconnect stress test) and finite element numerical analysis, the effects of various parameters such as prepreg properties, thickness, number of layers, microvia size, and misalignment on microvia reliability were investigated for optimal design of SLP. As thermal expansion coefficient (CTE) of prepreg decreased, the reliability of microvia increased. The thinner the prepreg thickness, the higher the reliability. Increasing the size of the microvia hole and the pad will alleviate stress and improve reliability. On the other hand, as the number of prepreg layers increased, the reliability of microvia decreased. Also, the larger the misalignment, the lower the reliability. In particular, among these parameters, CTE of prepreg material has the greatest impact on the microvia reliability. The results of numerical stress analysis were in good agreement with the experimental results. As the stress of the microvia decreased, the reliability of the microvia increased. These experimental and numerical results will provide a useful guideline for design and fabrication of SLP substrate.

Growth and characterization of semi-insulating GaAs co-doped with Cr and In by vertical gradient freeze technique (수직온도구배냉각법으로 크롬과 인듐이 함께 도핑된 반절연 갈륨비소 단결정의 성장 및 특성평가)

  • Young Ju Park;Suk-Ki Min;Kee Dae Shim;Mann J. Park
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.4 no.1
    • /
    • pp.83-91
    • /
    • 1994
  • We have constructed a vertical gradient freeze (VGF) grower for GaAs single crystals 2 inch in diameter and have grown semi-insulating GaAs co-doped with Cr and In. For the co-doped crystal, the segregation coefficients of the dopants remain unchanged when compared to those doped with only Cr or In. The concentration of Cr and in atoms range from about $2{\Times}10_{16} to 3{imes}10^{17} cm^{-3}$ and $2{\Times}10^{19} to 3{\Times}10^{20} cm^{-3}$ at the seed to the tail part of the grown crystal, respectively. The averaged dislocation etch pit density is found to be less than $8000 cm^{-2}$ throughout the ingot. It is also found that there is some evidence of lattice hardening for the crystal in which the dislocation density is decreased to less than $1000 cm^{-2}$ as In concentration increases. The resistivity increases abruptly from $10^{-2}$ up to $10^8$ Ohm-cm, while the carrier concentration decreases from $10^{16}$ to $10^8 cm^{-3}$ along the growth direction of the GaAs crystal. Semi-insulating properties can be obtained above a critical concentration of Cr of about $6{\Times}10{^16} cm^{-3}$ in the crystal. The main deep levels existing in the GaAs: Cr,In sample are two electron traps at $E_C-0.81eV, E_C-0.35eV$, and two hole traps at $E_V+0.89eV, E_V+0.65eV$.

  • PDF