• Title/Summary/Keyword: Histograms

Search Result 364, Processing Time 0.03 seconds

Removing Lighting Reflection under Dark and Rainy Environments based on Stereoscopic Vision (스테레오 영상 기반 야간 및 우천시 조명 반사 제거 기술)

  • Lee, Sang-Woong
    • Journal of KIISE:Software and Applications
    • /
    • v.37 no.2
    • /
    • pp.104-109
    • /
    • 2010
  • The lighting reflection is a common problem in image analysis and causes the many difficulties to extract distinct features in related fields. Furthermore, the problem grows in the rainy night. In this paper, we aim to remove light reflection effects and reconstruct a road surface without lighting reflections in order to extract distinct features. The proposed method utilizes a 3D analysis based on a multiple geometry using captured images, with which we can combine each reflected areas; that is, we can remove lighting reflection effects and reconstruct the surface. At first, the regions of lighting sources and reflected surfaces are extracted by local maxima based on vertically projected intensity-histograms. After that, a fundamental matrix and homography matrix among multiple images are calculated by corresponding points in each image. Finally, we combine each surface by selecting minimum value among multiple images and replace it on a target image. The proposed method can reduces lighting reflection effects and the property on the surface is not lost. While the experimental results with collected data shows plausible performance comparing to the speed, reflection-overlapping areas which can not be reconstructed remain in the result. In order to solve this problem, a new reflection model needs to be constructed.

A Design and Implementation of a Content_Based Image Retrieval System using Color Space and Keywords (칼라공간과 키워드를 이용한 내용기반 화상검색 시스템 설계 및 구현)

  • Kim, Cheol-Ueon;Choi, Ki-Ho
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.6
    • /
    • pp.1418-1432
    • /
    • 1997
  • Most general content_based image retrieval techniques use color and texture as retrieval indices. In color techniques, color histogram and color pair based color retrieval techniques suffer from a lack of spatial information and text. And This paper describes the design and implementation of content_based image retrieval system using color space and keywords. The preprocessor for image retrieval has used the coordinate system of the existing HSI(Hue, Saturation, Intensity) and preformed to split One image into chromatic region and achromatic region respectively, It is necessary to normalize the size of image for 200*N or N*200 and to convert true colors into 256 color. Two color histograms for background and object are used in order to decide on color selection in the color space. Spatial information is obtained using a maximum entropy discretization. It is possible to choose the class, color, shape, location and size of image by using keyword. An input color is limited by 15 kinds keyword of chromatic and achromatic colors of the Korea Industrial Standards. Image retrieval method is used as the key of retrieval properties in the similarity. The weight values of color space ${\alpha}(%)and\;keyword\;{\beta}(%)$ can be chosen by the user in inputting the query words, controlling the values according to the properties of image_contents. The result of retrieval in the test using extracted feature such as color space and keyword to the query image are lower that those of weight value. In the case of weight value, the average of te measuring parameters shows approximate Precision(0.858), Recall(0.936), RT(1), MT(0). The above results have proved higher retrieval effects than the content_based image retrieval by using color space of keywords.

  • PDF

Radiation-induced Apoptosis, Necrosis and G2 Arrest in Fadu and Hep2 Cells

  • Lee Sam-Sun;Kang Beom-Hyun;Choi Hang-Moon;Jeon In-Seong;Heo Min-Suk;Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.30 no.4
    • /
    • pp.275-279
    • /
    • 2000
  • Purpose: Radiation damage is produced and viable cell number is reduced. We need to know the type of cell death by the ionizing radiation and the amount and duration of cell cycle arrest. In this study, we want to identified the main cause of the cellular damage in the oral cancer cells and normal keratinocytes with clinically useful radiation dosage. Materials and Methods: Human gingival tissue specimens obtained from healthy volunteers were used for primary culture of the normal human oral keratinocytes (NHOK). Primary NHOK were prepared from separated epithelial tissue and maintained in keratinocyte growth medium containing 0.15 mM calcium and a supplementary growth factor bullet kit. Fadu and Hep-2 cell lines were obtained from KCLB. Cells were irradiated in a /sup 137/Cs γ-irradiator at the dose of 10 Gy. The dose rate was 5.38 Gy/min. The necrotic cell death was examined with Lactate Dehydrogenase (LDH) activity in the culture medium. Every 4 day after irradiation, LDH activities were read and compared control group. Cell cycle phase distribution and preG1-incidence after radiation were analyzed by flow cytometry using Propidium Iodine staining. Cell cycle analysis were carried out with a FAC Star plus flowcytometry (FACS, Becton Dickinson, USA) and DNA histograms were processed with CELLFIT software (Becton Dickinson, USA). Results: LDH activity increased in all of the experimental cells by the times. This pattern could be seen in the non-irradiated cells, and there was no difference between the non-irradiated cells and irradiated cells. We detected an induction of apoptosis after irradiation with a single dose of 10 Gy. The maximal rate of apoptosis ranged from 4.0% to 8.0% 4 days after irradiation. In all experimental cells, we detected G2/M arrest after irradiation with a single dose of 10 Gy. Yet there were differences in the number of G2/M arrested cells. The maximal rate of the G2/M ranges from 60.0% to 80.0% 24h after irradiation. There is no significant changes on the rate of the G0/G1 phase. Conclusion: Radiation sensitivity was not related with necrosis but cell cycle arrest and apoptosis. These data suggested that more arrested cell is correlated with more apoptosis.

  • PDF

Morphological Factors and Cardiac Doses in Whole Breast Radiation for Left-sided Breast Cancer

  • Guan, Hui;Dong, Yuan-Li;Ding, Li-Jie;Zhang, Zi-Cheng;Huang, Wei;Liu, Cheng-Xin;Fu, Cheng-Rui;Zhu, Jian;Li, Hong-Sheng;Li, Miao-Miao;Li, Bao-Sheng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.7
    • /
    • pp.2889-2894
    • /
    • 2015
  • Background: To investigate the impact of the breast size, shape, maximum heart depth (MDH), and chest wall hypotenuse (the distance connecting middle point of the sternum and the length of lung draw on the selected transverse CT slice) on the volumetric dose to heart with whole breast irradiation (WBI) of left-sided breast cancer patients. Materials and Methods: Fifty-three patients with left-sided breast cancer undergoing adjuvant intensity-modulated radiotherapy (IMRT) were enrolled in the study. The primary breast size and shape, MHD and DCWH (chest wall hypotenuse) were contoured on radiotherapy (RT) planning CT slices. The dose data of hearts were obtained from the dose-volume histograms (DVHs). Data were analyzed by one-way analysis of variance (ANOVA), Student's t-test and linear regression analysis. Results: Breast size was independent of heart dose, whereas breast shape, MHD and DCWH were correlated with heart dose. The shapes of breasts were divided into four types, as the flap type, hemisphere type, cone type and pendulous type with heart mean dose being $491.8{\pm}234.6cGy$, $752.7{\pm}219.0cGy$, $620.2{\pm}275.7cGy$, and $666.1{\pm}238.0cGy$, respectively. The flap type of breasts shows a strong statistically reduction in heart dose, compared to others (p=0.008 for V30 of heart). DCWH and MHD were found to be the most important parameters correlating with heart dose in WBI. Conclusions: More attention should be paid to the heart dose of non-flap type patients. The MHD was found to be the most important parameter to correlate with heart dose in tangential WBI, closely followed by the DCWH, which could help radiation oncologists and physicsts evaluate heart dose and design RT plan in advance.

Selectivity Estimation using the Generalized Cumulative Density Histogram (일반화된 누적밀도 히스토그램을 이용한 공간 선택율 추정)

  • Chi, Jeong-Hee;Kim, Sang-Ho;Ryu, Keun-Ho
    • The KIPS Transactions:PartD
    • /
    • v.11D no.4
    • /
    • pp.983-990
    • /
    • 2004
  • Multiple-count problem is occurred when rectangle objects span across several buckets. The CD histogram is a technique which selves this problem by keeping four sub-histograms corresponding to the four points of rectangle. Although It provides exact results with constant response time, there is still a considerable issue. Since it is based on a query window which aligns with a given grid, a number of errors nay be occurred when it is applied to real applications. In this paper, we propose selectivity estimation techniques using the generalized cumulative density histogram based on two probabilistic models : \circled1 probabilistic model which considers the query window area ratio, \circled2 probabilistic model which considers intersection area between a given grid and objects. Our method has the capability of eliminating an impact of the restriction on query window which the existing cumulative density histogram has. We experimented with real datasets to evaluate the proposed methods. Experimental results show that the proposed technique is superior to the existing selectivity estimation techniques. Furthermore, selectivity estimation technique based on probabilistic model considering the intersection area is very accurate(less than 5% errors) at 20% query window. The proposed techniques can be used to accurately quantify the selectivity of the spatial range query on rectangle objects.

An Efficient Video Sequence Matching Algorithm (효율적인 비디오 시퀀스 정합 알고리즘)

  • 김상현;박래홍
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.5
    • /
    • pp.45-52
    • /
    • 2004
  • According tothe development of digital media technologies various algorithms for video sequence matching have been proposed to match the video sequences efficiently. A large number of video sequence matching methods have focused on frame-wise query, whereas a relatively few algorithms have been presented for video sequence matching or video shot matching. In this paper, we propose an efficientalgorithm to index the video sequences and to retrieve the sequences for video sequence query. To improve the accuracy and performance of video sequence matching, we employ the Cauchy function as a similarity measure between histograms of consecutive frames, which yields a high performance compared with conventional measures. The key frames extracted from segmented video shots can be used not only for video shot clustering but also for video sequence matching or browsing, where the key frame is defined by the frame that is significantly different from the previous fames. Several key frame extraction algorithms have been proposed, in which similar methods used for shot boundary detection were employed with proper similarity measures. In this paper, we propose the efficient algorithm to extract key frames using the cumulative Cauchy function measure and. compare its performance with that of conventional algorithms. Video sequence matching can be performed by evaluating the similarity between data sets of key frames. To improve the matching efficiency with the set of extracted key frames we employ the Cauchy function and the modified Hausdorff distance. Experimental results with several color video sequences show that the proposed method yields the high matching performance and accuracy with a low computational load compared with conventional algorithms.

Histogram Equalization Based Color Space Quantization for the Enhancement of Mean-Shift Tracking Algorithm (실시간 평균 이동 추적 알고리즘의 성능 개선을 위한 히스토그램 평활화 기반 색-공간 양자화 기법)

  • Choi, Jangwon;Choe, Yoonsik;Kim, Yong-Goo
    • Journal of Broadcast Engineering
    • /
    • v.19 no.3
    • /
    • pp.329-341
    • /
    • 2014
  • Kernel-based mean-shift object tracking has gained more interests nowadays, with the aid of its feasibility of reliable real-time implementation of object tracking. This algorithm calculates the best mean-shift vector based on the color histogram similarity between target model and target candidate models, where the color histograms are usually produced after uniform color-space quantization for the implementation of real-time tracker. However, when the image of target model has a reduced contrast, such uniform quantization produces the histogram model having large values only for a few histogram bins, resulting in a reduced accuracy of similarity comparison. To solve this problem, a non-uniform quantization algorithm has been proposed, but it is hard to apply to real-time tracking applications due to its high complexity. Therefore, this paper proposes a fast non-uniform color-space quantization method using the histogram equalization, providing an adjusted histogram distribution such that the bins of target model histogram have as many meaningful values as possible. Using the proposed method, the number of bins involved in similarity comparison has been increased, resulting in an enhanced accuracy of the proposed mean-shift tracker. Simulations with various test videos demonstrate the proposed algorithm provides similar or better tracking results to the previous non-uniform quantization scheme with significantly reduced computation complexity.

Breast Radiotherapy with Mixed Energy Photons; a Model for Optimal Beam Weighting

  • Birgani, Mohammadjavad Tahmasebi;Fatahiasl, Jafar;Hosseini, Seyed Mohammad;Bagheri, Ali;Behrooz, Mohammad Ali;Zabiehzadeh, Mansour;meskani, Reza;Gomari, Maryam Talaei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7785-7788
    • /
    • 2015
  • Utilization of high energy photons (>10MV) with an optimal weight using a mixed energy technique is a practical way to generate a homogenous dose distribution while maintaining adequate target coverage in intact breast radiotherapy. This study represents a model for estimation of this optimal weight for day to day clinical usage. For this purpose, treatment planning computed tomography scans of thirty-three consecutive early stage breast cancer patients following breast conservation surgery were analyzed. After delineation of the breast clinical target volume (CTV) and placing opposed wedge paired isocenteric tangential portals, dosimeteric calculations were conducted and dose volume histograms (DVHs) were generated, first with pure 6MV photons and then these calculations were repeated ten times with incorporating 18MV photons (ten percent increase in weight per step) in each individual patient. For each calculation two indexes including maximum dose in the breast CTV ($D_{max}$) and the volume of CTV which covered with 95% Isodose line ($V_{CTV,95%IDL}$) were measured according to the DVH data and then normalized values were plotted in a graph. The optimal weight of 18MV photons was defined as the intersection point of $D_{max}$ and $V_{CTV,95%IDL}$ graphs. For creating a model to predict this optimal weight multiple linear regression analysis was used based on some of the breast and tangential field parameters. The best fitting model for prediction of 18MV photons optimal weight in breast radiotherapy using mixed energy technique, incorporated chest wall separation plus central lung distance (Adjusted R2=0.776). In conclusion, this study represents a model for the estimation of optimal beam weighting in breast radiotherapy using mixed photon energy technique for routine day to day clinical usage.

The Design and Implementation to Teach Sampling Distributions with the Statistical Inferences (통계적 추론에서의 표집분포 개념 지도를 위한 시뮬레이션 소프트웨어 설계 및 구현)

  • Lee, Young-Ha;Lee, Eun-Ho
    • School Mathematics
    • /
    • v.12 no.3
    • /
    • pp.273-299
    • /
    • 2010
  • The purpose of the study is designing and implementing 'Sampling Distributions Simulation' to help students to understand concepts of sampling distributions. This computer simulation is developed to help students understand sampling distributions more easily. 'Sampling Distributions Simulation' consists of 4 sessions. 'The first session - Confidence level and confidence intervals - includes checking if the intended confidence level is actually achieved by the real relative frequency for the obtained sample confidence intervals containing population mean. This will give the students clearer idea about confidence level and confidence intervals in addition to the role of sampling distribution of the sample means among those. 'The second session - Sampling Distributions - helps understand sampling distribution of the sample means, through the simulation method to make comparison between the histogram of sampling distributions and that of the population. The third session - The Central Limit Theorem - includes calculating the means of the samples taken from a population which follows a uniform distribution or follows a Bernoulli distribution and then making the histograms of those means. This will provides comprehension of the central limit theorem, which mentions about the sampling distribution of the sample means when the sample size is very large. The forth session - the normal approximation to the binomial distribution - helps understand the normal approximation to the binomial distribution as an alternative version of central limit theorem. With the practical usage of the shareware 'Sampling Distributions Simulation', we expect students to have a new vision on the sampling distribution and to get more emphasis on it. With the sound understandings on the sampling distributions, more accurate and profound statistical inferences are expected. And the role of the sampling distribution in the inferences should be more deeply appreciated.

  • PDF

Connection between the Amplitude Variations of the GPS Radio Occultation Signals and Solar Activity

  • Pavelyev, A.G.;Liou, Y.A.;Wickert, J.;Pavelyev, A.A.
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.348-357
    • /
    • 2008
  • The classification of the effect of ionospheric disturbances on the radio occultation signal amplitude has been introduced based on an analysis of more than 2000 seances of radio occultation measurements per formed with the help of the CHAMP German satellite. The dependence of the histograms of variations in the radio occultation signal amplitude on the IMF variation index has been revealed. It has been indicated that it is possible to introduce the radio occultation index characterizing the relation between ionospheric disturbances and solar activity. An amplitude radio occultation (RO) method is proposed to study connection between the ionospheric and solar activity on a global scale. Sporadic amplitude scintillation observed in RO experiments contain important information concerning the seasonal, geographical, and temporal distributions of the ionospheric disturbances and depend on solar activity. The probability of strong RO amplitude variations (RO $S_4$ index greater than 0.2) in the CHAMP RO signals diminishes sharply with the weakening of solar activity from 2001 to 2008. The general number of RO events with strong amplitude variations can be used as an indicator of the ionospheric activity. We found that during 2001-2008 the daily globally averaged RO $S_{4a}$ index depends essentially on solar activity. The maximum occurred in January 2002, minimum has been observed in summer 2008. Different temporal behavoir of $S_{4a}$ index has been detected for polar (with latitude greater than $60^{\circ}$) and low latitude (moderate and equatorial) regions. For polar regions $S_{4a}$ index is slowly decreasing with solar activity. In the low latitude areas $S_{4a}$ index is sharply oscillating, depending on the solar ultraviolet emission variations. The different geographical behavoir of $S_{4a}$ index indicates different origin of ionospheric plasma disturbances in polar and low latitude areas. Origin of the plasma disturbances in the polar areas may be connected with influence of solar wind, the ultraviolet emission of the Sun may be the main cause of the ionospheric irregularities in the low latitude zone. Therefore, the $S_{4a}$ index of RO signal is important radio physical indicator of solar activity.

  • PDF