• 제목/요약/키워드: High-Voltage Direct Current(HVDC)

검색결과 138건 처리시간 0.024초

중첩전압(직류+교류 60Hz)에서 산화아연 피뢰기 소자의 누설전류 특성 (The characteristic of leakage current in ZnO surge arrestor elements with mixed direct and 60Hz voltage)

  • 이복희;박건영;강성만;최휘성;오성균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.186-188
    • /
    • 2003
  • The ZnO surge arrester is the protective device for limiting surge voltages on equipment by diverting surge current and returning the device to its original status. The occurrence of overvoltage appears in any phase to AC power supply system and it appears in mixing AC and impulse voltages, moreover because HVDC power supply system uses converter in semiconductor, it makes mixed DC and high harmonics voltages. In this study, the various mixed AC and DC voltages was made for investigating the degradation effect of ZnO arrester according to mixed voltage. As a result, the increase of DC component to mixed voltages causes the increase of resistive component of total leakage current to ZnO block. In changing V-I curve for mixed voltages, the cross-over point acts a factor as making the proper capacitor size of an equivalent circuit for ZnO block.

  • PDF

풍력발전기를 포함하는 전력계통에서의 신뢰도 기반 HVDC 확충계획 (Probabilistic Reliability Based HVDC Expansion Planning of Power System Including Wind Turbine Generators)

  • 오웅진;이연찬;최재석;윤용범;김찬기;임진택
    • 전기학회논문지
    • /
    • 제67권1호
    • /
    • pp.8-15
    • /
    • 2018
  • New methodology for probabilistic reliability based grid expansion planning of HVDC in power system including Wind Turbine Generators(WTG) is developed in this paper. This problem is focused on scenario based optimal selection technique to decide best connection bus of new transmission lines of HVDC in view point of adequacy reliability in power system including WTG. This requires two kinds of modeling and simulation for reliability evaluation. One is how is reliability evaluation model and simulation of WTG. Another is to develop a failure model of HVDC. First, reliability evaluation of power system including WTG needs multi-state simulation methodology because of intermittent characteristics of wind speed and nonlinear generation curve of WTG. Reliability methodology of power system including WTG has already been developed with considering multi-state simulation over the years in the world. The multi-state model already developed by authors is used for WTG reliability simulation in this study. Second, the power system including HVDC includes AC/DC converter and DC/AC inverter substation. The substation is composed of a lot of thyristor devices, in which devices have possibility of failure occurrence in potential. Failure model of AC/DC converter and DC/AC inverter substation in order to simulate HVDC reliability is newly proposed in this paper. Furthermore, this problem should be formulated in hierarchical level II(HLII) reliability evaluation because of best bus choice problem for connecting new HVDC and transmission lines consideration. HLII reliability simulation technique is not simple but difficult and complex. CmRel program, which is adequacy reliability evaluation program developed by authors, is extended and developed for this study. Using proposed method, new HVDC connected bus point is able to be decided at best reliability level successfully. Methodology proposed in this paper is applied to small sized model power system.

HVDC 연계 시스템의 전력계통 안정화 장치와 전력변환기의 적정 파라메터 선정에 관한 연구 (A Study on the Appropriate Selection of a Power System Stabilizer and Power Converters for HVDC Linked System)

  • 김경철;문병희
    • 조명전기설비학회논문지
    • /
    • 제16권2호
    • /
    • pp.45-53
    • /
    • 2002
  • 본 논문은 두 지역 간에 직렬로 연결된 HVDC 연계시스템의 전력계통 안정화장치와 전력변환기의 적정 파라메터 선정기법을 다루었다. PSS파라메터 선정기법은 구하고자 하는 진상이 되도록 극좌표를 이동시키고, 충분한 댐핑을 얻도록 이득을 조절하는 고전적인 기법이다. 전력변환기의 적정 파라메터는 근궤적기법을 근거로 하여 기준 값의 변화와 시스템의 동요에 충분한 속응력과 안정도를 고려하여 산정한다. 이들 기법으로 구판 제정수로 소신호 및 과도안정도 분석결과는 사례연구시스템의 고유동요 주파수에 적절한 댐핑 효과를 보여주었다. 본 논문에서 사용한 프로그램은 MATLAB을 근거로 한 PST이다.

MgO를 첨가한 에폭시 나노 컴퍼지트의 절연파괴강도 온도의존성 (Temperature Dependence on dielectric breakdown strength of Epoxy Nano-Composites depending on MgO)

  • 정인범;한현석;이영상;조경순;신종열;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.48-48
    • /
    • 2010
  • In this paper, we have investigated temperature dependence of dielectric breakdown voltage at epoxy with added nano-filler(MgO), which is used as a filler of epoxy additives for HVDC(high voltage direct current) submarine cable insulating material with high thermal conductivity and restraining tree to improve electrical properties of epoxy resin in high temperature region. In order to find dispersion of the specimen, the cross sectional area of nano-composite material is observed by using the SEM(Scanning Electron Microscope) and it is conformed that each specimen is evenly distributed without the cohesion. As a result, it is confirmed that the strength of breakdown of all specimen at 50 [$^{\circ}C$] decreased more than that of the dielectric breakdown strength at room temperature. When temperature increases from 50 [$^{\circ}C$] to 100 [$^{\circ}C$], we have confirmed that breakdown strength of virgin specimen decreases, but specimens with added MgO show constant dielectric breakdown strength.

  • PDF

설비신뢰성 향상을 위한 무수은형 카드릴레이 개발 및 운영 (The Development of No-Mercury Type Card Relay for Improving the Reliability of Electrical Facilities)

  • 안준기;장재원;김정권;양재원;이세일
    • 전기학회논문지
    • /
    • 제56권4호
    • /
    • pp.641-644
    • /
    • 2007
  • The electro-mechanical mercury relay is used as an auxiliary relay of power facility because it is superior to operating time and no-bounce. So the KEPCO had used the mercury relay for operating HVDC(High Voltage Direct Current) system. But it has many problems with facility operation by occurrence of mercury evaporation, held contact point and malfunction according to long term use, furthermore it is forbidden to produce for fear of environmental pollution in 2002. This paper presents the no-mercury relay development, comparison test and application.

해상 풍력 연계 MMC 제어 알고리즘 개발을 위한 OPLA-RT 기반의 HILS 구축 (Implementation of OPLA-RT based HILS system for developing MMC control algorithm of offshore wind power)

  • 신동철;윤진우;이동명
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.414-415
    • /
    • 2019
  • 본 논문은 HVDC(High Voltage Direct Current)에 적용된 MMC(Modular Multilevel Converter)의 제어 알고리즘 개발을 위한 HILS(Hardware In the Loop Simulation)을 위한 모델링 및 HILS 시스템 구축 예를 보인다. 전력 계통, MMC, 풍력 발전 등의 HILS 적용 MATLAB/SIMULINK 모델 및 FPGA(Field Programmable Gate Array)를 이용한 제어기 개발 내용을 보인다. 시뮬레이션 모델과 FPGA 제어기를 이용하여 구축한 OPAL-RT 기반의 실험 결과를 보인다.

  • PDF

나노 충진제에 따른 에폭시 나노 컴퍼지트의 절연파괴강도 특성 (Dielectric Breakdown Characteristics Depending on The Nano Filler of Epoxy Nano-composites)

  • 박태학;백승학;이동건;박홍규;정인범;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.92-92
    • /
    • 2010
  • In this paper, the test is performed on MgO, which is used as a filler in epoxy additives, respectively (0, 1.0, 3.0, 5.0, 7.0, 10 [wt%]) for HVDC(high voltage direct current) submarine cable insulating material to improve electrical properties of epoxy resin in high temperature. The breakdown strength due to increasing amount of filler increased to 5.0 [wt%] by the effects of the Coulomb blockade. However, it is confirmed that strength of dielectric breakdown decreased because the filler functioned as impurities and affected the breakdown when filler additive exceeded by 5.0 [wt%] or more. We have found that the highest dielectric breakdown strength of specimen added 5.0 wt% at $25^{\circ}C$, and is more increased approximately 13.7 [%] than virgin specimen.

  • PDF

2선식 수동루프를 이용한 345[kV] 송전선 주변의 자계저감 설계기법 연구 (A Study on Magnetic Field Reduction Design Technique around 345 kV Transmission Line with 2-wire Set Passive Loop)

  • 김응식
    • 한국안전학회지
    • /
    • 제36권5호
    • /
    • pp.10-17
    • /
    • 2021
  • The controversy over the risk of the human body being affected by electromagnetic fields emitted from 60 Hz power lines continues without end. There are currently no new studies or research progress being made in this direction that is notable, and the number of civil complaints is gradually increasing. The problem is that each study produces different results, among which the effect of exposure to magnetic fields on childhood leukemia is a major one. In Korea, an electrician who was maintaining a 22.9 kV power line died of leukemia, which has recently been recognized as an occupational disease. Methods to reduce magnetic fields from power lines include shielding with wire loops, incorporating split phases and compaction techniques, installing underground power lines, converting to high-voltage direct current (HVDC), and increasing the ground clearance of transmission towers. Depending on whether a separate power supply is needed or not, there are two types of wire loops: passive loop and active loop. Magnetic field reduction is currently done through underground power lines; however, the disadvantage of this process is high construction costs. Installing passive loops, with relatively low construction costs, leads to lower magnetic field reduction rates than installing underground cables and a weakness to not solving the landscape problem. This methodological study aims at designing methods and reducing the effects of 2-wire set loops-the simplest and most practical. Since the method proposed in this study has been designed after analyzing the distribution of complex electromagnetic fields near the expected loop installation location, a practical design can be implemented without the need for any difficult optimization programming.