• Title/Summary/Keyword: High-volume

Search Result 6,458, Processing Time 0.034 seconds

Effects of Dolomite Fine Aggregate and Cement-Based Materials on Viscosity Characteristics, Flow and Flow Time of High-Strength Grout (돌로마이트 잔골재와 시멘트계 재료의 용적 구성비가 고강도 그라우트의 점도 특성, 플로우 및 유하시간에 미치는 영향)

  • Jeong, Min-Gu;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.197-198
    • /
    • 2023
  • This study was conducted as part of research and development of high-strength grout. Accordingly, dolomite aggregate was used as a filler incorporated into the high-strength grout. Dolomite aggregate has a disadvantage of increasing the viscosity of the grout due to higher generation of fine powder than other aggregates. Accordingly, in this experiment, it was confirmed that the viscosity, flow time, and flow of high-strength grout change according to the volume composition ratio of dolomite aggregate and cement-based material. All experiments were conducted based on the Korean Industrial Standard KS F 4044, and the mixing factor was applied according to the composition ratio of the binder and the filler. In the experiment, the amount of fine powder contained in the dolomite aggregate rather than the silica sand used in the past is grasped, and after mixing with the grout accordingly, the mixture is proceeded to measure the viscosity in an unhardened state. In addition, the flow and flow time of the grout are evaluated according to the viscosity. As a result of the experiment, it was confirmed that the viscosity and flow time decreased and the flow increased as the volume composition ratio of the dolomite aggregate to the cement-based material increased.

  • PDF

Flexural and Impact Resisting Performance of HPFRCCs Using Hybrid PVA Fibers (하이브리드 PVA 섬유를 이용한 HPFRCCs의 휨 및 충격 성능 평가)

  • Kim, Young-Woo;Min, Kyung-Hwan;Yang, Jun-Mo;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.6
    • /
    • pp.705-712
    • /
    • 2009
  • HPFRCCs (high-performance fiber reinforced cementitious composites), which is relatively more ductile and has the characteristic of high toughness with high fiber volume fractions, can be used in structures subjected to extreme loads and exposed to durability problems. In the case of PVA (polyvinyl alcohol) fiber, it is noted by former studies that around 2% fiber volume fractions contributes to the most effective performance at HPFRCCs. In this study, flexural tests were carried out to evaluate the flexural behavior of HPFRCCs and to optimize mix proportions. Two sets of hybrid fiber reinforced high performance specimens with total fiber volume fraction of 2 % were tested: the first set prepared by addition of short and long PVA fibers at different combination of fiber volume fractions, and the second set by addition of steel. In addition, in order to assess the performances of the HPFRCCs against to high strain rates, drop weight tests were conducted. Lastly, the sprayed FRP was applied on the bottom surface of specimens to compare their impact responses with non-reinforcing specimens. The experimental results showed that the specimen prepared with 1.6% short fibers (REC 15) and 0.4% long fiber (RF4000) outperformed the other specimens under flexure, and impact loading.

Quantitative Estimation of Nonpoint Source Load by BASINS/HSPF (BASINS/HSPF 모형을 활용한 비점오염부하의 정량적 평가)

  • Lee, Jae-Woon;Kwon, Hun-Gak;Yi, Youn-Jeong;Yoon, Jong-Su;Han, Kun-Yeun;Cheon, Se-Uk
    • Journal of Environmental Science International
    • /
    • v.21 no.8
    • /
    • pp.965-975
    • /
    • 2012
  • Loading of NPS pollutant was valued through simulation by using BASINS/HSPF model which can simulate runoff volume in rainfall by time. For the verification of the model, it was analyzed the scatter diagram of the simulation value and measure value of water quality and runoff volume in Dongcheon estuary. Using the built model, a study on the time-variant characteristics of runoff and water quality was simulated by being classified into four cases. The result showed the simulation value was nearly same as that of the measured runoff. In the result of fit level test for measured value and simulated value, correlation of runoff volume was computed high by average 0.86 and in the water quality items, fit level of simulation and measurements was high by BOD 0.82, T-N 0.85 and T-P 0.79.

Quality Characteristics of Yellow Layer Cake Added with Sourdough Starter Powder (사워종 분말을 첨가한 옐로우 레이어 케이크의 품질 특성)

  • An, Hye-Lyung;An, Hee-Jung;Lee, Kwang-Suck
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.23 no.3
    • /
    • pp.349-356
    • /
    • 2013
  • When making a yellow layer cake, an existing chemical leavening agent, sourdough starter powder, was used instead of using baking powder in order to produce batter where the acid agent in the baking powder was reduced using baking soda. The control group had the lowest share of the batter and therefore had the highest specific volume. In a test group, the share of SP4 was low and therefore, the specific volume was high. In terms of physiochemical characteristics, the volume, symmetry and uniform index was high in SP4 in the test group. The control group had the highest moisture content followed by SP4. In terms of texture, the control group had the lowest hardness and highest springiness. In the test group, SP4 had the lowest hardness and highest springiness. The result of the sensory evaluation indicates that SP4 had the best taste and flavor. In terms of overall preference, SP4 showed significantly higher preference overall. However, it did not show any significant difference compared to the control group.

Adiabatic property of plywood wall panel (합판 벽체의 단열성능)

  • 박준철;홍순일
    • Journal of Korea Foresty Energy
    • /
    • v.21 no.2
    • /
    • pp.62-68
    • /
    • 2002
  • Adiabatic property of plywood wall panel was examined to evaluate their thermal conductivities. The amount of heat loss was investigated through overall heat transmission experiment. Styroform and grass wool showed less heat loss. However, yellowsoil board and laminated lumber showed high volume specific heat capacity. When the changes of indoor and outdoor temperature were checked in model house, wall manufactured with styroform and grass wool was affected easily by the changes of outdoor temperature. Yellowsoil, the mixed board of yellowsoil and sawdust, and laminated lumber, which have high volume specific heat capacity, were not affected much. The rates of overall heat transmission were much better in styroform and grasswool, but the adiabatic properties were much higher in yellowsoil board and the mixed board of yellowsoil and sawdust. The results showed that the insulating material can be developed using yellowsoil and wood, which are nature friendly materials.

  • PDF

A Novel Route to Realise High Degree of Graphitization in Carbon-carbon Composites Derived from Hard Carbons

  • Mathur, R.B.;Bahl, O.P.;Dhami, T.L.;Chauhan, S.K.
    • Carbon letters
    • /
    • v.4 no.3
    • /
    • pp.111-116
    • /
    • 2003
  • Carbon/carbon composites were developed using PAN based carbon fibres and phenolic resin as matrix in different volume fractions and heat treated to temperatures between $1000^{\circ}C$ to $2500^{\circ}C$. Although both the starting precursors are nongraphitizing hard carbons individually, their composites lead to very interesting properties e.g. x-ray diffractograms show the development of graphitic phase for composites having fibre volume fractions of 30~40%. Consequently the electrical resistivity of such composites reaches a value of $0.8\;m{\Omega}cm$, very close to highly graphitic material. However, it was found that by increasing the fibre volume fraction to 50~60%, the trend is reversed. Optical microscopy of the composites also reveals the development of strong columnar type microstructure at the fibre (matrix interface due to stress graphitization of the matrix. The study forcasts a unique possibility of producing high thermal conductivity carbon/carbon composites starting with carbon fibres in the chopped form only.

  • PDF

Optimization of the Layout of a Radioactive Waste Repository Based on Thermal Analysis (열해석에 기초한 방사성폐기물 처분장 배치 최적화)

  • Kwon Sangki;Choi Jong-Won;Cho Won-Jin
    • Tunnel and Underground Space
    • /
    • v.14 no.6 s.53
    • /
    • pp.429-439
    • /
    • 2004
  • The deep underground High Level Waste (HLW) repository to dispose of 36,000tons of spent fuel from the reactors in Korea needs about $4km^2$ repository area. In this study, the deep undergrond repository layout was optimized to minimize the excavation rock volume as well as underground repository area. In the optimization, the results from thermal analysis were used to define the influence of tunnel and deposition hole spacings on repository layout. The repository area and excavation rock volume could be reduced with longer disposal tunnel length. When it is necessary to reduce the repository area with satisfying thermal criteria, it is better to reduce tunnel spacing and increase deposition hole spacing. In contrast, the excavation rock volume can be reduced by increasing the tunnel spacing and decreasing the hole spacing.

The Spray Measurements of Gasoline, M85, E85, and LPG by a GDI Injector in a Constant Volume Chamber (정적챔버에서 GDI용 연료분사기의 가솔린, M85, E85 및 LPG 분무 계측)

  • Kim, S.S.
    • Journal of Power System Engineering
    • /
    • v.16 no.6
    • /
    • pp.5-10
    • /
    • 2012
  • Spray structures and penetration lengths of Gasoline, M85, E85, and LPG by a GDI 6-hole fuel injector were examined in a constant volume chamber. The chamber pressure was controlled at 0.1 MPa and 0.9 MPa. The effects of fuel injection pressure and chamber pressure on the spray structures and penetration lengths were investigated using the 2-dimensional Mie scattering technique. It was found that the sprays developed linearly till ASOI 1.7ms after start of injection and vortices were happened around jets on the way of spray development. And the high chamber pressure, 0.9 MPa kept the fuel sprays development down and the penetration length was reduced to about 55% compared with that of 0.1 MPa. In additions high pressure of fuel injection, 12 MPa increased the spray penetration length more about 7~10% than that of 7 MPa.

Dynamic analysis of non-symmetric FG cylindrical shell under shock loading by using MLPG method

  • Ferezghi, Yaser Sadeghi;Sohrabi, Mohamad R.;MosaviNezhad, Seyed M.
    • Structural Engineering and Mechanics
    • /
    • v.67 no.6
    • /
    • pp.659-669
    • /
    • 2018
  • The Dynamic equations in the polar coordinates are drawn out using the MLPG method for the non-symmetric FG cylindrical shell. To simulate the mechanical properties of FGM, the nonlinear volume fractions for radial direction are used. The shape function applied in this paper is a form of the radial basis functions, by using this function all the requirements for an effective and suitable shape function are established. Hence in this study, the multiquadrics (MQ) radial basis functions are exploited as the shape function governing the problem. The MLPG method is combined with the the Newmark time approximation scheme to solve dynamic equations in the time domain. The obtained results by the MLPG method to be verified are compared with the analytical solution and the FEM. The obtained results through the MLPG method show a good agreement in comparison to other results and the MLPG method has high accuracy for dynamic analysis of the non-symmetric FG cylindrical shell. To demonstrate the capability of the present method to dynamic analysis of the non-symmetric FG cylindrical shell, it is analyzed dynamically with different volume fraction exponents under harmonic and rectangular shock loading. The present method shows high accuracy, efficiency and capability to dynamic analysis of the non-symmetric FG cylindrical shell with nonlinear grading patterns.

Water Quality Characteristics of Nonpoint Pollutants based on the Road Type (도로 유형별 비점오염원의 수질특성)

  • Jang, Dae-Chang;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.631-636
    • /
    • 2009
  • This study has its intention to investigate the water quality of non-point source which is runoff from roads. We have classified and selected twelve sites as city road, industrial road, national road and mountain road by considering their traffic volume and surroundings. Water quality was analyzed based on BOD, COD, SS, T-N and T-P and the concentrations were measured by sampling after rainfall with the interval of 10 minutes, 20 minutes, and 30 minutes. BOD was the highest in city road with 57.6 mg/L and the lowest in mountain road with 45.0 mg/L. For COD, the highest concentration in industrial road was 146.5 mg/L and the lowest was in mountain road with 98.0 mg/L. The run off concentration of SS was up to maximum 630.0 mg/L (average 280.4 mg/L) which was remarkable compared to other types of road. It showed its lowest concentration in national road with 76.0 mg/L. T-N and T-P were the highest in industrial road and the lowest in mountain road. We found out that the runoff concentration was high with large amount of traffic volume and it seemed to be high in city road and industrial road where they were largely affected by their surroundings. Relatively, national road and mountain road seemed to show low concentration as they have less traffic volume and less affected by their surroundings.