• Title/Summary/Keyword: High-Oxygen Concentration

Search Result 946, Processing Time 0.027 seconds

Hydrogen photoproduction by the synchronously grown marine unicellular cyanobacterium Synechococcus sp. Miami BG 043511 under extremely high oxygen concentration

  • Yih, Won-Ho;Takeyama, Haruko;Mitsui, Akira
    • Journal of the korean society of oceanography
    • /
    • v.31 no.1
    • /
    • pp.18-22
    • /
    • 1996
  • The effect of exogenous oxygen on hydrogen photoproduction was examined in the synchronously grown cells of marine Synechococcus sp. Miami BG 043511 under conditions of high cell density (0.6-0.8 mg chl-${\alpha}$ $ml^{-1}$) and high light intensity (1000 ${\mu}$E $m^{-2}$ $s^{-1}$). Hydrogen evolution after 20-h incubation did not decline under the initial oxygen concentrations up to 20%, but declined by half under 34% oxygen. 50% and 100% oxygen gas phase did not completely inhibit the hydrogen photoproduction during 40-h incubations. After 2-day pretreatment under 100% exogenous oxygen the hydrogen photoproduction capabilities were not irreversibly inhibited, which was demonstrated in the subsequent 9-day incubation under initial 0, 50 and even under 100% oxygen gas phase. This strain could be useful for developing a hydrogen photoproduction system under atmospheric oxygen concentration.

  • PDF

The Effects of high Energy(1.5MeV) B+ ion Implantation and Initial Oxygen Concentration Upon Deep Level in CZ Silicon Wafer (고 에너지 (1.5 MeV) Boron 이온 주입과 초기 산소농도 조건이 깊은 준위에 미치는 영향에 관한 연구)

  • Song, Yeong-Min;Mun, Yeong-Hui;Kim, Jong-O
    • Korean Journal of Materials Research
    • /
    • v.11 no.1
    • /
    • pp.55-60
    • /
    • 2001
  • The effect of high energy B ion implantation and initial oxygen concentration upon defect formation and gettering of metallic impurities in Czochralski silicon wafer has been studied by applying DLTS( Deep Level Transient Spectroscopy), SIMS(Secondary ton Mass Spectroscopy), BMD (Bulk Micro-Defect) analysis and TEM(Transmission Electron Microscopy). DLTS results show the signal of the deep levels not only in as-implanted samples but also in low and high temperature annealed samples. Vacancy-related deep levels in as- implanted samples were changed to metallic impurities-related deep levels with increase of annealing temperature. In the case of high temperature anneal, by showing the lower deep level concentration with increase of initial oxygen concentration, high initial oxygen concentration seems to be more effective compared with the lower initial oxygen one.

  • PDF

The Evaluation of Oxygen Generator Performance For Car (차량용 산소발생기의 성능 측정)

  • Song, Kun-Ho;Yu, Jin-Ho;Kim, Jeong-Eun;Chang, Wha-Ik;Lee, Kwang-Rae
    • Journal of Industrial Technology
    • /
    • v.25 no.A
    • /
    • pp.151-156
    • /
    • 2005
  • Auto exhausts and air pollution can become trapped in the cabin of vehicle, reducing the amount of oxygen available for breathing. Driver may feel sleepy, headaches, nausea, confusion, dizziness and lower levels of oxygen can damage the driver's general health. Consequently, oxygen generator purified oxygen into the car to help driver get the oxygen driver's body needs. In this study, in order to evaluate the oxygen generator performance, the samples that the various conditions(humidity(50%, 100%), flow and oxygen concentration) were examined. There were three types of oxygen generator; sample 1($2.5{\ell}/min$, $36%O_2$), sample 2($4.5{\ell}/min$, $41%O_2$) and sample 3($5{\ell}/min$, $39%O_2$). As the humidity increased from 50% to 100%, the oxygen concentration of the sample 1(36%), 2(41%) and 3(39%) was reduced $31%O_2$, $38%O_2$ and $38%O_2$, respectively. Also, the each sample measured that effect of human in car on oxygen concentration, if the oxygen concentration is one person in car, each sample of oxygen concentration was $20.8%O_2$, $23.7%O_2$ and $21.2%O_2$. From the above results, it was shown that oxygen generator for car, if the oxygen concentration is increased, effect of humidity is reduced, and that in the sample of supplying a high-rate of oxygen, the oxygen concentration is increased. It was suggested that effect of humidity on oxygen generator for car can be reduced according to the supply of oxygen.

  • PDF

Production of High Purity Oxygen by Combination of Membrane and PSA Methods (분리막과 PSA혼합법에 의한 고순도 산소의 제조)

  • Hwang, Sun-Tak
    • Membrane Journal
    • /
    • v.4 no.1
    • /
    • pp.1-8
    • /
    • 1994
  • There are growing needs to produce relatively high purity(99.0% or higher) oxygen at low cost. For small scale production, both pressure swing adsorption(PSA) and membrane process are competitive and less expensive or more convenient than well known cryogenic fractionation technology. A continuous membrane column(CMC) combined with a PSA oxygen generator can be employed to produce high purity oxygen continuously. The oxygen enriched gas generated by a PSA unit, with a concentration of 93~94%, is fed to the CMC that consism of three modules of poly(imide) hollow fibers. Several experiments were conducted by varying parameters, such as feed flow rate, transmembrane pressure drop, stage cut, and feed location in order to obtain a high oxygen concentration above 99.0%. A two-series unit mode was also employed with CMC operation to optimize the given membrane area.

  • PDF

Production of High Purity Oxygen by Conbination of Membrane and PSA Methods

  • Hwang, Sun-Tak
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1994.03a
    • /
    • pp.1-21
    • /
    • 1994
  • There are growing needs to produce relatively high purity (99.0% or higher) oxygen at low cost. For small scale production, both pressure swing adsorption (PSA) and membrane process are competitve and less expensive or more convient than well known crygenic fractionation technology. A continuous membrane colume (CMC) combined with a PSA oxygen generator can be employed to produce high purity oxygen continuosly. The oxygen-enriched gas generated by a PSA unit, with a concentration of 93-94%, is fed to the CMC that consists of three modules of poly(imide) hollow fibers. Several experiments were conducted by varying parameters, such feed flow rate, transmenbrane pressure drop, stage cut, and feed location in order to obtain a high oxygen concentration above 99.0%. A two-series unit mode was also employed with CMC operation to optimize the given membrane area.

  • PDF

Research for High Quality Ingot Production in Large Diameter Continuous Czochralski Method (대구경 연속성장 초크랄스키법에서 고품질 잉곳 생산을 위한 연구)

  • Lee, Yu Ri;Jung, Jae Hak
    • Current Photovoltaic Research
    • /
    • v.4 no.3
    • /
    • pp.124-129
    • /
    • 2016
  • Recently industry has voiced a need for optimally designing the production process of low-cost, high-quality ingots by improving productivity and reducing production costs with the Czochralski process. Crystalline defect control is important for the production of high-quality ingots. Also oxygen is one of the most important impurities that influence crystalline defects in single crystals. Oxygen is dissolved into the silicon melt from the silica crucible and incorporated into the crystalline a far larger amount than other additives or impurities. Then it is eluted during the cooling process, there by causing various defect. Excessive quantities of oxygen degrade the quality of silicone. However an appropriate amount of oxygen can be beneficial. because it eliminates metallic impurities within the silicone. Therefore, when growing crystals, an attempt should be made not to eliminate oxygen, but to uniformly maintain its concentration. Thus, the control of oxygen concentration is essential for crystalline growth. At present, the control of oxygen concentration is actively being studied based on the interdependence of various factors such as crystal rotation, crucible rotation, argon flow, pressure, magnet position and magnetic strength. However for methods using a magnetic field, the initial investment and operating costs of the equipment affect the wafer pricing. Hence in this study simulations were performed with the purpose of producing low-cost, high-quality ingots through the development of a process to optimize oxygen concentration without the use of magnets and through the following. a process appropriate to the defect-free range was determined by regulating the pulling rate of the crystals.

Role of oxygen in plasma induced chemical reactions in solution

  • Ki, Se Hoon;Uhm, Han Sup;Kim, Minsu;Baik, Ku Youn;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.208.2-208.2
    • /
    • 2016
  • Many researchers have paid attention to the studies on the interaction between non-thermal plasma and aqueous solutions for biomedical applications. The gas composition in the plasma is very important. Oxygen and nitrogen are the main gases of interest in biological applications. Especially, we focus on the oxygen concentration. In this experiment, we studied the role of oxygen concentration in plasma induced chemical reactions in solution. At first, the amount of ions are measured according to changing the oxygen concentration. And we checked the relationship between these ions and pH value. Secondly, when the oxygen concentration is changed, it identified the type and amount of radical generated by the plasma. In order to confirm the effect of these chemical property change to biological material, hemoglobin and RBCs are chosen. RBCs are one of the common basic biological cells. Thirdly, when plasma treated according to oxygen concentration in nitrogen feeding gas, oxidation of hemoglobin and RBC is checked. Finally, membrane oxidation of RBC is measured to examine the relation between hemoglobin oxidation and membrane damage through relative hemolysis and Young's modulus. Our results suggest that reactive species generated by the plasma differsdepending on the oxygen concentration changes. The pH values are decreased when oxygen concentration increased. OH decrease and NO increase are also observed. These reactive species makes change of chemical properties of solution. We also able to confirm that the difference in these reactive species to affect the oxidation of the Hb and RBCs. The Hb and RBCs are more oxidized with the high oxygen concentration conditions. But membrane is damaged more by plasma treatment with only nitrogen gas. It is shown that red blood cells membrane damage and oxidation of hemoglobin are not directly related.

  • PDF

Control of Both Foam and Dissolved Oxygen in the Presence of a Surfactant for Production of $\beta$-Carotene in Blakeslea trispora

  • Kim, Seon-Won;Lee, In-Young;Jeong, Jae-Cheol;Lee, Jung-Heon;Park, Young-Hoon
    • Journal of Microbiology and Biotechnology
    • /
    • v.9 no.5
    • /
    • pp.548-553
    • /
    • 1999
  • A production of $\beta-Carotene$was attempted in a fed-batch culture of Blakeslea trispora by controlling both foam and dissolved oxygen in the presence of surfactant, Span 20. Results obtained from the shake flask cultures indicated that a high concentration of dissolved oxygen was needed for both cell growth and $\beta-Carotene$ synthesis, and the optimal concentration of glucose was found to be in the range of 50-100 g/l. In order to maintain the dissolved oxygen concentration level at higher than 50% of air saturation, pure oxygen was automatically sparged into the medium with air. Foam was controlled by bypassing air from the submerged aeration to the headspace in response to the foam that was caused by Span 20. High agitation speed was found to be detrimental to the cell growth due to shear damage, even though it provided sufficient dissolved oxygen. On the other hand, a low aeration speed caused stagnant regions in the fermentor because of improper mixing. Thus, for the fed-batch operation, agitation speed was increased gradually from 300 to 700 rpm to prevent cell damage at the initial stage of fermentation and to give efficient mixing for a viscous culture broth as the culture proceeded. By controlling dissolved oxygen and foam, a high concentration of $\beta-Carotene$otene (1,190 mg/l) was obtained in 6 days of the fed-batch culture of B. trispora with 2.5% of the dry cell weight, which was approximately 5 times higher than that of the batch cultures.

  • PDF

Enhancement of Anticancer Effect through Photodynamic Therapy with High Oxygen Concentration

  • Kim, Yun-Ho;Chung, Phil-Sang;Lee, Sang-Joon;Shin, Jang-In;Hwang, Hee-Jun;Ahn, Jin-Chul
    • Biomedical Science Letters
    • /
    • v.15 no.1
    • /
    • pp.87-91
    • /
    • 2009
  • In photodynamic therapy (PDT), oxygen plays important role. Because of singlet oxygen which is produced by activated photosensitizer after laser irradiation of specific wavelength. The aim of this study is to find how oxygen concentration affects anticancer effect in PDT. Groups were divided into PDT with oxygen applied group and only PDT applied group. PDT with oxygen applied group supplied oxygen for 15 minute before laser irradiation. In vitro, CT-26 cell was incubated with various concentration of photofrin $(50.0{\sim}0.05{\mu}g/ml)$ and was irradiated with 632nm diode laser 6hr after application of photofrin. The cell viability of two groups was assessed by MTT assay. In vivo, CT-26 cell line was transplanted into the subcutaneous tissue of BALB/c mouse. The anticancer effect of two groups was measured by tumor volume change. In vitro study, the cell viability was significantly decreased at $1.56{\sim}3.13{\mu}g/ml$ in PDT with oxygen applied group. In vivo study, the PDT with oxygen applied group significantly higher reduction rate of tumor volume 7 days after PDT compared to PDT only group. The high oxygen concentration might enhance the anticancer effect of the photodynamic therapy.

  • PDF

Combustion characteristics inside the furnace with a flat flame burner by oxygen enriched and swirled air (산소부화와 선회수에 따른 평면화염버너의 로 내 연소특성)

  • Kwark, Ji-Hyun;Jeon, Chung-Hwan;Chang, Young-June
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.177-184
    • /
    • 2001
  • Combustion using oxygen enriched air is an energy saving technology that can increase thermal efficiency by the improvement of burning rate and high temperature flame. But information about it is not so enough yet. Flame figure, temperature distribution and emission concentration were measured with oxygen enriched concentration and swirl number in a turbulent diffusion flame to investigate the combustion characteristics. The results showed that flame figure became different as long as oxygen enriched concentration varied and that concentration of NO increased suddenly around $O_2$ 60%.

  • PDF