The Wear Rate and Survivorship in Total Hip Arthroplasty Using a Third-generation Ceramic Head on a Conventional Polyethylene Liner: A Minimum of 15-year Follow-up

  • Bum-Jin Shim;Sung-Jin Park;Chan Ho Park
    • Hip & pelvis
    • /
    • v.34 no.2
    • /
    • pp.115-121
    • /
    • 2022
  • Purpose: The purpose of this study was to evaluate the wear and survival rates of third-generation ceramic heads on a conventional ultra-high molecular weight polyethylene liner. Materials and Methods: A total of 160 hips (147 patients with a mean age of 55.9 years) who underwent total hip arthroplasty using the third-generation ceramic head on a conventional polyethylene liner from March 1998 to August 2003 were reviewed retrospectively. Evaluation of the wear rate for 56 hips (49 patients) followed-up for at least 15 years was performed using the PolyWare program version 8 (Draftware Developers, USA). The Kaplan-Meier survivorship was also evaluated. Results: Linear wear and volumetric wear rates were 0.11±0.47 mm/year and 32.75±24.50 mm3/year, respectively. Nine revisions were performed during the follow-up period because of cup or stem loosening. The Kaplan-Meier survival rate, using cup revision or total revision total hip arthroplasty (THA) as the endpoint of analysis, was 93.7% at 15 years and 73.6% at 20 years. Conclusion: Because all revisions were performed between 15 and 20 years in our study, surgeons should pay greater attention to patients who underwent THA with ceramic-on-polyethylene bearing from 15 years postoperatively. Contemporary alumina ceramic on highly cross-linked polyethylene could certainly be a good alternative bearing couple providing better longevity.

The Change in Readmission Rate, Length of Stay and Hospital Charge after Performance Reporting of Hip Hemiarthroplasty (고관절 부분 치환술 시술정보 공개에 따른 재입원율, 입원일수 및 진료비의 변화)

  • Jang, Won-Mo;Eun, Sang-Jun;SaGong, Pil-Young;Lee, Chae-Eun;Oh, Moo-Kyung;Oh, Ju-Hwan;Kim, Yoon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.43 no.6
    • /
    • pp.523-534
    • /
    • 2010
  • Objectives: We assessed impact of performance reporting information about the readmission rate, length of stay and cost of hip hemiarthroplasty. Methods: The data are from a nationwide claims database, National Quality Improvement Project database, of Health Insurance Review & Assessment Service in Korea. From January 2006 to April 2008, we received information of length of stay, readmission within 30 days, cost of 22 851 hip hemiarthroplasty episodes. Each episodes has retained the diagnoses of comorbidities and demographics. We used time-series analysis to assess the shifting of patients selections, between high volume (over 16 operations in a year) and low volume institutions, after performance reporting (December 2007). The changes of quality (readmission, length of stay) and cost were evaluated by multilevel analysis with adjustment of patient's factors and institutional factors after performance reporting. Results: As compared with the before performance reporting, the proportion of patients who choose the high volume institution, increased 3.45% and the trends continued 4 months at marginal significance (p = 0.059). After performance reporting, national average readmission rate, length of stay were decreased by 0.49 OR (95% CI=0.25 - 0.95) and 10% (${\beta}$=-0.102, p<0.01) and cost was not changed (${\beta}$=-0.01, p=0.27). The high volume institutions were more decreased than low volume in length of stay. Conclusions: After performance reporting, readmission rate, length of stay were decreased and the patient selections were marginally shifted from low volume institutions to high volume institutions.