• Title/Summary/Keyword: High-Frequency isolated

Search Result 241, Processing Time 0.024 seconds

Isolation of Antibiotic-producing Microorganisms Antagonistic to Soilborne Pathogenic Fungi of Bentgrass and Their Antifungal Activity (잔디 토양전염성병원진균에 대한 길항미생물의 분리 및 길항효과)

  • 이용세;전하준;이창호;송치현
    • Korean Journal of Organic Agriculture
    • /
    • v.6 no.1
    • /
    • pp.133-149
    • /
    • 1997
  • Recently, the importance of management and cultivation of grasses has been increased in Korea. Among these cultural practices, the appropriate control of diseases is considered more important than other cultivation techniques such as fertilization and irrigation. The damages of brown patch and large patch caused by Rhizoctonia spp. and Pythium blight caused by Pythium spp. are serious in the major cultivation area of turfgrass in Korea. Since these diseases are difficult to control by agrochemicals, the damages are very serious if these are occured. The periodic spray of agrochemicals, to protect and control these diseases could make some problems of toxicity and environmental pollution as well as rising of non-target diseases. Therefore, the biological methods to control diseases have been required to decrease problems resulted from overuse of agrochemicals, to conserve natural ecosystem, and to control effectively diseases of grasses in the long period. The number of studies about biological control using antagonistic microorganisms have been increased for last half century. However, the application of biological control method has been very limited. In this study, thirteen isolates of R. cerealis, 8 isolates of R. solani and 3 isolates of Phthyn spp. have been isolated from diseased turfgrass in golf course and grass-culture area that have patch and wilting symptoms of zoysia grass and creeping bentgrass. Isolation frequency of R. cerealis and R. solani was high in especially zoysiagrass, while Pythym spp. was isolated from bent grass at low frequency but showed high pathogenicity. Totally, 205 isolates of soil microorganisms were isolated in this study as primary antagonistic microorganism by Herr's triple agar layer plate and dual culture method using rhizosphere of grasses, soil of crop field as the source of antagonistic microorganisms. Among the 205 isolates, 23 isolates were actinomycetes and 182 isolates were bacteria. All of the actinomycetes were isolated by Herr's method. Antagonistic effect of primary isolated microorganisms was tested for in vitro mycelial growth inhibition against pathogenic fungi isolated from grasses and for inhibition of disease occurrence in 24 well tissue culture plate and pot experiment. Then, four isolated of bacteria which are BG23, BG74, BG136 and BG171 were selected as antagonistic microorganisms against soil-born pathogenic fungi of bentgrass.

  • PDF

Characteristics of Non-Isolated OSAKA Converter -Characteristics of Three-Phase Soft-Switching Power Factor Corrected Converter for Large Scale Power Without Three-Phase Transformer-

  • Taniguchi, Katsunori;Shimomori, Wataru;Lee, Hyun-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1383-1386
    • /
    • 2005
  • Non-isolated OSAKA Converter, which removes a three-phase transformer, is described in this paper. The converter switches once in every half cycle of an AC commercial power source. Therefore, it can solve many problems caused by the high frequency operation. The proposed converter achieves the soft-switching operation and the EMI noise can be reduced. In this circuit, the resonant capacitor, which is used for the soft-switching operation, is utilized for the improvement of an input current waveform. To achieve low cost and compact structure, non-isolated OSAKA converter removes a three-phase transformer of the OSAKA converter. By removing the three-phase transformer, three phase currents occur the interferences each other. To avoid the interference, a new switching method for non-isolated OSAKA converter is preposed. The converter can be constructed by the low-speed large power devices. The converter generates the low distorted input current waveforms with high power factor.

  • PDF

Design of a Digital PWM Controller for a Soft Switching SEPIC Converter

  • Nashed, Maged N.F.
    • Journal of Power Electronics
    • /
    • v.4 no.3
    • /
    • pp.152-160
    • /
    • 2004
  • This paper presents analysis, modeling, and design of a low-harmonic, isolated, active-clamped SEPIC for future avionics applications. Simpler converter dynamics, high switching frequency, zero voltage-Transition-PWM switching, and a single-layer transformer construction result. This paper describes complete design of a digital controller for a high-frequency switching power supply. Guidelines for the minimum required resolution of the analog-to-digital converter, the pulse-width modulator, and the fixed-point computational unit is derived. A design example based on a SEPIC converter operating at the high switching frequency is presented. The controller design is based on direct digital design approach and standard root-locus techniques.

Seismic Responses of Seismically-Isolated Nuclear Power Plants considering Aging of High Damping Rubber Bearing in Different Temperature Environments (다른 온도환경에서 고감쇠고무 적층받침의 경년열화를 고려한 면진 원전구조물의 지진응답)

  • Park, Junhee;Choun, Young-Sun;Choi, In-Kil
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.5
    • /
    • pp.385-392
    • /
    • 2014
  • The isolators have been generally used to reduce a seismic force. If the isolators apply to the nuclear power plants(NPPs), the durability and capacity for the structures and equipments should be ensured during the life time. In this study, the long-term behavior of isolated NPPs was analyzed for ensuring the seismic safety. The properties of isolator due to the age-related degradation were analyzed. And the seismic behavior of isolated buildings was analyzed by considering the aging of rubber bearings in different temperature environments. According to the analysis results, the natural frequency of structures was increased with time. But the maximum acceleration and maximum displacement of isolated structures have not changed significantly. Although the damaged of structure did not occurred by aging of isolators, it was presented that the spectral acceleration at the target frequency of isolated structure increased with the temperature. Therefore the isolators in the isolated buildings should be carefully designed and manufactured considering the temperature-dependancy of rubber material.

Real-time hybrid substructuring of a base isolated building considering robust stability and performance analysis

  • Avci, Muammer;Botelho, Rui M.;Christenson, Richard
    • Smart Structures and Systems
    • /
    • v.25 no.2
    • /
    • pp.155-167
    • /
    • 2020
  • This paper demonstrates a real-time hybrid substructuring (RTHS) shake table test to evaluate the seismic performance of a base isolated building. Since RTHS involves a feedback loop in the test implementation, the frequency dependent magnitude and inherent time delay of the actuator dynamics can introduce inaccuracy and instability. The paper presents a robust stability and performance analysis method for the RTHS test. The robust stability method involves casting the actuator dynamics as a multiplicative uncertainty and applying the small gain theorem to derive the sufficient conditions for robust stability and performance. The attractive feature of this robust stability and performance analysis method is that it accommodates linearized modeled or measured frequency response functions for both the physical substructure and actuator dynamics. Significant experimental research has been conducted on base isolators and dampers toward developing high fidelity numerical models. Shake table testing, where the building superstructure is tested while the isolation layer is numerically modeled, can allow for a range of isolation strategies to be examined for a single shake table experiment. Further, recent concerns in base isolation for long period, long duration earthquakes necessitate adding damping at the isolation layer, which can allow higher frequency energy to be transmitted into the superstructure and can result in damage to structural and nonstructural components that can be difficult to numerically model and accurately predict. As such, physical testing of the superstructure while numerically modeling the isolation layer may be desired. The RTHS approach has been previously proposed for base isolated buildings, however, to date it has not been conducted on a base isolated structure isolated at the ground level and where the isolation layer itself is numerically simulated. This configuration provides multiple challenges in the RTHS stability associated with higher physical substructure frequencies and a low numerical to physical mass ratio. This paper demonstrates a base isolated RTHS test and the robust stability and performance analysis necessary to ensure the stability and accuracy. The tests consist of a scaled idealized 4-story superstructure building model placed directly onto a shake table and the isolation layer simulated in MATLAB/Simulink using a dSpace real-time controller.

Investigating Dynamic Characteristics on Support Base for IPB Duct System and Reducing Vibration for IPB Duct (IPB 덕트의 진동저감과 기초에 대한 동특성 고찰)

  • Yang, Kyeong-Hyeon;Cho, Chul-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.495-500
    • /
    • 2001
  • Because of resonance between natural frequency of the second floor base for IPB(Isolated Phase Bus) duct supports in a power plant and operation frequency of the turbine, there was high amplitude vibration on IPB duct. To reduce vibration of IPB duct, Firstly it was set a FEM model to seek the mode shape for the concrete structure. Secondly, it was carried out dynamic analysis for the FEM model. Lastly, because the natural frequency of the concrete structure could not be changed, it was changed supports position for the IPB duct near to beams. It resulted in reducing vibration of IPB duct.

  • PDF

The Secondary LLC Series Resonant Converter for the Boost DC/DC Converter (변압기 2차측 LLC 직렬공진컨버터 적용 승압형 DC/DC 컨버터)

  • Lee Hyun-Kwan;Lee Gi-Sik;Chung Bong-Geon;Kong Young-Su;Kim Eun-Soo;Cha In-Su;Yoon Jeong-Phil
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.277-280
    • /
    • 2006
  • Recently, the high frequency isolated boost DC/DC converter has been widely used for the PCS (Power Conditioning System) system because of its small size and low cost. However, the high frequency isolated boost DC/DC converters applied the conventional voltage-fed converter and current-fed converter have the problems such as the high conduction losses and the surge voltage due to the high circulating current and the leakage inductance, respectively. To overcome this problems, in this paper the secondary LLC resonant converter is proposed, and the experimental results of the secondary LLC series resonant converter for boost DC/DC converter are verified on the simulation based on the theoretical analysis and the 1kW experimental prototype.

  • PDF

High-Frequency GaN HEMTs Based Point-of-Load Synchronous Buck Converter with Zero-Voltage Switching

  • Lee, Woongkul;Han, Di;Morris, Casey T.;Sarlioglu, Bulent
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.601-609
    • /
    • 2017
  • Gallium nitride (GaN) power switching devices are promising candidates for high switching frequency and high efficiency power conversion due to their fast switching, low on-state resistance, and high-temperature operation capability. In order to facilitate the use of these new devices better, it is required to investigate the device characteristics and performance in detail preferably by comparing with various conventional silicon (Si) devices. This paper presents a comprehensive study of GaN high electron mobility transistor (HEMT) based non-isolated point-of-load (POL) synchronous buck converter operating at 2.7 MHz with a high step-down ratio (24 V to 3.3 V). The characteristics and performance of GaN HEMT and three different Si devices are analytically investigated and the optimal operating point for GaN HEMT is discussed. Zero-voltage switching (ZVS) is implemented to minimize switching loss in high switching frequency operation. The prototype circuit and experimental data support the validity of analytical and simulation results.

Development a High-Efficiency Induction Heating Heater using a 5[kW] Class Full-Bridge High Frequency Resonant Inverter (5[kW]급 풀-브릿지 고주파 공진형 인버터를 이용한 고효율 유도가열 히터 개발)

  • Kwon Hyuk-Min;Shin Dae-Cheul
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.481-487
    • /
    • 2005
  • Proposed induction-heated system is innovative system which applied special high-frequency power circuit technique for thermal converse technique and IH(Induction-Heating) magnetic induction heating generated from induction-heated metallic package that is for distillation unit. In this occurs not burning, so that the working environment can be improved. This electromagnetic induction heating technique is used high frequency inverter, By using high frequency inverter high frequency alternative current in the range of [kHz] can be made with conventional alternative current. In this contribution IGBT module is used for high frequency inverter. This paper proposes new fluid heating method. Which is operated as follows. Working coil, which is wrapped outside of pipeline, makes the eddy current. Inside of heating vessel in isolated pipeline the specially designed stainless metallic package is inserted, which can be heated by eddy current losses. And then In this paper are discussed action analysis and characteristics analysis of 5[kW] class full-bridge resonant inverter system and resonant metallic package. In addition, by using this system, how high-efficiency heater is developed and application of system are also discussed.

A MOSFET's Driver Applied to High-frequency Switching with Wide Range of Duty Cycles

  • Zhang, Zhao;Xie, Shaojun
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1402-1408
    • /
    • 2015
  • A MOSFET's gate driver based on magnetic coupling is investigated. The gate driver can meet the demands in applications for wide range of duty cycles and high frequency. Fully galvanic isolation can be realized, and no auxiliary supply is needed. The driver is insensitive to the leakage inductor of the isolated transformer. No gate resistor is needed to damp the oscillation, and thus the peak output current of the gate driver can be improved. Design of the driving transformer can also be made more flexible, which helps to improve the isolation voltage between the power stage and the control electronics, and aids to enhance the electromagnetic compatibility. The driver's operation principle is analyzed, and the design method for its key parameters is presented. The performance analysis is validated via experiment. The disadvantages of the traditional magnetic coupling and optical coupling have been conquered through the investigated circuit.