• Title/Summary/Keyword: Hold time

Search Result 626, Processing Time 0.029 seconds

Influence of Hold Time and Stress Ratio on Cyclic Creep Properties Under Controlled Tension Loading Cycles of Grade 91 Steel

  • Kim, Woo-Gon;Park, Jae-Young;Ekaputra, I Made Wicaksana;Kim, Seon-Jin;Jang, Jinsung
    • Nuclear Engineering and Technology
    • /
    • v.49 no.3
    • /
    • pp.581-591
    • /
    • 2017
  • Influences of hold time and stress ratio on cyclic creep properties of Grade 91 steel were systemically investigated using a wide range of cyclic creep tests, which were performed with hold times (HTs) of 1 minute, 3 minutes, 5 minutes, 10 minutes, 20 minutes, and 30 minutes and stress ratios (R) of 0.5, 0.8, 0.85, 0.90, and 0.95 under tension loading cycles at $600^{\circ}C$. Under the influence of HT, the rupture time increased to HT = 5 minutes at R = 0.90 and R = 0.95, but there was no influence at R = 0.50, 0.80, and 0.85. The creep rate was constant regardless of an increase in the HT, except for the case of HT = 5 minutes at R = 0.90 and R = 0.95. Under the influence of stress ratio, the rupture time increased with an increase in the stress ratio, but the creep rate decreased. The cyclic creep led to a reduction in the rupture time and an acceleration in the creep rate compared with the case of monotonic creep. Cyclic creep was found to depend dominantly on the stress ratio rather than on the HT. Fracture surfaces displayed transgranular fractures resulting from microvoid coalescence, and the amount of microvoids increased with an increase in the stress ratio. Enhanced coarsening of the precipitates in the cyclic creep test specimens was found under all conditions.

The Effects of Hold-relax Techniques after Inducing Delayed Muscle Pain on the Pain and Range of Motion of Joints (지연성 근육통 유발 후 유지-이완 기법이 통증과 관절가동범위에 미치는 영향)

  • Kim, Ji-Seon;Woo, Young-Keun;Ki, Kyong-Il
    • PNF and Movement
    • /
    • v.14 no.1
    • /
    • pp.15-21
    • /
    • 2016
  • Purpose: The purpose of the present study was to compare the effects of both general hold-relax techniques and hold-relax techniques using pumping on pain due to delayed muscle pain and on the range of motion (ROM) of joints. Methods: Thirty-nine young adult males and females were randomly assigned either to a hold-relax technique application group of 20 subjects or to a group of 19 subjects with hold-relax techniques applied using a pumping application. Tenderness thresholds, the ROM of joints, and pain intensities were measured on the biceps of the nondominant arm of the subjects in both groups before exercises were performed to induce delayed muscle pain. Tenderness thresholds were again measured 24hours, 48hours, and 72 hours after inducing delayed muscle pain. The relevant intervention methods were applied to the two groups after conducting the measurement at 48hours. As a statistical analysis method, repeated measure ANOVAs were conducted to examine the tenderness thresholds, ROMs of elbow joints, and pain intensities in the individual groups at the time points. Results: At 48 hours and 72 hours after application of the interventions, the general hold-relax technique application group showed greater changes in the tenderness thresholds, the ROMs of elbow joints, and the pain intensities than did the group applying hold-relax techniques using a pumping application (p>0.05). Conclusion: Based on the results of the present study, the application of hold-relax techniques is thought to have beneficial effects on pain resulting from delayed muscle pain and on limited ROMs of joints.

Heat Load Characteristics of Sea Water Cooling Apparatus on Inshore Fishing Boat (연근해 어선용 해수냉각장치의 열부하특성)

  • 한인근;문춘근;김재돌;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.6
    • /
    • pp.1317-1323
    • /
    • 2001
  • The circumstance is giving the blow against fishermen with the incoming-decreasing and the difficulty of crew's supply & demand and management. In addition, the depression of the external situation like the departure of WTO system and the plan of EEZ proclaim is forcing fishery into improving their fishing condition. By this international and domestic circumstance, development of the sea water cooling apparatus for fish hold storage is demanded sincerely. First of all, we Investigated load characteristics which based on development of sea water cooling system and optimum fish hold storage. The experimental results is as follows. In creasing the speed of compressor and mass blew rate of refrigerant, the temperature of NaCl solution is low. And the load characteristics experiment on fish hold storage outlet is as fellows. As time goes by, increasing the mass flow rate of NaCl solution, temperature difference between inlet and outlet is small in a model of fish hold storage. These results provide many useful informations applicable to an actual design of sea water cooling system and optimum fish hold storage.

  • PDF

Performance and parameter region for real time use in IEEE 802.4 token bus network

  • Park, Hong-Seong;Kim, Deok-Woo;Kwon, Wook-Hyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1805-1810
    • /
    • 1991
  • This paper derives the upper and the lower bound of the mean cycle time and the mean service time of the class 6 and the class 4, within which the minimum utilization constrain of the class 4 is guaranteed. Also, derived are conditions under which the token bus network is stable or unstable. These bounds and stable conditions are represented in terms of the high priority token hold time, the token rotation time and the arrival rate and the total station number etc. This paper suggest a parameter tuning algorithm in a partially symmetric token bus network with two classes, which maximizes the token rotation time for a suitable high priority token hold time and at the same time meets the stability condition of the network, the real time constraint and the minimum utilization constraint of the class 4.

  • PDF

Drift Self-compensating type Flux-meter Using Digital Sample and Hold Amplifier (Digital Sample and Hold 증폭기를 사용한 드리프트 자체 보상형 자속계의 제작)

  • Ka, Eun-Mie;Son, De-Rac
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.6
    • /
    • pp.332-335
    • /
    • 2005
  • Output voltage of the flux-meter has always drift due to the input bias current of non-ideal operational amplifier. In this study we have employed a digital sample and hold amplifier which has no voltage drop to compensate drift of the flux-meter automatically. The drift of the developed flux-meter was smaller than $5{\times}10^{-8}\;Wb/s$ for the integration time constant of $RC=10^{-3}$ s.

A minimizing method of baseline wandering using a difference signal in ECG (심전도 차신호를 이용한 기저선 변동의 최소화 방법)

  • Ju, Jangkyu;Lee, Ki Young
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.1 no.1
    • /
    • pp.7-12
    • /
    • 2008
  • This paper studies a method to minimize the baseline wandering that make hard to extract R-wave in ECG. This method uses a difference signal between ECG and ascending slope tracing waves to minimize the baseline wandering. When the slope of ECG signal maintains the value or falls, the ascending slope tracing wave follows ECG signal directly, and this wave holds that value of ECG signal when the slope begins to rises in a certain time(=hold time). After this hold time, this wave traces ECG signal again. This method has been applied to MIT/BIH database to verify its efficacy and validity in practical applications.

  • PDF

Development of Modified Creep-Fatigue Damage Model for High Temperature Life Prediction (고온 수명평가를 위한 수정 크립-피로 손상모델의 걔발)

  • Park, Jong-Joo;Seok, Chang-Sung;Kim, Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.11
    • /
    • pp.3424-3432
    • /
    • 1996
  • For mechanical system operating at high temperature, damage due to the interaction effect of creep and fatigue plays an important role. The objective of this paper is to develop a modified creep-fatigue damage model which separately analyzes the pure creep damage for hold time and the creep-fatigue interaction damage during startup and shutdown period. The creep damage was calculated by the general creep damage equation and the creep-fatigue interaction damage was calculated by the modified equation which is based on the frequency modified strain range method with strain rate term. In order to verify the proposed model, a service of high temperature low cycle fatigue tests were performed. The test specimens were made from inconel-718 superalloy and the test parameters were wave shape and hold time. A good agreement between the predicted lives based on the proposed model and experimentally obtained ones was observed.

Design and Fabrication of Clock Recovery Module for Gap Filter of Satellite DMB (위성 DMB 중계기용 클럭 재생 모듈 설계 및 제작)

  • Hong, Soon-Young;Shin, Yeoung-Seop;Hong, Sung-Yong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.4 s.119
    • /
    • pp.423-429
    • /
    • 2007
  • The clock recovery module of gap filler for satellite DMB is proposed. Proposed module sustains the output frequency of 10 MHz whether the received signal from the satellite is unstable or cut off within 0.5 sec. The advantages of this module is without frequency tuning at regular interval and low material cost. This module is fabricated by using CPLD as clock recovery IC and new type of loop filter for satisfying the fast lock time and long hold over time simultaneously. The measured performance of the fabricated module has a holdover time of 11 sec at frequency stability less than 0.01 ppm, and phase noise of -113 dBc/Hz at 100 Hz offset.

A Computer Simulation of Injection Rate Characteristics of Solenoid Type Common Rail Injector According to Injector Driving Current Patterns (인젝터 구동 전류 패턴 변화가 솔레노이드 타입 커먼레일 인젝터 분사율 특성에 미치는 영향에 대한 컴퓨터시뮬레이션)

  • Lee, Choong Hoon
    • Journal of ILASS-Korea
    • /
    • v.24 no.3
    • /
    • pp.114-121
    • /
    • 2019
  • The effect of injector driving current pattern on fuel injection rate of solenoid diesel common rail injector was studied by computer simulation. The time resolved fuel injection rate and injected quantity per stroke of a common rail injector driven with the five current patterns were computer simulated. The fuel injection rate and injected quantity per stroke according to the rail pressure and fuel injection period were also computer simulated. When the common rail injector was driven with the five driving current patterns of peak & hold, there was no difference in the fuel injection rate in the peak section regardless of all the current patterns of the five cases. On the other hand, the magnitude of the hold current value influenced the injection rate and injected quantity per stroke. That is, in the current pattern of three cases where the hold current value is equal to or more than a constant value of the peak current value, the fuel injection rates for the given common rail rail pressure and injection period are same one another. On the other hand, the current pattern of the two cases, in which the hold current value is smaller than a certain value, there is a large fluctuation in the fuel injection rate.

The Effects of Hold-Relax Technique and Mulligan's Straight Leg Raise with Traction Technique on Flexibility of Shortened Hamstring (유지-이완 기법과 멀리건의 견인을 동반한 뻗은다리올림 기법이 단축된 넙다리뒤근의 유연성에 미치는 영향)

  • Choi, Yul-jung;Sim, Hyun-po;Lee, Jun-yong
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.21 no.1
    • /
    • pp.5-11
    • /
    • 2015
  • Background: The purpose of this study was to investigate the effects of Mulligan's straight leg raise with traction technique and hold-relax technique on flexibility of hamstring in people with shortened hamstring. Methods: Thirty two subjects participated in this study. The subjects were assigned to either the Mulligan's straight leg raise with traction technique group (n=16) or the hold-relax technique group (n=16). 90-90 straight leg raise test was performed for evaluation of hamstring shortening at initial time of study. After intervention, immediate effect (immediately after intervention) and lasted effect (60 min after intervention) were assessed. Results: In the both Mulligan's straight leg raise with traction technique and hold-relax technique groups, significant improvements on flexibility of hamstring was observed in immediately and 60 minute after intervention (p<.05). However, there are no significant difference was observed between groups (p>.05). Conclusion: In the results of this study, both Mulligan's straight leg raise with traction technique and hold-relax technique show immediately and 60 minute after evaluation effectiveness in flexibility of hamstring of people with shortened hamstring. In addition, although the difference is not statistically significant, Mulligan's straight leg raise with traction technique was more increased average extension angle of knee joint at 90-90 straight leg raise test than the hold-relax technique.

  • PDF