• Title/Summary/Keyword: High-Oxygen Concentration

Search Result 946, Processing Time 0.03 seconds

Effect of Oxygen Enrichment in a Swirling Diffusion Gas Burner (선회 확산버너에서 산소부화가 연소장에 미치는 영향)

  • Lee, Yong-Hoo;Lee, Jin-Seok;Lee, Woo-Seob;Lee, Do-Hyung
    • Journal of the Korean Society of Combustion
    • /
    • v.7 no.2
    • /
    • pp.34-41
    • /
    • 2002
  • To investigate the combustion characteristics of a swirling diffusion gas burner with oxygen enrichment, mean temperature, CO, $CO_2$, and HC concentrations were measured at various oxygen enrichment conditions. According to the results, the flame temperature increased and the region of high temperature was expanded with increasing oxygen concentration. The $CO_2$ concentrations increased, while the CO concentrations decreased in proportion to the increase of oxygen concentration. On the other hand, the HC concentrations were decreased and this tendency was very strong at the downstream of the combustor.

  • PDF

Effect of Mercury and Lead on the Biochemical Oxygen Demand (BOD) (수중(水中) 수은(水銀) 및 鉛(연)의 농도(濃度)가 BOD값에 미치는 영향(影響)에 관(關)하여)

  • Moon, Jai-Dong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.17 no.1
    • /
    • pp.217-221
    • /
    • 1984
  • In order to estimate interfering effects of mercury and lead on biochemical oxygen demand (BOD), BOD in 18 effluent samples were measured under three different concentrations of mercury and lead. The results obtained were as follows: 1. Biochemical oxygen demand(BOD) was decreased under the presence of mercury and lead, with parallel correlation of mercury concentration. 2. High correlations were noted between original BOD concentration and decreasing amount of BOD when concentrations of mercury or lead were increased. 3. When the lead concentration was high, the close correlation was observed between total organic carbon(TOC) and decreasing amount of BOD. 4. There was a negative correlation between TOC/BOD ratio and decreasing amount of BOD when the mercury concentrations were high.

  • PDF

Changes of Survival, Growth and Oxygen Consumption in the Oliver Flounder, Paralichthys olivaceus Exposed to TBT (TBT의 노출에 따른 넙치, Paralichthys olivaceus의 생존, 성장 및 산소소비의 변화)

  • 강주찬;황운기;지정훈
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.3
    • /
    • pp.219-224
    • /
    • 2002
  • This study was carried out to examine the effects of bis (tribytyltin)oxide (TBT), endocrine disrupting compounds (EDCs). on the changes of survival, growth and oxygen consumption rate in the oliver flounder, Paralichthys olivaceus. Oliver Flounders were exposed to sublethal concentration of TBT (0, 1.67, 3.20, 6.30 and 12.50 $\mu\textrm{g}$/L) during 6 weeks. Survival rate was decreased in a concentration and exposure period-dependent way and suddenly the reduction of more than 20% occurred at TBT concentration greater than 3.20 $\mu\textrm{g}$/L. after exposure 6 weeks. Growth rate and feed efficiency significantly decreased at concentration greater than 3.20 $\mu\textrm{g}$/L. Oxygen consumption rate was also decreased in a concentration-dependent way and significantly decreased to 17,48 and 67% than that of the control at the TBT concentration of 3.20, 6.32 and 12.50 $\mu\textrm{g}$/L, respectively. This study revealed that high TBT concentration ($\geq$3.20 $\mu\textrm{g}$/L) reduced growth and oxygen consumption rates of the juvenile oliver flounder suggesting potential influence on the natural mortality of Paralichthys olivaceus in the coastal areas.

Extent and persistence of dissolved oxygen enhancement using nanobubbles

  • Tekile, Andinet;Kim, Ilho;Lee, Jai-Yeop
    • Environmental Engineering Research
    • /
    • v.21 no.4
    • /
    • pp.427-435
    • /
    • 2016
  • In this study, change in water-dissolved oxygen (DO) was analyzed under various synthetic water qualities and nanobubbles (NBs) application conditions, such as gas type, initial DO as well as water dissolved, suspended and organic matters contents. When oxygen, rather than air, was introduced into nitrogen-desorbed ultra-pure water, the stagnation time was significantly increased. It took ten days for DO concentration to drop back to saturation. The higher the initial DO concentration, the longer particles were observed above saturation due to particle stability improvement. The oxygen mass transfer rate of 0.0482 mg/L/min was found to reach a maximum at an electrolytic concentration of 0.75 g/L, beyond which the transfer rate decreased due to adsorption of negative ions of the electrolyte at the interface. High levels of turbidity caused by suspended solids have become a barrier to dissolution of NBs oxygen into the water solution, and thus affected the transfer performance. On the other hand, by applying NBs for just an hour, up to 7.2% degradation of glucose as representative organic matter was achieved. Thus, NBs technology would maintain a high DO extent for an extended duration, and thus can improve water quality provided that water chemistry is closely monitored during its application.

A Study on the Relationship between Oxygen and Carrier Concentration in a GZO Film on an Amorphous Structure (GZO 박막에 대한 비정질 구조에 따른 산소공공과 전하농도의 연관성에 대한 연구)

  • Kim, Do Hyoung;Kim, Hong Bae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.4
    • /
    • pp.25-29
    • /
    • 2015
  • In this study, RF magnetron sputtering was used to investigate the relationship between oxygen vacancy and carrier concentration in a GZO film on an amorphous structure. RF power was fixed at 50W and Ar flow was changed on a glass plate to create a thin film at room temperature. The transmittance of Al-adopted amorphous GZO was measured at 85% or higher; therefore, the transmittance was shown to be outstanding in all films. The hall mobility was also shown to be higher at the film showing the high transmittance at a short-wavelength, whereas the optical energy gap was shown to be higher at the film with high oxygen vacancy. The oxygen vacancy at the amorphous oxide semi-conductor increased the optical energy gap while it was not directly involved in increasing the mobility. The oxygen vacancy increases the carrier concentration while lowering the quality of amorphous structure; such factor, therefore affected the mobility. The increase of amorphous property is a direct way to increase the mobility of amorphous oxide semi-conductor.

Comparing Physiological Changes in Breathing Conditions during Cognitive Tasks (인지부하 환경에서 호흡방식이 생체신호의 변화에 미치는 영향)

  • Jung, Ju-Yeon;Lee, Yeong-Bae;Park, Hyeon-Mi;Kang, Chang-Ki
    • Science of Emotion and Sensibility
    • /
    • v.25 no.2
    • /
    • pp.79-86
    • /
    • 2022
  • With external air pollution forcing many people indoors, new methods of facilitating healthier indoor life are necessary. This study, therefore, investigates the effects of indoor oxygen concentration and respiration methods on biosignals and cognitive ability. The study included twenty healthy subjects who inhaled air through a mask from a gas delivery system. All subjects were asked to perform three types of breathing (nasal, oral, and oral breathing with high oxygenation) and respond to cognitive stimuli (rest close eye, rest open eye, 1-back and 2-back working memory tasks). The changes in cognitive load according to respiration were analyzed by measuring response time, accuracy, and biosignals to stimuli. The result showed that, in all three respirations, heart rate significantly increased with the increase in cognitive load. Also, in oral respiration, the airway respiration rate significantly increased according to the increase in cognitive load. The change appeared to compensate for insufficient oxygen supply in oral respiration during cognitive activity. Conversely, there was no significant change in airway respiration rate during oral respiration with a high concentration oxygen supply as in nasal respiration. This result suggests that a high concentration oxygen supply might play a role in compensating for insufficient oxygen concentration or inefficient oxygen inhalation, such as oral respiration. Based on the results of this study, a follow-up study is necessary to determine the impact of changes in the autonomic nervous system, such as stress and emotions, to find out more precise and comprehensive effects of oxygen concentration and breathing type.

Oxygen Transfer Characteristics & Pure Oxygen Application Study on Circulation Flow Rate of the JLB (Jet Loop Bioreactor) (Jet 폭기 시스템의 순환유량에 따른 산소전달 특성 및 순산소 적용성 검토)

  • Park, Noh-Back;Song, Yong-Hyo;Pack, June-Gue;Jun, Hang-Bae
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.6
    • /
    • pp.896-901
    • /
    • 2009
  • In this study, in order to apply the air and pure oxygen in the Jet Loop Reactor (JLB) in which the oxygen transfer rate is high, differentiate the operation mode according to each air flowrate and liquid flowrate and investigate the oxygen transfer characteristic, an experiment was carried out. The oxygen concentration with the air flowrate ($Q_g$) and liquid flowrate ($Q_L$) was identical but the oxygen transfer coefficient ($K_L{\cdot}a$) is linear depending on degree of two factors. The width of an increase is small in $0.1min^{-1}$ when the air flowrate is 0.2 L/min with increasing the liquid flowrate. Whereas, the increment was exposed to be very high for $1.5min^{-1}$ when the air flowrate was 5 L/min. In the experiments using the pure oxygen, it was 30 mg/L of oxygen concentration finally and it was 3.5 times than using the air. But the time reached the saturated concentration was similar to using the air, and $K_L{\cdot}a$ was similar to using the air too. Analysis between two independent variable and oxygen transfer of the correlation is the same model like $K_L{\cdot}a={0.0161Q_L}^{1.5371}{Q_g}^{0.5433}$ using with coefficient non linear regression analysis. It was resulted that the liquid flowrate were approximately three times than air flowrate on effect to oxygen transfer rate.

A shell layer entrapping aerobic ammonia-oxidizing bacteria for autotrophic single-stage nitrogen removal

  • Bae, Hyokwan;Choi, Minkyu
    • Environmental Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.376-381
    • /
    • 2019
  • In this study, a poly(vinyl) alcohol/sodium alginate (PVA/SA) mixture was used to fabricate core-shell structured gel beads for autotrophic single-stage nitrogen removal (ASNR) using aerobic and anaerobic ammonia-oxidizing bacteria (AAOB and AnAOB, respectively). For stable ASNR process, the mechanical strength and oxygen penetration depth of the shell layer entrapping the AAOB are critical properties. The shell layer was constructed by an interfacial gelling reaction yielding thickness in the range of 2.01-3.63 mm, and a high PVA concentration of 12.5% resulted in the best mechanical strength of the shell layer. It was found that oxygen penetrated the shell layer at different depths depending on the PVA concentration, oxygen concentration in the bulk phase, and free ammonia concentration. The oxygen penetration depth was around $1,000{\mu}m$ when 8.0 mg/L dissolved oxygen was supplied from the bulk phase. This study reveals that the shell layer effectively protects the AnAOB from oxygen inhibition under the aerobic conditions because of the respiratory activity of the AAOB.

Effect of Ambient Conditions on the Soot Generation of Decane Fuel Droplet (분위기 조건이 Decane 액적의 Soot 생성에 미치는 영향)

  • Lim, Young Chan;Suh, Hyun Kyu
    • Journal of ILASS-Korea
    • /
    • v.19 no.4
    • /
    • pp.211-215
    • /
    • 2014
  • The main purpose of this study is to provide basic information of droplet soot generation of decane fuel. To achieve this, this paper presents the experimental results on the decane droplet combustion conducted under various ambient pressure($P_{amb}$), and oxygen concentration($O_2$) conditions. At the same time, the experimental study was conducted in terms of soot volume fraction($f_v$) and its maximum value. Also, visualization of single fuel droplet was conducted by high resolution CCD camera and ambient pressure($P_{amb}$) and oxygen concentration($O_2$) was changed by control system. It was revealed that higher ambient pressure($P_{amb}$), and oxygen concentration($O_2$) enhanced the soot generation and improved the maximum soot volume fraction( $f_v$).

High Concentration Ozone Generation Characteristics by Variation of Additional Gases and Flow Rates of Inlet Gas (입력가스의 유량변화와 첨가가스에 따른 고농도 오존발생특성)

  • 박승록;이대희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.95-101
    • /
    • 2002
  • There are many effective parameters to high concentration ozone generation. These parameters became very important elements should be considered before designing ozone generator. After designing, there are many peripheral parameters to greatly affect to high concentration ozone generation also. In this study, of many effective peripheral parameters on high concentration ozone generation, the effects of flow rate of inlet oxygen gas and some kinds of additional gases on ozone concentration were investigated As a result, when inlet oxygen gas was introduced at the range of 0.75[LPM]~2.00[LPM] the highest ozone concentration of 71145[ppm] was obtained at 1.25[LPM]. When the additional nitrogen gas was mixed to oxygen gas at the range of 0.0[vol%]~6.4[vol%] the highest ozone concentration of 73135[ppm] was obtained at 0.8[vol%] of nitrogen gas. This showed 3[%] increasing compared to the case of pure oxygen gas inlet. When the additional argon gas was mixed to oxygen gas at the range of 0.0[vol%]~6.4[vol%] the highest concentration of 67288[ppm]was obtained at 0.8[vol%]of argon gas. This is decreased value compared to that of introducing the pure oxygen.