• Title/Summary/Keyword: High-volume

Search Result 6,458, Processing Time 0.038 seconds

The Role of Plasma B-type Natriuretic Peptide Measurements in the Differential Diagnosis of Acute Dyspnea (급성호흡곤란의 감별진단에서 혈장 B-type Natriuretic Peptide의 역할)

  • Moon, Ji Yong;Bae, Joong Ho;Kim, Tae Hyung;Sohn, Jang Won;Yoon, Ho Joo;Shin, Dong Ho;Park, Sung Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.6
    • /
    • pp.656-663
    • /
    • 2005
  • Background : The B-type natriuretic peptide (BNP) is a cardiac neurohormone that is specifically secreted from the ventricles in response to volume expansion and a pressure overload. Differentiating congestive heart failure from the pulmonary causes of dyspnea is very important for patients presenting with acute dyspnea. Methods : A retrospective study was carried out on 261 patients who were admitted to the emergency department of Hanyang University Hospital due to acute dyspnea from March to July 2004. The serum BNP levels of the patients were measured using the ELISA method. Results : The BNP levels were 382, 111-1140 pg/ml (median, interquartile range) in the heart failure group (n=119) and 29, 7-81 pg/ml in the non-heart failure group (n=142). The BNP levels according to the subgroups of heart failure were 820, 354-1620 pg/ml, 1650, 239-1990 pg/ml, and 378, 106-1120 pg/ml for the chronic obstructive pulmonary disease (COPD) with combined left heart failure (n=5), cor pulmonale (n=3), and left heart failure groups (n=111), respectively. The BNP levels according to the subgroups of non-heart failure were 39, 21-101 pg/ml, 59, 10-129 pg/ml, and 15, 6-47 pg/ml for the COPD (n=20), other pulmonary diseases (n=56), and other causes groups (n=66), respectively. The BNP levels were significantly different according to the underlying etiology (p<0.001), and were significantly higher in the COPD patients with left heart failure than in those without (p=0.002). When the patients with no cardiovascular risk factor such as diabetes mellitus, hypertension, smoking or renal failure were analyzed, the BNP levels were also significantly higher in the patients with heart failure than in those without(p<0.001). When 133 pg/ml was designated as the BNP cut-off level the sensitivity for predicting heart failure was 73 percent and the specificity was 87 percent. Conclusion : BNP measurements are useful for determining the presence of heart failure in the patients presenting with acute dyspnea. The possibility of heart failure must be seriously considered in patients with high BNP levels even when they have a pre-existing pulmonary disease such as COPD or no risk factors for heart failure.

IGRINS Design and Performance Report

  • Park, Chan;Jaffe, Daniel T.;Yuk, In-Soo;Chun, Moo-Young;Pak, Soojong;Kim, Kang-Min;Pavel, Michael;Lee, Hanshin;Oh, Heeyoung;Jeong, Ueejeong;Sim, Chae Kyung;Lee, Hye-In;Le, Huynh Anh Nguyen;Strubhar, Joseph;Gully-Santiago, Michael;Oh, Jae Sok;Cha, Sang-Mok;Moon, Bongkon;Park, Kwijong;Brooks, Cynthia;Ko, Kyeongyeon;Han, Jeong-Yeol;Nah, Jakyuong;Hill, Peter C.;Lee, Sungho;Barnes, Stuart;Yu, Young Sam;Kaplan, Kyle;Mace, Gregory;Kim, Hwihyun;Lee, Jae-Joon;Hwang, Narae;Kang, Wonseok;Park, Byeong-Gon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.90-90
    • /
    • 2014
  • The Immersion Grating Infrared Spectrometer (IGRINS) is the first astronomical spectrograph that uses a silicon immersion grating as its dispersive element. IGRINS fully covers the H and K band atmospheric transmission windows in a single exposure. It is a compact high-resolution cross-dispersion spectrometer whose resolving power R is 40,000. An individual volume phase holographic grating serves as a secondary dispersing element for each of the H and K spectrograph arms. On the 2.7m Harlan J. Smith telescope at the McDonald Observatory, the slit size is $1^{{\prime}{\prime}}{\times}15^{{\prime}{\prime}}$. IGRINS has a plate scale of 0.27" pixel-1 on a $2048{\times}2048$ pixel Teledyne Scientific & Imaging HAWAII-2RG detector with a SIDECAR ASIC cryogenic controller. The instrument includes four subsystems; a calibration unit, an input relay optics module, a slit-viewing camera, and nearly identical H and K spectrograph modules. The use of a silicon immersion grating and a compact white pupil design allows the spectrograph collimated beam size to be 25mm, which permits the entire cryogenic system to be contained in a moderately sized ($0.96m{\times}0.6m{\times}0.38m$) rectangular Dewar. The fabrication and assembly of the optical and mechanical components were completed in 2013. From January to July of this year, we completed the system optical alignment and carried out commissioning observations on three runs to improve the efficiency of the instrument software and hardware. We describe the major design characteristics of the instrument including the system requirements and the technical strategy to meet them. We also present the instrumental performance test results derived from the commissioning runs at the McDonald Observatory.

  • PDF

Relationship between Environmental Exposure and Biological Monitoring Values in Workers Exposed to Styrene (스타이렌 폭로 근로자의 환경중 폭로농도와 생물학적 모니터링에 관한 연구)

  • Paik, Jong-Min;Lee, Jong-Yung;Kim, Jung-Man
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.2
    • /
    • pp.161-170
    • /
    • 1997
  • This is an effort to confirm changes biological monitoring according to changes in levels of exposure to styrene for industrial workers. This study was conducted on 108 workers, including male of 64 and female 44 who were working at factories of FRP, dipping, and coating. An improved passive monitor method(organic vapor monitor; OVM) was employed to determine levels of exposure. The biological monitoring include blood styrene concentration, urinary mandelic acid(MA), and urinary phenylglyoxylic acid(PGA). Biological monitoring were made through the Collection of blood and urine. The mean value of exposure to styrene was 21.0ppm, which is measured by organic vapor monitor, one of improved passive monitors. The highest exposure level was observed among workers in boat factories, laminating procedure workers, processing workers, respectively(p<0.01). For exposure level, 11% of subjects under study showed over 50ppm which is time weighted average(TWA). The correlation coefficient between biological specimens and the exposure level was 0.62 for blood styrene concentration, 0.58 for MA corrected by creatinine, and 0.70 for PGA corrected by creatinine, respectively(p<0.01). The regression analyses found exposure level relative importance in explaining variance in biological monitoring. In additional to that, gender was a significant factor in explaining variance of MA and MA+PGA. Almost half of variance(49%) in blood styrene concentration was explained by predictors, including exposure level, age, gender, duration, and drinking volume during the last week(p<0.01). The very high correlation(higher than 0.95 was found when a comparison was made among three types of corrected methods, including uncorrected specific gravity and creatinine. In conclusion, these findings suggest OVM to represent levels of exposure to styrene for industrial workers. A discussion was made on possible use of specific gravity sample for biological monitoring. Exposure level may be predicted on MA, PGA in urine, which could be applied to represent biological monitoring.

  • PDF

THE EFFECT OF FERMENTED MILK ON VIABLE CELL COUNT AND BIOFILM FORMATION OF STREPTOCOCCUS MUTANS (유산균 발효유가 Streptococcus mutans의 생균수 및 biofilm 형성에 미치는 영향)

  • Shin, Hye-Sung;Kim, Seon-Mi;Choi, Nam-Ki;Yang, Kyu-Ho;Kang, Mi-Sun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.3
    • /
    • pp.358-366
    • /
    • 2009
  • Lactic acid bacteria worked positively on gastrointestinal tract and oral environment. So I selected commercial five fermented milks and milk, and then I evaluated their effect of growth inhibition and biofilm formation of cariogenic bacteria, Streptococcus mutans. And also calculated the acidity, buffering capacity, concentration of Ca and P ion and pH change of those drinks. After adding S. mutans to fermented milks viable cell count of S. mutans in milk was not statistically different but those in all fermented milks were decreased as concentration of fermented milk increased. When I measured the amount of formed biofilm in 10% fermented milks and milk with S. mutans and compared with those without S. mutans, the amount was decreased in Active GG and Bulgaris while being increased in Tootee, Ace and milk(P<0.05). The fermented milk with the lowest pH value was E5(3.48${\pm}$0.01), and the highest was Bulgaris(4.19${\pm}$0.02). pH change of the fermented milks and milk with S. mutans was measured. The highest acid producing fermented milk was Bulgaris, and followed by Active GG, Ace, Tootee, E5, Milk. These results indicated that fermented milks had caries activity due to the value of initial acidity and acid producing capacity. But, concentrated fermented milks had the inhibitory effect against S. mutans, and also had high volume of Ca and P ion that protected teeth. So I suggest that they have positive effect on teeth.

  • PDF

Detection of Pathogenic Viruses in the Atmosphere during Asian Dust Events in Incheon City (인천지역에서 황사 기간 동안 대기 중의 바이러스 검출에 관한 연구)

  • Park, Jeong Woong;Lim, Young Hee;Kyung, Sun Young;An, Chang Hyeok;Lee, Sang Pyo;Jeong, Seong Hwan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.3
    • /
    • pp.279-285
    • /
    • 2005
  • Background : Ambient particles during Asian dust events are usually less than $10{\mu}m$ in size, and known to be associated with the adverse effects on the general population. There is little evidence linking Asian dust to adverse effects on the airways. In 2002, the authors found that particulate matter during Asian dust events had an effect on the symptoms and pulmonary function of patients with bronchial asthma. An aggravating factor might be that of a viral infection, but this remains unclear. Conversely, it has been speculated that African dust may carry the virus responsible for foot and mouth disease. Asian dust events are also likely to be responsible for transporting viruses, some of which are pathogenic, and common in many environments. Therefore, in this study, air samples were screened for the presence of viruses. Methods : Air samples were collected 20 times each during Asian dust events and under non-dust conditions, for at least 6 hours per sample, using a high volume air sampler (Sibata Model HV500F), with an airflow rate of 500L/min, between April and August 2003, and between April and August 2004. The samples were then screened for the presence of targeted viruses (Influenza A, B, Hog cholera virus, and Aphthovirus) using a polymerase chain reaction method. Results : One Asian dust event occurred between April and August 2003, and 3 between April and August 2004, with a 24 hour average PM10 level of $148.0{\mu}g/m^3$. The 24 hour average PM10 level was $57{\mu}g/m^3$. There was a significant difference in the PM10 concentration between dusty and clear days. No viruses (Influenza virus, Aphthovirus, and Hog cholera virus) were identified in the air samples obtained during the dusty days. Conclusions : Although no virus was detected in this study, further studies will be needed to identify suspected viruses carried during Asian dust events, employing more appropriate virus detection conditions.

Clinical Value of a Desktop Spirometer (HI-801) for Spirometry Screening (선별 검사를 위한 탁상용 폐활량기 (HI-801)의 임상적 유용성에 관한 고찰)

  • Choi, Hye Sook;Choi, Cheon Woong;Park, Myung Jae;Kang, Hong Mo;Yoo, Hong Ji
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.4
    • /
    • pp.276-283
    • /
    • 2007
  • Background: A national health care initiative recommends routine spirometry screening of all smokers over age 45 or patients with respiratory symptoms. In response to the recommendation, new, simple, and inexpensive desktop spirometers for the purpose of promoting widespread spirometric screening were marketed. The performance of these spirometers was evaluated in vivo testing with healthy subjects. However, the clinical setting allows spirometric assessment of various pathologic combinations of flow and volume. Objective: The aim of this study was to compare the accuracy of a desktop spirometer to a standard laboratory spirometer, in a clinical setting with pathologic pulmonary function. Method: In a health check-up center, where screening pulmonary funct test was performed using the HI-801 spirometer. Subjects who revealed the ventilation defect in screening spirometry, performed the spirometry again using the standard Vmax spectra 22d spirometer in a tertiary care hospital pulmonary function laboratory. Pulmonary function test with both spirometer was performed according to the guidelines of the American Thoracic Society. Results: 109 patients were enrolled. Pulmonary function measurements (FVC, $FEV_1$, PEFR, FEF25%-75%) from the HI-801 correlated closely (r=0.94, 0.93, 0.81, 0.84, respectively) with those performed with the Vmax spectra 22d and showed the good limits of agreement and differences between the 2 devices; FVC +0.35 L, $FEV_1$ +0.16 L, PEFR +1.85 L/s, FEF25%-75%-0.13 L/s. With the exception of $FEV_1$, FEF25%-75%, these differences were significant(p<0.05) but small. Conclusion: The HI-801 spirometer is comparable to the standard laboratory spirometer, Vmax spectra 22d, with high accurary for $FEV_1$ and FVC and acceptable differences for clinical use.

Dispersion Effect Based on Irradiation Dose and Position of QRD Microwave in Sealed Chamber (밀폐된 챔버의 QRD 마이크로파 조사용량과 위치에 따른 분산효과)

  • Kim, Jin Hyun;Han, Chung Su;Lee, Keun Woo;Lim, Kyoung Ho;Lee, Jae Hyun;Kim, Kyung Min;Ha, Yu Shin
    • Journal of Bio-Environment Control
    • /
    • v.23 no.1
    • /
    • pp.1-10
    • /
    • 2014
  • This study analyzed the efficiency and uniformity by measuring the temperature change depending on the position in the chamber with the use of QRD (quadratic residue diffusor) microwave capable of inducing even sterilization by changing wavelength phase difference and enhancing the effect on low power. The results are summarized as follows: When irradiating 7 kW of QRD microwave, the highest efficiency was obtained at 35 cm height and in the center of the chamber. When irradiating 5 kW of QRD microwave, high efficiency was obtained on the sides of the chamber. When irradiating 3 kW of QRD microwave to Magnetrons 1, 2 and 3, the temperature uniformity according to the position of the bars was similar in the position of Bar 1 and 2. When irradiating 3 kW of QRD microwave to Magnetrons 3, 4 and 5, the temperature increased by approximately 10 to 20% in Bar 3. When irradiating 5, 7 and 9 kW of magnetron, the average temperature during the irradiation time increased in a similar form independently of the position of the bars. On the other hand, the efficiency of the chamber's proper internal volume was not necessarily proportional to the irradiation dose. When irradiating 3 kW of magnetron for 60 120 and 180 seconds, the temperature increased by approximately 5 to 10 at the edge of the chamber according to the irradiation position of magnetron. The temperature distribution for each position in the horizontal plane was relatively uniform, and the temperature had a tendency to slightly increase at the edge. When irradiating 5, 7 and 9 kW of magnetron, the temperature relatively evenly increased independently of the position of the bars. It was thought necessary to increase the irradiation dose by approximately 10 to 20% by considering the difference in temperature rise according to the position of magnetron.

Dehydration of Foamed Fish (Sardine)-Starch Paste by Microwave Heating 1. Formulation and Processing Conditions (어육(정어러) 발포건조제품가공에 관한 연구 1. 원료$\cdot$첨가물의 배합 및 가공조건)

  • LEE Kang-Ho;LEE Byeong-Ho;You Byeong-Jin;SONG Dong-Suck;SUH Jae-Soo;JEA YOi-Guan;RYU Hong-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.15 no.4
    • /
    • pp.283-290
    • /
    • 1982
  • Sardine and mackerel so called dark muscled fish have been underutilized due to the disadvantages in bloody meat color, high content of fat, and postmortem instability of protein. Recent efforts were made to overcome these defects and develope new types of product such as texturized protein concentrates and dark muscle eliminated minced fish. Approach of this study is based on the rapid dehydration of foamed fish-starch paste by dielectric heating. In process comminuted sardine meat was washed more than three times by soaking and decanting in chilled water and finally centrifuged. The meat was ground in a stone mortar added Ivith adequate amounts of salt, foaming agent, and other ingredients for aid to elasticity and foam stability. The ground meat paste was extruded in finger shape and heated in a microwave oven to give foamed, expanded, and porous solid structure by dehydration. Dielectric onstant $(\varepsilon')$ and dielect.ic loss $(\varepsilon")$ values of sardine meat paste were influenced by wavelength and moisture level. Those values at 100 KHz and 15 MHz were ranged 2.25-9.86; 2.22-4,18 for E' and 0.24-19.24; 0.16-1.20 for E", respectively, at the moisture levels of $4.2-13.8\%$. For a formula for fish-starch paste preparation, addition of $20-30\%$ starch (potato starch) to the weight of fish meat, $2-4\%$ salt, and $5-10\%$ soybean protein was adequate to yield 4-5 folds of expansion in volume when heated. Addition of e99 yolk was of benefit to micronize foam size and better crispness. In order to provide better foaming and dehydration, addition of $0.2-0.5\%$sodium bicarbonate, foaming agent, was proper to result in foam size of 0.5-0.7 mm and foam density of $200-400\;/cm^2$ which gave a good crispness. Heating time was depended upon the moisture level of fish-starch paste. For a finger shaped paste (1.0cm. $D\times10cm.L$) heating for 150-200 sec. in a microwave oven (700W. 2.45GHz) was sufficient to generate foams, expand, and solidify the porous structure of fish-starch paste. When the moisture content was above $55\%$ browning and scorching was deepened due to over-expansion and over-heating whereas the crispness was hardened by insufficient expansion at lower moisture content. In quality evaluation of the product, chemical composition of $30\%$ starch and $3\%$ salt added product was moisture $8.8\%$, lipid $2.4\%$, carbohydrate $46.7\%$, protein $36.1\%$, and ash $6.0\%$. Eleven membered panel test evaluated that fish-starch paste was acceptable in color, crisp-ness, taste, except a trace of fishy odour which could be masked by the addition of spice extracts.

  • PDF

Development of an Solid Separation System for Pig Slurry (돈 슬러리용 고형물 분리시스템 개발)

  • 김민균;김태일;최동윤;백광수;박진기;양창범;탁태영
    • Journal of Animal Environmental Science
    • /
    • v.8 no.1
    • /
    • pp.9-16
    • /
    • 2002
  • This study was conducted to develope the new solid separating system which can be efficiently and economically removed the solid parts in high pollutants concentration of pig slurry. The pollutants concentration, BOD$_{5}$ , COD and SS of the slurry used in this study was 15,990($\pm$2,389)mg/l, 20,004($\pm$5,512)mg/l and 26,486($\pm$5,935)mg/l, respectively. After removal of solid part in slurry, the pollutants concentration, BOD$_{5}$, COD and SS was change into 5,617($\pm$690)mg/l, 5,553($\pm$633)mg/land 1,456($\pm$341)mg/l, respectively in the Fixed biological membrane tank. The reduction of the pollutants concentration of suspend liquid through membrane will be allowed to greatly improve the water purification by an Activated sludge method. This separating system consisted of a temporary storage, a circulating tank and a Fixed Biological membrane tank. A temporary storage which has a draining system of screw type and an aeration device played a tremendous role in draining the solid by filled an aeration of 0.3 l/min. A Fixed Biological membrane tank of which a styrofoam filled in a 2/3 volume as a Biological media was fixed by a stainless steel net (pore size : 0.5mm) to separate the liquid layer of influx in them. The separating system efficiency factors were the speed of screw motor, cycle number of slurries in a circulating tank and moisture contents of solid effluent through the screw path. Although the pollutants concentration was very variable in temporary storage, the final concentration of $BOD_5$ and SS, except COD of the suspended liquid in a Fixed biological membrane were not different regardless of cycle number of a circulating tank. Moisture contents of effluent from temporary storage was 73% under the speed 1 ppm of screw motor and 62% under the 1/4rpm of it.

  • PDF

Processing of Oleoresin Onion (양파 Oleoresin의 가공)

  • 최옥수;배태진
    • The Korean Journal of Food And Nutrition
    • /
    • v.10 no.3
    • /
    • pp.302-308
    • /
    • 1997
  • The purpose of this study was to investigate the extraction yield and quality stability as to the oleoresin process with large amount of onion at one time. The first mixed-product is raw onion juice which was reduced the compression and concentrated by Brix 70% mixed together wit the residue which was extracted and concentrated by ethanol, the second product manufactured by the same method above after the autoclaving with onion, and the other product is made by grinding by 50mesh to freeze-dried onion. Each of yields were 7.3, 9.1 and 0.8% and each of total sugar content was 616.4, 712.3 and 150.3mg/g. Therefore the product extracted by ethanol from freeze-dried onion was very low in yield and total sugar content. By the index of the overall odor intensity, contents of total pyruvate were 1,733.7, 520.6, and 2,716.5$\mu\textrm{g}$/g for each product. As a result, oleoresin onion processing that desired to use raw onion was remarkable for odor recovery. For the homogenous mixture with concentrate of onion juice and ethanol extract were emulsified by the addition of 2% of PGDR(polyglycerol condensed ricinoleate) and agitation(10,000rpm, 30 minutes). At this time, interfacial tension was 1.9 dyne/cm and the formation of emulsion was for 96.2% when left over 24hours in 6$0^{\circ}C$. When it was to be centrifuged(2,000$\times$G, 80 minutes) after emulsification, the volume of emulsion level without seperation was 92.6%, and very high in emulsification stability. The induced heating-oxidize with soy bean oil and sesame oil added to 1% of onion oleoresin, induction-time extension effect appeared with antioxidant activity that was applicable for 80.8~82.2% as to the effect of addition of 0.02% BHA.

  • PDF