• 제목/요약/키워드: High-brightness

검색결과 885건 처리시간 0.04초

유도결합 플라즈마를 이용한 집속이온빔용 고휘도 이온원의 개발 및 특성연구 (Development and characteristic study of high brightness ion source using inductively coupled plasma for focused ion beam)

  • Kim, Yoon-Jae;Park, Dong-Hee;Hwang, Yong-Seok
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 춘계학술대회 논문집
    • /
    • pp.494-499
    • /
    • 2004
  • A ion source using inductively coupled plasma has been tested in order to test its feasibility as a high brightness ion source for focused ion beam. When operating the ion source with filter magentas in front of plasma electrode for a negative ion source, lower remittances are expected. Extracted beam remittances are measured with an Allison-type scanning device for various plasma parameters and extraction conditions. The normalized omittance has been measured to be around 0.2$\pi$mmmrad with beam currents of up to 0.55 ㎃. In particular, noting that multicusp magnets have a role in decreasing the remittance as well as increasing plasma discharge efficiency, transverse magnetic field has been confirmed to be a useful tool fur decreasing remittance via electron energy control.

  • PDF

SMD형 Y/G/W HB LED의 광특성 비교분식 (Optic Characteristics Comparison and Analysis of SMD Type Y/G/W HB LED)

  • 황명근;허창수;서유진
    • 조명전기설비학회논문지
    • /
    • 제18권4호
    • /
    • pp.15-21
    • /
    • 2004
  • 광속구(integrating sphere photometer), 분광기(monochromator)등을 이용하여 노랑색(Y), 녹색(G), 백색(W)의 SMD(surface mounted device)형태의 HB LED(high brightness light emitting diode)에 대한 광속(luminous flux, LF), 상관 색온도(correlated color temperature, CCT), CIE 색도좌표(chromaticity coordinate CC)등 광특성을 실험하여 그 결과치를 비교 분석하였고, 백색 LED에 대해서는 연색지수를 고찰하였다.

High-brightness Phosphor-conversion White Light Source Using InGaN Blue Laser Diode

  • Ryu, Han-Youl;Kim, Dae-Hwan
    • Journal of the Optical Society of Korea
    • /
    • 제14권4호
    • /
    • pp.415-419
    • /
    • 2010
  • A phosphor-conversion white light source is demonstrated using an InGaN-based blue laser diode (LD) and a yellow-emitting phosphor excited by the blue LD. The photometric and colorimetric properties of this blue-LD-based white light source are characterized. When injection current of the LD is 100 mA, luminous flux and luminous efficiency of the white light are found to be over 5 lm and 10 lm/W, respectively. When injection current is >90 mA, luminance is estimated to be larger than 10 Mcd/$cm^2$. In addition, color characteristics of the white light such as chromaticity coordinates, a correlated color temperature, and a color rendering index are found to be quite stable as current and temperature of the LD varies. The demonstrated LD-based white light source is expected to be used in high-brightness illumination applications with good color stability.

LED 광원이 Rat의 피부 창상 치유에 미치는 영향 (The Effect of LED Light Irradiation on Skin Injury Cure of Rat)

  • 천민우;김성환;박용필;김태곤;유성미
    • 한국전기전자재료학회논문지
    • /
    • 제20권12호
    • /
    • pp.1087-1092
    • /
    • 2007
  • We developed the 4-channel Light Medical Therapy Apparatus for Skin Injury Cure using a high brightness LED. This equipment was fabricated using a micro-controller and a high brightness LED, and designed to enable us to control light irradiation time, intensity and reservation. In this paper, the designed device was used to find out how high brightness LED light affects the skin injury of SD-Rat(Sprague-Dawley Rat). In the experiment, $1\;cm^2$ wounds on the skin injury of SD-Rat(Sprague-Dawley Rat) were made. Light irradiation group and none light irradiation group divided, each group was irradiated one hour a day for 14 days. In result, compared with none light irradiation group, the lower incidence of inflammation and faster recovery was shown in light irradiation group.

Application of Naturally Antioxidant for Inhibition of Brightness Reversion of Paper Made from High Yield Bagasse Pulp

  • El-Sakhawy Mohamed;El-Ghorab Ahmed;El-Gendy Ahmed;El-Sabour Mona A.;El-Sayed Essam S. A.
    • 펄프종이기술
    • /
    • 제37권5호통권113호
    • /
    • pp.15-24
    • /
    • 2005
  • Different types of antioxidants compounds were prepared economically from natural sources. Application of these compounds towards photo stabilization of high yield bagasse pulp has been investigated. It was found that potato peel antioxidant followed by clove volatile oil provides lower brightness reversion and better photo stabilization effect for paper made from high yield bagasse pulp after exposure to UV lights in comparison with butyl hydroxy anisol or chamomile volatile oil.

고휘도 LED 전류 제어용 벅 MOSFET 구동기에 관한 연구 (A Study on Buck MOSFET Driver for High-Brightness LED Strings)

  • 김만고;정영석;안영주
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 추계학술대회 논문집
    • /
    • pp.218-220
    • /
    • 2008
  • This paper describes buck converter's MOSFET driver for high-brightness LED strings. The power driving high-side MOSFET is supplied from the power source of control circuit part. The practical considerations and future work are also described.

  • PDF

밝기를 보존하는 Multi-SMQT 기반의 콘트라스트 개선 (Multi-SMQT based Contrast Enhancement for Brightness Preservation)

  • 박강서;박래홍
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2007년도 하계종합학술대회 논문집
    • /
    • pp.373-374
    • /
    • 2007
  • This paper proposes a natural contrast enhancement algorithm that preserves the brightness of an image. In the case that an image has the partially dense distribution of intensity, conventional contrast enhancement algorithms degrade the image quality because they excessively change the intensity values. In contrast to convention algorithms, the proposed method is able to obtain a natural image with the high contrast using the concept of brightness preservation. The experimental results show the effectiveness of our algorithm.

  • PDF

앱 영상 분류를 이용한 모바일 디바이스의 시인성 향상 (Enhancement of Visibility Using App Image Categorization in Mobile Device)

  • 김대철;강동욱;김경모;하영호
    • 전자공학회논문지
    • /
    • 제51권8호
    • /
    • pp.77-86
    • /
    • 2014
  • 모바일 디바이스는 일반적으로 인위적인 디자인의 앱 영상으로 구성된다, 따라서, 본 논문에서는 주변 밝기에 따라 앱 영상별 최적의 밝기를 설정하여 재현함으로 모바일 디스플레이에서의 최적의 시인성을 나타내는 방법을 제안한다. 먼저 두 가지의 사전실험을 통하여 시인성에 영향을 주는 앱 영상의 특성요소를 찾고, 각 앱 영상별 만족하는 디바이스 밝기를 조사하였다. 다음으로, 앱 영상별로 이들 요소들과 디바이스 만족 밝기와의 관계를 비교 분석하였다. 그 결과, 평균 밝기와 진출색의 분포비율을 이용하여 앱 영상을 분류하고 각 분류별 가장 많은 빈도를 나타내는 만족 밝기를 최적 밝기로 설정하였다. 평가를 위한 실험에서 분류된 영상별 최적의 밝기에 대해 시인성 테스트를 수행한 결과 분류된 앱 영상에 따라 다양한 조도 환경에 대하여 높은 만족도를 나타냄을 확인하였다.

KOMPSAT-2 영상과 IKONOS/GEOEYE-1 영상의 밝기값 상호비교 (Brightness Value Comparison Between KOMPSAT-2 Images with IKONOS/GEOEYE-1 Images)

  • 김혜연;김태정;이혁
    • 대한원격탐사학회지
    • /
    • 제28권2호
    • /
    • pp.181-189
    • /
    • 2012
  • 최근 수질추정을 위한 고해상도 위성영상의 활용 가능성에 대한 관심이 증대되고 있다. 그러나 고해상도 위성영상에서의 수면지역의 낮은 SNR(Signal to Noise Ratio)과 밝기값 비선형성과 같은 방사학적 오차는 수질추정 정확도를 감소시키는 원인이 된다. 이에 따라 위성영상을 이용한 정확한 수질추정을 위해서는 방사학적 보정이 반드시 수행되어져야 하나 KOMPSAT-2 위성영상의 경우 밝기값과 입사광량간 변환관계식이 제공되지 않기 때문에 이러한 방사학적 보정에 어려움이 존재한다. 따라서 수질모니터링에 KOMPSAT-2 영상을 활용하기 위해서는 밝기값 비선형성과 내륙 수면지역의 잡음현상을 실험적으로 파악할 필요가 있다. 본 논문에서는 충분한 검보정을 통해 선형성이 보장되고 있는 IKONOS와 GeoEye-1 영상을 기준영상으로 사용하여 동일시기에 동일지역을 촬영한 KOMPSAT-2 영상과의 밝기값 상호비교를 수행하였다. 상호비교 결과, 기준영상에 비해 KOMPSAT-2 영상의 잡음은 다소 높게 나타나나 밝기값의 경향 및 잡음의 크고 작은 패턴은 정확하게 일치하였고 KOMPSAT-2 영상 내 잡음의 영향이 최소화되는 적절한 영역의 크기는 $5{\times}5$로 나타났다. 또한 모든 실험 영상에서 밝기값의 비선형성은 존재하지 않는 것으로 확인되었다. 실험결과는 KOMPSAT-2 영상이 클로로필 농도와 같은 수질인자 추정을 위해 사용될 수 있는 가능성을 보여준다.

Introduction to Simulation Activity for CMDPS Evaluation Using Radiative Transfer Model

  • Shin, In-Chul;Chung, Chu-Yong;Ahn, Myoung-Hwan;Ou, Mi-Lim
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.282-285
    • /
    • 2007
  • Satellite observed brightness temperature simulation using a radiative transfer model (here after, RTM) is useful for various fields, for example sensor design and channel selection by using theoretically calculated radiance data, development of satellite data processing algorithm and algorithm parameter determination before launch. This study is focused on elaborating the simulation procedure, and analyzing of difference between observed and modelled clear sky brightness temperatures. For the CMDPS (COMS Meteorological Data Processing System) development, the simulated clear sky brightness temperatures are used to determine whether the corresponding pixels are cloud-contaminated in cloud mask algorithm as a reference data. Also it provides important information for calibrating satellite observed radiances. Meanwhile, simulated brightness temperatures of COMS channels plan to be used for assessing the CMDPS performance test. For these applications, the RTM requires fast calculation and high accuracy. The simulated clear sky brightness temperatures are compared with those of MTSAT-1R observation to assess the model performance and the quality of the observation. The results show that there is good agreement in the ocean mostly, while in the land disagreement is partially found due to surface characteristics such as land surface temperature, surface vegetation, terrain effect, and so on.

  • PDF