• Title/Summary/Keyword: High-power transformer

Search Result 1,046, Processing Time 0.029 seconds

A High Efficiency LLC Series Resonant Converter (고효율 LLC 직렬공진 컨버터)

  • Kang, Sung-In;Yoon, Kwang-Ho;Kim, Eun-Soo;Park, Jun-Ho;Lim, Dae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.424-427
    • /
    • 2007
  • The LLC series resonant converter with a LLT (Inductor-Inductor-Transformer) transformer for PDP power supply is presented. LLT transformer used to combine the inductor and transformer into one unit has the increased leakage inductance in the primary and secondary due to the winding method and the use of the gaped core. The increased leakage inductance in the primary and secondary of LLT transformer can be impacted on the DC voltage gain characteristics of LLC series resonant converter. In this paper, DC gain characteristics and the experimental results of the LLC series resonant converter with a LLT transformer are verified on the Math-CAD simulation based on the theoretical analysis and the 600W experimental prototype.

  • PDF

Electrical Properties of High Power Step Down Multilayer Piezoelectric Transformer using Low Temperature Sintering PMN-PNN-PZT Ceramics (저온소결 PMN-PNN-PZT 세라믹스를 이용한 고출력 강압용 적층 압전변압기의 전기적 특성)

  • Yoo, Ju-Hyun;Kim, Kook-Jin;Paik, Dong-Soo;Yoon, Hyun-Sang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.4
    • /
    • pp.332-336
    • /
    • 2007
  • In this study, multilayer piezoelectric transformer was manufactured using the PMN-PNN-PZT ceramic and then the electrical characteristics were investigated according to the variations of frequency and load resistance. The voltage step-up ratio of multilayer piezoelectric transformer showed the maximum value at the vicinity of 75 kHz and increased according to the increase of load resistance. When the output impedance coincided with the load resistance, the multilayer piezoelectric transformer showed the temperature rise of less than $20^{\circ}C$ at the output power of 20 W. As the results, the multilayer piezoelectric transformer manufactured at low co-firing temperature of $940^{\circ}C$ using PMN-PNN-PZT ceramics could be stably driven as the step-down transformers.

Electrical Insulation Design of a 154 kV Class HTS Transformer (154 kV급 고온초전도 변압기의 전기절연 설계)

  • Cheon, H.G.;Kwag, D.S.;Choi, J.H.;Kim, S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.1
    • /
    • pp.53-56
    • /
    • 2007
  • In the response to the demand for electrical energy, much effort was given to develop and commercialize high temperature superconducting (HTS) power equipment has been made around the world. Especially, a HTS transformer is one of the most promising devices. Recently, Korea Polytechnic University and Gyeongsang National University are developing a power distribution and transmission class HTS transformer that is one of the 21st century superconducting frontier projects in Korea. For the development of 154 kV class HTS transformer, the cryogenic insulation technology should be established. We have been analyzed insulation composition and investigated electrical characteristics such as the breakdown of $LN_2$, barrier, kapton films, and the surface flashover of FRP in $LN_2$. Furthermore, we are going to compare with measured each value and apply the value to the most suitable insulating design of the HTS transformer.

AC-DC Converter using the PFC Inductor and LLC Resonant Transformer with an Integrated Magnetic Core (하나의 코아로 집적화된 PFC 인덕터와 LLC 공진변압기 적용 AC-DC 컨버터)

  • Noh, Young-Jae;Kang, Cheol-Ha;Saran, Meas;Kim, Eun-Soo;Won, Jong-Seob;Kim, Dong-Hee;Lee, Young-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.3
    • /
    • pp.262-272
    • /
    • 2015
  • An integrated two-in-one transformer applicable to PSUs for a 120 W LED TV is proposed. This transformer comprises a PFC inductor and an LLC transformer placed and integrated on an E-I-E type magnetic core. Performance is evaluated by observing the coupling coefficients of the proposed two-in-one transformer under various air gap topologies. Among the topologies studied, an integrated transformer with centered air gap shows stable operational characteristics with a minimized mutual coupling (interference). Furthermore, applicability of the proposed integrated transformer to PSUs for a 120 W LED TV is studied from the viewpoint of integrating different magnetic components into one core, resulting to low weight, low cost, and high power density.

A Study on the Insulating Properties of Pressboard for High Voltage Transformer Applied the Mold of Eddy Current Loss (와전류 손실을 적용한 금형으로 제조된 초고압 변압기의 프레스보드의 절연 특성 연구)

  • Suh, Wang-Byuck
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.8
    • /
    • pp.508-512
    • /
    • 2015
  • Some insulating materials are tested and analyzed with variables to obtain the reliable pressboard which is located to core and coil of high voltage transformer. The high voltage transformer is used in electrical power system and operating reliability. Optimization possibility of pressboard shape including electrical insulation performance could be achieved by analysis simulation. Using insulating pressboard, which is made by mold applied eddy current loss, it could be measured the influences of moisture content for electrical properties. As a result, it is to contribute to improve the performance and ensure the reliability of the pressboard by investigating electrical strength according to the variation oil temperature. In addition pressboard thickness is important design factor to ensure electrical strength in high voltage transformer.

A Study of Current Transformer for High Power Testing Facility (대전력 시험설비용 변류기 특성에 관한 연구)

  • Jung, Heung-Soo;La, Dae-Ryeol;Kim, Sun-Koo;Roh, Chang-Il;Kim, Won-Man;Lee, Dong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.735-737
    • /
    • 2002
  • A current transformer for measuring current in high power testing laboratory is exactly proportional to the current including D.C component due to electrical transient. But, current transformer isn't designed to consider D.C component, therefore when data acquisition system measure that current. the error is increased because of saturation of core. This paper describe the concept of transient factor and how to design the current transformer.

  • PDF

10kVA High $T_c$ Superconducting Power Transformer with Double Pancake Winding (더블펜케익 권선형 10kVA 고온초전도 변압기)

  • Lee, H.J.;Cha, G.S.;Lee, J.K.;Choi, K.D.;Ryu, K.W.;Hahn, S.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.934-936
    • /
    • 2000
  • This paper presents the design of a double pancake winding type high $T_c$ superconducting power transformer In the design of the transformer. BSCCO-2223 tape was considered as the conductor. Double pan cake winding was adopted in order to easy the construction of the winding and to lessen the leakage reactance of the transformer. Numerical calculation was used to decide the arrangement of the double pan cake winding. Room temperature bore type cryostat has been constructed and its heat loss was estimation.

  • PDF

A Study of the Three Port NPC based DAB Converter for the Bipolar DC Grid (양극성 직류 배전망에 적용 가능한 3포트 NPC 기반의 DAB 컨버터에 대한 연구)

  • Yun, Hyeok-Jin;Kim, Myoungho;Baek, Ju-Won;Kim, Ju-Yong;Kim, Hee-Je
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.4
    • /
    • pp.336-344
    • /
    • 2017
  • This paper presents the three-port DC-DC converter modeling and controller design procedure, which is part of the solid-state transformer (SST) to interface medium voltage AC grid to bipolar DC distribution network. Due to the high primary side DC link voltage, the proposed converter employs the three-level neutral point clamped (NPC) topology at the primary side and 2-two level half bridge circuits for each DC distribution network. For the proposed converter particular structure, this paper conducts modeling the three winding transformer and the power transfer between each port. A decoupling method is adopted to simplify the power transfer model. The voltage controller design procedure is presented. In addition, the output current sharing controller is employed for current balancing between the parallel-connected secondary output ports. The proposed circuit and controller performance are verified by experimental results using a 30 kW prototype SST system.

AC Loss Effects on the Design of HTS Windings for 1 MVA Power Transformer

  • Kim, Jong-Tae;Kim, Woo-Seok;Kim, Sung-Hoon;Choi, Kyeong-Dal;Hong, Gye-Won;Joo, Hyeong-Gil;Hahn, Song-Yop
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.4
    • /
    • pp.32-36
    • /
    • 2004
  • AC loss is one of the important parameters in HTS (High Temperature Superconducting) AC devices. Among the HTS AC power devices, the transformer is an essential part in electrical power system. But, AC loss is one of the most serious problems of the HTS transformer, especially with pancake windings, because high alternating magnetic field is applied perpendicularly to the surface of BSCCO wire in HTS windings of that, comparing with the other HTS AC power devices. For the reason above the calculation of AC loss generated in the HTS windings should be carried out in advance when designing the HTS transformer. In the paper we performed study for optimization of winding design to minimize the magnetization loss of HTS winding such as the spaces between pancake windings and operating temperature of HTS wire. The calculation of the AC loss was accomplished by 2-demensional Finite Element Method.

Fabrication and Test of Multiple HTS Wire with Transposition for HTS Power Transformer

  • Kim, Woo-Seok;Park, Chan;Choi, Kyeong-Dal
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.2
    • /
    • pp.34-37
    • /
    • 2008
  • According to the recent design of an HTS (High Temperature Superconducting) power transformer whose capacity is hundreds MVA, the rated current values of the low voltage side are generally over thousands amps. Considering the performance of the recent HTS wires, it is inevitable to use several HTS wires in parallel for large rated current. Lots of stacked HTS wires were fabricated and tested so far, and the results have showed that we have to transpose each wire in order to reduce the AC losses as well as to increase the current capacity. But many development programs about HTS transformers reveal that the transposition of the several wires during the winding process is quite difficult not only in case of the layer windings but also in case of the pancake type ones. So, we need transposed multiple HTS wire which we can handle like single wire or cable for the HTS windings of large capacity power transformer. We fabricated several kinds of samples of multiple HTS wire with transposition to apply it to the HTS windings of power transformer. The electrical characteristics such as critical currents or AC losses are analyzed by experiments in case by case. Finally we present the best design of a multiple HTS wire for power transformer.