• Title/Summary/Keyword: Hip replacement

Search Result 137, Processing Time 0.031 seconds

Developing Activity Based Clinical Pathway for Patients with Total Hip Replacement (활동기준관리를 적용한 인공고관절 전치환술 Clinical Pathway 개발)

  • Hong, Yoon-Mi
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.8 no.4
    • /
    • pp.669-689
    • /
    • 2002
  • Purpose : The purpose of the present study is to develop a clinical pathway applied with activity-based management methodology for efficient clinical management to cope with rapid changing medical environments. Method : After making a preliminary pathway based on which a conceptual frame of reference was established to develop a clinical pathway, the final one was confirmed by verifying experts validity and clinical validity. The ultimate activity-based clinical pathway was restructured after clarifying, schematizing and analyzing the whole activities of clinical pathway in accordance with the conducting process of activity-based management. Result : A clinical pathway for total hip replacement was developed, in which the vertical axis consisted of assessment, examination, consultation, medication, treatment, diet, activity, and education, and the horizontal axis was composed of six days of hospitalization. Then, on the basis of the development, the clinical pathway including the improved contents and information was restructured after making the reform measure by analyzing each of activities in the pathway. And the list of contents related to the clinical management activity was made, which was described its main contents and the pre-activities that ought to be completed before conducting each of activities in the pathway. Conclusion : The clinical pathway applied with activity-based management may be used as a standard guidance for providing continuous and consistent patient care. It will provide the information for nursing activities to nurses and the management information about hospital and nursing activities to the hospital administrators. It will also be used as a tool for communication between medical staff. Besides, it will contribute to creating profits for the hospital by shortening the length of stay in patients.

  • PDF

Micro Total Hip Replacement in Two Dogs with Legg-Calvé-Perthes Disease

  • Roh, Yoon-seok;Heo, Su-Young;Yoon, Jang-won;Park, Jiyoung;Jeong, Seong-Mok;Lee, Hae-beom
    • Journal of Veterinary Clinics
    • /
    • v.34 no.6
    • /
    • pp.454-458
    • /
    • 2017
  • A Maltese (case 1) and a Pomeranian (case 2) presented with acute right and left hind limb weight-bearing lameness. On physical examination, they exhibited severe pain and crepitus on the coxofemoral joint of affected hind limb. In addition, decreased thigh girth measurements were noted compared with the opposite leg. Radiological exam revealed necrotic areas in the femoral head of affected hind limb. These dogs were diagnosed with Legg-$Calv{\acute{e}}$-Perthes disease (LCPD). The dogs underwent micro total hip replacement (THR). After surgery, at 3 years (case 1) and 7 months (case 2), both dogs recovered normal activity. The thigh girth and lameness scores were apparently improved in the affected limbs of both dogs. No complications of prosthesis implants, such as loosening, were noted. The clinical outcomes of these cases indicate that dogs with LCPD can be successfully treated with micro THR and have a good prognosis immediately after surgery.

Prediction of Stress Distribution in the Ceramic Femoral Head after Total Hip Replacement (인공고관절 치환술 후 세라믹 대퇴골두에서 발생하는 응력분포 예측)

  • Han, Sung-Min;Chu, Jun-Uk;Song, Kang-Il;Park, Sung-Hee;Choi, Jae-Bong;Kim, Jung-Sung;Suh, Jun-Kyo Francis;Choi, Kui-Won;Youn, In-Chan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.6
    • /
    • pp.680-685
    • /
    • 2012
  • Ceramic femoral heads are now widely used in Total Hip Replacement (THR). Due to their high biocompatibility and low ductility, ceramic femoral heads are considered to be suitable for young and active patients. However, as in testing the mechanical stability of the femoral head, the conventional proof test (standard ISO 7206-10) has its limit of showing axisymmetric stress distribution on the contact surface, while non-uniformed stress distribution is expected after THR. Since non-uniformed stress distribution can result in the increased probability of ceramic femoral head fracture, it is considerable to evaluate the stress distribution in vivo-like conditions. Therefore, this study simulated the ceramic femoral heads under in vivo-like conditions using finite element method. The maximum stress decreased when increasing the size of the femoral head and stress distribution was concentrated on superior contact surface of the taper region.

Effect of Preoperative Warming on Prevention of Hypothermia during Surgery in Patients with Total Hip Replacement Arthroplasty under Spinal Anesthesia (척추마취하 고관절 전치환술 환자의 수술 전 가온이 수술 중 저체온 예방에 미치는 효과)

  • Lee, Min Ji;Jeong, Jeong Hee
    • Journal of Korean Clinical Nursing Research
    • /
    • v.26 no.3
    • /
    • pp.365-373
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the effect of preoperative warming to prevent hypothermia in surgery for patients undergoing total hip replacement arthroplasty under spinal anesthesia. Methods: A randomized experimental study was conducted. Data were collected at an S University hospital in Gyeonggido from December 3, 2019 to March 31, 2020. A random allocation program was used to randomize participants into intervention and control groups. A total of 90 participants were assigned to the study: 30 people were randomized to a pre-warming group using Bair Hugger forced-air warming blankets(Model 505) 30 minutes before surgery, 30 to a pre-warming group 15 minutes before surgery, or 30 to a control group. The findings from 88 participants were analyzed. For data analysis, χ2 test and ANOVA were used utilizing the SPSS 21.0 program. Results: The pre-warming group 30 minutes before surgery had significantly higher body temperature than the control group, from 30 minutes after inducing anesthesia to the end of anesthesia. Body temperature over anesthesia time showed significant differences among the three groups, but there were no statistically significant differences in interactions between time and groups. Conclusion: Warming patients' body for 30 minutes before surgery was effective in maintaining normal body temperature while preventing intraoperative hypothermia.

Electoacupuncture for Patients Undergoing Hip Arthroplasty: A Systematic Review and Meta-Analysis (고관절 치환술 환자에 적용한 전침치료: 체계적 문헌고찰 및 메타분석)

  • Oh, Eun-Mi;Hong, Su Min;Kim, Ho-Geol;Lee, Eun-Jung
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.30 no.4
    • /
    • pp.105-117
    • /
    • 2020
  • Objectives The objective of this study is to assess the effectiveness of electroacupuncture for patients with hip arthroplasty. Methods According to participants, intervention, comparison, outcome, study design, we searched for clinical studies that conducted electroacupuncture for patients with hip arthroplasty. Results Finally 11 randomized controlled trials were chosen for systemic review and meta-analysis. The frequently used evaluation tools were Incidence of postoperative cognitive dysfunction (POCD), heart rate, blood pressure. Almost studies showed electroacupuncture has effects for patients with hip arthroplasty. Through meta analysis, Electoacupuncture showed statistically significant effect of reducing the anesthetic dosage and incidence of postoperative psychonosema and adverse reactions in intra-operation period, reducing the incidence of POCD in peri-operation period, incidence of deep venous thrombosis in post-operation period. Conclusion 11 studies reported that electroacupuncture has significant effects on hip arthroplasty. But, many studies were assessed in a probable high risk of bias. And all studies published in one overseas country. So, it requires attention to comprehend this study. To make up for this limitaion, more well designed clinical research are needed.

A Review on the trends of acupuncture and moxibustion treatment for Hip arthroplasty (고관절 치환술에 침구치료를 적용한 국내외 연구에 대한 동향 분석)

  • Oh, Eun-Mi;Lee, Eun-Jung
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.14 no.1
    • /
    • pp.77-91
    • /
    • 2019
  • Objectives : The purpose of this study was to investigate the effects of using acupuncture and moxibustion for the treatment of hip arthroplasty. Methods : We searched a total of six Korean and international databases (OASIS, KISS, RISS, Pubmed, Cochrane library, and CNKI) up to March 2019, and included randomized controlled trials which investigated the treatment effects of acupuncture and moxibustion in patients with hip arthroplasty. Results : In total, 29 studies were selected and included in the analysis. These studies conducted interventions, with the most frequently conducted methods being electroacupuncture (24.1%) and auricular acupuncture (20.7%). The most frequently used acupoints were the Ashi-, Lower four-, and Lower five points. VAS (48.9%) and Harris scores (22.2%) were commonly used to evaluate treatment effects. In total, 27 studies (93.1%) reported favorable treatment effects following acupuncture and moxibustion treatment, compared to the control group. Conclusions : These results may suggest that acupuncture and moxibustion have favorable effect on Hip arthroplasty.

Analysis of Performance on Activities in Critical Pathway of Total Hip Replacement Surgery (고관절 전치환술 환자의 임상관리도 수행 정도)

  • Lim, You Jin;Jeong, Kyung In;Jeong, Ha Yun;Sun, JeongJu;Kim, Yun Kyung;Choi, Ji Kyung;Lee, Kum Lae;Kim, Jeong Suk;Yang, Jin Ju;Kim, Hye Ja;Jang, Keum Seong;Choi, Ja Yun
    • Korean Journal of Adult Nursing
    • /
    • v.18 no.5
    • /
    • pp.819-827
    • /
    • 2006
  • Purposes: The purpose of this study was to evaluate the extent of performance on activities in critical pathway (CP) according to eight domains and six admission days on nursing records of patients who received total hip replacement surgery. Methods: We reviewed 90 nursing records of patients who received total hip replacement surgery from June, 2004 to July, 2005 at C University Hospital. Data were collected using Hong's CP (2002) and were analyzed using ANOVA. Results: The domain of diet was valued the highest in CP performance scoring, followed by the domains of assessment, activities, and test. There were differences in the performance scores according to the period of admission in all of the domains. Among 132 activities in the CP, 18 activities were completely performed, of which most included activities belonging to the domain of assessment on the admission day. Twelve activities were never performed, of which most included activities belonging to the domain of treatment on the day of operation and the first day after operation. Conclusions: Therefore, further studies on the development of a new system to increase CP utilization and on updating the contents of CP from the best practice based on evidence is recommended.

  • PDF

The Analysis of Hospital Characteristics affecting Blood Transfusion to the patients under Knee or Hip Total Replacement Arthroplasty (슬관절과 고관절 전치환술 환자의 수혈에 영향을 미치는 병원특성 요인 분석)

  • Oh, Ji-Young;Kim, Sang-Mi;Lee, Seong-A
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4031-4039
    • /
    • 2015
  • The problems related with blood supply shortage and the stability of blood transfusion are on the rise, as it is expected that the blood doners will decrease but the blood use amount for aged population will increase, owing to low birth and aged population increase. The purpose of this study is to analyze the hospital characteristics which affect patients receiving and non-receiving blood transfusion for the knee and hip total replacement arthroplasty. Data were collected from Health Insurance Review and Assessment Service's 2011 sample data, and 5,370 inpatients were abstracted from them. Logistic regression analysis was performed, using SPSS 20. Independent variables used are hospital characteristics variables and patient characteristics variables. Hospital characteristics variables are hospital type, ownership, residence and the number of usable beds, and patient characteristics variables are gender, age, severity, type of anesthesia, main diagnosis, whether or not of anemia and insurance class. At the result of this study, it was found that hospital type, region, gender, age, severity, main diagnosis and whether or not of anemia were the factors that mostly affected the blood transfusion for knee arthroplasty. And hospital type, residence, gender, age, severity, type of anesthesia and whether of not of anemia were the factors that mostly affected the blood transfusion for hip arthroplasty. In addition to that, it is expected that this research which analyzed the present state of blood transfusion and its influence factors are cost effective, and would make a good use of preliminary data for good quality of medical service.

Wear and Implantation Tilt Measurements using X-ray and CAD (X-ray영상과 CAD를 이용한 인공고관절의 마모 및 식립각 측정법)

  • Lee, Jong Min;Lee, Yeon Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.107-114
    • /
    • 2018
  • Long-term complications such as loosening, wear, osteolytic lesion and granulomatous reaction by foreign bodies can occur, after total hip arthroplasty. The implantation alignment effects dislocation and wear, according to its amount and direction. Wear particles in total hip arthroplasty brings about biochemical complications such as osteolysis or send wear. In this sense, it is important to regularly check wear and alignment of total hip replacement. Because the wear in followup of 10 years may remain in a small amount, like a 1 or 2 mm generally, somewhat precise measurement tool has to be established. The wear and alignment measurement softwares commercially available currently lack in project saving or reproducibility. This study suggests a reliable method for the measurement using an X-ray image and a CAD software. The proposed method can be executed only if having a CAD software under most of current general clinical radiographical environment. The proposed was revealed through tests for the method to have accuracy of 0.06 mm with precision of 0.05 mm for wear measurement, and precision of 0.27 degrees for tilt measurement.