• 제목/요약/키워드: Hoffman 3D brain phantom

검색결과 12건 처리시간 0.018초

적층 제조형 방식의 3D 프린터로 제작한 뇌 팬텀의 유용성 (Usefulness of Brain Phantom Made by Fused Filament Fabrication Type 3D Printer)

  • 이용기;안성민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권6호
    • /
    • pp.453-460
    • /
    • 2020
  • The price of the Brain phantom (Hoffman 3D brain phantom) used in nuclear medicine is quite expensive, it is difficult to be purchased by a medical institution or an educational institution. Therefore, the purpose of present research is to produce a low-price 3D brain phantom and evaluate its usefulness by using a 3D printer capable of producing 3D structures. The New 3D brain phantom consisted of 36 slices 0.7 mm thick and 58 slices 1.5 mm thick. A 0.7 mm thick slice was placed between 1. 5 mm thick slices to produce a composite slice. ROI was set at the gray matter and white matter scanned with CT to measure and compare the HU, in order to verify the similarity between PLA which was used as the material for the New 3D brain phantom and acrylic which was used as the material for Hoffman 3D brain phantom. As a result of measuring the volume of each Phantom, the error rate was 3.2% and there was no difference in the signal intensity in five areas. However, there was a significant difference in the average values of HU which was measured at the gray and white matter to verify the similarity between PLA and acrylic. By reproducing the previous Hoffman 3D brain phantom with a 100 times less cost, I hope this research could contribute to be used as the fundamental data in the areas of 3D printer, nuclear medicine and molecular imaging and to increasing the distribution rate of 3D brain phantom.

3D 프린팅 기법 기반의 Hoffman Brain 팬텀 개발 및 유용성 평가 (Development and Evaluation of the Usefulness for Hoffman Brain Phantom Based on 3D Printing Technique)

  • 박훈희;이주영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권6호
    • /
    • pp.441-446
    • /
    • 2019
  • The purpose of this paper is to recognize the usefulness of the Phantom produced with 3D printing technology by reproducing the original phantom with 3D printing technology. Using CT, we obtained information from the original phantom. The acquired file was printed by the SLA method of ABS materials. For inspection, SPECT/CT was used to obtain images. We filled the both Phantom with a solution mixed with 99mTcO4 1 mCi in 1 liter of water and acq uired images in accordance with the standard protocol. Using Image J, the SNR for each slice of the image was obtained. As a reference images, AC images were used. For the analysis of acquired images, ROI was set in the White mater and Gray mater sections of each image, and the average Intensity Value within the ROI were compared. According to the results of this study, 3D printed phantom's SNR is about 0.1 higher than the conventional phantom. And the ratio of Intensity Value was shown in the original 1 : 3.4, and the printed phantom was shown to be 1 : 3.2. Therefore, if Calibration Value is applied, It is assumed that it can be used as an alternative to the original.

Brain Perfusion SPECT에서 Image Registration의 유용성 (Usefulness of Image Registration in Brain Perfusion SPECT)

  • 송호준;임정진;김진의;김현주
    • 핵의학기술
    • /
    • 제15권2호
    • /
    • pp.60-64
    • /
    • 2011
  • Brain의 질병을 평가하는 유용한 검사방법 중의 하나인 brain perfusion SPECT는 환자의 움직임으로 인한 검사의 실패확률이 높아 one day method를 사용하지 못하고 two days method를 사용해야 하는 경우가 많다. 본 연구에서는 image registration을 사용하여 검사의 실패확률을 줄이고 one day method로 검사를 시행할 수 있는지 image registration을 적용할 경우 검사의 신뢰성을 알아보고자 하였다. Jaszczak phantom에 준비된 방사성동위원소 $^{99m}Tc$을 insert에 111 MBq/mL가 되도록 분배하여 넣고 나머지 background에 3,145 MBq/mL가 되도록 넣어 1:8의 비율로 phantom을 제작하고 Hoffman 2-D brain phantom과 cylindrical uniform phantom에는 111 MBq/mL가 되도록 만든다. 완성된 phantom은 기본 위치에서 frame 당 5 sec씩 총 120 frame을 획득하여 영상을 얻었다. 또 Phantom과 환자의 데이터를 가지고 original 영상과 registration 영상, registration 시행한 후에 original 영상을 subtraction한 영상과 registration하지 않은 영상에서 subtraction한 영상 간의 임의의 같은 위치에 ROI를 설정하고 영상에서 counts 차이를 알아보았다. 실험 결과 약간의 counts 차이를 보였으나 이것은 실험시간이 경과함에 따른 RI의 decay와 phantom의 구조물이 없는 cylindlical phantom에서 조차 약간의 counts의 차이를 보이는 바로 미루어 봤을 때 실험 결과 나온 counts의 차이는 적다고 할 수 있을 것이다. 따라서 registration을 활용하여 brain perfusion SPECT의 단점들을 개선하고 정확한 진단에 도움을 줄 수 있을 것으로 사료된다.

  • PDF

Brain SPECT 검사 시 Dynamic Continuous Mode의 유용성 평가 (The Evaluation of Dynamic Continuous Mode in Brain SPECT)

  • 박선명;김수영;최성욱
    • 핵의학기술
    • /
    • 제21권1호
    • /
    • pp.15-22
    • /
    • 2017
  • 본원에서 시행하는 Brain SPECT 검사는 $^{99m}Tc-ECD$ 또는 $^{99m}Tc-HMPAO$를 주사 한 후 뇌 영상을 얻어 뇌 관류상태를 평가하는 검사이다. 하지만 검사 중 일부 환자 상태가 불안정할 경우 움직임이 발생하여 재촬영이나 검사실패로 이어지는 경우가 발생 된다. 이에 현재의 Step and Shoot Mode(SSM)이 아닌 움직임이 발생되더라도 재구성을 통해 영상 구현이 가능한 Dynamic Continuous Mode(DCM)를 적용하여 환자의 재촬영과 피폭선량을 감소시키고 검사실에 운영 효율성을 높이고자함에 있다. Deluxe PET/SPECT Phantom과 Hoffman 3D Brain Phantom으로 Filtered Back Projection(FBJ)과 Iterated Reconstruction(IR)으로 재구성하여 영상을 구현하였다. 이미지를 가지고 핵의학과 5년이상의 임상경력이 있는 의사 5명과 방사선사 5명을 대상으로 리커트 5점 척도(Likert 5 Scale)와 블라인드 판독 테스트를 실시 하였다. 판독의 블라인드 테스트 결과 최소 DCM 3Repeat (30%)에서 7Repeat (50%)까지 판독에 영향을 주지 않는다고 답해 주었다. DCM으로 검사 시 환자 움직임이 발생되면 불필요한 부분을 제거하여 재촬영, 재주사의 감소를 가져올 수 있고, 장비 오류 시 영상을 재구성 후 구현 할 수 있어 검사실 운영 효율도 높을 수 있을 것으로 기대된다. 또한 SPECT검사뿐 만 아니라 SPECT/CT검사 에서도 활발한 연구가 적용 될 거라 기대 되며 마지막으로 실제 환자 적용은 환자 데이터의 충분한 수집 후 병원 판독 실정에 맞게 도입이 필요 하리라 사료된다.

  • PDF

Dual detector system에서 Brain SPECT의 new reconstruction method의 연구 (The Study of New Reconstruction Method for Brain SPECT on Dual Detector System)

  • 이형진;김수미;이홍재;김진의;김현주
    • 핵의학기술
    • /
    • 제13권1호
    • /
    • pp.57-62
    • /
    • 2009
  • 목적 : 기존의 fan-beam을 이용한 triple detector system에서 parallel collimator를 이용한 dual detector system으로 변화에 있어 acquisition과 processing 부분에서 발생할 수 있는 여러 가지의 변수를 phantom과 volunteer test를 통하여 실험해 보았다. 1 day protocol brain spect를 위하여 parallel collimator에서만 적용되는 OSEM2D와 OSEM3D의 비교 분석을 중점으로 하였고, 모든 연구는 동등한 검사시간으로 fan-beam을 사용하였던 Triple gamma camera보다 parallel을 사용한 dual camera에서 보다 우수한 영상을 구현하고자 하는 목표를 지향하였다. 실험재료 및 방법 : Normal time scan과 short time scan을 실시하였고, collimator 변화에 따른 영상의 변화도 알아보았다. Jaczack performance phantom과 Body IEC phantom을 이용하여 SNR과 contrast를 평가해보았고 Hoffman 3D phantom의 실험을 거쳐 volunteer test를 실시하였다. 결과 : Normal time과 short time의 비교에서는 FLASH3D를 제외한 OSEM2D와 FBP는 분석방법으로 부적합하였다. LEAP는 resolution과 sharpness 등 전체적인 영상의 질이 기존의 fan-beam을 이용한 영상과 유사하였고, LEUHR은 감도의 저하로 1 day protocol을 적용하기 위한 scan time에는 부적합하였다. 재구성법의 비교에서는 Flash-3D를 이용한 결과들이 기존의 FBP와 OSEM-2D보다 월등히 정확함을 정성적으로 확인하였다. 결론 : OSEM3D 재구성법으로 Dual detector system에서의 1 day protocol brain SPECT 시 Fan-beam보다 sensitivity가 떨어지는 parallel collimator의 단점을 보완하면서 영상의 질 또한 de-noising과 scatter correction, resolution recovery 등의 효과를 얻을 수 있으므로 1 day protocol brain SPECT의 검사의 적용에 유용할 것으로 사료된다. 그러나 이러한 half-time method라 제공되는 다양한 프로그램의 임상적용에 대한 광범 위한 연구가 현실적으로 필요하며 향후 계속적인 연구가 기대되는 바이다.

  • PDF

Evaluation of Images Depending on an Attenuation Correction in a Brain PET/CT Scan

  • Choi, Eun-Jin;Jeong, Mon-Taeg;Dong, Kyung-Rae;Kwak, Jong-Gil;Choi, Ji-Won;Ryu, Jae-Kwang
    • 방사선산업학회지
    • /
    • 제12권4호
    • /
    • pp.267-276
    • /
    • 2018
  • A Hoffman 3D Brain Phantom was used to evaluate two PET/CT scanners, BIO_40 and D_690, according to the radiation dose of CT (low, medium and high) at a fixed kilo-voltage-peak (kVp) with the tube current(mA) varied in 17~20 stages(Bio_40 PET/CT scanner: the tube voltage was fixed to 120 kVp, the effective tube current(mAs) was increased from 33 mAs to 190 mAs in 10 mAs increments, D_690 PET/CT scanner: the tube voltage was fixed to 140 kVp, tube current(mA) was increased from 10 mAs to 200 mAs in 10 mAs increments). After obtaining the PET image, an attenuation correction was conducted based on the attenuation map, which led to an analysis of the difference in the image. First, the ratio of white to gray matter for each scanner was examined by comparing the coefficient of variation (CV) depending on the average ratio. In addition, a blind test was carried out to evaluate the image. According to the study results, the BIO_40 and D_690 scanners showed a <1% change in CV value due to the tube current conversion. The change in the coefficients of white and gray matter showed that the Z value was negative for both scanners, indicating that the coefficient of gray matter was higher than that of white matter. Moreover, no difference was observed when the images were compared in a blind test.

Brain SPECT 영상의 Attenuation Correction 방법들에 대한 비교 (Comparison of Attenuation Correction Methods for Brain SPECT Ima)

  • 조진우;김창호;나수경;이귀원
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.120-125
    • /
    • 2012
  • 이 연구의 목적은 Brain SPECT (Single Photon Emission Computed Tomography)의 Non-attenuation correction (AC-non) 영상에 대한 attenuation correction(AC) 방법 중 Chang's method와 CT based attenuation correction(AC-CT) 사이의 count를 비교하기 위함이다. phantom study는 증류수로 채워진 hoffman 3D phantom에 $^{99m}Tc$ 37Mbq을 투여하였고, patient study는 normal volunteer에 $^{99m}Tc$-HMPAO 750Mbq를 정맥주입하고 Siemens사의 Symbia T6로 Brain SPECT 영상을 획득하였고 뇌 정량 분석을 하였다. 각각의 방법들을 적용한 transverse image는 같은 위치에서 재구성 되었으며 각각 10, 20, 30번째 slice에서 6개의 region of interest(ROI)를 그려 AC-non 과 AC-CT 그리고 Chang's method의 count를 비교하였다. phantom study에서 AC-non, AC-CT, Chang's method의 각각 평균 count는 $4606.8{\pm}511.3$, $16794.6{\pm}2429.4$, $8752.6{\pm}896.5$이었으며 patient study에서 $5460.8{\pm}519.6$, $15320{\pm}1171.6$, $12795{\pm}1422.1$이었다. phantom study에서 AC-CT와 AC-non 사이의 비는 3.70이고 Chang's method와 AC-non 사이의 비는 1.92였으며 patient study에서는 각각 2.85, 2.38이었다. 우리는 이 연구를 통하여 AC-CT가 Chang's method보다 더 높은 AC을 해준다는 걸 알 수 있었다. 그리고 Chang's method는 patient study에서의 AC 값이 phantom study에서의 AC값보다 더 높다는 것을 알 수 있었다. brain SPECT/CT를 시행하는 경우 scatter correction을 같이 시행하고 bone에 의한 감쇠 정보를 반영할 수 있는 AC-CT가 chang's method보다 정확하다 할 수 있겠다.

  • PDF

1-Day Protocol을 사용하는 Brain Perfusion SPECT에서 LEUR 콜리메이터의 유용성 (The Usefulness of LEUR Collimator for 1-Day Basal/Acetazolamide Brain Perfusion SPECT)

  • 최진욱;김수미;이형진;김진의;김현주;이재성;이동수
    • 핵의학기술
    • /
    • 제15권1호
    • /
    • pp.94-100
    • /
    • 2011
  • 1-day protocol method는 DIAMOX 영상에서 basal 영상을 감산시키는 방법으로 혈관 예비능을 평가하는데 있어서 매우 유용한 검사지만, 검사시간이 길기 때문에 움직임에 의한 불가피한 재검사율이 높다. 기하학적으로 차이가 있는 fan-beam 콜리메이터와 parallel 콜리메이터 중 임상적으로 1-day protocol method에 가장 효율적인 콜리메이터가 무엇인지 알아보았다. 삼중 헤드 감마카메라인 triad XLT 9 (TRIONIX)와 세 가지 콜리메이터(low energy high resolution-parallel beam: LEHR-par, ultra resolution-fan beam: LEUR-fan, super fine-fan beam: LESR-fan)를 사용하였다. PET/SPECT performance phantom, Hoffman 3D phantom, volunteer 실험을 실시하여 세 가지 콜리메이터의 감도, 대조도, 해상력, 영상의 질을 비교 측정하였다. Pixel size를 fan-beam 콜리메이터와 동일하게 하기 위하여 parallel 콜리메이터 실험 시 zoom factor를 2.0으로 변경하였다. Scan time은 50 kcounts/frame을 만족하게 하였으며 filtered back projection (FBP)의 재구성 방법을 사용하였고 각 콜리메이터 별 최적의 영상을 위하여 cut off 값을 변화하면서 비교 측정하였다. 총 획득 계수가 동일한 조건에서 해상력과 percent background variability는 LESR과 LEUR이 LEHR보다 우수한 결과를 나타내었고, 영상의 육안평가에서 선호도는 LESR, LEUR, LEHR 순이었다. 영상 획득 시간은 LESR이 낮은 감도로 인하여 LEUR과 LEHR보다 약 2배 더 길게 소요됐다. Volunteer 실험의 결과 LESR을 사용할 때보다 LEUR 또는 LEHR을 사용 할 때 약 10-14분 정도 시간이 감소했다. 1-day protocol method는 단 한 번의 움직임에도 재검사가 불가피하기 때문에 적절한 분해능뿐만 아니라 높은 감도의 유지를 위해 적절한 검사 방법의 확립이 중요하다 할 수 있다. 본 연구에서 동일한 계수를 획득할 경우 LEUR은 LESR보다 2배의 시간을 감소시킬 수 있었고 영상의 육안평가나 해상력도 LESR과 임상적으로 큰 차이를 보이지 않았으므로 Brain SPECT의 1-day protocol method에 가장 적합할 것으로 사료된다.

  • PDF

Flash 3D 재구성을 적용한 뇌 혈류 부하 단층 촬영 시 LEAP 검출기의 적용에 관한 연구: One Day Subtraction Method (The Study about Application of LEAP Collimator at Brain Diamox Perfusion Tomography Applied Flash 3D Reconstruction: One Day Subtraction Method)

  • 최종숙;정우영;류재광
    • 핵의학기술
    • /
    • 제13권3호
    • /
    • pp.102-109
    • /
    • 2009
  • 목적 : Siemens사의 Flash 3D(Pixon(R) method, 3D OSEM)는 검사 시간을 단축하면서 재구성을 통해 영상의 질을 높일 수 있도록 개발된 소프트웨어 프로그램으로써 핵의학 단층 촬영 시 유용하게 적용되고 있는 영상처리기법이다. 그러나 감산된 영상을 Flash 3D로 재구성하여 시행하는 뇌 혈류 부하 검사 시에 영상 획득시간을 짧게 하여 검사를 시행하면 재구성된 감산 영상의 신호 대 잡음비가(SNR, signal to noise ratio) 기저 영상에 비해 낮아지는 문제점이 있었다. 감산 영상의 SNR을 높이기 위해 LEAP 검출기를 사용하였고, 뇌혈관의 해상력보다는 혈관 확장의 예민도에 더 중점을 두었다. 본 실험은 뇌혈관 부하 단층 촬영 시 LEAP 검출기의 적용 가능성을 확인하고, Flash 3D를 이용한 적정 수준의 재구성 매개 변수를 파악하는 데 목적이 있다. 실험재료 및 방법 : (1) 팬텀 평가: $^{99m}Tc$을 넣은 Hoffman 3D Brain $Phantom^{TM}$을 이용하였다. LEAP와 LEHR 검출기로 첫 번째 영상을(부하 영상에 해당) 획득하고 $^{99m}Tc$의 반감기인 6시간 후 동일한 방법으로 두 번째 영상을(기저 영상에 해당) 획득하였다. 또한, 각각의 기저 영상과 감산 영상의 SNR 및 백질과 회백질의 비를 측정하였다. (2) 환자 영상의 평가: 2008년 5월부터 2009년 1월까지 LEAP 검출기로 촬영하여 정상으로 판독된 15명과 LEHR 검출기로 촬영하여 정상으로 판독된 13명의 환자를 대상으로 영상을 정성분석 하였다. Phantom에서 얻은 재구성 매개 변수를 대입하여 평가하였다. 하루 검사 프로토콜로 시행하였으며 기저에서 925 MBq, 부하에서 925 MBq의 $^{99m}Tc$-ECD를 투여하였다. 결과 : (1) 팬텀 평가: 각 검출기에서 획득한 계수치를 측정한 결과 LEHR 기저에서는 41~46 kcount, 부하에서 79~90 kcount, 감산에서 40~47 kcount가 측정되었다. LEAP의 경우 기저에서 102~113 kcount, 부하에서 188~210 kcount, 감산에서 94~103 kcount가 측정되었다. LEHR 감산 영상의 SNR은 LEHR 기저 영상과 비교하면 37% 감소하여 나타났고, LEAP 감산 영상의 SNR은 LEAP 기저 영상과 비교하면 17% 감소하여 나타났다. 회백질과 백질의 비는 LEHR 기저에서 2.2:1 감산에서 1.9:1로 측정되었고, LEAP 기저에서는 2.4:1 감산에서 2:1로 측정되었다. (2) 환자 영상의 평가: LEHR 검출기로 획득한 계수는 기저에서 대략 40~60 kcount, 부하에서 80~100 kcount 사이였다. 기저 및 부하 영상은 FWHM을 7 mm로 (타 장비의 Cutoff에 해당), 감산 영상은 FWHM을 11 mm로 설정하는 것이 적절하였다. LEAP는 기저에서 대략 80~100 kcount, 부하에서 180~200 kcount로 측정되었다. LEAP 영상은 기저 및 부하에서 FWHM을 5 mm로, 감산에서 7 mm로 설정해야 영상의 흐림을 줄일 수 있었다. 기저 및 부하 영상은 LEHR 영상이 LEAP 영상보다 해상력이 우수했다. 그러나 감산 영상의 경우 팬텀 실험과 같이 LEHR 영상의 SNR이 떨어져 영상이 거칠게 보였다. 감산 영상은 LEAP 영상이 LEHR 영상에 비해 SNR 및 예민도가 높게 평가되었다. LEHR과 LEAP 검출기의 모든 영상에서 subset과 iteration은 8회가 적절하였다. 결론 : LEAP 검출기를 이용해 적정 수준의 필터를 사용함으로써 SNR을 높여 보다 선명한 감산 영상을 획득할 수 있게 되었다. 하루 검사 프로토콜을 적용하여 Flash 3D로 재구성하는 경우, 보다 나은 감산 영상을 얻기 위해 LEAP 검출기의 적용을 고려해 볼 수 있을 것으로 판단된다.

  • PDF

물리적 요소가 SPECT 영상에 미치는 영향 (The effects of physical factors in SPECT)

  • 손혜경;김희중;나상균;이희경
    • 한국의학물리학회지:의학물리
    • /
    • 제7권1호
    • /
    • pp.65-77
    • /
    • 1996
  • 본 연구는 2-D 와 3-D 호프만 뇌 모형 ,3-D 제젝 모형, 그리고 단일광자방출전산화단층촬영을 이용하여 인공산물을 일으키는 요인중 자료 획득 요소, 감쇠, 잡음, 산란 그리고 재구성 방식이 영상에 미치는 영향을 분석, 평가하였다. 자료 획득 요소 중 섬광 카메라의 회전 각도와 반경을 각각 변화시키면서 영상을 획득하였다. 이때 회전 반경의 변화가 작을수록 더 우수한 질의 영상을 얻을 수 있었고 회전중심으로부터 반경이 짧을수록 영상이 더 우수하였으며 이는 모형에서 거리가 멀어질수록 조준기의 분해능이 떨어지기 때문이다. 제젝 모형에서 균일한 부위를 각 조준기에 대해 알맞는 감쇠계수를 찾는데 이용하였다. $^{99m}$ Tc 을 사용했을 때 각 조준기에 대해 가장 알맞는 감쇠계수는 모두 0.12$cm^{-1}$ /로 나타났으며, 이 값으로 각각의 영상에 대해 감쇠 보정을 해주었다. 감쇠 보정 전의 제젝 모형의 균일한 부위는 감쇠로 인해 움푹 패인 선 프로파일 모양을 나타내었고, 감쇠 보정을 해줌으로서 평행한 선 프로파일을 얻을 수 있었다. 또한 감쇠 보정을 해줌으로서 영상의 질을 개선할 수 있었다. 각 시간에 따른 잡음의 영향을 관찰하기 위해 1분, 2분, 5분, 10분, 20분에 대하여 각각 자료를 얻었다. 결과에서 1분 영상이 잡음의 영향을 가장 많이 받아 영상의 질이 나빴으며 반면에 20분 영상은 잡음의 영향을 적게 받아 영상의 질이 상대적으로 가장 좋았다. 이는 자료 획득 시간을 길게하여 계수되는 양을 늘려줌으로서 Poisson 분포를 따르는 방사능 분포의 통계적 오차를 줄일 수 있기 때문인 것으로 생각한다. 이중-에너지 창, 즉 산란 부분과 $^{99m}$ Tc 의 봉우리 에너지인 140KeV 중심 20% 에너지 구별 영역을 각각 설정한 후, 자료를 얻어 산란 보정 전과 후의 영상을 비교하였다. 제젝 모형의 경우 냉구 부위와 바 패턴 부위가 산란 보정 이전에 비해 산란 보정 이후가 더 잘 식별되었고, 3-D 호프만 뇌모형의 경우 산란 보정후 영상의 질이 더 우수하게 나타났다. 결론적으로 SPECT 영상이 자료 획득을 위한 매개변수, 감쇠, 잡음, 산란 그리고 재구성 방식에 많은 영향을 받는 것으로 나타났으며 임상 적용시 유용한 SPECT 자료를 얻기 위해서 이러한 인자들을 최적화 또는 보정해 주어야 할 것으로 생각된다.

  • PDF