• Title/Summary/Keyword: High-power transformer

Search Result 1,046, Processing Time 0.032 seconds

Dynamic Property of Ground Overvoltage Relay in Large Turbine Generator (대용량 터빈발전기에서 접지과전압 계전기의 동작 특성)

  • Kim, Hee-Dong;Lee, Young-Jun;Kim, Byong-Han;An, Joon-Young;Chae, Gyu-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1044-1047
    • /
    • 1999
  • This paper deals with the dynamic property of ground overvoltage relay in large turbine generator. Relay operation is based on detecting the fundamental voltages originating from the generator. Calculations of fault voltage and current are reviewed for the neutral ground resistance. The frequency, ampitude and waveform of individual harmonics were measured using power quality analyzer and memory hi-corder at the secondary side of ground potential transformer. The ac and dc high-potential tests were applied to evaluate the condition of generator, main and auxiliary transformer, isolated phase bus, potential transformer, surge capacitor and arrester.

  • PDF

Analysis of the Ultrasonic Signals by the Partial Discharge and Noises from the Transformer (변압기 부분방전과 노이즈에 의한 초음파 신호 분석)

  • Gwon, Dong-Jin;Jeong, Gil-Jo;Jin, Sang-Beom;Gwak, Hui-Ro
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.8
    • /
    • pp.354-360
    • /
    • 2002
  • The partial discharge detecting method using the ultrasonic technique has been investigated to monitor the insulation ageing of a transformer. However, the result of the studies on the ultrasonic technique for detecting of partial discharge in the operating transformer is not enough yet to utilize. This paper presents the analysis of the ultrasonic signals due to the partial discharge in a model transformer and the corona in air at a shielded high voltage room. In addition, the ultrasonic signals due to the vibration from the core, operation of the cooling pump, the fan and the OLTC at the 345㎸ power transformer, were analyzed and corona noise from overhead transmission line in 345㎸ substation were measured to remove the electrical and mechanical noises from the transformer. Furthermore, ultrasonic signal due to the partial discharge in the 154㎸ power transformer with in $C_2$$H_2$ gas warning condition was measured. The inside of the transformer was examined with care. which confirms the existence of the partial discharge source.

A Novel Prototype of Duty Cycle Controlled Soft-Switching Half-Bridge DC-DC Converter with Input DC Rail Active Quasi Resonant Snubbers Assisted by High Frequency Planar Transformer

  • Fathy, Khairy;Morimoto, Keiki;Suh, Ki-Young;Kwon, Soon-Kurl;Nakaoka, Mutsuo
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.89-97
    • /
    • 2007
  • This paper presents a new circuit topology of active edge resonant snubbers assisted half-bridge soft switching PWM inverter type DC-DC high power converter for DC bus feeding power plants. The proposed DC-DC power converter is composed of a typical voltage source-fed half-bridge high frequency PWM inverter with a high frequency planar transformer link in addition to input DC busline side power semiconductor switching devices for PWM control scheme and parallel capacitive lossless snubbers. The operating principle of the new DC-DC converter treated here is described by using switching mode equivalent circuits, together with its unique features. All the active power switches in the half-bridge arms and input DC buslines can achieve ZCS turn-on and ZVS turn-off commutation transitions. The total turn-off switching losses of the power switches can be significantly reduced. As a result, a high switching frequency IGBTs can be actually selected in the frequency range of 60 kHz under the principle of soft switching. The performance evaluations of the experimental setup are illustrated practically. The effectiveness of this new converter topology is proved for such low voltage and large current DC-DC power supplies as DC bus feeding from a practical point of view.

Forward DC/DC Converter Using Planar Transformer (평면변압기적용 Forward DC/DC Converter)

  • Choi S. H.;Park J. Y.;Park S. S.;Kim E. S.;Lee H. Y.;Kim H. S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.149-153
    • /
    • 2003
  • In this paper, the design and implementation of a high power(300W) forward converter using a planar transformer is presented. The overall size and volume of the converter is decreased by replacing a planar transformer in stead of using a conventional winding transformer. Due to the decreased size and volume, power density of the applied forward converter is increased. Also, in this paper, the 300W ZVS forward converter with active clamp snubber circuit is compared to the 300W hard switching forward converter.

  • PDF

High power density bidirectional power conversion circuit with small size and small volume inductor. (작은 크기와 부피의 인덕터를 가지는 고밀도 양방향 전력 변환 회로)

  • Lim, DongBin;Kim, Dasom;Kang, Kyung-Soo;Roh, Chung-Wook
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.317-318
    • /
    • 2015
  • 본 논문에서는 배터리 충 방전을 위한 고 승압이 가능하며 작은 인덕터를 가진 새로운 양방향 DC-DC 컨버터를 제안한다. 제안 회로는 인덕터를 N1:N2 턴비의 Transformer로 사용하고 Transformer 사이에 스위치, 다이오드를 추가 하였다. 이는 방전 모드 동작에서 입력 전류가 두 개의 Transformer로 전류가 나누어 흐르도록 하였다. 기존 DC-DC 컨버터는 입력 전류가 하나의 인덕터로 흐름으로써 고 전력 시스템에서 높은 전류에 의해 인덕터의 크기가 필요 이상으로 커지는 문제점이 있다. 이를 위해 기존 양방향 회로 방식보다 Transformer의 크기가 0.5배 정도 작은 회로를 제안 하였다. 그리고 기존 방전 Boost 회로는 최대 3배 이상의 승압이 안 되지만 제안 회로에서는 3배 이상의 고 승압이 가능하다. 이를 모의실험 및 실험을 통해 타당성을 검증하였다.

  • PDF

Development and Characteristics of Detector for Open of Current Transformer Secondary Terminal (변류기 2차측 개방 보호장치 개발 및 특성)

  • Choi, Sang-Won;Song, Ki-Chan
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.4
    • /
    • pp.20-25
    • /
    • 2007
  • Instrument transformers are a safe measurement device designed to measure high voltage and large current. A current transformer(CT) is a type of instrument transformer designed to provide a current in its secondary winding proportional to the current flowing in its primary. It is commonly used in metering and protective relaying in the electrical power industry where it facilitates the safe measurement of large current. But, care must be taken that the secondary of a current transformer is not disconnected from its load while current is flowing in the primary, as this will produce a dangerously high voltage across the open secondary, and may permanently affect the accuracy of the transformer. Especially, industrial disaster such as an electric shock and/or a burn accident occurs occasionally by disregard of warning or attention. In this paper, we developed the detector for open of current transformer secondary terminal, and which was tested by the Korea Electrotechnology Research Institute. Test results show that Current Transformer secondary Open Detector(CTOD) interrupted within one second electronically when the 2nd terminal of current transformer opened.

Investigation and Estimation of Transformer Load Factor for Rationalization of Transformer's Efficiency (변압기 효율 적정화를 위한 변압기 부하율 조사 및 추정)

  • Kim, Chong-Min;Kim, Young-Seog;Gil, Hyoung-Jun;Shong, Kil-Mok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.1
    • /
    • pp.96-101
    • /
    • 2016
  • In this paper, We investigate the number of 795 transformer in the private electrical facilities and analyze the annual load factor. The results show that the annual load factor of transformer is 20.16% in manufacturing industry, education services(school) is 9.59%, retail and wholesale services is 19.68%, resort and leisure industry is 10.93%, office building is 13.10%, and apartment houses is 14.69%. Education services, resort and leisure industry are being operated with a very low annual load factor. The relatively small capacity of less than 500kVA transformer also been analyzed that is being operated with a low load factor. Therefore, In order to minimize the power loss of the transformer, it is advisable to complement the Transformer Efficiency Management system to be designed the efficiency is good transformer when the load is low. Analysis results will be used as the basis for the provision of transformer efficiency management system and be used High-efficiency transformers promotion system.

Study on the Characteristics of Constant Voltage Transformer for the changes of the circuit parameters (정전압 변압기의 회로정수에 따른 특성 변화에 관한 연구)

  • Joo Hyeong-Gil;Han Jae-Won
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.627-629
    • /
    • 2001
  • The constant voltage transformer(CVT) is a voltage regulator that has a high reliability, a good short circuit characteristic, a high input power factor, and a relative immunity to lightning strike. Moreover, this has a good line regulation without a voltage feedback control. In this paper, the characteristics of CVT for the changes of input voltage and other circuit parameters are investigated.

  • PDF

Energy Efficient Alloy Design in PSN-PMN-PZT Ceramic System for Piezoelectric Transformer Application (고효율 압전 트랜스포머용 PSN-PMN-PZT 조성 설계)

  • Choi Yong-Gil;Ur Soon-Chul;Yoon Man-Soon
    • Korean Journal of Materials Research
    • /
    • v.15 no.12
    • /
    • pp.814-817
    • /
    • 2005
  • In order to enhance energy efficiency in high electric conversion devices such as Power transformers, which need to have high power properties, an alloy design approach in $Pb(Zr,Ti)O_3(PZT)$ base ceramic system was attempted $0.03Pb(Sb_{0.5}Nb_{0.5})O_3-0.03Pb(Mn_{1/3}Nb_{2/3})O_3-(0.94-x)PbTiO_3-xPbZrO_3$[PSN-PMN- PZT] ceramics were synthesized by conventional bulk ceramic processing technique. To improve power properties, the various Zr/Ti ratio was varied ]lear their morphotropic phase boundary (MPB) composition of PSN-PMN-PZT system and their effects on subsequent piezoelectric and dielectric properties for the transformer application at high power were systematically investigated using an impedance analyzer. Microstructure and phase information were characterized using X-ray diffractometer (XRD), a scanning electron microscope (SEM) and others. When the Zr/Ti ratio was 0.415/0.465, the value of $Q_m\;and\;k_p$ were shown to reach to the maximum, indicating that this alloy design can be a feasible composition :or high power transformer.

Bi-polar High-voltage Pulse Generator Using Semiconductor switches (반도체 스위치를 이용한 양방향 고압 펄스 발생기)

  • Kim J.H.;Ryu M.Y.;Jung I.W.;Shenderey S.;Kim J.S.;Rim G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.291-293
    • /
    • 2003
  • A semiconductor switch-based fast hi-polar high voltage pulse generator is proposed in this paper The proposed pulse system is made of a thyristor based-rectifier, DC link capacitor, a push-pull resonant inverter, a high voltage transformer. secondary capacitor, a high voltage IGBT & diode stacks, and a variable capacitor. The proposed system makes hi-polar high voltage sinusoidal waveform using resonance between leakage inductance of the transformer and secondary capacitor and transfers energy to output load at maximum of the secondary capacitor voltage. Compared to previous hi-polar high voltage pulse power supply using nonlinear transmission line, the proposed pulse power system using only semiconductor switches has simple structure and gives high efficiency

  • PDF