• Title/Summary/Keyword: Higher Harmonics

Search Result 182, Processing Time 0.024 seconds

Measurement of Saturation Magnetostriction by the Second-order Higher Harmonics of ac Perturbing Magnetic Field (교류 섭동 자기장의 제 2차 고조파를 이용한 포화자기변헝 측정)

  • Cha, S.Y.;Kim, J.K.;Ryu, K.S.;Cho, Y.R.
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.2
    • /
    • pp.72-75
    • /
    • 2005
  • The profiles of the second-order higher harmonics during B-H hysteresis loop have been measured as functions of the tensile stress in grain-oriented $3.2{\%}$ Si steels. The observed harmonics profiles have been analyzed in terms of the nonlinear, asymmetric magnetization which reflects the domain reorientation under the field. The field interval of the second-order higher harmonics is related to the nucleation and annihilation fields and a measurement method for the magnetostriction is proposed using the harmonics profiles under tensile stress.

An Elimination Method of Harmonics in AC to DC Converter (AC/DC 컨버터의 고조파 제거 방법)

  • 오진석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.767-775
    • /
    • 2003
  • This paper considers the method of elimination harmonics in AC/DC converters, There are few practical methods to reduce the harmonics in AC/DC converters, particularly in filter design and control strategy. In this paper, a harmonic elimination methods are proposed, which includes hybrid PWM control strategy. These methods achieve precise output control along with the optimum performance simultaneously. The control method in this paper is developed to eliminate a fixed number of harmonics in AC to DC converter. The higher order harmonics can be easily eliminated by using filter proposed in this paper. The validity of these methods is confirmed experimentally.

Evaluation of Deterioration of Concrete due to High Temperature through Harmonics (고조파 평가를 통한 콘크리트의 고온 열화 평가)

  • Hwang, Eui-Chul;Kim, Guy-Yong;Son, Min-Jae;Pyeon, Su-Jeong;Sasui, Sasui;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.146-147
    • /
    • 2021
  • In this study, the deterioration of concrete subjected to high temperature was evaluated using harmonics. When concrete is exposed to high temperatures, its mechanical properties deteriorate. In order to evaluate this deterioration, a method of analyzing the waveform of elastic waves was applied. As the heating temperature increased, the fundamental wave of the 50 kHz elastic wave passing through the concrete decreased. In addition, harmonics were generated at each temperature, and the higher the heating temperature, the greater the ratio of harmonics. The higher the compressive strength, the greater the amplitude of the fundamental wave, and this phenomenon is thought to be due to the internal structure of concrete.

  • PDF

A Study on the Characteristic of Capacitor by Asymmetrical Voltage Unbalance (비대칭 전압 불평형에 의한 커패시터 동작 특성)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.18-23
    • /
    • 2010
  • As the increasing of Non-linear load, we have been growing interest for the harmonics. Harmonics has been focused on the current component rather than voltages. Voltage harmonics can be mainly generated at the PCC with non-linear load and act on voltage unbalance. Voltage harmonics can be enlarged at the capacitor with low impedance as frequency increases. Capacitor is basically used for the power-factor compensation and sometimes as the passive filter. Small voltage of low-order acts on quite a few at the capacitor by the current increase. Capacitor has easily fall under by harmonic components. In this paper, we measured the magnitude and phase angle of asymmetrical voltage with harmonics components at the PCC and calculated with the same condition. we concluded that voltage harmonics of higher order increase each current component but have a little effect on capacitor rating.

Torque Harmonics Minimization in PMSM by Using Flux Harmonics Estimation (쇄교자속 추정을 통한 영구자석형 동기전동기의 토오크 제어)

  • 문형태
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.439-442
    • /
    • 2000
  • An adaptive nonlinear control of a brushless direct drive motor(BLDDM) is proposed. Comparing to the traditional PMSM the direct drive motor has smaller number of per pole and per phase slots to provide higher torque in low speed. This generic construction generates flux harmonics and finally results in unwanted torque harmonics. To control the speed a feedback linearization method is applied by choosing the $i_{ds}$ and $\omega_{m}$ as the output variables. The control of the flux harmonics is provided by using a flux observer with MRAC technique. As shown in the simula-tion results the proposed nonlinear speed controller has a good speed response in the steady state and robust to the flux variation

  • PDF

Harmonics Analysis of Magnetostriction in 3% SiFe

  • Kim, C.G.;Ahn, S.J.;Jeong, M.H.;Kim, H.C.;Cha, S.Y.;Chang, S.K.
    • Journal of Magnetics
    • /
    • v.3 no.4
    • /
    • pp.120-122
    • /
    • 1998
  • The higher order harmonic components of magnetostriction during ac magnetization in 3% SiFe are measured as a function of the magnetizing angle respect to [001] axis using a constructed laser interferometry. The magnetostriction with magnetizing angle from [001] axis agrees ith the calculation based on domain reorientation. The relative amplitudes of odd and even harmonics respectively for magnetic induction and magnetostriction decrease with the order of harmonics, accompanying the contraction of the amplitudes. The contraction of harmonics order of magnetostriction harmonics is shown to be the even number times of that of magnetic induction.

  • PDF

Effect of Harmonics on Residual Current Protective Devices (고조파가 누전차단기에 미치는 영향)

  • Jeon, Jeong-Chay;Lee, Sang-Ick;Yoo, Jae-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.3
    • /
    • pp.84-89
    • /
    • 2006
  • Tripping of residual current protective devices(RCPDs) caused by harmonics has been continuously reported, but no literature is available on the behavior of RCPDs caused by harmonics. This paper, in order to find out the effects of harmonics on RCPDs, investigated the present condition on malfunction of RCPDs and measured harmonics at buildings where nuisance tripping of RCPDs was often occurred. Also, the operational characteristics of RCPDs were tested by the harmonics synthesizer that can generate distorted waveform. Results of experiment detected that there was minimum tripping current of RCPDs when third harmonic added to the fundamental frequency. And it was found that the leakage current to cause tripping of RCPDs increased with more higher order harmonics added to the fundamental frequency.

A Study on the Countermeasures to Suppress Harmonics in the Traction Power Supply System (철도 급전시스템에서의 고조파 해석 및 대책 연구)

  • 오광해;이장무;창상훈;한문섭;김길상
    • Proceedings of the KSR Conference
    • /
    • 1999.11a
    • /
    • pp.318-325
    • /
    • 1999
  • Modern AC electric car has PWM(Pulse Width Modulation)-controlled converters, which give rise to higher harmonics. The current harmonics injected from AC electric car is propagated through power feeding circuit, As the feeding circuit is a distributed constant circuit composed of RLC, the capacitance of the feeding circuit and the inductance on the side of power system cause a parallel resonance and a magnification of current harmonics at a specific frequency. The magnified current harmonics usually brings about various problems. That is, the current harmonics makes interference in the adjacent lines of communications and the railway signalling system. Furthermore, in case it flows on the side of power system, not only overheating and vibration at the power capacitors but also wrong operation at the protective devices can occur. Therefore, the exact assessment of the harmonic current flow must be undertaken at design and planning stage for the electric traction systems. From these point of view, this study presents an approach to model and to analyse traction power feeding system focused on the amplification of harmonic current The proposed algorithm is applied to a standard AT(Auto-transformer)-fed test system in which electric car with PWM-controlled converters is running.

  • PDF

Analysis on Harmonics Characteristics of ELF Magnetic Fields Generated by Electric Appliances (가전기기 발생 극저주파 자계 고조파 특성 해석)

  • Min Suk-Won;Song Ki-Hyun;Yang Kwang-Ho;Ju Mun-No
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.1
    • /
    • pp.31-37
    • /
    • 2005
  • With biological effects by ELF(Extremely Low Frequency) magnetic field generated from power system, the transient magnetic field from electric appliances is a major issue presently. In this paper, we measured magnetic field distributions around electric appliances in view of harmonics and analyzed them by the use of an equivalent magnetic dipole moment method. This method was applied to 19 types of appliances, and their equivalent magnetic dipole moments and harmonic components were determined. The results show that this method is applicable to many appliances and the higher frequency magnetic field may induce higher current inside living bodies.

Prediction of Core Loss Including Higher Harmonic Inductions Using Two Symmetrical AC Minor Loops

  • Son, Derac
    • Journal of Magnetics
    • /
    • v.8 no.2
    • /
    • pp.93-97
    • /
    • 2003
  • For the induction motor and inverter type motor design, prediction and analysis of core loss including higher harmonics have been studied. In this work, we have generated two symmetrical ac minor loop in the fundamental hysteresis loop whose positions are zero induction region and saturation induction region, and we could pre-dict core loss including higher harmonics inductions. using the following modified superposition principle; $P_c(B_0,f_0,B_h,nf_0)=P_c(B_0,f_0)+(n-1)[K_1(B_0)P_{cL}(B_h,nf_0)+(1-k_1(B_0))P_{cH}(B_h,nf_0)].$Using this equation we could also analyze core losses including higher harmonic induction under different maximum magnetic induction, different amplitude of higher harmonic induction with different harmonic frequencies.