• Title/Summary/Keyword: High-volume

Search Result 6,458, Processing Time 0.037 seconds

Capacity Evaluation of High Strength SFRC Beams according to Shear Span to Depth Ratio (전단경간비에 따른 고강도 SFRC보의 성능 평가)

  • Lee, Hyun-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.76-83
    • /
    • 2014
  • The purpose of this study is to evaluate the shear strengthening effect of steel fiber in high strength SFRC beams. For this purpose, 13th specimens are prepared and structural tests are performed. Testing variables are shear span to depth ratio, steel fiber volume fraction, shear strengthening ratio in 60 MPa SFRC concrete. From the reviewing of previous researches and analyzing of material and member test results, shear span to depth ratio 2.5 and steel fiber volume fraction 1.0% can be having a maximum strengthening effect in steel fiber. Proposed shear strength estimation equation, which is considering steel fiber strengthening and shear span to depth ratio effect, underestimate the shear capacity of high strength SFRC beams. Therefore a detailed research on strength characteristics of high strength SFRC beams are needed.

Stress-strain response on the confined normal and high-strength concrete cylinders containing steel fiber under compression

  • Purwanto;Antonius;Lisa Fitriyana
    • Advances in concrete construction
    • /
    • v.17 no.4
    • /
    • pp.233-243
    • /
    • 2024
  • The behavior of confined steel fiber-reinforced concrete (including confinement models) with compressive strengths ranging from normal to high strength is still rarely studied. This paper presents the results of an investigation of fifteen confined concrete cylinders containing steel fiber. The design parameters evaluated in the experiment included concrete compressive strength (covers normal to high strength), volume fraction of steel fiber and hoop spacing. The main objective of this study was to evaluate the behavior of confined steel fiber concrete by reviewing several design parameters, such as concrete strength (normal to high strength). It is then developed to be an analytical stress-strain expression for confined steel fiber concrete. The experimental program was carried out by making cylindrical specimens with a diameter of 100 mm and a height of 200 mm. The cylindrical test object is compressed in a monotonic uniaxial loading. Experimental results have shown steel fiber in concrete has an important role in increasing the compressive strength and strain of cylindrical concrete without steel fiber. In addition, the value of strength enhancement of confined concrete (K) along with increasing fiber fraction volume; which applies to normal to high-strength concrete. The value of K also increases if the compressive strength of the concrete tends to decrease and the spacing of the hoops is closer. The comparison of stress-strain behavior between the confined steel fiber concrete proposed by other researchers and the experimental results in general significantly different in post-peak response. The statistical analysis indicates that the value of Coefficient of Variation for the confinement model by Campione is the closest compared to other existing confinement models in predicting the values of K and Toughness Index. Furthermore, the analytic stress-strain expression of confined steel fiber concrete was developed by adopting and modifying several equations from the present models. The proposed analytical expression is then verified with the experimental results. The results of the verification show that the stress-strain behavior of confined steel fiber concrete is relatively close.

A Case Study of Supply Chain Management System of LG Siltron, Korea (실리콘 웨이퍼 공급사슬관리 시스템 구축에 관한 연구: (주) LG 실트론 사례를 중심으로)

  • Lee, Ho-Chang
    • IE interfaces
    • /
    • v.18 no.3
    • /
    • pp.234-246
    • /
    • 2005
  • A silicon wafer is a highly customized product made to the individual order varying its electrical and physical characteristics. Therefore, it has distinctive supply chain structure that is different from highly standardized commodity product. For high-volume/high-standardization product, it is general that a main stream of information flow initiated by the production planning of the manufacturers is usually directed to push both ways in a supply chain: upstream to the suppliers and downstream to the customers. Contrastingly, for low-volume/high-customization product, the information flow triggered by the fluctuating customer demand usually propagates upward to the suppliers through the manufacturers. Furthermore, for R &D based hi-technology product like silicon wafer, the interactive information feedback mechanism between manufacturer and customer, which is essential to the new product development process, is to be embedded in the supply chain. This article is a case study of supply chain management system of LG Siltron, a major Korean silicon wafer manufacturer. The SCM system entails special information structure fitting well typical high-variety/high-customization product, and also gives application possibilities to the R&D based high-technology product made to the individual customer order.

CFD computation of ship motions and added resistance for a high speed trimaran in regular head waves

  • Wu, Cheng-Sheng;Zhou, De-Cai;Gao, Lei;Miao, Quan-Ming
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.3 no.1
    • /
    • pp.105-110
    • /
    • 2011
  • Some research work on CFD computation of ship motions and added resistance in waves for a high speed trimaran is carried out in this paper. The governing equations, Reynolds Averaged Navier-Stokes and continuity equations are discretized by finite volume method. Volume of fluid method is adopted to deal with the nonlinear free surface. The incident waves are generated from the inflow boundary by prescribing a velocity profile resembling flexible flap wavemaker motions, and the outgoing waves are dissipated inside an artificial damping zone located at the rear part of the wave tank. In this paper, the computed results of ship motion and added resistance for a high speed trimaran are presented. The results of seakeeping experiment for the high speed trimaran carried out in CSSRC towing tank are also presented in this paper. Rather good agreements are shown between the computational and experimental results. The work in this paper provides a numerical tool for the study of seakeeping performance of high speed trimarans.

The Characteristics on the Hair Growth Using Diathermic Adjustable High-Frequency Generator (심부투열용 가변형 고주파 발생기를 적용한 발모 촉진 특성)

  • Shim, Ji-Young;Hong, Ji-Tae;Kim, Ho-Sung;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1896-1897
    • /
    • 2007
  • Medical equipment of high frequency has been presently applied to various parts of human body and novel treatment effects have been shown by it. Recently there are many cases that high frequency apparatus has been used in dermatology as the interest in beauty has been growing. Especially used in skin, blood volume is increased by keeping surface temperature of skin at around $43^{\circ}C$ and domodex folliculorum are treated by applying high electric field. It is the aspect we consider that increasing blood volume and domodex folliculorum treatment take effect on hair loss. In this study, high frequency electrotherapy apparatus was proposed to be applied to hair loss treatment. For that, human body was experimented with varying output voltage and frequency. The adjustable switching signal for treatment was obtained from 100[kHz] to 1000[kHz] by using DSP. Stable output specific was also obtained by feedback control to protect human body. The best hair growth conditions were the output voltage of 1.2[kV], the frequency of near 300[kHz] and the maximum current of 2[mA]. We apply this high frequency electrotherapy apparatus to two bald men, 46-year-old and 45-year-old. After treatment for a month they had thick and strong hair.

  • PDF

Prevalence of Urinary Incontinence, Single Voided Volume, Post Void Residual Volume, Daytime Frequency, and Nocturia in Women over 40 Years (40세 이상 여성의 요실금 유병률, 1회 배뇨량, 잔뇨량, 빈뇨 및 야뇨)

  • Kim, Ok Boon;Yoon, Haesang
    • Korean Journal of Adult Nursing
    • /
    • v.25 no.6
    • /
    • pp.679-689
    • /
    • 2013
  • Purpose: This prospective study was designed to investigate the prevalence of urinary incontinence (UI), voided volume, post void residual volume (PVRV), daytime frequency and nocturia in women over 40 years. Methods: The sample comprised of 302 women over 40 years.The study lasted from February 2008 to November 2009. Data about daytime frequency and nocturia were gathered from 48 hour bladder diary. Further, a PVRV was assessed through a bladder ultrasonography. Data were analyzed using the t-test, Mann Whitney test, Kruskal Wallis test and multiple regression. Results: Although the prevalence of UI among the women was as high as 70.5%, the perception rate of UI was as low as 10.8%.Single voided volume of women without or with UI was 223 mL or 198 mL (p<.001), respectively; PVRV, 25.8 mL or 23.6 mL (p=.055); daytime frequency, 5.89 or 6.96 (p<.001); nocturia, 0.99 or 1.23 (p=.040). Age (${\beta}$=0.19, p=.001), single voided volume (${\beta}$=-0.16, p=.006), and nocturia (${\beta}$=0.12, p=.034) were associated with UI. Conclusion: The prevalence of UI was found to be 70.5% among the participants. The assessment of single urinary volume and nocturia through a bladder diary lends support to identifying UI for women over 40 years.

Impact of hormonal therapy and other adjuvant therapies on contralateral breast volume change after implant-based breast reconstruction

  • Park, Jung Youl;Chung, Jae-Ho;Lee, Hyung Chul;Lee, Byung-Il;Park, Seung-Ha;Yoon, Eul-Sik
    • Archives of Plastic Surgery
    • /
    • v.45 no.5
    • /
    • pp.432-440
    • /
    • 2018
  • Background Adjuvant therapy after breast surgery, including tamoxifen or aromatase inhibitors, improves the postoperative outcomes and long-term survival of breast cancer patients. The aim of this study was to determine whether volume changes occurred in the contralateral breast during hormonal or other adjuvant therapies. Methods This study reviewed 90 patients who underwent unilateral breast reconstruction between September 2012 and April 2018 using tissue expanders and a permanent implant after the surgical removal of breast cancer. The volume of the contralateral breast was measured using a cast before the first (tissue expander insertion) and second (permanent implant change) stages of surgery. Changes in breast volume were evaluated to determine whether adjuvant therapy such as hormonal therapy, chemotherapy, and radiation therapy influenced the volume of the contralateral breast. Results The group receiving tamoxifen therapy demonstrated a significant decrease in volume compared with the group without tamoxifen (-7.8% vs. 1.0%; P=0.028). The aromatase inhibitor-treated group showed a significant increase in volume compared with those who did not receive therapy (-6.2% vs. 4.5%; P=0.023). There were no significant differences between groups treated with other hormonal therapy, chemotherapy, or radiation therapy. Conclusions Patients who received tamoxifen therapy showed a significant decrease in volume in the contralateral breast, while no significant change in weight or body mass index was found. Our findings suggest that we should choose smaller implants for premenopausal patients, who have a high likelihood of receiving tamoxifen therapy.

Scattered Light Representation in Accordance with the Material Using Scatterer Template in Volume Rendering (볼륨 렌더링에서 산란자 템플릿을 이용한 재질별 산란광 표현)

  • Lee, Byeong-Joon;Kwon, Koojoo;Shin, Byeong-Seok
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.5 no.12
    • /
    • pp.677-684
    • /
    • 2016
  • For realistic rendering volume to calculate the light effects as well as the shade is essential. In order to produce the high quality of the resulting image, it is necessary to represent a global illumination, and it should be considered an indirect effect of the direct impact and scattering of light. It requires a lot of resources in order to perform this operation and, in particular, is very expensive when large amounts of data to be rendered as a volume data is consumed. In this paper, we generate a scatterer template according to the physical laws for each material. Considering that each object having material property stores photons of the template based on the Lambert illumination model. When the volume rendering in this paper, using the photon is stored in the template, based on the voxel to be sampled within the examination volume occluded, and it represents the global illumination of the scattering. Because the materials produced by the template requires a less resource only if comprised of a complex material, a simple operation can be expressed within the scattering volume at a low cost through.

Evaluation of the Radiation Pneumonia Development Risk in Lung Cancer Cases

  • Yilmaz, Sercan;Adas, Yasemin Guzle;Hicsonmez, Ayse;Andrieu, Meltem Nalca;Akyurek, Serap;Gokce, Saban Cakir
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.17
    • /
    • pp.7371-7375
    • /
    • 2014
  • Background: Concurrent chemo-radiotherapy is the recommended standard treatment modality for patients with locally advanced lung cancer. The purpose of three-dimensional conformal radiotherapy (3DCRT) is to minimize normal tissue damage while a high dose can be delivered to the tumor. The most common dose limiting side effect of thoracic RT is radiation pneumonia (RP). In this study we evaluated the relationship between dose-volume histogram parameters and radiation pneumonitis. This study targeted prediction of the possible development of RP and evaluation of the relationship between dose-volume histogram (DVH) parameters and RP in patients undergoing 3DCRT. Materials and Methods: DVHs of 41 lung cancer patients treated with 3DCRT were evaluated with respect to the development of grade ${\geq}2$ RP by excluding gross tumor volume (GTV) and planned target volume (PTV) from total (TL) and ipsilateral (IPSI) lung volume. Results: Were admitted statistically significant for p<0.05. Conclusions: The cut-off values for V5, V13, V20, V30, V45 and the mean dose of TL-GTV; and V13, V20,V30 and the mean dose of TL-PTV were statistically significant for the development of Grade ${\geq}2$ RP. No statistically significant results related to the development of Grade ${\geq}2$ RP were observed for the ipsilateral lung and the evaluation of PTV volume. A controlled and careful evaluation of the dose-volume histograms is important to assess Grade ${\geq}2$ RP development of the lung cancer patients treated with concurrent chemo-radiotherapy. In the light of the obtained data it can be said that RP development may be avoided by the proper analysis of the dose volume histograms and the application of optimal treatment plans.

Improvement of Representative Value through Comparison of the Reliability of point detector : focusing on traffic volume (지점검지기 신뢰도 비교를 통한 대표치 생성 개선방안 : 구간 교통량을 중심으로)

  • Choi, Yoon-Hyuk;Lee, Yoon-Seok
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.5
    • /
    • pp.22-35
    • /
    • 2013
  • With the increase in image detectors, concerns about the reliability of traffic information are increasing. In this paper, we propose a method to generate reliable traffic volume using analysis of the point detector data as a representative value. Therefore, targeting expressway, we analyzed the difference in traffic volume collected by loop and image detector, and verified statistically using t-test, and finally analyzed the error rate compare to the real traffic volume. Analysis revealed that there was a statistically difference the traffic date collected by the loop detector and the image detector, in the same period, the same time, respectively. In addition, the difference between the actual traffic volume and traffic that have been collected in a loop detector was the lowest Therefore, creating a traffic volume of representative value, we proposed a method to use loop detector than the average traffic volume collected by each detector. It shows that it is more important to use one high-quality data rather than various low-quality data to produce a representative value.