• 제목/요약/키워드: High-isolation

검색결과 1,953건 처리시간 0.04초

FxLMS 알고리즘을 적용한 하이브리드 미소진동 절연장치의 절연성능 평가 (Performance Evaluation of Hybrid Vibration Isolator using FxLMS algorithm)

  • 이대은;박지용;한재흥
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.173-174
    • /
    • 2014
  • Vibration disturbances generated by reaction wheels may cause serious problems in high precision pointing spacecraft missions. Implementation of vibration isolator is a practical solution to meet the high pointing stability requirement placed on precision payloads. In this paper, development of hybrid vibration isolator that combines passive and active component is described. Vibration isolation performance of the developed isolator is evaluated using reaction wheel disturbance model. Hybrid isolation results obtained using FxLMS algorithm show clear improvement compared to the results obtained using only passive means.

  • PDF

Computation of Beam Stress and RF Performance of a Thin Film Based Q-Band Optimized RF MEMS Switch

  • Singh, Tejinder
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권4호
    • /
    • pp.173-178
    • /
    • 2015
  • In lieu of the excellent radio frequency (RF) performance of microelectromechanical system ( MEMS) switches, these micro switches need higher actuation voltage for their operation. This requirement is secondary to concerns over the swtiches’ reliability. This paper reports high reliability operation of RF MEMS switches with low voltage requirements. The proposed switch is optimised to perform in the Q-band, which results in actuation voltage of just 16.4 V. The mechanical stress gradient in the thin micro membrane is computed by simulating von Mises stress in a multi-physics environment that results in 90.4 MPa stress. The computed spring constant for the membrane is 3.02 N/m. The switch results in excellent RF performance with simulated isolation of above 38 dB, insertion loss of less than 0.35 dB and return loss of above 30 dB in the Q-band.

Effects of High Damping Rubber Bearing on Horizontal and Vertical Seismic Responses of a Pressurized Water Reactor

  • Bong Yoo;Lee, Jae-Han;Koo, Gyeong-Hoi
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(2)
    • /
    • pp.1021-1026
    • /
    • 1995
  • The seismic responses of a base isolated Pressurized Water Reactor (PWR) are investigated using a mathematical model which expresses the superstructure as lumped mass-spring model and the seismic isolator as an equivalent spring-damper. Time history analyses are performed for the 1940 E1 Centre earthquakes in both horizontal and vertical directions. In the analysis, structural damping of 5% is used for the superstructure. The isolator damping ratios of 12% for horizontal and 5% for vertical directions are used. The acceleration responses in base isolated PWR superstructure with high damping rubber bearings are much smaller than those in fixed base structure in horizontal direction. However, the vertical acceleration responses at the superstructure in the base isolation system are amplified to some extent. It is suggested that the vertical seismic responses at the superstructure should be reduced by introducing a soft vertical isolation device.

  • PDF

High-Performance Reversible Data Hiding with Overflow/Underflow Avoidance

  • Yang, Ching-Yu;Hu, Wu-Chih
    • ETRI Journal
    • /
    • 제33권4호
    • /
    • pp.580-588
    • /
    • 2011
  • This paper proposes reversible data hiding using minimum/maximum preserved overflow/underflow avoidance (MMPOUA). The proposed MMPOUA algorithm consists of three main steps. These steps include the minimum (or maximum) pixel fixing, pixel squeezing, and pixel isolation. The aims of pixel fixing are to keep the minimum (or maximum) pixel of a host block unchanged and prevent the occurrence of overflow/underflow. Both the pixel squeezing and pixel isolation supply hiding storage while keeping the amount of distortion low. The proposed method can avoid (or significantly reduce) the overhead bits used to overcome overflow/underflow issues. At an embedding rate of 0.15 bpp, the proposed algorithm can achieve a PSNR value of 48.52 dB, which outperforms several existing reversible data hiding schemes. Furthermore, the algorithm performed well in a variety of images, including those in which other algorithms had difficulty obtaining good hiding storage with high perceived quality.

3kW 멀티스트링 태양광 인버터 설계 및 시뮬레이션 (3kW multi-string photovoltaic inverter design and simulation)

  • 이종인;유병규;유권종;김흥근
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.371-376
    • /
    • 2009
  • The Power Conditioning System is Power Transfer System which make array DC current to the Grid sinusoidal current. These are Low Frequency Transformer Inverter Type, High Frequency Transformer Inverter Type and Transformer-less Type. Low Frequency Transformer Type has a Excellent Isolation property, but doesn't have competitiveness in Size and Cost. Also High Frequency Transformer Type has a good Isolation property but there are many steps in Power transfer Switching. Nowadays, Transformer-less Type inverter change a transformer to DC/DC Converter which is small and cost effective. In this paper shown the DC/DC Converter Transformer-less Type multi-string inverter design and simulation. The Control Algorithm will be introduced and Simulation was accomplished.

  • PDF

Analysis, Design, and Implementation of a Single-Phase Power-Factor Corrected AC-DC Zeta Converter with High Frequency Isolation

  • Singh, Bhim;Agrawal, Mahima;Dwivedi, Sanjeet
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.243-253
    • /
    • 2008
  • This paper deals with the analysis, design, and implementation of a single phase AC-DC Zeta converter with high frequency transformer isolation and power factor correction(PFC) in two modes of operation, discontinuous current mode of operation(DCM), and continuous current mode of operation(CCM). A Digital Signal Processor(DSP) based implementation is carried out for validation of the Zeta converter developed design in discontinuous mode of operation. A comparison of both modes of operation is presented for a 1kW power rating from the point of view of steady state and dynamic behavior, power quality, simplicity, control technique, device rating, and converter size. The experimental results of a developed prototype of Zeta converter are presented for validation of the developed design. It is observed that CCM is most suitable for higher power applications where it requires some complex control and sensing of the additional variables.

Numerical Feasibility Study for a Spaceborne Cooler Dual-function Energy Harvesting System

  • Kwon, Seong-Cheol;Oh, Hyun-Ung
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제18권3호
    • /
    • pp.579-587
    • /
    • 2017
  • Spaceborne cryocoolers produce undesirable micro-vibration disturbances during their on-orbit operation, which are a primary source of image-quality degradation for high-resolution observation satellites. Therefore, to comply with the strict mission requirement of high-quality image acquisition, micro-vibration disturbances induced by cooler operation have always been subjected to an isolation objective. However, in this study, we focused on the applicability of energy harvesting technology to generate electrical energy from micro-vibration energy of the cooler and investigated the feasibility of utilizing harvested energy as a power source to operate low-power-consumption devices such as micro-electromechanical system (MEMS) devices. A tuned mass damper (TMD)-type electromagnetic energy harvester combined with a conventional passive vibration isolator was proposed to achieve this objective. The system performs the dual functions of electrical energy generation and micro-vibration isolation. The effectiveness of the strategy was evaluated through numerical simulations.

Co-located and space-shared multiple-input multiple-output antenna module and its applications in 12 × 12 multiple-input multiple-output systems

  • Longyue Qu;Haiyan Piao;Guohui Dong
    • ETRI Journal
    • /
    • 제45권2호
    • /
    • pp.203-212
    • /
    • 2023
  • In this study, we developed a co-located and space-shared multiple-input multiple-output (MIMO) antenna module with a modular design and high integration level. The proposed antenna pair includes a half-wavelength loop antenna and a dipole-type antenna printed on the front and back sides of a compact modular board. Owing to their modal orthogonality, these two independent antenna elements are highly self-isolated and free of additional decoupling components, even though they are assembled at the same location and within the same space. Thus, the proposed antenna is attractive in 5G MIMO systems. Furthermore, the proposed co-located and space-shared MIMO antenna module was employed in a 5G smartphone to verify their radiation and diversity performances. A 12 × 12 MIMO antenna system was simulated and fabricated using the proposed module. Based on the results, the proposed module can be employed in large-scale MIMO antenna systems for current and future terminal devices owing to its high integration, compactness, simple implementation, and inherent isolation.

갑상선암 환자에서 고용량 방사성요오드 치료 후 유효반감기에 대한 연구 (A Study on the Effective Half-life after the High Dose Radioactive Iodine (131I) Therapy for Thyroid Cancer Patients)

  • 김성철;권다영;김용민
    • 한국방사선학회논문지
    • /
    • 제11권7호
    • /
    • pp.597-603
    • /
    • 2017
  • 고용량 $^{131}I$ 치료는 분화갑상선암으로 인한 갑상선전절제술을 받은 환자에게 보편적으로 시행되어 왔다. 고용량 $^{131}I$ 치료를 하는 경우 환자로부터 일반인이 받게 되는 피폭선량을 선량한도 이내로 제한하기 위해 환자를 일정 기간 동안 격리하여야 한다. 유효반감기는 환자로부터 가족들이 얼마나 피폭되는지 계산하거나 격리기간을 결정하는데 중요한 값이다. 이에 본 연구에서는 NM670 SPECT/CT를 이용해 고용량 $^{131}I$ 치료환자의 유효붕괴상수, 유효반감기, 격리기간을 도출하였다. 본 연구를 통해 고용량 $^{131}I$ 치료환자의 유효반감기를 도출하였고, 체내에 잔류 방사능량이 퇴원기준인 1.2 GBq 에 도달하는 시간을 확인하였다. 또한 치료선량별 유효반감기를 비교하였을 때 유의한 차이가 없었으나, 격리기간은 치료선량이 커질수록 격리기간이 길어지는 것을 확인할 수 있었다. 전처치 유형별 유효반감기를 비교하였을 때 rhTSH 환자군과 THW 환자군의 유효반감기가 유의한 차이를 보이지 않았으나, 격리기간은 rhTSH 환자군이 THW 환자군 보다 짧게 나타났다. 이는 치료선량의 차이로 인해 격리기간이 짧아진 것으로 판단된다. 따라서 현행 의료보험체계(rhTSH 사용 시 3.7 GBq 이하에서 보험적용)가 유지된다면, 전처치 유형별로 구분하여 현행 격리기간(2박 3일)보다 더 이른 시간에 환자를 퇴원시킬 수 있을 것이다.

VHF 대역용 광대역 고전력 스위치 설계 (Design of VHF-Band Wideband High-Power Switch)

  • 이병남;박동철
    • 한국전자파학회논문지
    • /
    • 제19권9호
    • /
    • pp.992-999
    • /
    • 2008
  • 본 논문은 $20{\sim}100$ MHz 범위의 VHF 대역에서 $50{\mu}s$ 이내에 2 kW 이상의 고전력 신호를 제어할 수 있는 SPST(Single Pole Single Throw) PIN 다이오드 스위치의 설계 및 제작에 관하여 기술하였다. 고전력 스위치 설계에 필요한 설계 요소를 고찰하였고, 시뮬레이션을 통해 설계된 스위치의 삽입 손실, VSWR 및 격리도 특성이 목표 값을 만족함을 확인하였다. 또한, 실험을 통하여 최대 $20{\mu}s$ 이하의 빠른 스위칭 속도로서 2 kW의 고전력 취급이 가능함을 알 수 있었고, 0.2 dB 이하의 삽입 손실, 1.17:1 이하의 VSWR 및 40 dB 이상의 격리도 특성을 얻었다.