• Title/Summary/Keyword: High-Temperature components

검색결과 1,257건 처리시간 0.029초

적출 심근의 칼륨경축에 대한 칼슘이온 효과 (Effect of $Ca^{++}$ on High K-induced Contracture of Isolated Frog Ventricular Muscle)

  • 최윤백;김기환
    • The Korean Journal of Physiology
    • /
    • 제20권1호
    • /
    • pp.31-41
    • /
    • 1986
  • The sufficient myoplasmic $Ca^{++}$ to react with the contractile proteins is necessary to induce contraction of a cardiac muscle. These $Ca^{++}$ for the production of muscle contraction are supplied from the three recognized $Ca^{++}$ sources; internal $Ca^{++}$ release via the sarcoplasmic reticulum(SR), $Ca^{++}$ influx through a gated Ca-channel in the membrane as a Isi, and $Ca^{++}$ transport by the mechanism of Na/ca exchange. However, it is still controversial which $Ca^{++}$ sources act as a main contributor for myoplasmic $Ca^{++}$, Therefore, this study was undertaken in order to examine the $Ca^{++}$ sources for the contraction of frog ventricle. There is evidence that the SR is sparse in frog ventricular fibers, and that T-tubules are absent. Isolated ventricular strips of frog, Rana nigromaculata, were used in this experiment. Isometric tension was recorded by force transducer, and membrane potentials of ventricular muscles were measured through the intracellular glass microelectrodes, which were filled with 3M KCI and had resistance of $30{\pm}50M{\Omega}$. All experiments were performed at room temperature in a tris·buffered Ringer solution which was aerated with 100% $O_2$. Isotonic high K, low Na solution was used to induce K-contracture, K-contracture appeared at the concentration of 20 to 30mM-KCI and was potentiated in parallel with the increase in KCI concentration. The contracture had two components: an initial rapid phasic and a subsequent slow tonic contractile responses. Membrane Potentials measured at normal Ringer solution(2.5mM KCI) was -90 to -100 mV, and decreased linearly as the KCI concentration increased; -55mV at 20mM.KCI, -45mV at 30 mM.KCI, -30 mY at 50 mM.KCI, and -12 mV at 100 mM.KCI. K-contracture was evoked firstly at the membrane potential of -45 mV. The contracture was potentiated by the increase of bathing extracellular $Ca^{++}$ concentration. However, in the absence of $Ca^{++}$ the contracture was almost not induced by 50 mM.KCI solution. Caffeine(20mM) in normal Ringer solution, which is known to release $Ca^{++}$ from SR without substantial effects on the $Ca^{++}$ fluxes across the surface membrane, did not affect membrane potential and also not initiate contracture, but the caffeine in 20 mM-KCI Ringer solution produced a contracture. Above results suggest that the main $Ca^{++}$ source for the K·contracture of frog ventricle is $Ca^{++}$ influx through the voltage-dependent Ca-channel, and that in the K-contracture at the concentration of 100 mM-KCI, the mechanism of Na/ca exchange also partly contributs, in addition to the $Ca^{++}$ influx.

  • PDF

국내 재배 엽맥섬유의 특성에 관한 연구 (Characteristics of the Leaf Fiber Plants Cultivated in Korea)

  • 이혜자;김남은;유혜자;한영숙
    • 한국의류학회지
    • /
    • 제33권5호
    • /
    • pp.711-720
    • /
    • 2009
  • Leaf fibers have many good properties; they are strong, long, cheap, abundant and bio-degradable. Since they, however, contain a great quantity of non-cellulose components, they have been used for the materials of mats, ropes, bags and nets rather than those of clothing. In this study, we investigated the characteristics of leaf fibers in order to promote the use of leaf fibers for the materials of clothing as well as develop the high value-added textile fibers. Leaf fiber plants including New Zealand Flax, Henequen and Banana plant, which have various nature and shape, were used. New Zealand Flax and Henequen leaves were cut from lower part of plants. Banana leaves and pseudo-stems were peeled and cut from the stem of Banana plants. First, the thin outer skins like film of leaves, veins and stems were removed before retting. The chemical retting had been processed for 1hour, at 100 in 0.4% $H_2SO_4$ aqueous solution(liquid ratio 50:1). Then, the retted leaf fibers had been soaked for 1hour, at room temperature in 0.5% NaClO solution(v/v) to remove the miscellaneous materials. We investigated the physical characteristics of three leaf fibers including the transversal and longitudinal morphology, the contents(%) of pectin, lignin and hemicellulose, the length and diameter of fibers, the tensile strength of the fiber bundles, and the fiber crystallinity and the moisture regain(%). The lengths of fiber from three leaf fibers were similar to their leaf lengths. The fiber bundles were composed of the cellulose paralleled to the fiber axis and the non-cellulose intersecting at right angle with the fiber axis. The diameters of New Zealand Flax, Henequen and Banana fibers were $25.13{\mu}m$, $18.16{\mu}m$ and $14.01{\mu}m$, respectively and their tensile strengths were 19.40 Mpa, 32.16 Mpa and 8.45 Mpa, respective. The non-cellulose contents of three leaf fibers were relatively as high as 40%. If the non-cellulose contents of leaf fibers might be controlled, leaf fibers could be used for the materials of textile fiber, non-wovens and Korean traditional paper, Hanjee.

결빙 증식 최소화를 위한 다중 익형 형상 최적설계 (Design Optimization of Multi-element Airfoil Shapes to Minimize Ice Accretion)

  • 강민제;이혁진;조현승;명노신;이학진
    • 한국항공우주학회지
    • /
    • 제50권7호
    • /
    • pp.445-454
    • /
    • 2022
  • 항공기가 빙점 이하의 습도가 높은 구름대를 지날 때 액적이 항공기와 충돌하면 날개, 동체 등 항공기 구성품에 결빙이 발생한다. 특히 항공기의 날개에 결빙이 증식되면 공력 성능의 저하와 비행 안정성의 감소 등의 치명적인 안전 문제를 초래할 수 있다. 본 연구에서는 항공기 날개에 적용되는 고양력 장치인 다중 익형의 결빙 증식량이 최소가 되도록 형상 최적설계를 수행하였다. 3차원 Reynolds-Averaged Navier-Stokes 지배 방정식을 이용하여 공력해석을 수행하였고, 다물리 전산해석을 통해 결빙의 형상 및 증식량을 예측하였다. 최적설계의 목적함수는 결빙 증식량 최소화로 설정하였고, 설계변수는 Slat과 Flap의 전개 각도와 위치를 정의하는 형상 변수 6개를 선정하였다. 설계 과정에서 목적함수의 평가는 크리깅 근사모델을 사용하여 대체하였고 유전자 알고리즘을 적용하여 최적 형상을 도출하였다. 최적화를 수행한 결과, Slat과 Flap에 최적의 전개 각도와 위치를 적용하였을 때 결빙 증식량이 약 8% 감소하였다.

Hansen Solubility Parameter 를 통한 W/O 형 자외선차단 제형의 유화 안정성에 관한 연구 (A Study on the Emulsifying Stability of W/O Type Sunscreen Cream by the Hansen Solubility Parameter)

  • 김동희;이진재
    • 대한화장품학회지
    • /
    • 제47권4호
    • /
    • pp.273-280
    • /
    • 2021
  • 자외선차단 제형은 내수성이 중요하므로 수상이 유상에 분산되는 water-in-oil (W/O) 에멀젼으로 만드는 것이 바람직하다. 이 경우에는 오일 특유의 무겁고 끈적이는 사용감 때문에 이를 보완하는 방법으로 실리콘계 오일을 사용한다. 이러한 오일은 유기 자외선차단제와의 상용성이 낮아 에멀젼의 안정성에 문제가 되고 있다. 본 연구에서는 자외선차단 제형의 W/O 에멀젼에서 다양한 오일들 간의 상용성을 Hansen solubility parameter(HSP)를 이용하여 수치적으로 도출하였다. HSP는 물질의 분산, 극성 및 수소 결합을 나타내는 지표로 물질간의 상용성을 판단하는데 유용하다. 본 연구에서는 HSP가 다른 다양한 오일을 선정하여 W/O 에멀젼을 제조하고 제형의 시간에 따른 점도 변화 및 안정성을 조사하여 HSP 수치와의 상관관계 또는 일치성을 고찰하였다. HSP를 이용하면 상용성이 높은 오일 선택을 용이하게 할 수 있었다. 또한, W/O 에멀젼에서 유상의 상용성이 높으면 점도의 경시변화가 작았으며 freeze-thaw cycle (-15 ℃ ~ 45 ℃) 조건에서 안정성이 향상된 것을 확인하였다. 향후 HSP를 통해 성분 구성을 최적화한다면 사용감이 우수하면서 안정성을 확보한 W/O형 자외선차단 제형 개발에 도움이 될 것이라 기대된다.

경상지역 제철유적의 산지추정 연구: 암석기재학 및 지화학적 접근 (A Provenance Study of Iron Archaeological Sites in the Gyeongsang Province: Petrographic and Geochemical Approaches)

  • 조재국;김서진; 한지선;김수경;신동복;곽병문;홍주현;유병용;임진아
    • 자원환경지질
    • /
    • 제56권4호
    • /
    • pp.475-499
    • /
    • 2023
  • 경상지역 제철유적의 원료산지 추정을 위해 제철시료와 주요 철광상 철광석을 대상으로 암석기재학 및 지화학적 특성을 비교 분석하였다. 각 지역에서 발굴된 제철유적 시료는 제련공정 단계에 따라 원료철광석, 괴련철, 괴련철슬래그, 선철, 선철슬래그, 단조박편, 단야철, 철정 및 화살촉으로 분류되었고 각각 상이한 구성광물과 조직을 보였다. 또한 슬래그를 구성하는 규산염광물에서의 알루미늄 및 칼슘 등의 주원소 성분의 농집과 제철유물에서 니켈 및 구리 등의 미량원소 함량이 높은 것은 원료철광석의 특성이 반영된 것으로 잠재적인 제철원료의 산지추정인자로 여겨진다. 특히 제철유적 시료의 납-스트론튬 동위원소비는 크게 1) 원료철광석과 유사한 조성을 보이는 경우, 2) 스트론튬 동위원소비가 부화된 경우, 그리고 3) 납-스트론튬 동위원소비 모두 부화된 경우로 구별되며 이러한 동위원소비 특성은 고온의 제련공정 과정에서 첨가된 특정 조재제와의 혼염 가능성을 시사한다. 이러한 결과는 첨가물이 제련과정에 미치는 잠재적인 기여 측면에서 경상지역 제철유적의 산지추정 해석에 새로운 시각을 제시한다.

전기영동증착법으로 폴리이미드를 코팅한 탄소섬유의 발열 특성 연구 (Heating Characteristics of Carbon Fiber Polyimide-Coated by Electrophoretic Deposition)

  • 정건주;김태유;정승부;김광석
    • 마이크로전자및패키징학회지
    • /
    • 제30권1호
    • /
    • pp.90-94
    • /
    • 2023
  • 금속 발열체는 높은 열손실과 화재 위험성 등의 문제점이 있어 우수한 열전도도와 전기전도도 특성을 갖는 탄소섬유가 대체소재로 각광받고 있다. 그러나 탄소섬유는 약 200℃ 이상에서 산화하여 단선되기 때문에 발열체 적용이 제한적이며, 현재 진공관 형태로 탄소섬유 발열체가 일부 사용되고 있다. 본 연구에서는 진공관을 사용하지 않고 대기 중탄소섬유 산화방지를 위해 전기영동증착법으로 탄소섬유 표면에 내열성이 높은 폴리이미드를 코팅하였으며 인가전압에 따른 코팅 두께와 내열성을 확인하였다. 폴리이미드를 코팅한 탄소섬유 발열체를 직렬 연결하여 만든 히터는 최대 292℃ 까지 안정적인 발열 특성을 보였으며 이는 열전달 시뮬레이션의 발열온도 결과와 유사하였다. 전기영동증착방법으로 코팅한 폴리이미드 층은 200℃ 이상에서 탄소섬유의 산화방지에 효과적이며 발열 안정성을 요구하는 2차전지, 우주항공, 전기자동차 등 다양한 발열 부품에 적용 가능할 것으로 기대된다.

Improvement of lower hybrid current drive systems for high-power and long-pulse operation on EAST

  • M. Wang;L. Liu;L.M. Zhao;M.H. Li ;W.D. Ma;H.C. Hu ;Z.G. Wu;J.Q. Feng ;Y. Yang ;L. Zhu ;M. Chen ;T.A. Zhou;H. Jia;J. Zhang ;L. Cao ;L. Zhang ;R.R. Liang;B.J. Ding ;X.J. Zhang ;J.F. Shan;F.K. Liu ;A. Ekedahl ;M. Goniche ;J. Hillairet;L. Delpech
    • Nuclear Engineering and Technology
    • /
    • 제54권11호
    • /
    • pp.4102-4110
    • /
    • 2022
  • Aiming at high-power and long-pulse operation up to 1000 s, some improvements have been made for both 2.45 GHz and 4.6 GHz lower hybrid (LH) systems during the recent 5 years. At first, the guard limiters of the LH antennas with graphite tiles were upgraded to tungsten, the most promising material for plasma facing components in nuclear fusion devices. These new guard limiters can operate at a peak power density of 12.9 MW/m2. Strong hot spots were usually observed on the old graphite limiters when 4.6 GHz system operated with power >2.0 MW [B. N. Wan et al., Nucl. Fusion 57 (2017) 102019], leading to a reduction of the maximum power capability. With the new limiters, 4.6 GHz LH system, the main current drive (CD) and electron heating tool for EAST, can be operated with power >2.5 MW routinely. Long-pulse operation up to 100 s with 4.6 GHz LH power of 2.4 MW was achieved in 2021 and the maximal temperature on the guard limiters measured by an infrared (IR) camera was about 540 ℃, much below the permissible value of tungsten material (~1200 ℃). A discharge with a duration of 1056 s was achieved and the 4.6 GHz LH energy injected into the plasma was up to 1.05 GJ. Secondly, the fully-active-multijunction (FAM) launcher of 2.45 GHz system was upgraded to a passive-active-multijunction (PAM), for which the density of optimum coupling was relatively low (below the cut-off value). Good coupling with reflection coefficient ~3% has been achieved with plasma-antenna distance up to 11 cm for the new PAM. Finally, in order to eliminate the effect of ion cyclotron range of frequencies (ICRF) wave on 4.6 GHz LH wave coupling, the location of the ICRF launcher was changed to a port that is located 157.5° toroidally from the 4.6 GHz LH system and is not magnetically connected.

플래시광 열처리를 통한 압전 고분자의 결정성 향상 연구 (Enhanced Crystallinity of Piezoelectric Polymer via Flash Lamp Annealing)

  • 이동훈;정성민;장학수;하동주;현동열;우유미;백창연;이민구;이경자;박정환;박귀일
    • 한국전기전자재료학회논문지
    • /
    • 제37권4호
    • /
    • pp.427-432
    • /
    • 2024
  • The polymer crystallization process, promoting the formation of ferroelectric β-phase, is essential for developing polyvinylidene fluoride (PVDF)-based high-performance piezoelectric energy harvesters. However, traditional high-temperature annealing is unsuitable for the manufacture of flexible piezoelectric devices due to the thermal damage to plastic components that occurs during the long processing times. In this study, we investigated the feasibility of introducing a flash lamp annealing that can rapidly induce the β-phase in the PVDF layer while avoiding device damage through selective heating. The flash light-irradiated PVDF films achieved a maximum β-phase content of 76.52% under an applied voltage of 300 V and an on-time of 1.5 ms, a higher fraction than that obtained through thermal annealing. The PVDF-based piezoelectric energy harvester with the optimized irradiation condition generates a stable output voltage of 0.23 V and a current of 102 nA under repeated bendings. These results demonstrate that flash lamp annealing can be an effective process for realizing the mass production of PVDF-based flexible electronics.

수도원연품종간잡종에 있어서의 생육일수와 불임에 관한 연구 (Studies on the growth duration and hybrid sterility in remote cross breeding of cultivated rice)

  • 허문회
    • 한국작물학회지
    • /
    • 제4권1호
    • /
    • pp.31-71
    • /
    • 1968
  • 수도원연품종간 교배육종에 있어서 지리적 생태품종 간의 잡종 초기 세대의 생육일수와 불임성의 변이에 관한 지견을 얻고자 대표적인 Indica와 Japonica 그리고 그중간형인 Beaumont 품종과 Ponlai등 7개 품종을 상호 교배하여 IRRI(북위 $14^{\circ}$17')에서 $F_1$ 을 10시간 및 14시간 조명하에서 $F_2$를 단일건계의 자연일장하에서 재배하고 수원(북위 $37^{\circ}$16')에서도 $F_1$을 10시간 및 자연일장하에, $F_2$$F_3$을 자연일장하에 각각 재배하고 출수일수 및 불임율을 조사 연구하였다. 1. 출수일수 : 1) $F_1$들은 10시간 단일하에서는 조생이 만생에 대해 우성 내지 초월성으로 나타났고 14시간 장일하에서는 우성 내지 불완전 우성으로 나타났는데 IRRI와 수원에서 모두 같았다. 2) IRRI에서 단일시기에 재배된 $F_2$는 조생이 만생에 대해 불완전우성이며 분리는 연속적이었다. 수원에서 조기재배된 $F_2$는 대부분의 조합에서 조생이 불완전우성이거나 중간성으로 적기 재배된 $F_2$는 대부분의 조합에서 만생이 불완전 우성이거나 중간성으로 나타났다. 3) 극단의 만생간의 조합에 있어서도 유효 출수 가능한 초월분리 개체가 있었다. 4) 기본영양생장성이 긴 품종들의 조합에서는 변이의 폭이 넓었고 신품종의 평균과 친계열평균 변이계수와에는 높은 상관이 있었다. 5) $F_1$이나 중간친으로 $F_2$집단의 평균 출수일수를 예측할수 있으며 $F_2$평균과 $F_3$계통 평균과에도 높은 상관이 있었으나 IRRI에서 재배된 $F_2$개체와 수원에서 재배된 $F_3$계통간의 상관은 없었다. 6) IRRI에서 재배된 $F_2$와 수원에서 재배된 $F_3$계통간에는 통계학적으로 조정된 heritability가 매우 낮아서 출수일수에 관한 선발의 효과는 단일감응성 품종에 대해서는 기대하기 어렵다. 7) $F_1$$F_2$의 평균 출수일수는 정역교배간에 차가 없거나 극소하였다. 8) 잡종의 단일감응성 측정치를 친계열별 평균과 이 평균으로 부터의 편차로 구분 계산하여 단일감응성에 기여하는 양친들의 효과에 따라 친품종을 감응성품종과 비감응성 품종을 구분 할 수 있었다. 9) 단일감응성은 $F_1$이 양친보다 높으며 $F_2$, $F_3$으로 세대가 진전함에 따라 낮아진다. 10) 온도차에 따른 $F_1$의 출수일수 반응은 양친품종보다 작으며 장일과 단일하에서의 온도반응의 차이는 품종에 따라 차이가 있었다. 2. 불임율 : 1) IRRI에서도 수원에서도 다같이 $F_1$의 불임은 조합에 따라 차가 크며 친품종의 불임율과 상관이 없었다. 또 10시간 단일하에서는 14시간 장일하에서 보다 불임율이 높았다. 2) $F_1$에서 불임이 높았던 조합이 $F_2$에서도 높았으며 단일감응성이 높은 품종과 고온감응성이 높은 품종간의 조합에서 불임이 높았고 그 분산의 폭도 넓었다. 3) $F_2$ 평균은 $F_1$보다 낮으며 $F_3$계통들의 평균은 $F_2$평균보다 낮아 세대가 진전됨에 따라 불임율이 낮아지며 $F_3$에서는 조합간의 차가 현저하지 못하게 되었다. 4) $F_2$에 있어서는 화분불임과 종실불임간에 상관이 미약하였다. 5) $F_1$$F_2$평균의 불임율에는 정역교배간에 차가 없었다. 6) 잡종 불임을 잡종강세에서와 같이 Griffing의 방법에 따라 조합 능력 검정을 한 결과 SCA 효과는 GCA효과보다 컸는데 SCA효과가 특히 큰 것은 감광성이 높은 품종과 감온성이 높은 품종간의 조합들이였다. 7) IRRI에서 재배된 $F_2$와 수원에서 재배된 $F_3$과에는 불임에 관해 상관이 낮으며 $F_3$에서는 $F_2$에서보다 불임율이 낮아졌다. 8) $F_2$에 있어서 출수일수와 불임율과에는 상관이 거의 없었다.

  • PDF

시뮬레이션 모형에 의한 온실의 열환경 분석 (Analysis of Greenhouse Thermal Environment by Model Simulation)

  • 서원명;윤용철
    • 생물환경조절학회지
    • /
    • 제5권2호
    • /
    • pp.215-235
    • /
    • 1996
  • 본 연구에서 수행한 Model 시뮬레이션에 의한 열환경 분석 기법은 지역별로 다양한 기상여건 하에서 대상온실의 난방 및 냉방부하를 보다 합리적으로 예측할 수 있을 뿐만 아니라 냉방이나 난방용 시스템의 결정을 비롯한 난방대책을 수립하고, 에너지 이용 전략의 수립이나 계절적인 작부계획 수립, 온실산업용 적지선정 등에 유익하게 활용될 수 있을 것이라 판단된다. 본 연구에서는 온실의 적극적인 환경조절 유형을 난방과 냉방의 두 가지로 대별하고, 난방 소요열량 산정을 비롯하여 야간의 보온 커튼효과, Heating Degree-Hour 산정 등 난방과 관련된 시뮬레이션은 동적 모형을 이용하여 시간별, 일별 및 월별로 검토하였으며, 환기를 비롯한 차광, 증발냉각시스템의 효과 분석은 정적모형을 이용하여 검토하였다. 특히 하절기 지하수와 같은 저온수를 직접 이용하거나 Heat Pump를 통하여 확보될 수 있는 저온수를 이용하여 온실의 피복면에 살수함으로서 확보할 수 있는 온실냉방효과를 검토하는 데는 1.2m$\times$2.4m 크기의 모형온실을 제작하여 기초실험을 수행함으로서 동절기의 수막시스템의 보온효과와 마찬가지로 하절기 냉방 효과를 거둘 수 있다는 가능성을 확인하였다. 본 연구에 활용된 온실의 수치 환경모형 중 난방관련 시뮬레이션용 동적 수치모형은 소기의 목적을 달성하는데 충분히 응용될 수 있는 이론모형이다. 이 이론모형이 범용성이 높은 것은 온실 내ㆍ외의 미기상 변화, 특히 난방이나 냉방이 본격적으로 요구되는 기간동안에 온도, 습도, 일사, 풍속 등의 미기상 인자들을 면밀하게 관찰하여 실측된 자료를 바탕으로 개발되었고, 다양한 자료에 의해 충분히 검정되었기 때문이다. 본 연구에서는 경남 진주지역의 어느 특정 기간(1987년)의 시간별 기상자료를 중심으로 온실의 열적 환경변화에 대한 수치모형 시뮬레이션을 실시하였으며, 아직 수치모형에 의한 시뮬레이션이 불가능한 일부 냉방효과를 검토하는 데는 모형 실험을 실시하였으며, 그 결과를 요약하면 다음과 같다. 1. 주간과 야간의 설정온도를 달리하고 다단계 변온조절방식으로 시뮬레이션을 행한 결과 난방 소요열량은 난방 설정온도에 따라 현저한 차이를 보였다. 특히 주간 설정온도에 비하여 야간 설정온도가 난방 소요열량에 예민하게 영향을 미치므로 야간의 설정온도 결정에 신중을 기해야 할 것으로 판단된다. 2. 기존의 Heating Degree-Hour 자료는 평균 외기온을 중심으로 임의의 설정온도에 대하여 산정된 값이므로 난방 소요열량에 대한 상대적인 비교수단은 되나 고려되는 기상인자의 제한과 설정온도의 임의성 때문에 실용성이 부족하다. 따라서 본 연구에서 제시된 것처럼 온실 주변의 제반 미기상 인자나 경계조건이 반영됨은 물론 작물의 생육상태 및 구체적인 설정온도까지도 고려하는 동적 수치모형으로 시시각각으로 예측된 실내기온을 중심으로 재배기간 동안의 난방열량을 적산함이 합리적이라 판단된다. 기존의 MDH 자료로 난방 설계를 할 경우에는 지나치게 과잉설계 될 가능성이 있다. 3. 산정된 난방 소요열량은 물론 커튼의 보온성능도 월별 기상여건에 따라 현저한 차이를 보이며, 시뮬레이션에 이용된 커튼의 경우 높은 보온효과를 보임으로서 년 평균 50% 이상의 난방 에너지를 절감할 수 있으며, 동절기 3-4개월의 집중 난방기에 에너지가 크게 절감됨을 발견할 수 있다. 4. 고온기 환기성능은 온실의 구조, 기상조건, 작물의 생육상태 등에 따라 다소의 차이가 있으나 환기율에 의해 크게 좌우되며, 시뮬레이션에 이용된 두 가지 농가보급형 온실 모두 환기율의 증가에 따른 실내기온의 강하 효과가 환기율이 1회/min 정도를 넘어서면서 급격히 둔화되는 현상을 보인다. 이는 기존에 권장되고 있는 적정 환기율인 1회/min 전후의 환기 시스템을 갖추는 것이 합리적임을 확인해 준다. 5. 작물이 성숙된 유리온실에서 외기의 상대습도가 50%인 쾌청한 주간동안 연속적으로 1회/min로 환기를 시킬 경우 실내기온 36.5$^{\circ}C$의 대조구에 비한 온도강하는 50% 차광만 했을 시 2.6$^{\circ}C$이고 효율 80%의 Pad & Fan 시스템만 작동시 6.1$^{\circ}C$ 정도이며, 차광과 냉각시스템을 동시에 작동시는 약 8.6$^{\circ}C$로서 외기온보다 3.3$^{\circ}C$가 낮은 28$^{\circ}C$까지 실내온도를 낮출 수 있으나, 동일 조건하에서 외기의 상대습도가 80%로 높은 경우에는 Pad & Fan시스템에 의한 온도강하가 2.4$^{\circ}C$에 불과하여 50% 차광하에서도 외기온 이하로 실내온도를 낮출 수 없음을 알 수 있다. 6. 하절기 3개월(6/1-8/31)동안 Pad & Fan 시스템의 냉방효과($\Delta$T)는 설정된 작동 온도에 따라 다소 차이를 보일 것으로 예상되나 본 시뮬레이션에서 설정한 시스템의 작동 온도 27$^{\circ}C$에서 상대습도와의 상관관계는 대략 다음과 같았다: $\Delta$T= -0.077RH+7.7 7. 전형적인 하절기 주간기상 하에서 경시적 냉방효과를 분석한 결과 환기만으로는 실내기온을 외기온 보다 5$^{\circ}C$ 높게 유지하는 정도가 고작이고, 차광이나 증발식 냉방시스템 만으로는 작물이 성숙한 단계에서조차도 외기온 이하로 떨어뜨리기가 어려우나 차광과 아울러 증발식 냉방을 병행할 경우에는 작물상태에 따라 다소 차이는 있지만 실내기온을 외기온보다 2.0-2.3$^{\circ}C$ 낮게 유지할 수 있음을 발견할 수 있다. 8. 일사가 차단된 27.5-28.5$^{\circ}C$의 외기온하에서 6.5-8.5$^{\circ}C$의 냉수를 온실 바닥면적 1$m^2$당 1.3 liter/min의 유량으로 온실표면에 살수했을 때 실내기온을 외기온보다 1$0^{\circ}C$ 낮은 16.5-18.$0^{\circ}C$ 정도로 낮출 수 있었다. 앞으로 살수 수온(T$_{w}$ )이나 외기온(T$_{o}$ ) 뿐만아니라 살수율(Q)에 따라 온실기온 (T$_{g}$ )에 미치는 상관 관계 T$_{g}$ = f(T$_{w}$ , Q, T$_{o}$ )를 구명하여 지하수 자체 또는 Heat Pump를 이용한 지하수온 이하의 냉수로 온실냉방의 가능성을 구명하는 것이 앞으로의 과제이다.

  • PDF