• Title/Summary/Keyword: High-capacity

Search Result 8,087, Processing Time 0.038 seconds

The Electrochemical Characteristics of Surface-modified Carbonaceous Materials by tin Oxides and Copper for Lithium Secondary Batteries

  • Lee, Joong-Kee;Ryu, D.H.;Shul, Y.G.;Cho, B.W.;Park, D.
    • Carbon letters
    • /
    • v.1 no.3_4
    • /
    • pp.170-177
    • /
    • 2001
  • Lithium intercalated carbon (LIC) are basically employed as an anode for currently commercialized lithium secondary batteries. However, there are still strong interests in modifying carbon surface of active materials of the anode because the amount of irreversible capacity, charge-discharge capacity and high rate capability are largely determined by the surface conditions of the carbon. In this study, the carbonaceous materials were coated with tin oxide and copper by fluidized-bed chemical vapor deposition (CVD) method and their coating effects on electrochemical characteristics were investigated. The electrode which coated with tin oxides gave the higher capacity than that of raw material. Their capacity decreased with the progress of cycling possibly due to severe volume changes. However, the cyclability was improved by coating with copper on the surface of the tin oxides coated carbonaceous materials, which plays an important role as an inactive matrix buffering volume changes. An impedance on passivation film was decreased as tin oxides contents and it resulted in the higher capacity.

  • PDF

A Study on the H??S Removal with Utilization of Seashell Waste(II) - The Characteristics of Sulfided Reaction Using Fixed Bed Reactor- (패각 폐기물을 이용한 $H_2S$ 제거에 관한 연구(II) -고정층 반응기를 이용한 황화반응특성)

  • 김영식
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.3
    • /
    • pp.86-90
    • /
    • 2003
  • In this study, lots of methods have been studing to utilize energy and decrease contaminated effluents. There has been great progress on IGCC (Integrated gasification combined cycle) to reduce thermal energy losses. The following results have been conducted from desulfurization experiments using waste shell to remove H$_2$S. Fixed bed desulfurization experiments, to obtain basic data for scale-up was indicated. Oyster was the best among the various sorbents, like the results of TGA. Especially, H$_2$S removal efficiency of uncalcined oyster was the highest. When use oyster as desulfurization sorbents, calcination process was not needed. Thus, high desulfurization efficiency would be expected. Fixed bed reactor experiments were indicated particle size of sorbents. These had influenced on desulfurization capacity. As smaller particle size was found better desulfurization capacity. Large capacity difference was found between 0.613 mm and 0.335 mm. But, differences between 0.335 mm and 0.241 mm was relatively small. As bed temperature increased, H$_2$S removal capacity increased. Therefore, both particle size and bed temperature should be considered to remove H$_2$S by sorbents.

Reheating of Semi-Solid Material Using Multi-Capacity Induction Heating System (다출력 유도 가열 시스템에 의한 반용융 소재의 재가열)

  • 정홍규
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.03b
    • /
    • pp.199-202
    • /
    • 1999
  • Many processing times for fabricating complex shaped parts by near net shape process such as thixoforming or semi-solid forming, are required due to the time for die design, induction heating and forming process. Therefore, for the thixoforming process, multi-capacity induction heating process is very important due to the reduction of the processing time and cost. It is indispensable to adopt a power-time heating pattern which manages to conciliate complete eutectic melting at the core with limited overheating at the periphery. The total reheating time is thus dependent on billet diameter; in inches$(pm20%)$. Typically, high frequency is used for the rapid reheating of the billet to the eutectic temperature range and low frequency for the remelting of the desired fraction of liquid and for the radial homogeneization of the liquid fraction. So in this study, the multi-capacity induction heating conditions of ALTHIX 86s alloy to reduce the processing time and cost would be proposed. The suitability of multi-capacity induction heating conditions would be verified through the comparison to Garat's data.

  • PDF

Electrode Characteristics of the (Mm)Ni5-Based Hydrogen Storage Alloys ((Mm)Ni5계 수소저장합금의 전극 특성)

  • Han, D.S.;Choi, S.J.;Chang, M.H.;Choi, J.;Park, C.N.
    • Journal of Hydrogen and New Energy
    • /
    • v.6 no.1
    • /
    • pp.35-41
    • /
    • 1995
  • The MmNi-based alloy electrode was studied for use as a negative electrode in Ni-MH battery. Alloys with $MmNi_5-_xM_x$(M=Co,Al,Mn) composition were synthesized, and their electrode charateristics of activation rate, temperature dependence, electrode capacity and cycle life were investigated. With increasing Al content and decreasing Mn content in the alloys, the discharge capacity increased while the cycle life decreased. As x in $MmNi_5-_xM_x$ increased from 1.5 to 2.0, decreasing the Ni content, the discharge capacity, the low temperature property and the rate capability decreased. However its cycle life was improved. Increasing Co content resulted in a prolonged cycle life and decrease of high rate discharge capacity. It can be concluded that the most promising alloy in view of discharge capacity and cycle life is $MmNi_{3.5}Co_{0.7}Al_{0.5}Mn_{0.3}$.

  • PDF

Evaluation on Deformation Capacity of CFT Square Columns subject to Constant Axial and Cyclic Lateral Loads (일정축력과 반복 수평력을 받는 콘크리트충전 각형강관 기둥의 변형성능 평가)

  • Ji, Ku Hyun;Choi, Sung Mo;Kim, Dong Kyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.2 s.45
    • /
    • pp.209-219
    • /
    • 2000
  • Concrete Filled steel Tube(CFT) Column has an excellent structural capacities in accordance with an interaction effect between the steel tube and concrete. Recently, CFT structure has been focussed on a structural system for a high-rise buildings. The purpose of this study is to evaluate a strength and deformation capacity of CFT square columns subjected to constant axial and cyclic lateral load. The test parameters are diameters to thickness ratio of steel tube, axial load ratios, concrete strengths, load applying types and whether or not filled concrete. Total sixteen specimens are fabricated to clarify the energy absorbtion capacity of CFT columns. Experimental results are summarized for maximum strength, initial stiffness and deformation capacity.

  • PDF

Structural performance of novel SCARC column under axial and eccentric loads

  • Zhou, Chunheng;Chen, Zongping;Li, Junhua;Cai, Liping;Huang, Zhenhua
    • Steel and Composite Structures
    • /
    • v.37 no.5
    • /
    • pp.503-516
    • /
    • 2020
  • A novel spiral confined angle-steel reinforced concrete (SCARC) column was developed in this study. A total of 16 specimens were prepared and tested (eight of them were tested under axial loading, the other eight were tested under eccentric loading). The failure processes and load-displacement relationships of specimens under axial and eccentric loads were examined, respectively. The load-carrying capacity and ductility were evaluated by parametric analysis. A calculation approach was developed to predict the axial and eccentric load-carrying capacity of these novel columns. Results showed that the spiral reinforcement provided enough confinement in SCARC columns under axial and low eccentric loads, but was not effective in that under high eccentric loads. The axial load-carrying capacity and ductility of SCARC columns were improved significantly due to the satisfactory confinement from spirals. The outer reinforcement and other construction measures were necessary for SCARC columns to prevent premature spalling of the concrete cover. The proposed calculation approach provided a reliable prediction of the load-carrying capacity of SCARC columns.

Capacity Analysis of VoIP over LTE Network (LTE 무선 네트워크에서 Voice over IP 용량 분석)

  • Ban, Tae Won;Jung, Bang Chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.11
    • /
    • pp.2405-2410
    • /
    • 2012
  • The 4th generation mobile communication system, LTE, does not support an additional core network to provide voice service, and it is merged into a packet network based on all IP. Although Voice service over LTE can be supported by VoIP, it will be provided by the existing 3G networks because of the discontinuity of LTE coverage. However, it is inevitable to adopt VoIP over LTE to provide high quality voice service. In this paper, we investigate the capacity of VoIP over LTE. Our results indicate that spectral efficiency can be significantly improved as channel bandwidth increases in terms of VoLTE capacity. In addition, we can achieve higher VoLTE capacity without decreasing control channel capacity.

Fire Loading Analysis of Underground Box Structure with Considering of Concrete Spalling II : Load Carrying Capacity (박리를 고려한 지하박스구조물의 화재하중해석 II : 내하력)

  • Lee, Gye-Hee;Kim, Sun-Hoon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.4
    • /
    • pp.485-492
    • /
    • 2007
  • In this study, based on the temperature distribution and the spalling histories those obtained in the companion paper, the thermal stress and moments of underground box structure were estimated. Additionally, the ultimate sectional moment considering with the thermal nonlinearities of material were estimated and the load carrying capacity of underground box structure was also obtained. As results, the load carrying capacity of negative moment part was dominated by thermal moment that come from thermal gradient of the section. However, the load carrying capacity of the positive moment part was rules by the yield stress of rebar that exposed to the high temperature induced spalling phenomena.

Environmental Conservation and Sustainable Pusan Development Strategy (환경보전과 지속가능한 부산의 도시개발방안)

  • Hwang, Young-Woo;Song, Kyo-Ook;Yhang, Wii-Joo
    • Journal of Environmental Science International
    • /
    • v.6 no.3
    • /
    • pp.195-203
    • /
    • 1997
  • Pusan has experienced some different paths of urbanization and industrialization compared to other cities. and has faced the problem of over-saturation In enoronmental capacity. Pusan needs to fond out sustainable development strategies based on Agenda 21 by UNCED In 1992 to secure urban renewal. Therefore. Pusan's sustainable development strategies focus on the 1)research on envlronmental capacity and reasonable population accommodation 2)supp1y of basic enoronmental facilities for the human settlement 3)protection and efficient management of environmental pollution 4)saving and control of energy and other resources S)independent and stable euecution of plan based on biological relation 6)harmony between nature and urban spatial organization. In addition. these policies can be suggested along with the conclusions; First, ostablishment of green plan-muddle and long term environmental goals Included In the urban planning to reduce enoronmental deterioration and pollution. Second, computation of sustalnability Indeu the Index Is necessary to sustainable urban development, which is related with green GNP of the national level. Third, capacity estimation of nature and social environment-estimation of enoronmental capacity to the civilized area is required become an ecopolis, and is required to focus on the western area of Pusan which has high decree of potentiality.

  • PDF

The Study on Estimation of The Transformer Capacity of Housing and Economic Evaluation Using Case Studies (공동주택 변압기용량 적정 산정을 위한 수용률 개선 및 사례 연구를 통한 경제성 평가)

  • Lee, Yun-Sang;Seo, Jung-Youl;Shin, Hee-Sang;Cho, Sung-Min;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.142-149
    • /
    • 2010
  • Interest in energy efficiency and savings have been rising internationally. For this reason, the domestic housing construction in the area of power equipment is being actively studied. Currently approximately 400,000 per year of domestic housing is being built. Applies to housing construction during the current transformer capacity low utilization and load factor has been applied has been designed. In other words, excessively high reserve capacity has been applied. According to this problem, initial facility costs and power losses will cause because transformer low utilization be appropriated. Thus, the energy efficiency drops. In this paper, analysis of past utilization of the housing transformer, and applying an appropriate demand factor has been analyzing the energy loss reduction. this analysis of current domestic conditions for the proper housing transformer scheme is to calculate the capacity.