• Title/Summary/Keyword: Hip replacement arthroplasty

Search Result 50, Processing Time 0.02 seconds

Preoperative Serum Albumin Levels Predict Treatment Cost in Total Hip and Knee Arthroplasty

  • Rudasill, Sarah E.;Ng, Andrew;Kamath, Atul F.
    • Clinics in Orthopedic Surgery
    • /
    • v.10 no.4
    • /
    • pp.398-406
    • /
    • 2018
  • Background: Hypoalbuminemia (serum albumin < 3.5 g/dL) is associated with increased morbidity and mortality in patients undergoing total hip arthroplasty (THA) and total knee arthroplasty (TKA). However, costs associated with hypoalbuminemia remain unknown. This study investigated the effect of serum albumin on direct treatment costs, length of stay (LOS), and readmissions for primary and revision THA and TKA patients. Methods: All adult patients at a single institution undergoing primary or revision THA or TKA between January 2014 and December 2016 were retrospectively reviewed. Patients were stratified by preoperative serum albumin level. The primary outcome was total direct costs at index hospitalization. Secondary outcomes included LOS and readmission within 30 days. Multivariable regressions were utilized to adjust for demographics and comorbidities. Results: Of 3,785 patients, 114 (3.0%) had hypoalbuminemia. After adjustment, hypoalbuminemia was associated with a 16.2% increase in costs (${\beta}=0.162$; 95% confidence interval [CI], 0.112 to 0.213; p < 0.001), representing an average cost increase of $3,383 (95% CI, $2,281 to $4,485) relative to costs for serum albumin > 4.5 g/dL. The increased total costs were significantly higher in revision ($4,322, p = 0.034) than in primary ($3,446, p < 0.001) procedures. In adjusted regression, each 1.0 g/dL increase in serum albumin yielded a 6.6% reduction in costs (${\beta}=-0.066$; 95% CI, -0.090 to -0.042]; p < 0.001), for average savings of $1,282 (95% CI, $759 to $1,806) per unit albumin. Adjusted regressions demonstrated that a 1-point increase in serum albumin reduced readmissions by 53% (odds ratio, 0.47; 95% CI, 0.31-0.73; p = 0.001) and LOS by 0.6 days (${\beta}=-0.60$; 95% CI, -0.76 to -0.44; p < 0.001). Conclusions: Hypoalbuminemia is associated with increased total direct costs, LOS, and readmissions following primary and revision THA and TKA. Future efforts to predict and address total costs should take into consideration the patient's preoperative serum albumin levels.

Deep Vein Thrombosis Prophylaxis after Total Hip Arthroplasty in Asian Patients

  • Kim, Jun-Shik
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.197-201
    • /
    • 2018
  • In Western patient populations, the reported incidence of imaging-demonstrated deep vein thrombosis (DVT) after total hip arthroplasty (THA) is as high as 70% without prophylaxis. The reported rates of symptomatic pulmonary embolism (PE) after THA in recent studies range from 0.6% to 1.5%, and the risk of fatal PE ranges from 0.11% to 0.19% in the absence of prophylaxis. Predisposing factors to DVT in western patients include advanced age, previous venous insufficiency, osteoarthritis, obesity, hyperlipidemia, dietary and genetic factors. However, Asian patients who have undergone THA have a strikingly low prevalence of DVT and virtually no postoperative PE. Some authors suggest low clinical prothrombotic risk factors and the absence of some DVT-related genetic factors in Asian patient populations decrease the risk of DVT, PE or both. In Korea, the prevalence of DVT after THA without thromboprophylaxis have ranges from 6.8% to 43.8%, and asymptomatic PE have ranges from 0% to 12.9%; there have been only two reported cases of fatal PE. Deep-wound infections resulting from postoperative hematomas or prolonged wound drainage have been reported with routine thromboprophylaxis. The prevalence of DVT differs varies based on patient ethnicity. Guidelines for the use of thromboprophylaxis were altered and focus on the potential value of outcomes compared with possible complications (e.g., bleeding).

Management of Severe Bone Defects in Femoral Revision following Total Hip Arthroplasty

  • Yicheng Li;Li Cao
    • Hip & pelvis
    • /
    • v.36 no.2
    • /
    • pp.101-107
    • /
    • 2024
  • Treatment of femoral bone defects continues to be a challenge in revision total hip arthroplasty (THA); therefore, meticulous preoperative evaluation of patients and surgical planning are required. This review provides a concise synopsis of the etiology, classification, treatment strategy, and prosthesis selection in relation to femoral bone loss in revision THA. A search of literature was conducted for identification of research articles related to classification of bone loss, management of femoral revision, and comparison of different types of stems. Findings of a thorough review of the included articles were as follows: (1) the Paprosky classification system is used most often when defining femoral bone loss, (2) a primary-length fully coated monoblock femoral component is recommended for treatment of types I or II bone defects, (3) use of an extensively porous-coated stem and a modular fluted tapered stem is recommended for management of types III or IV bone defects, and (4) use of an impaction grafting technique is another option for improvement of bone stock, and allograft prosthesis composite and proximal femoral replacement can be applied by experienced surgeons, in selected cases, as a final salvage solution. Stems with a tapered design are gradually replacing components with a cylindrical design as the first choice for femoral revision; however, further confirmation regarding the advantages and disadvantages of modular and nonmodular stems will be required through conduct of higher-level comparative studies.

Clinical and Functional Outcomes of the Exeter V40 Short Stem in Primary and Revision Arthroplasty: Does the Indication Affect Outcomes in the Short Term?

  • Nemandra Amir Sandiford;Scott M. Bolam;Irrum Afzal;Sarkhell Radha
    • Hip & pelvis
    • /
    • v.35 no.1
    • /
    • pp.40-46
    • /
    • 2023
  • Purpose: A variety of short Exeter stems designed specifically for use in performance of total hip arthroplasty (THA) in primary and revision settings have recently been introduced. Some have been used 'off label' for hip reconstruction. The aim of this study is to report clinical and radiological results from the Exeter V40 125 mm stem in performance of primary THA and revision THA. Materials and Methods: This study had a retrospective design. Insertion of 58 (24 primary, 34 revision) Exeter V40 125 mm stems was performed between 2015 and 2017. The minimum follow-up period was two years. Assessment of the Oxford hip score (OHS), EuroQol-5 Dimension (EQ-5D), and radiological follow-up was performed at one and two years. Results: In the primary group, the preoperative, mean OHS was 13.29. The mean OHS was 32.86 and 23.39 at one-year and two-year post-surgery, respectively. The mean EQ-5D-3L scores were at 0.14, 0.59, and 0.35, preoperatively, at one-year follow-up and two-year follow-up, respectively. In the revision group, the mean preoperative OHS was 19.41. The mean OHS was 30.55 and 26.05 at one-year and two-year post-surgery, respectively. The mean EQ-5D-3L scores were 0.33, 0.61, and 0.48 preoperatively, at one-year follow-up and two-year follow-up, respectively. No progressive or new radiolucent lines were observed around any stem at the time of the final follow-up in all patients in both groups. Conclusion: Encouraging results regarding use of Exeter V40 125 mm stems have been reported up to two years following surgery in primary and revision THA settings.

Effect of a PNF Intervention Strategy with the ICF Tool Applied to a Patient with Bilateral Total Hip Replacement Walking a Crosswalk (양측 엉덩관절 전치환술 환자의 횡단보도 걷기 개선을 위해 ICF Tool을 적용한 PNF 중재전략: 사례보고 )

  • Jin-cheol Kim;Jae-heon Lim
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.19 no.1
    • /
    • pp.95-105
    • /
    • 2024
  • PURPOSE: This study aimed to utilize the International Classification of Functioning, Disability, and Health (ICF) tool to identify a problem list and explore intervention effects using proprioceptive neuromuscular facilitation (PNF) for improving the crosswalk performance of patients who have undergone a bilateral hip arthroplasty. METHODS: The subject of this study was a 43-year-old male who had undergone a bilateral hip arthroplasty. To address the subject's functional status, a clinical decision-making process was carried out in the order of examination, evaluation, diagnosis, prognosis, intervention, and outcome. Patient information during the examination was collected using the ICF core set. The evaluation involved listing the items of each problem using the ICF assessment sheet and identifying the interaction between activity limitations and the impairment level. The diagnosis explicitly described the causal relationships derived from the evaluation using ICF terminology. The prognosis presented activity goals, body function, and structured goals in terms of the activity and participation levels that needed to be achieved for an individual's functional status. The intervention approached problems through the four components of the PNF philosophy, namely basic principles and procedures, techniques, and patterns, in an indirect-direct-task sequence. Results were compared before and after the intervention using the ICF evaluation display. RESULTS: The results of the study showed that the primary activity limitation, which was the walking time across the crosswalk, showed improvement, and the trunk's counter rotation and the weight-bearing capacity of both the lower limbs, which were impairment level indicators, were enhanced. CONCLUSION: This study suggests that PNF intervention strategies will serve as a positive approach for improving crosswalk walking in patients with bilateral hip arthroplasty.

Health Care Providers' Perceptions of Physical Function in Older Adults with Arthroplasty from Hip Fracture (고관절 골절로 인공고관절 수술을 받은 노인의 신체적 기능에 대한 의료인의 인식 분석)

  • Ko, Young Ji;Lee, JuHee
    • Journal of muscle and joint health
    • /
    • v.22 no.2
    • /
    • pp.67-77
    • /
    • 2015
  • Purpose: This study was a qualitative research using focus group interviews to collect data on the health care providers' perceptions of physical function in older adults with arthroplasty from hip fracture. Methods: A total of 12 subjects participated in this study. In order to conduct focus group interviews, structured manuscript, field notes, visual recording, and debriefing notes were referred and thematic analysis was used in analysis phase. Results: The six themes were raised: 'burdensome client', 'health care providers' perception of functional decline in older adults after surgery', 'health care providers' perception of caregiver', 'medical environment perceived as affecting physical function', 'crucial components perceived as encouraging functional restoration', and 'difficulty of pain management' with 18 subthemes. Conclusion: Healthcare providers perceived functional decline of elderly after arthroplasty and identified points facilitating or disturbing physical function Moreover, various perspectives on pain management related to physical function were represented.

Effect of Preoperative Warming on Prevention of Hypothermia during Surgery in Patients with Total Hip Replacement Arthroplasty under Spinal Anesthesia (척추마취하 고관절 전치환술 환자의 수술 전 가온이 수술 중 저체온 예방에 미치는 효과)

  • Lee, Min Ji;Jeong, Jeong Hee
    • Journal of Korean Clinical Nursing Research
    • /
    • v.26 no.3
    • /
    • pp.365-373
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the effect of preoperative warming to prevent hypothermia in surgery for patients undergoing total hip replacement arthroplasty under spinal anesthesia. Methods: A randomized experimental study was conducted. Data were collected at an S University hospital in Gyeonggido from December 3, 2019 to March 31, 2020. A random allocation program was used to randomize participants into intervention and control groups. A total of 90 participants were assigned to the study: 30 people were randomized to a pre-warming group using Bair Hugger forced-air warming blankets(Model 505) 30 minutes before surgery, 30 to a pre-warming group 15 minutes before surgery, or 30 to a control group. The findings from 88 participants were analyzed. For data analysis, χ2 test and ANOVA were used utilizing the SPSS 21.0 program. Results: The pre-warming group 30 minutes before surgery had significantly higher body temperature than the control group, from 30 minutes after inducing anesthesia to the end of anesthesia. Body temperature over anesthesia time showed significant differences among the three groups, but there were no statistically significant differences in interactions between time and groups. Conclusion: Warming patients' body for 30 minutes before surgery was effective in maintaining normal body temperature while preventing intraoperative hypothermia.

Change of the Cement Mantle Thickness According to the Movement of the Femoral Stem in THRA (인공고관절 치환술에서 대퇴주대 회전에 따른 시멘트막 두께 변화)

  • Park, Yong-Kuk;Kim, Jin-Gon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.2 s.191
    • /
    • pp.140-148
    • /
    • 2007
  • THRA(Total Hip Replacement Arthroplasty) has been widely used for several decades as a viable treatment of otherwise-unsolved hip problems. In THRA surgery, cement mantle thickness is critical to long-term implant survival of femoral stem fixed with cement. Numerous studies reported thin or incomplete cement mantle causes osteolysis, loosening, and the failure of implant. To analyze the effect of femoral stem rotation on cement thickness, in this study, we select two most popular stems used in THRA. Using CAD models obtained from a 3D scanner, we measure the cement mantle thickness developed by the rotation of a femoral stem in the virtual space created by broaching. The study shows that as the femoral stem deviates from the target coordinates, the minimum thickness of cement decreases. Therefore, we recommend development of a new methodology for accurate insertion of a femoral stem along the broached space. Also, modification of the stem design robust to the unintentional movement of a femoral stem in the broached space, can alleviate the problem.

Hip Range of Motion Estimation using CT-derived 3D Models (CT기반 3차원 모델을 이용한 고관절 운동범위 예측)

  • Lee, Yeon Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.115-122
    • /
    • 2018
  • The success of the total hip arthroplasty is revealed as initial stability, range of motion, and long term pain, etc. Depending upon choice of implantation options such as femoral neck offset, diameter of the femoral head, the lateral opening tilt. Especially the impingement between femoral head component and acetabular cup limits the range of motion of the hip. In this sense, estimation or evaluation of the range of motion before and after the total hip arthroplasty is important. This study provides the details of a computer simulation technique for the hip range of motion of intact hip as well as arthroplasty. The suggested method defines the hip rotation center and rotation axes for flexion and abduction, respectively. The simulation uses CT-based reconstructed 3D models and an STL treating software. The abduction angle of the hip is defined as the superolateral rotation angle from sagittal plane. The flexion angle of the hip is defined as the superoanterior angle from the coronal plane. The maximum abduction angle is found as the maximum rotation angle by which the femoral head can rotate superolaterally about the anterior-posterior axis without impingement. The maximum flexion angle is found as the maximum rotation angle by which the femoral head can rotate superoanteriorly about the medial-lateral axis without impingement. Compared to the normal hip, the total hip replacement hip showed decreased abduction by 60 degrees and decreased flexion by 4 degrees. This measured value implies that the proposed measurement technique can make surgeons find a modification of increase in the femoral neck offset or femoral head, to secure larger range of motion.

Atypical Vancouver B1 periprosthetic fracture of the proximal femur in the United Kingdom: a case report challenged by myeloma, osteoporosis, infection, and recurrent implant failures

  • Sayantan Saha;Azeem Ahmed;Rama Mohan
    • Journal of Trauma and Injury
    • /
    • v.37 no.1
    • /
    • pp.89-96
    • /
    • 2024
  • The indications for total hip replacement are increasing and not limited to osteoarthritis. Total hip replacement may also be done for trauma and pathological fractures in patients otherwise physiologically fit and active. This trend has led to an inevitable rise in complications such as periprosthetic femoral fracture. Periprosthetic femoral fracture can be challenging due to poor bone quality, osteoporosis, and stress fractures. We present a case of periprosthetic femoral fracture in a 71-year-old woman with some components of an atypical femoral fracture. The fracture was internally fixed but was subsequently complicated by infection, implant failure needing revision, and later stress fracture. She was on a bisphosphonate after her index total hip replacement surgery for an impending pathological left proximal femur fracture, and this may have caused the later stress fracture. Unfortunately, she then experienced implant breakage (nonunion), which was treated with a biplanar locking plate and bone grafting. The patient finally regained her premorbid mobility 13 months after the last surgery and progressed satisfactorily towards bony union.