• Title/Summary/Keyword: Highrise buildings

Search Result 45, Processing Time 0.021 seconds

Structural Seperation of Unsymmetric Highrise Apartments (비정형 고층아파트에서의 구조체 분리 간격)

  • 정하선;현창국;윤영호
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1989.04a
    • /
    • pp.56-60
    • /
    • 1989
  • It is well known that the symmetric buildings have higher resistance than the unaymetric ones do under seismic load. However, it is sometimes inevitable to build an unsymmetric structure due to the site conditions or architectural needs. The unsymmetric building has structural disadvantages under seismic load. In such a case the structural seperation joints are often used to avoid those disadvantages. This paper presents a method to determine the width of the seperation joints for unsymmetric, reinforced concrete apartments structured by walls and slabs only. The variables of the study were the ratio of shear-wall stiffness to the building length in the same directron, the building height and the story mass.

  • PDF

A Study of present and future highrise residential complex buildings in a structural practitioner's point of view (구조 설계 측면에서 본 국내 초고층 주거복합 건물의 현재와 미래)

  • Kim Jong-Ho
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.186-193
    • /
    • 2003
  • 최근 설계 및 시공되고 있는 국내 초고층 주거복합건물들의 유형과 구조설계내용들을 재점검하고 더 안전하고 경제적인 초고층 주거복합건물을 설계하기 위한 향후 과제로서 고강도 콘크리트 사용의 범용화와 구조적으로 유리한 기둥 배치계획과 횡력저항 요소로서의 Tubular 구조 및 Flat slab 등가골조 적용 등을 추가로 제시하며 또한 P.O.E의 구조적 측면에서의 도입자 인건비상승 및 후분양제도실시로 인한 공기단축등을 대비하는 철골조 아파트에 대한 지속적 상세연구가 필요하다고 판단된다. 또한 기둥의 부등축소문제, 내구성증대 및 거주성 향상문제 등도 관련 전문가들과 계속적 연구와 혐의가 필요한 것으로 생각된다.

  • PDF

A Case Study of The Design of Mega Foundations for High-rise Buildings (초고층 건축물의 대형기초 설계 사례)

  • Kim, Sung-Ho;Hong, Seung-Hyeun;Hong, Sa-Myun;Choi, Yong-Kyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2007.09a
    • /
    • pp.55-77
    • /
    • 2007
  • Currently a large number of high rise building projects are under plan and a mega foundation system to support this high load with safety is requiring. The foundation of a highrise building is displaced by the building load, which influence the behavior of a super structure in reverse. In this aspect, the structural interaction analysis between a foundation and a super structure is necessary. In this study, the relationship of a superstructure of building and a foundation has been reviewed, considering the tendency of design from a capacity driven design to a performance design. Two different case studies have been introduced to help understand this relationship in more specific, the first case is the high rise building founded on a mat system on rock and the second is that on large diameter bored piles on soft ground condition.

  • PDF

Differential Column Shortening of Plaza zrakyat Office Tower Including Inelastic Effect (비산성효과를 고려한 Plaza Rakyat 오피스동의 기둥부등축소량)

  • 송화철;유은종;정석창;주영규;안재현;박칠림
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.475-480
    • /
    • 1997
  • Highrise concrete buildings are very sensitive to cumulative and differential shortening of their vertical element such as wall and columns. Inelastic deformation due to creep and shrinkage consist of various factors and load history af actual building is very complicated. Therefore, for the accurate prediction and compensation of axial shortening, special efforts in design and construction phase are required to ensure long-term serviceability and strength requirement. In this paper, axial shortening estimation and compensation procedure is presented, which utilized experimentally determined concrete properties and preliminary load history and computerized approach, in case of Plaza Rakyat office tower, 79-story reinforced concrete building under construction in Malaysia.

  • PDF

Seisminc Response of Base Isolated Structures with MR Dampers (MR 감쇠기를 적용한 기초격리구조물의 지진응답)

  • 고봉준;황인호;이종세
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.505-512
    • /
    • 2003
  • As large structures such as highrise buildings and cable-stayed bridges become lighter and more flexible, the necessity of structural control for reducing excessive displacement and acceleration due to seismic excitation is increased. As a means to minimize seismic damages, various base isolation systems are adopted or considered for adoption. In this study, the seismic performance of M dampers are studied and compared with that of the NZ system as a base isolation system As the control algorithm of the MR damper, the clipped-optimal control(applied LQR method) is employed. A five-story building is modeled and the seismic performance of the two systems subjected to three different earthquakes is compared. The results show that the M damper system can provide superior protection than the NZ system for a wide range of ground motions.

  • PDF

Citic Tower Construction Key Technology

  • Xu, Lishan
    • International Journal of High-Rise Buildings
    • /
    • v.8 no.3
    • /
    • pp.185-192
    • /
    • 2019
  • Citic Tower is the first over-500 m-tall super highrise building in the world, located in the high seismic intensity area with paek ground acceleration over 0.2g in 475 years. This project is unique in its complexity, large volume, and challenging site conditions (zero site for construction). The traditional techniques can hardly meet safty, quality and schedule requirements of the construction. This article introduces the key construction technologies that are innovatively developed and applied in Citic Tower project construction, including intelligent super-high-rise building integrated construction platform system, independently developed by the CCTEB; Jump-Lift Elevator, which is the first of the kind with service height over 500 meters; combined temporary-and-permanent fire protection systems. The BIM technology is also applied in this project. Through technical innovation, and utilization of technologies, construction speed and safety had been greatly improved.

Enhancement of durability of tall buildings by using deep-learning-based predictions of wind-induced pressure

  • K.R. Sri Preethaa;N. Yuvaraj;Gitanjali Wadhwa;Sujeen Song;Se-Woon Choi;Bubryur Kim
    • Wind and Structures
    • /
    • v.36 no.4
    • /
    • pp.237-247
    • /
    • 2023
  • The emergence of high-rise buildings has necessitated frequent structural health monitoring and maintenance for safety reasons. Wind causes damage and structural changes on tall structures; thus, safe structures should be designed. The pressure developed on tall buildings has been utilized in previous research studies to assess the impacts of wind on structures. The wind tunnel test is a primary research method commonly used to quantify the aerodynamic characteristics of high-rise buildings. Wind pressure is measured by placing pressure sensor taps at different locations on tall buildings, and the collected data are used for analysis. However, sensors may malfunction and produce erroneous data; these data losses make it difficult to analyze aerodynamic properties. Therefore, it is essential to generate missing data relative to the original data obtained from neighboring pressure sensor taps at various intervals. This study proposes a deep learning-based, deep convolutional generative adversarial network (DCGAN) to restore missing data associated with faulty pressure sensors installed on high-rise buildings. The performance of the proposed DCGAN is validated by using a standard imputation model known as the generative adversarial imputation network (GAIN). The average mean-square error (AMSE) and average R-squared (ARSE) are used as performance metrics. The calculated ARSE values by DCGAN on the building model's front, backside, left, and right sides are 0.970, 0.972, 0.984 and 0.978, respectively. The AMSE produced by DCGAN on four sides of the building model is 0.008, 0.010, 0.015 and 0.014. The average standard deviation of the actual measures of the pressure sensors on four sides of the model were 0.1738, 0.1758, 0.2234 and 0.2278. The average standard deviation of the pressure values generated by the proposed DCGAN imputation model was closer to that of the measured actual with values of 0.1736,0.1746,0.2191, and 0.2239 on four sides, respectively. In comparison, the standard deviation of the values predicted by GAIN are 0.1726,0.1735,0.2161, and 0.2209, which is far from actual values. The results demonstrate that DCGAN model fits better for data imputation than the GAIN model with improved accuracy and fewer error rates. Additionally, the DCGAN is utilized to estimate the wind pressure in regions of buildings where no pressure sensor taps are available; the model yielded greater prediction accuracy than GAIN.

A Study on the Pilotis Design Characteristics in the Highrise Apartment Housing Estates (고충아파트 필로티 디자인 특성 분석에 관한 연구)

  • Lee Jeong-Soo;Song Yong-Ho;Yoo Uoo-Sang
    • Journal of the Korean housing association
    • /
    • v.16 no.6
    • /
    • pp.121-128
    • /
    • 2005
  • This study investigates the design features of pilotis applied to 20 high-rise apartment housings in Korea, completed between January 2000 and August 2005. It analyzes the design characteristics of pilotis on the basis of its spatial configuration and the residents' behavior and suggests the directions of pilotis design in the future. The study finds the followings. 1) The pilotis spaces in foreign apartment housings are used mainly for communal functions such as the passages between buildings for both pedestrians and vehicles. Compared with this public use of pilotis in foreign counterparts, the pilotis spaces in Korean apartment housings are semi-private and have multiple purposes. 2) The pilotis design can be classified on the basis of the spatial configuration elements and the patterns of residents' behavior. The spatial configuration elements consist of ceiling, column, wall, and floor; the residents' behavior can be classified as viewing, resting and playing, driving and parking, and keeping privately-owned objects such as motorcycle and bicycle. 3) Two spatial configuration elements, the wall and the ceiling and two behavioral patterns, 'resting and playing' and 'viewing' are getting more attention by designers in the apartment housings analyzed in this study.

Development of Large Tuned Mass Damper with Stroke Control System for Seismic Upgrading of Existing High-Rise Building

  • Hori, Yusuke;Kurino, Haruhiko;Kurokawa, Yasushi
    • International Journal of High-Rise Buildings
    • /
    • v.5 no.3
    • /
    • pp.167-176
    • /
    • 2016
  • This paper describes a large tuned mass damper (TMD) developed as an effective seismic control device for an existing highrise building. To realize this system, two challenges needed to be overcome. One was how to support a huge mass that has to move in any direction, and the second was how to control mass displacement that reaches up to two meters. A simple pendulum mechanism with strong wires was adopted to solve the first problem. As a solution to the important latter problem, we developed a high-function oil damper with a unique hydraulic circuit. When the mass velocity reaches a certain value, which was predetermined by considering the permissible displacement, the damper automatically and drastically increases its damping coefficient and limits the mass velocity. This velocity limit function can effectively and stably control the mass displacement without any external power. This paper first examines the requirements of the TMD using a simple model and clarifies the constitution of the actual TMD system. Then the seismic upgrading project of an existing high-rise building is outlined, and the developed TMD system and the results of performance tests are described. Finally, control effects for design earthquakes are demonstrated through response analyses and construction progress is introduced.

A Study on the semantic network system of the line of flow appearing on the residential space of super high-rise apartments (초고층아파트 주거공간에 나타난 동선의 의미적 네트워크 체계에 관한 연구)

  • Yoon, Jae-Eun;Kim, Joo-Hee
    • Korean Institute of Interior Design Journal
    • /
    • v.16 no.3 s.62
    • /
    • pp.58-65
    • /
    • 2007
  • The residential space of super high-rise buildings, having a form of a huge three-dimensional vertical city, affect the residents psychologically and qualitatively according to the line of flow. Because of these affects, the system of the line of flows is a very important factor. In this study, we recognize the super high-rise apartment's line of flow as a semantic network system based on case studies. And we also understand the mutual relationship by analyzing each space to recognize what effect it does on the residential environment. Furthermore, to bring up a better semantic network system for super high-rise apartment's line of flows is our goal. According to the case studies, the semantic network of the line of flow consists of 3 parts: the functional network, economical network and unit network. The functional network is composed of the 'need' and 'has', while the economical network includes variable walls that can be changed following the user's taste and eccentric positioned living rooms that protect personal privacy. Therefore the economical network started to appear while the personal value changed according to the improvement of the social condition. Finally, the unit network is a network that effects each unit that has ambiguous boundaries due to the appropriate arrangement between transitional spaces. And the unit network is based on the functional network.