• Title/Summary/Keyword: High-Frequency isolated

Search Result 241, Processing Time 0.025 seconds

Studies on the Antimicrobial Susceptibility of Enterococci isolated at Doctorless areas and Seoul National University Hospital (일부 무의촌지역과 병원에서 분리한 Enterococci의 항균제 감수성에 관한 연구)

  • Kim, Ik-Sang;Shin, Hee-Sup;Rhee, Kwang-Ho;Chang, Woo-Hyun;Lim, Jung-Kyoo
    • The Journal of the Korean Society for Microbiology
    • /
    • v.13 no.1
    • /
    • pp.63-73
    • /
    • 1978
  • 28 strains of Enterococci isolated at doctorless areas in Korea from Oct. 1976 through Mar. 1977 and 30 strains of Enterococci isolated at Seoul National University Hospital from Sep. 1976 through Dec. 1976 were examined for susceptibilities to 14 antimicrobial agents by agar dilution method. The susceptibilities of two groups to each antimicrobial agent were compared and incidence of resistant strains in each antimicrobial agent, incidence of multiply resistant strains and correlations in the antimicrobial susceptibility of 58 strains of Enterococci among 14 antimicrobial agents were analyzed. 1. With Tetracycline, Oxytetracline, Doxycycline, Minocycline and Erythromycin, the mean MIC's of Enterococci isolated at Seoul National University Hospital were 1.9-2.5 times higher than those of Enterococci isolated at doctorless areas, though there were no statistical significance. 2. Frequency of resistant strains in Enterococci isolated at Seoul National University Hospital was the highest with Cephalexin(100%), Gentamicin(100%), and Streptomycin(100%), followed by Kanamycin(93.3%), Carbenicillin(90%), Tetracycline(26.7%), Oxytetracycline(26.7%), Doxycycline(26.7%), Minocycline(20%), Erythromycin(10%), Troleandomycin(10%), Penicillin(6.7%), Cotrimoxazole(6.7%) and Ampicillin(0%). 3. Frequency of resistant strains in Enterococci isolated at doctorless areas was the highest with Kanamycin(100%) and Streptomycin(100%), followed by Cephalexin(96.4%), Gentamicin(96.4%), Carbenicillin(92.9%), Tetracycline(10.7%), Oxytetracycline(10.7%), Doxycycline(10.7%), Minocycline(10.7%), Cotrimoxazole(10.7%), Penicillin(3.6%), Ampicillin(0%), Erythromycin(0%), and Troeandomycin(0%). 4. In study with Penicillin, Ampicillin, Tetracycline, Cotrimoxazole, Erythromycin and Troleandomycin, there were no multiply resistant strains in Enterococci isolated at doctorless areas, while 4 strains of Enterococci isolated at Seoul National University Hospital showed multiple resistance. 5. There were high correlation in susceptibility of 58 strains of Enterococci among Tetracycline, Oxytetracycline, Doxycycline and Minocycline(correlation coefficients 0.86-0.97). Correlation coefficients of susceptibility among penicillin analogues(Penicillin, Ampicillin, Carbenicillin and Cephalexin) ranged between 0.75-0.89. Correlation coefficients of susceptibility among aminoglycosides(Kanamycin, Gentamicin and Streptomycin) ranged between 0.09-0.51.

  • PDF

An Improved Switching Topology for Single Phase Multilevel Inverter with Capacitor Voltage Balancing Technique

  • Ponnusamy, Rajan Soundar;Subramaniam, Manoharan;Irudayaraj, Gerald Christopher Raj;Mylsamy, Kaliamoorthy
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.115-126
    • /
    • 2017
  • This paper presents a new cascaded asymmetrical single phase multilevel converter with a reduced number of isolated DC sources and power semiconductor switches. The proposed inverter has only two H-bridges connected in cascade, one switching at a high frequency and the other switching at a low frequency. The Low Switching Frequency Inverter (LSFI) generates seven levels whereas the High Switching Frequency Inverter (HSFI) generates only two levels. This paper also presents a solution to the capacitor balancing issues of the LSFI. The proposed inverter has lot of advantages such as reductions in the number of DC sources, switching losses, power electronic devices, size and cost. The proposed inverter with a capacitor voltage balancing algorithm is simulated using MATLAB/SIMULINK. The switching logic of the proposed inverter with a capacitor voltage balancing algorithm is developed using a FPGA SPATRAN 3A DSP board. A laboratory prototype is built to validate the simulation results.

A 0.25-$\mu\textrm{m}$ CMOS 1.6Gbps/pin 4-Level Transceiver Using Stub Series Terminated Logic Interface for High Bandwidth

  • Kim, Jin-Hyun;Kim, Woo-Seop;Kim, Suki
    • Proceedings of the IEEK Conference
    • /
    • 2002.06b
    • /
    • pp.165-168
    • /
    • 2002
  • As the demand for higher data-rate chip-to-chip communication such as memory-to-controller, processor-to-processor increases, low cost high-speed serial links\ulcorner become more attractive. This paper describes a 0.25-fm CMOS 1.6Gbps/pin 4-level transceiver using Stub Series Terminated Logic for high Bandwidth. For multi-gigabit/second application, the data rate is limited by Inter-Symbol Interference (ISI) caused by channel low pass effects, process-limited on-chip clock frequency, and serial link distance. The proposed transceiver uses multi-level signaling (4-level Pulse Amplitude Modulation) using push-pull type, double data rate and flash sampling. To reduce Process-Voltage-Temperature Variation and ISI including data dependency skew, the proposed high-speed calibration circuits with voltage swing controller, data linearity controller and slew rate controller maintains desirable output waveform and makes less sensitive output. In order to detect successfully the transmitted 1.6Gbps/pin 4-level data, the receiver is designed as simultaneous type with a kick - back noise-isolated reference voltage line structure and a 3-stage Gate-Isolated sense amplifier. The transceiver, which was fabricated using a 0.25 fm CMOS process, performs data rate of 1.6 ~ 2.0 Gbps/pin with a 400MHB internal clock, Stub Series Terminated Logic ever in 2.25 ~ 2.75V supply voltage. and occupied 500 * 6001m of area.

  • PDF

Serviceability-oriented analytical design of isolated liquid damper for the wind-induced vibration control of high-rise buildings

  • Zhipeng Zhao;Xiuyan Hu;Cong Liao;Na Hong;Yuanchen Tang
    • Smart Structures and Systems
    • /
    • v.33 no.1
    • /
    • pp.27-39
    • /
    • 2024
  • The effectiveness of conventional tuned liquid dampers (TLDs) in controlling the wind-induced response of tall flexible structures has been indicated. However, the impaired control effect in the detuning condition or a considerably high mass cost of liquid may be incurred in ensuring the high-level serviceability. To provide an efficient TLD-based solution for wind-induced vibration control, this study proposes a serviceability-oriented optimal design method for isolated TLDs (ILDs) and derives analytical design formulae. The ILD is implemented by mounting the TLD on the linear isolators. Stochastic response analysis is performed for the ILD-equipped structure subjected to stochastic wind and white noise, and the results are considered to derive the closed-form responses. Correspondingly, an extensive parametric analysis is conducted to clarify a serviceability-oriented optimal design framework by incorporating the comfort demand. The obtained results show that the high-level serviceability demand can be satisfied by the ILD based on the proposed optimal design framework. Analytical design formulae can be preliminarily adopted to ensure the target serviceability demand while enhancing the structural displacement performance to increase the safety level. Compared with conventional TLD systems, the ILD exhibits higher effectiveness and a larger frequency bandwidth for wind-induced vibration control at a small mass ratio.

High prevalence of Enterococcus spp. from dogs with otitis externa

  • Jo, Hyun-Jung;Chae, Hee-Sun;Kim, Hyun-Ju;Kim, Min-Ju;Park, Gyu-Nam;Kim, Sang-Hun;Chang, Kyung-Soo
    • Korean Journal of Veterinary Service
    • /
    • v.35 no.2
    • /
    • pp.99-104
    • /
    • 2012
  • Otitis externa (OE) is a frequent disease in the ear canals of dogs. To identify the pathogens causing OE in dogs and to determine their antimicrobial resistances, specimens were collected from animal hospitals in Daejeon. The isolates were examined by morphological and biochemical tests, 16S rRNA analysis and antimicrobial susceptibility tests. We analyzed correlation between the isolated pathogens and external factors of dogs such as breed, age, gender, ear mite, hair in ears and experience with antibiotic therapy. Thirty three strains of bacteria were isolated from 26 of the 68 heads of dogs with OE. The most isolated bacteria were Enterococcus faecalis (E. faecalis) followed by Staphylococcus aureus (Sta. aureus), Sta. pseudointermedius, E. faecium, E. avium and Streptococcus canis (Strep. canis) in order of frequency of occurrence. Isolation frequency of Enterococcus spp. and Staphylococcus spp. were 51.5% and 45.5%, respectively. E. faecalis and E. faecium isolates showed VanB phenotype, which is resistant to vancomycin but sensitive to teicoplanin were 58% and 25%, respectively. Nine isolates among total twelve isolates of E. faecalis were isolated from the dogs treated with antibiotics. There was no methicillin-resistant Sta. aureus (MRSA), but were MR-Sta. pseudointermedius (MRSP) (57.1%) and vancomycin-resistant (VR)-Sta. pseudointermedius (14.3%) (VRSP) showing VanB phenotype. However, vanA, vanB and vanC genes were not detected in VR isolates from the dogs. Taken together, VR-Enterococcus spp. (VRE) is one of the major pathogens in domestic animals, as well as community-and hospital-acquired infection.

High-Frequency Soft-Switching PWM DC-DC Power Converter for Low Voltage Large Current Applications

  • Muraoka Hidekazu;Sakamoto Kenya;Nakaoka Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.198-202
    • /
    • 2001
  • This paper presents a novel prototype version of ZCS-PWM forward DC-DC power converter using power MOSFETs which is designed for application specific low voltage large current conversion operation. The soft-switching forward power converter with a high frequency isolated transformer link which can efficiency operate over wide load ranges under two conditions of ZCS as well as active voltage clamped switching is evaluated and discussed on the basis of the simulation and experimental results.

  • PDF

Development of 3.0[kW]class Fuel Cell Power Conversion System (3[kW]급 연료전지용 전력변환장치의 개발)

  • Suh, Ki-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.2
    • /
    • pp.54-63
    • /
    • 2007
  • Recently, a fuel cell with low voltage and high current output characteristics is remarkable for new generation system. It needs both a DC-DC step-up converter and DC-AC inverter to be used in fuel cell generation system. Therefor, this paper, consists of an isolated DC-DC converter to boost the fuel cell voltage $380[V_{DC}]$ and a PWM inverter with LC filter to convent the DC voltage to single-phase $220[V_{AC}]$. Expressly, a tapped inductor filter with freewheeling diode is newly implemented in the output filter of the proposed high frequency isolated ZVZCS PWM DC-DC converter to suppress circulating current under the wide output voltage regulation range, thus to eliminate the switching and transformer turn-on/off over-short voltage or transient phenomena. Besides the efficiency of 93-97[%]is obtained over the wide output voltage regulation ranges and load variations.

Mechanism of Inhibition of Cardiac Muscle Contractility by Ryanodine (심근 수축력 저하를 유발하는 Ryanodine의 작용 기전)

  • Ahn, Duck-Sun;Suh, Chang-Kook;Kang, Doo-Hee
    • The Korean Journal of Physiology
    • /
    • v.21 no.2
    • /
    • pp.179-189
    • /
    • 1987
  • Since it has been known that ryanodine has a potent negative inotropic effect on the cardiac muscle contractility (Jenden and Fairhurst, 1968), ryanodine has been a subject of intensive research (Frank and Sleator, 1975; Jones et al, 1978; Sutko et al, 1985). However, the underlying mechanism for the ryanodine dependent negative inotropic effect is still uncertain. In this study, the effects of ryanodine on the generation and relaxation of contracture due to Na-withdrawal and on the force-frequency relationship of heart muscles isolated from rats and guinea pigs were measured in an effort to understand the underlying mechanism of the ryanodine-induced negative inotropy. Results are summerized as follows: 1 ) Ryanodine significantly reduced the contractility of heart muscles produced at low frequency of stimulation, but showed a little effect on the contractility at high frequency stimulation. 2) Ryanodine, at the concentrations ranging from $10^{-6}\;M$ to $10^{-8}\;M$, had no significant effect on the Na-dependent relaxation of Na-withdrawl contracture. 3) Ryandoine significantly reduced the amplitude of the Na-withdrawl contracture, and this inhibitory effect was reinforced by procaine, antiagonized by caffeine and high potassium. From these results, it may be concluded that the negative inotropic effect of ryanodine is mainly due to an inhibition of calcium release from sarcoplasmic reticulum.

  • PDF

Thai Phoneme Segmentation using Dual-Band Energy Contour

  • Ratsameewichai, S.;Theera-Umpon, N.;Vilasdechanon, J.;Uatrongjit, S.;Likit-Anurucks, K.
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.110-112
    • /
    • 2002
  • In this paper, a new technique for Thai isolated speech phoneme segmentation is proposed. Based on Thai speech feature, the isolated speech is first divided into low and high frequency components by using the technique of wavelet decomposition. Then the energy contour of each decomposed signal is computed and employed to locate phoneme boundary. To verity the proposed scheme, some experiments have been performed using 1,000 syllables data recorded from 10 speakers. The accuracy rates are 96.0, 89.9, 92.7 and 98.9% for initial consonant, vowel, final consonant and silence, respectively.

  • PDF

Multi-Step Analysis of Seismically Isolated NPP Containment Structures with Lead-Rubber Bearings (납-고무받침에 의해 면진된 원전 격납구조물의 다중단계해석)

  • Lee, Jin Hi;Song, Jong-Keol;Lee, Eun-Haeng
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.18 no.6
    • /
    • pp.261-269
    • /
    • 2014
  • In order to increase the seismic safety of nuclear power plant (NPP) structures in high seismicity regions, seismic isolation techniques can be adapted to NPP structures. In this paper, the applicability of multi-step analysis of seismically isolated NPP containment structures with lead-rubber bearings (LRB) is evaluated. The floor response spectrum of NPP containment structures with equivalent linear LRB and nonlinear LRB are compared. In addition, the force-displacement relationships for equivalent linear LRB and nonlinear LRB are compared.