• 제목/요약/키워드: High-pressure experiment

검색결과 989건 처리시간 0.034초

소동물 [F-18]FDG 양전자단층촬영 기법을 이용한 청각신경에서의 소리크기에 대한 적응효과 연구 (The Effect of Adaptation to Sound Intensity on the Neural Metabolism in Auditory Pathway: Small Animal PET Study)

  • 장동표
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권1호
    • /
    • pp.55-60
    • /
    • 2011
  • Although sound intensity is considered as one of important factors in auditory processing, its neural mechanism in auditory neurons with limited dynamic range of firing rates is still unclear. In this study, we examined the effect of sound intensity adaptation on the change of glucose metabolism in a rat brain using [F-18] micro positron emission tomography (PET) neuroimaging technique. In the experiment, broadband white noise sound was given for 30 minutes after the [F-18]FDG injection in order to explore the functional adaptation of rat brain into the sound intensity levels. Nine rats were scanned with four different sound intensity levels: 40 dB, 60 dB, 80 dB, 100 dB sound pressure level (SPL) for four weeks. When glucose uptake during the adaptation of a high intensity sound level (100 dB SPL) was compared with that during adaptation to a low intensity level (40 dB SPL) in the experiment, the former induced a greater uptake at bilateral cochlear nucleus, superior olivary complexes and inferior colliculi in the auditory pathway. Expectedly, the metabolic activity in those areas linearly increased as the sound intensity level increased. In contrast, significant decrease interestingly occurred in the bilateral auditory cortices: The activities of auditory cortex proportionally decreased with higher sound intensities. It may reflect that the auditory cortex actively down-regulates neural activities when the sound gets louder.

굴절식 크레인의 스핀들과 랙 기어 응력 해석 모델 개발 (Development of Analytical Model of Spindle and Rack Gear Systems for Knuckle Boom Crane)

  • 안준욱;이광희;유승규;조재상;이철희
    • 드라이브 ㆍ 컨트롤
    • /
    • 제14권2호
    • /
    • pp.23-29
    • /
    • 2017
  • In this study, a flexible multi-body dynamic simulation model of a knuckle boom crane is developed to evaluate the stress of spindle and rack gears under dynamic working conditions. It is difficult to predict potential critical damage to a knuckle boom crane if only the static condition is considered during the development process. To solve this issue, a severe working scenario (high speed with heavy load) was simulated as a boundary condition for testing the integrity of the dynamic simulation model. The crane gear model is defined as a flexible body so contact analysis was performed. The functional motion of a knuckle boom crane is generated by applying forces at each end of the rack gear, which was converted from hydraulic pressure measured for the experiment. The bending and contact stress of gears are theoretically calculated to validate the simulation model. In the simulation, the maximum stress of spindle and rack gears are observed when the crane abruptly stops. Peak impact force is produced at the contact interface between pinion and rack gears due to the inertia force of the boom. However, the maximum stress (bending/contact) of spindle and rack are under the yield stress, which is safe from damage. By using the developed simulation model, the experiment process is expected to be minimized.

Superhydrophobic nanostructured non-woven fabric using plasma modification

  • Shin, Bong-Su;Lee, Kwang-Reoul;Kim, Ho-Young;Moon, Myoung-Woon
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.320-320
    • /
    • 2011
  • We describe fabrication of superhydrophobic surface on non-woven fabric (NWF) having nano-hairy structures and a hydrophobic surface coating. Oxygen plasma was irradiated on NWF for nano-texuring and a precursor of HMDSO (Hexamethydisiloxane) was introduced as a surface chemical modification for obtaining superhydrophobicity using 13.56 MHz radio frequency-Plasma Enhanced Chemical Vapor Deposition (rf-PECVD). O2 plasma treatment time was varied from 1 min to 60 min at a bias voltage of 400V, which fabricated pillar-like structures with diameter of 30 nm and height of 150 nm on NWF. Subsequently, hydrophobic coating using hexamethyldisiloxane vapor was deposited with 10 nm thickness on NWF substrate at a bias voltage of 400 V. We evaluate superhydrophobicity of the modified NWF with sessile drop using goniometer and high speed camera, in which aspect ratio of nanohairy structures, contact angle and contact angle hysteresis of the surfaces were measured. With the increase of aspect ratio, the wetting angle increased from $103^{\circ}$ to $163^{\circ}$, and the contact angle hysteresis decreased dramatically below $5^{\circ}$. In addition, we had conducted experiment for nucleation and condensation of water via E-SEM. During increasing vapor pressure inside E-SEM from 3.7 Torr to over 6 Torr which is beyond saturation point at $2^{\circ}C$, we observed condensation of water droplet on the superhydropobic NWF. While the condensation of water on oxygen plasma treated NWF (superhydrophilic) occurred easily and rapidly, superhydrophobic NWF which was fabricated by oxygen and HMDSO was hardly wet even under supersaturation condition. From the result of wetting experiment and water condensation via E-SEM, it is confirmed that superhydrophobic NWF shows the grate water repellent abilities.

  • PDF

터널 화재시 물분무노즐에 의해 형성되는 제연수막의 연기층 확산방지성능에 관한 실험적 연구 (Experimental Research on Effects of Water Sprayed Curtain On Anti-diffusion of Fire Gases in Case of Tunnel Fire)

  • 박형주;최영상;지남용
    • 한국건축시공학회지
    • /
    • 제4권1호
    • /
    • pp.97-103
    • /
    • 2004
  • In case of a fire in road or railway tunnel it is always necessary to keep the escape condition as good as possible. Most of the victims of major fires in tunnels are because they couldn't leave the tunnel in time and were trapped by smoke, or rescue teams couldn't reach the place of the accident due to low visibility and high temperature. In spring 2003 a comprehensive field experiment was undertaken in a large scaled tunnel in Youngin City to test the effectiveness of a new water spray curtain system, designed to the air qualify inside of a tunnel in case of fire during passenger's escape to safe routes, In order to control the smoke propagation, fixed water sprayed nozzles were used to make water curtain system, which can be installed or hanging water piping line below ceiling. The experiment was accompanied by an extensive measurement campaign in order to measure temperature dropping effect and flow conditions as well as CO concentration for various water sprayed curtains produced by sprinkler heads or water spray nozzle. Eventually comparison analysis were undertaken to investigate the performance of water curtains under fixed water pressure. Therefore most effective water curtain system was presented on the basis of water droplet size in long tunnel.

보행 시 지지 기반 급변에 대한 하지 근신경의 반응 (Leg Muscle Activity from the Perturbation of the Support during Gait)

  • 신인식;천영진;서정석;최치선;남기정
    • 한국운동역학회지
    • /
    • 제17권3호
    • /
    • pp.147-154
    • /
    • 2007
  • This study's purpose is to investigate the effects on leg muscle activity caused by perturbation, using a trapdoor system during the support phase of gait for healthy adults (n = 6, height $177.5{\pm}5.5cm$, weight $81.0{\pm}9.5kg$, age $30.0{\pm}3.3yrs$). The trapdoor had the functional ability of causing inversion or eversion. The release time for the trapdoor was specified for two times, 0.3 and 0.5 seconds after heel contact. While altering these variables, EMG was recorded for the leg muscles (rectus femoris, biceps femoris, vastus lateralis, tibialis anterior, gastrocnemius, soleus). The following conclusions were derived. The steptime was longer for the 0.5s eversion than 0.3s inversion condition. So in order to regain stability after the perturbation the unsupporting leg reached forward rapidly. This quick reflex can be observed through the center of pressure (COP) and its rapid change in direction. The gastrocnemius was activated throughout the total experiment. There was a low amount of activity recorded in the rectus femoris, vastus lateralis and tibialis anterior except for the condition of inversion 0.3s. For most of the conditions, the highest average EMG peak values were recorded during the condition of inversion 0.3s. The iEMG patterns were similar for the conditions of inversion 0.3s and eversion 0.3s. To cope with the rapid change in these conditions, the biceps femoris was activated. During the experiment except for the condition of normal gait, the activity of the soleus and gastrocnemius was relatively high. Therefore, to prevent injury from perturbation of the lower leg strengthening of the soleus and gastrocnemius is required. Likewise to prevent injury to the thigh strengthening for the biceps femoris.

자가증기 가압시스템 개발과제 및 모사시험설비 구성 (Tasks for Development of Autogenous Pressurization System and Construction of Test Equipment)

  • 김철웅;유지성;지상연;박재성
    • 한국추진공학회지
    • /
    • 제27권1호
    • /
    • pp.49-57
    • /
    • 2023
  • 자가증기 가압시스템은 저비용, 고신뢰도의 장점으로 차세대 재사용 발사체들의 추진기관에 널리 채택되고 있다. 자가증기 가압시스템은 구조가 간단하나 탱크 내부에서 일어나는 열과 물질의 전달과정에 대한 이해가 필요하다. 이러한 이유로 자가증기 가압시스템의 모사시험을 구상하였다. 모사시험설비는 해외 가압시험설비 사례와 전문가의 자문을 기반으로 구성하였는데, 실제 자가증기 가압시스템과 달리 추진제 탱크를 단열하여 외부환경에 의한 영향을 배제하고자 하였으며, 열과 물질 전달현상의 연구의 편의를 위하여 가압가스 공급라인과 추진제 배관을 분리하였다. 제작된 자가증기가압 모사시험설비를 이용하여 극저온 추진제에서 가압가스의 응축현상, 헬륨을 이용한 가압과 증발된 추진제를 이용한 자가증기가압의 효율성 비교, 그리고 자가증기의 온도에 따른 가압능력을 평가할 수 있다.

농약의 물리화학적 특성연구 (I) Captafol의 수용성, 가수분해, 증기압, 옥탄올/물 분배계수 (Study on Physicochemical Properties of Pesticide. (I) Water Solubility, Hydrolysis, Vapor Pressure, and n-Octanol/water Partition Coefficient of Captafol)

  • 김정한;이성규;김용화;김균
    • Applied Biological Chemistry
    • /
    • 제40권1호
    • /
    • pp.71-75
    • /
    • 1997
  • 농약의 물리화학적 특성에 관한 연구의 일환으로 captafol의 수용성, 가수분해, 증기압, 분배계수를 표준 측정기법 인 미국 EPA와 OECD 방법에 준하여 측정하였다. 수용성은 $25^{\circ}C$ 조건에서 2.24 ppm이었으며, 가수분해에 의한 반감기는 $25^{\circ}C$에서 77.8시간(pH 3.0), 6.54시간(pH 7.0), 0.72시간(p班 8.0)으로 나타나 알칼리 조건에서 불안정한 화합물임을 확인하였다. 산성조건에서의 반감기는 온도에 영향을 받지 않았으나, 중성, 알칼리 조건에서의 반감기는 $40^{\circ}C$에서 매우 짧았다. 가수분해 실험의 표준 대조물질인 diazinon을 이용하여 실험한 결과 본 연구실에서 수행한 가수분해 실험은 적합한 것으로 판정되었다. Captafol은 상온에서 증기압 ($8.27{\times}10^{-9}\;torr,\;20^{\circ}C$)이 높지 않으므로 휘발에 의하여 대기환경에 영향을 미칠 가능성은 없으리라 예상되었고, log P=6.94-(4401.6/T)라는 관계식을 유도할 수 있었다. Captafol은 옥탄올/물 분배계수치가 높아(Kow=1,523) 먹이연쇄를 통한 생물농축의 가능성이 예상되나 가수분해가 빠르기 때문에 비록 captafol이 수계에 노출된다고 하여도 분해가 빠르게 일어나 어류 생체내에 농축되어 인체에까지 영향을 미칠 가능성은 매우 낮을 것으로 사료되었다.

  • PDF

응집제의 주입량 및 압력변화에 따른 여과특성 (Filtration characteristic of quantity of coagulant and variable pressure)

  • 이성호;임택준;조준형
    • Journal of Forest and Environmental Science
    • /
    • 제17권1호
    • /
    • pp.29-36
    • /
    • 2001
  • 제지공업은 다른 공업에 비해 용수 소비량이 많고 이에 따라 폐수의 배출량도 많은 용수 다소비 산업이다. 제지폐수의 처리는 물리적, 화학적, 처리로 1차 처리를 하고 생물학적 처리로 2차 처리를 한 후, 필요에 따라 고도처리를 행하여 재이용 하거나 방류하는 시스템으로 구성되어 있다. 물리적 처리 중 응집침전법에 의한 처리방법은 생물학적 처리의 전 단계로서 처리가 불량할 경우 생물학적 처리 시스템의 부하량이 높아져 처리율의 저하를 유발한다. 또한 가장 비용이 적게 드는 처리방법이므로 응집침전에서 많은 오염물을 제거하는 것이 비용 면에서도 유리하다고 할 수 있다. 제지공장의 폐수에는 Fiber, Filler, 그 밖의 유기용매가 포함되어 있으며, 폐수량이 많기 때문에 그 만큼의 설비자본과 운영비가 소요된다. 그러므로 폐수의 양을 줄이고 그 안에 함유된 여러 가지 물질들을 적은 비용으로 효율적으로 제거하는 방법이 필요하게 된다. 본 실험은 제지폐수를 보다 효율적으로 여과하는 방법을 찾고자 함에 있어 가압 여과시험을 채택하여 응집제의 종류 및 첨가량 그리고 압력의 변화를 주면서 여과의 특성 실험을 하였다. 폐수내의 섬유나 Filler 등은 미세하게 분산되어 콜로이드성 물질이 되는데 이것은 여과시에 여재 위에 쌓여 여과 조작을 방해한다. 여기에 응집제를 첨가하게 되면 분산된 콜로이드 입자를 응집제가 표면에 사슬처럼 붙어 안정화시킨다. 즉, 침전성과 여과성이 향상되고 SS가 떨어진다. 본실험에 사용된 응집제는 $FeCl_3$, Alum, $CaCl_2$, Polymer 이며, 네 가지 응집제를 0.01g, 0.03g, 0.05g 씩 첨가(폐수 100mL에 대해)하고 압력을 49, 98, 147, 196 kPa로 변화시키면서 실험을 하였다. 이와 같은 여러 변화의 실험을 통하여 각 단위 시간 별로 여과되는 여액량을 측정하여 여과 속도 및 탁도 등을 측정하였다.

  • PDF

소아치과 환자의 깊은 진정시 호기가스 제거 방법에 따른 호흡대역에서 Nitrous Oxide 농도 변화 (THE NITROUS OXIDE CONCENTRATION IN BREATHING ZONE ACCORDING TO SCAVENGING METHODS DURING DEEP SEDATION OF PEDIATRIC DENTAL PATIENTS)

  • 이충원;윤형배
    • 대한소아치과학회지
    • /
    • 제30권1호
    • /
    • pp.124-131
    • /
    • 2003
  • 최근 치과영역에서 아산화질소(Nitrous Oxide)를 이용한 의식하 진정과 필은 진정의 임상 적용이 증가함에 따라 수술실 또는 진료실 환경이 아산화질소로 오염될 수 있다. 비록 낮은 농도일지라도 장기간 아산화질소에 노출 시 자연유산의 증가, 기형아 출산 증가, 말초신경염 및 운동신경 장애 등과 같은 부작용을 초래하는 것으로 알려져 있다. 호흡시 흡입 공기의 구성성분의 변화를 줄 수 있는 구강 입구로부터 반경 12 inch 이내 영역인 호흡대역(Breathing zone)에서 아산화질소 농도는 치료자에게 영향을 주게된다. 소아 환자에게 주로 적용되는 깊은 진정시는 환자의 구호흡양에 따라서 호흡대역에서 아산화질소의 농도에 영향을 주게되므로, 깊은 진정시 구호흡의 증가 원인을 규명하기 위해 잉여가스 배출 방법을 달리하여 호흡대역에서 아산화질소 농도를 측정 비교하여 다음과 같은 결론을 얻었다. 1. 깊은 진정을 시행하는 경우 호흡대역에서 아산화질소의 농도는 공급 가스량 증가에 의한 비기도 저항 증가에 따라 증가하는 양상을 보였다. 호흡대역에서 아산화질소 농도 증가는 구호흡 증가에 의한 것이며 구호흡은 비기도 저항과 관계가 있다 할 수 있다. 즉 비기도 저항 증가는 구호흡의 한 요인이라 할 수 있다. 음압을 사용한 호기가스 배출장치를 사용하여도 NIOSH에서 권장하는 허용치에는 미치지 못하였고 이를 위해서는 팬이나 다른 제거 장치가 함께 사용되어야 한다. 2. 구강편도의 크기는 기도 저항이 적은 경우 즉 음압을 사용하여 호기가스 제거하는 경우 구호흡에 영향을 주었다.

  • PDF

다중관형 CO2 급탕열교환기의 열적성능에 대한 해석연구 (An analytical study on the thermal performance of multi-tube CO2 water heater)

  • 장근선;최연성;김영재
    • 한국산학기술학회논문지
    • /
    • 제17권8호
    • /
    • pp.23-30
    • /
    • 2016
  • 본 연구에서는 길이 4.5 m와 7.5 m의 다중관 $CO_2$ 급탕 열교환기의 열전달 및 압력강하 특성을 ${\epsilon}-NTU$ 방법을 사용하여 해석하고 결과를 기존의 실험 데이터와 비교하였다. 급탕 열교환기는 쉘측에 물이 흐르고 8개로 구성된 내부 튜브에 $CO_2$를 흐르게 하였으며 열전달 효율을 최대화하기 위하여 대향류로 설계하였다. 각 노드에 대한 물과 $CO_2$ 냉매의 유동에 대한 에너지 평형 방정식은 단면분할법을 이용하여 해석하였다. 열전달율 계산값은 실험값과 ${\pm}5%$ 범위 내에서 잘 일치하였다. 반면에 물의 출구온도는 물 유량이 증가함에 따라 거의 선형적으로 감소하며 계산값과 실험값은 ${\pm}3%$ 내에서 일치하였다. 결과에서 열전달율은 4.5 m와 7.5 m 급탕 열교환기 모두 물 유량 또는 $CO_2$ 입구온도가 증가함에 따라 거의 선형적으로 증가하였으며, 반면에 물 유량이 증가함에 따라 물의 출구온도는 선형적으로 감소하였다. $CO_2$ 압력강하 계산값과 실험값은 $CO_2$가 고유량일 때 5 % 내에서 잘 일치한 반면에 $CO_2$가 저유량일 때 실험값이 약 20 % 높게 나타났다.