• Title/Summary/Keyword: High-rise apartment building

Search Result 183, Processing Time 0.027 seconds

Shake-table responses of a low-rise RC building model having irregularities at first story

  • Lee, Han Seon;Jung, Dong Wook;Lee, Kyung Bo;Kim, Hee Cheul;Lee, Kihak
    • Structural Engineering and Mechanics
    • /
    • v.40 no.4
    • /
    • pp.517-539
    • /
    • 2011
  • This paper presents the seismic responses of a 1:5-scale five-story reinforced concrete building model, which represents a residential apartment building that has a high irregularity of weak story, soft story, and torsion simultaneously at the ground story. The model was subjected to a series of uni- and bi-directional earthquake simulation tests. Analysis of the test results leads to the following conclusions: (1) The model survived the table excitations simulating the design earthquake with the PGA of 0.187 g without any significant damages, though it was not designed against earthquakes; (2) The fundamental mode was the torsion mode. The second and third orthogonal translational modes acted independently while the torsion mode showed a strong correlation with the predominant translational mode; (3) After a significant excursion into inelastic behavior, this correlation disappeared and the maximum torsion and torsion deformation remained almost constant regardless of the intensity of the two orthogonal excitations; And, (4) the lateral resistance and stiffness of the critical columns and wall increased or decreased significantly with the large variation of acting axial forces caused by the high bi-directional overturning moments and rocking phenomena under the bi-directional excitations.

Estimation of the Potential Area for Roof Greening in Gyeonggi-do and Its Implications (경기도의 옥상녹화 가용면적 추정과 이의 정책적 함의)

  • Park, Eun-Jin;Nam, MiA;Kang, Gyui
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.15 no.1
    • /
    • pp.107-117
    • /
    • 2012
  • We estimated the potential area roof greening in Gyeonggi-do that will mitigate the heat island effect. The estimation was based on building age, roof shape, and building use which were recorded in the building register from "Sewoomteo, the Building Administration System in the Ministry of Land, Transport and Maritime Affairs. The estimated potential roof greening area in Gyeonggi-do was approximately $102.5km^2$ assuming that the buildings for residence, public, education(school), office, shopping mall are appropriate for roof greening. The area occupied by apartment buildings over six-story was 76.3% of the potential roof greening area 10.2% for individual houses, 5.9% for under five-story apartment buildings, and 3.7% for school buildings. The result indicated that it is residential buildings that we need to pay attention for roof greening, especially high-rise buildings over six-story. Greening of the whole estimated area, $102.5km^2$, in Gyeonggi-do will result in the increase of green space per capita by $8.74m^2$. This is 1.65 times greater than the area of current urban parks, and 1.97 times greater than the total area of neighborhood parks, children's parks, and pocket parks. Greening of the estimated roof area will increase green coverage of urban area by twice, adding to current green coverage of the urban areas, 11.3%, in 10 major cities. In particular, the effect of roof greening would be remarkable in inceasing the green space of Anyang City, Gwangmyeong City, and Guri City where neighborhood park area falls short.

A Study on Sustainable Greenspace based on Urban Remodeling Design of an Old Apartment Building

  • Myung Sik Lee;Seung Ryeol Min
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.2
    • /
    • pp.179-193
    • /
    • 2023
  • It is undeniable that urban greenspace is the soul of a city. Conventional urban greenspace such as parks, community gardens, playgrounds etc. located within a city reduce the negative effects of pollution, play a major role in the survival of the urban ecosystem, and promote healthy lifestyles. Today, 55% of the world's population lives in urban areas, which is expected to increase to 68% by 2050. Projections show that urbanization and the gradual migration to urban areas combined with the fast growth of the world's population, could add another 2.5 billion people to urban areas by 2050 and almost 90% of this increase will take place in Asia(UN, 2018). As a result, many plots in the cities are and will continue to be occupied with buildings to provide residential support to the increased population. This will dangerously decrease urban greenspaces. Moreover, worldwide, food crisis, energy crisis, and social crisis is posing a great threat to the existence of mankind. Additionally, the COVID - 19 has introduced a new lifestyle where from work culture to community configuration has drastically transformed. In this scenario, residential buildings will have to serve more than just providing privacy and shelter. As urban greenspaces are being occupied by concrete residential buildings, these buildings will have to compensate for the percentage of urban green they are destroying and the issues they are imposing in the process. The goal of this thesis is to design, architecturally define and, categorize comprehensive 'sustainable Greenspace'(S.G.S) for the multi-family housing scenario. These will be different than the conventional green (veranda, rooftop green) we commonly see in residential buildings. An old, dilapidated apartment building will be the target of remodeling to fulfill the purpose of this thesis.

Floor Impact Sound Pressure Level Characteristics by the Change of Reverberation Time in Mock-up Test Rooms (수음실 잔향시간 변화에 따른 중량 충격음 레벨 특성 - 실험실 환경을 중심으로 -)

  • Jeong, Jeong Ho;Lee, Byung Kwon;Yeon, Jun Oh;Jeon, Jin Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.4
    • /
    • pp.339-347
    • /
    • 2014
  • Floor impact sound in high-rise apartment building became one of social problems. A lot of civil complaints on floor impact sound occur continuously and the number of disputes between neighbors in small and aged apartment buildings is increasing. Interests on heavy-weight impact sound pressure level measurement and evaluation method is increased. Previous study reported that heavy-weight impact sound level was changed by the sound field condition of receiving reverberation chamber. In this study, heavy-weight impact sound pressure level change by the receiving sound field condition was measured in standard test facility and mock-up test room. These two experimental conditions were designed to simulate averaged living room of common apartment units. By the change of sound absorption power in receiving room, heavy-weight impact sound pressure level in most of frequency bands were changed in standard test facility and mock-up room. Normalized maximum sound pressure level regulated in ISO 16032 showed wider range of heavy/soft impact sound pressure level. Heavy/soft impact sound pressure level change was became smaller by the application of standardized maximum sound pressure level and ISO/CD 10140-3 Amd 2 method. In the case of standardized maximum sound pressure level, absolute sound pressure level changed. From these results, receiving sound field correction method regulated in ISO/CD 10140-3 Amd 2 is needed for the precision measurement and evaluation of heavy-weight impact sound.

Sensibility Evaluation of Components of Middle and High-rise Apartment Facade in Aesthetic Old Town Districts of Kyoto - Extraction of Component Combinations Using Rough Set Theory - (쿄토시 구시가지형미관지구에서 중고층 집합주택 입면의 구성요소에 대한 감성평가 - 러프 집합을 이용한 구성요소 조합의 추출 -)

  • Shon, Dong-Hwa
    • Journal of the Korean housing association
    • /
    • v.25 no.3
    • /
    • pp.105-114
    • /
    • 2014
  • Landscape zones have been designated as aesthetic old town districts across a wide range of Nakakyo-Ku and Shimokyo-Ku, city center of Kyoto, Japan. In these districts in which traditional structures and new buildings coexist, regulations of restriction on acts such as new building's heights, shapes, materials, and colors are carried out according to local governmental landscape ordinance based on Scenic Conservation Act. And yet, minimal fulfillment of the regulations according to different designer's subjective interpretation and principle of economy is rather creating abnormal shapes not harmonized with the traditional landscape. Thus, this study aims to extract combinations between form elements of middle and high rise apartment facade that affects 'harmony' and 'mismatch' in the districts by clarifying the social rules commonly implied based on intuitive judgments (sensibility evaluation) in which human experiential knowledge is involved. As research methods, the study first analyzes the form elements of the facade through a field survey, sets up a standard model through tasks of classification and segmentation and draws computer graphic images with 99 different patterns based on it. Based on these images, this study carries out sensibility evaluation and analyzes experimental data applying the rough set theory. As a result of the analysis, the combinations of form elements that affect harmony or mismatch act greatly when the colors and shapes of the pillars, positions and the patterns of the use of the first floor are combined.

Analysis of Occupational Accident Types in the Apartment Construction Sites using Multiple Correspondence Analysis (다중 상응 분석을 통한 아파트 건설현장 업무상 재해 유형 분석)

  • Ryu, Han-Guk;Son, Seunghyun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.3
    • /
    • pp.269-278
    • /
    • 2020
  • In this study, we analyzed the safety accidents that occurred in the apartment construction site and the correlations between the victims according to the type of work accidents through multiple correspondence analysis. There is a lack of disaster-related studies on apartment construction sites, the third most frequent building type in Korea, and most of them have used survey techniques. Therefore, the exploratory data analysis was conducted in industrial accident cause data, and derived the correlation analysis between each disaster victim through multiple correspondence analysis. The results of the study are summarized in two as follows. First, as the number of heights increased due to the high rise and complexity of apartments, the fall rate and mortality rate were high. In addition, deaths are mostly caused by very few experienced workers or those with more than 10 years of experience, resulting from safety training, lack of experience, and insensitivity to safety. Second, multi-correspondence analysis showed that most safety accidents can be prevented by wearing safety equipment, and following proper work process and its safety action. The key factors derived from this study can be used for safety education, supervision, and management in apartment construction sites.

Seismic Performance Evaluation of Apartment Buildings with Central Core

  • Lee, Joonho;Han, Seungho;Kim, Jinkoo
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.1
    • /
    • pp.9-19
    • /
    • 2014
  • In this study the seismic performances of reinforced concrete apartment buildings with Y- and box-shaped plans having central core are investigated. Three types of model structures are designed for each shape depending on the amount of shear partition walls: structures with all shear walls, structures with all columns except the core walls, and structures with shear walls and columns combined. The required amount of concrete to satisfy the specified design loads is the largest in the all shear wall structures, and decreases as more and more shear walls are replaced with columns. The amount of re-bars increased significantly in the flat plate structures. According to nonlinear static and dynamic analysis results, the structures with all shear walls and all columns turn out to have the largest and the smallest strengths, respectively. However it is observed that even the all-column structures with shear core have proper load resisting capacity for design level seismic load.

The study on the height standard and the slenderness ratio according to location types of Mixed-use Residential Tall buildings (초고층 주상복합건축물 입지유형에 따른 높이기준 및 세장비 제안에 관한 연구)

  • Sung, Lee-Yong;Kim, Yun-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.6
    • /
    • pp.2779-2788
    • /
    • 2012
  • The housing market is now difficult because of excess of the increase rate of housing and long-term recession but high-rise mixed-use buildings can mix residential facilities with various demand facilities focusing and they have the advantages to secure open space and excellent view by high-rise apartment. But there are problems by hindrance of skyline formation and height of buildings. Therefore, the purpose of this study is to suggest the height standard and the slenderness ratio to location types of Mixed-use Residential Tall buildings. For the method of the study, term arrangement through literature search and the precedent research survey were first done, the level of urban design and the details related to the height of buildings were done as the case research focusing on the 16 cases in Seoul. The following results were drawn by suggesting the height standard and the slenderness ratio by location type based on them. First, the height of mixed-use building by location type in the level of urban design gets higher starting from the secondary center of the city and can be suggested as from less than 150m to more than 200m. Second, the slenderness ratio shall be planned as more than 1:3 because the area of the ground level of mixed-use building is large unlike Mixed-use Residential Tall buildings and visual passage shall be placed so that unity of openness and group formation will be planned. Third, for the height related to Mixed-use Residential Tall buildings, amendment of the special architectural district system and the special law related to super high-rise buildings shall be enacted.

Analysis of Air Current Measurements at External Induction-Style Kitchen and Bathroom Vents (외기유인형 주방·욕실 배기구의 기류측정 분석)

  • Lee, Yong-Ho;Kim, Seong-Yong;Park, Jin-Chul;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.76-84
    • /
    • 2012
  • This study conducted experiments to measure air currents in an experimental building according to external conditions, types of induction ducts, and types of internal sockets by applying an external induction duct comprised of inducing openings and lines and induction units to the kitchen and bathroom vents at the rooftop of a super high-rise apartment building in order to help to improve the venting performance. The study also proposed the optimization of the external induction-style kitchen and bathroom vents capable of wind power generation. (1) As for air current distribution according to vent velocity changes, it increased the venting performance of the kitchen and bathroom by 1.0m/s at vent velocity of 2.0m/s or higher and allowed for wind power generation. (2)As for air current distribution according to external velocity changes, it increased the venting performance of the kitchen and bathroom by 1.2m/s at external velocity of 2.0m/s or higher and allowed for wind power generation. (3)As for air current distribution according to wind direction changes($0{\sim}180^{\circ}$), it was favorable for higher vent velocity when the angle between the external induction duct direction and prevailing wind direction was within ${\pm}30^{\circ}$. (4)As for air current distribution according to induction duct type, the[M1] type combining the inducing openings and lines with the induction units recorded the highest improvement effects in the kitchen and bathroom venting performance by increasing vent velocity by 46%. (5)As for air current distribution according to the changing types of internal sockets where the main ducts of the kitchen and bathroom are connected to the external induction ducts, the venturi tube type[Sv] increased vent velocity by 66% based on the smoothest external inflow.

A Checklist and Manual Developed to Review Fire Safety Facilities' Compliance with Fire Safety Requirements for Apartment Buildings (공동주택 소방시설 적법성 검토를 위한 화재안전규정 체크리스트 및 매뉴얼 개발)

  • Jeong, Soo-jin;Park, Yoo-na;Kim, Jae-jun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.19 no.6
    • /
    • pp.94-102
    • /
    • 2018
  • Recently, there is a growing need to review compliance with legal requirements to ensure fire safety as the number of fires caused by noncompliant fire safety facilities in high-rise buildings has increased. While there are a large number of apartment buildings in Korea, there is a lack of review on fire safety facilities' compliance with fire safety requirements. The reason for this lack of review despite apartment buildings causing deaths due to their structural features in the event of a fire, lies in the misinterpretation of legal provisions as the Building Act and the Fire Services Act are mixed up; a final inspection when fire safety facilities are unnecessarily installed or missing could result in significant losses in terms of finances and time. Therefore, this study developed a checklist that makes it possible to review mixed-up legal requirements for fire safety facilities simultaneously, and examined the importance and current level of each item through IPA (Importance Performance Analysis). Based on these results, this study intends to develop a manual that considers its applicability to construction practices and contribute to reducing construction companies' fire safety inspection risks.