• 제목/요약/키워드: High-Frequency Ventilation

검색결과 56건 처리시간 0.027초

실습선의 소음과 진동 특성 해석 (The characteristic analysis of noise and vibration in training ship)

  • 강창남
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1012-1013
    • /
    • 2006
  • Marine technology must advance to meet the needs of a wealthier and more demanding public while at the same time provide greater environmental protection. Pollution noise and vibration is the specific issue being discussed in this paper Noise is of course due to vibration from high speed engines driving generators, entilators, winch and other gear, while underwater noise pollution results from the propellers and the resistance produced by the hull of the ship moving through the water. Vibration is also a factor in potential damage to sensitive electronic gear and metal fatigue. The issue of noise pollution does not cease when a vessel enters her berth and the main engines shut down. There is still the matter of ventilation and other mechanical factors at work to maintain a comfortable, efficient environment. We measured the noise level and vibration displacement in the training ship A-Ra at underway and Berth. The authors analyzed the frequency of noise and maximum vibration displacement in the position.

  • PDF

CONTAM을 이용한 직렬형태 구조의 제연성능 구현에 관한 연구 (Smoke Control Performance of a Serial Structure Using "CONTAM")

  • 김미선;서동길;구선환;유영민;송영주
    • 한국화재소방학회논문지
    • /
    • 제33권6호
    • /
    • pp.53-62
    • /
    • 2019
  • 최근 건축물은 대지 이용의 효율성을 높이기 위해 주상 복합화·고층화되는 추세이며, 이에 따른 화재의 발생빈도 및 잠재적인 위험요소도 증가하고 있다. 특히, 고층 공동주택의 경우 비상용승강기와 별도로 승용승강기 중 1대 이상을 피난용승강기로 설치하게 되어 특별피난계단 부속실, 비상용승강기 승강장 겸용의 경우 피난용승강기 승강장과 직렬형태의 구조가 되어 새로운 형태의 제연구역 이 발생한다. 따라서 비상용승강기 승강장과 피난용승강기 승강장의 직렬형태 구조에 대한 제연구역 선정의 제시가 필요하며, 새로운 형태에서 제연성능을 달성하는 것에 대한 문제가 대두되고 있다. 따라서 본 논문에서는 이러한 문제를 해결하기 위해 CONTAM을 이용하여 각 제연구역 형식(비상용승강기 승강장 단독제연, 피난용승강기 승강장 단독제연, 비상용승강기 승강장과 피난용승강기 승강장 동시제연 누설틈새 적용·미적용)의 방연풍속, 차압을 확인하고, 직렬형태 구조에 대해 제연성능을 확보하기 위한 방안을 제시하고자 한다.

선천성 횡격막 탈장의 지연수술 결과 (The Result of Delayed Operation in Congenital Diaphragmatic Hernia)

  • 이석구;김현학;김경헌;장윤실;박원순
    • Advances in pediatric surgery
    • /
    • 제7권1호
    • /
    • pp.21-25
    • /
    • 2001
  • Congenital diaphragmatic hernia (CDH) in the past was considered a surgical emergency requiring immediate operation. Several groups now advocate preoperative stabilization and delayed surgery. The treatment strategy for CDH in this institution is delayed surgery after preoperative stabilization. The aim of this study was to evaluate the results of delayed surgery. A retrospective review of 16 neonates with CDH was performed. Surfactant. conventional mechanical ventilation. high frequency oscillation. and nitric oxide were utilized for preoperative stabilization as necessary. The difference in outcome between two groups differentiated by the duration of the preoperative stabilization periods with mechanical ventilation (${\leq}$ 8 hours and > 8 hours) was determined. Chi-square test was used to analyze the data. There were 7 right-sided hernias and 9 left. The average duration of stabilization was 32.4 hours. Hepatic herniation through the defect was found in 6 cases and all died. The most common postoperative complication was pneumothorax. The mortality rate of the right side hernia was higher than the left (85.7% vs. 33.3%. p=0.036). Mortality rate of the group (N=8) whose preoperative stabilization period was 8 hours or less was better than that (N=6) whose preoperative stabilization period was more than 8 hours (25.0% vs. 83.3%. p=0.031). The overall mortality rate was 56.3%. The better prognosis was noticed in left side hernia. no liver herniation, or shorter preoperative stabilization period.

  • PDF

PWAM 방식을 이용한 공조시스템용 인버터의 THD 저감 방법 (PWAM Based THD Reduction of Inverter for Air-Conditioning Blower)

  • 임승범;이윤하;전찬용
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.97-98
    • /
    • 2011
  • The HVAC(Heating Ventilation and Air conditioning) system is controlled by two ways, one is ON/OFF control and the other is PWM inverter with V/F. Control of blower with the use of PWM inverter has quite some benefits such as the capability of changing speed, high efficiency and reduced noise level compared with ON/OFF control. But if blower is operated at low speed, high THD generated by decrease of ma, and output voltage lowered in proportion to frequency. To solve these problems, filter should be installed at the output stage of inverter, which can decrease THD but has problems such as increase of volume size and additional braking resistance. This paper proposes the PWAM method which can reduce THD instead of installing the filter at the output stage of inverter. The proposed PWAM method is an inverter modulation method that fixes the modulation index of inverter to reduce THD by varying DC link voltage of inverter unlike conventional PWM method. Finally, the validity of proposed PWAM methods verified by experiments.

  • PDF

해군 함정에서의 EMP 영향 및 대책 (Electromagnetic Pulse Coupling into Naval Warship and Protective Measures)

  • 양진호;남상욱
    • 한국전자파학회논문지
    • /
    • 제25권4호
    • /
    • pp.426-433
    • /
    • 2014
  • 고고도 핵폭발로 인해 고고도 전자기 펄스(HEMP)가 발생한다. 본 논문에서는 Bell 연구소와 IEC 61000-2-9 기준에 제시된 HEMP 파형이 해군 함정의 복사성 결합 통로와 전도성 결합 통로를 통해 입사할 때 침투하는 침투 전계 특성을 비교 검토하였다. 또한, 두 가지 종류의 결합에 대한 효과를 분석하고, 방호 대책을 제시하였다. 시뮬레이션 결과, IEC 61000-2-9 기준이 Bell 연구소의 기준보다 저주파수 대역을 제외하고 침투전계가 크므로 좀 더 엄격한 기준으로 볼 수 있고, 따라서 IEC 61000-2-9의 기준을 해군내 HEMP 기준으로 제시하였다. 최종적으로 HEMP 방호 대책으로 차폐 코팅, 허니컴 통풍구, TVS 소자 등을 이용하여 미국방부 기준에 부합하는 것을 확인하였다.

PIV measurement of oscillatory flow in a micro-channel as a bronchiole model

  • LEE Won-je;KAWAHASHI Massaki;HIRAHARA Hiroyuki
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 Proceedings of 2004 Korea-Japan Joint Seminar on Particle Image Velocimetry
    • /
    • pp.125-134
    • /
    • 2004
  • The improvement of artificial respiration method has brought about the decrease in mortality of pulmonary diseases patients. Various respiratory curative methods, inclusive of HFOV (High Frequency Oscillatory Ventilation), have been developed for more effectual and less harmful management of acute respiratory failure. However, the mechanism of gas transfer and diffusion in a bronchiole has not yet been clarified in detail. As a first approach to the problem, we measured oscillatory flows in a Y-shaped micro-channels as bronchiole model by micro Particle Image Velocimetry(micro PIV). In order to establish the fundamental technique of PIV measurements on oscillatory air flow in a micro-channel, we used about 500-nm-diameter incense smoke particles, a diode laser, a high speed camera including an objective lens, and a HFOV, which is effective technique for medical care of pulmonary disease patients, especially, infants. The bronchiole model size is that parent tube is $500\{mu}m$ width and $500\{mu}m$ depth, and daughter tubes are $450\{mu}m$ width and $500\{mu}m$ depth. From this study made on the phenomenon of fluid in micro size bronchus branch of a lung, we succeeded to get time series velocity distribution in a micro scale bronchial mode. The experimental results of velocity distribution changing with time obtained by micro PIV can give fundamental knowledge on oscillatory airflow in micro-channel.

  • PDF

걷기의 생리학적 분석 - 체력 증진을 위한 운동 - (Physiological Analysis of Walking - Physical Exercise for the Promotion of National Health -)

  • 남기용;장신요;신동훈;성낙응;엄륭의
    • The Korean Journal of Physiology
    • /
    • 제4권1호
    • /
    • pp.1-11
    • /
    • 1970
  • Studies on the analysis of walking were performed on 33 male subjects. A prescription of physical exercise (walking at a speed of greater than 6 km/hr for more than one hour daily) for the promotion of individual health is presented on the basis of walking analysis. Presumptions were made that adequate physical exercise does promote health and is beneficial for the healthy life and increases the life span. These presumptions were derived from the numerous experimental literatures. The literatures support indirectly the presumptions. The following results were obtained and prescription of physical exercise is presented. 1. Oxygen uptake in a walking on a treadmill at a speed of 4 km/hr was only 3 times of the resting oxygen uptake. This kind of moderate exercise did not stimulate the cardiopulmonary system adequately. Heart rate at a 4 km/hr walking was 101 beats/min in boys of less than 20 years old and 83 beats/min in adults. Oxygen uptake at a 6 km/hr walking exceeded 4 times of the resting oxygen uptake. It was interpreted that walking at 6 km/hr stimulated the cardiopulmonary system for the promotion of health. Heart rate at this speed was greater than 110 beats/min in boys and greater than 100 beats/min in adults. 2. Heart rates in a walking of 10 km/hr were 172 beats/min in boys, and 143 beats/min in adults, respectively. Maximal heart rates were 185 beats/min in boys, 180 in office clerks, and 168 beats/min in construction site laboreres. 3. The correlation between heart rate and oxygen uptake was high, namely, r>0.95. Subsequently heart rate could be used as a measure of degree of intensity of physical exercise instead of the cumbersome oxygen uptake measurement. 4. The prescription of physical exercise for the promotion of health is: Daily walking for more than one hour at a speed of greater than 6 km/hr. Bodily functions in this daily walking are in boys (body weight, 50 kg): heart rates of 110 beats/min; breathing frequency, 28/min; oxygen uptake, greater than 4 times of the resting uptake; pulmonary ventilation, 351/min; stride, 124 strides/min; cumulative number of strides for one hour, 7,440 strides, and energy expenditure of more than 300 kcal. In adults (body weight, 60 kg) the bodily functions are: heart rates of 100 beats/min, breathing frequency, 28/min; oxygen uptake, greater than 4 times of the resting uptake; Pulmonary ventilation, 301/min; stride, 127 strides/min; cumulative number of strides for one hour, 7,670 strides, and energy expenditure of more than 300 kcal.

  • PDF

고빈도 환기법 (High Frequency Ventilation)

  • 이현우;이관호
    • Journal of Yeungnam Medical Science
    • /
    • 제10권1호
    • /
    • pp.1-17
    • /
    • 1993
  • 고빈도 환기법은 최근에 개발되어 임상에 응용되면서 호흡생리학, 마취학, 집중치료의 학등의 분야에서 호흡부전의 새로운 치료법으로 관심이 집중되고 있는 환기법이다. 현재까지 고빈도 환기법중 고빈도 양압 환기와 제트 환기는 비교적 많은 연구가 되고 있고 임상적으로 사용되고 있으나 고빈도 진동 환기법은 제한적으로 사용되고 있다. 앞으로 고빈도 진동 환기법에 대해서도 더 많은 연구가 되어야 할 것이다. 또한 최근 개발되고 있는 고빈도 흉벽 진동 환기와 체표면 진동 환기에도 관심을 기울이면 호흡부전 환자의 치료에 바람직한 새로운 환기법이 될 수 있을 것으로 기대된다. 현재 고빈도 환기법의 몇몇 적용형태는 기관지-늑막루등의 폐압손상으로 인한 병변의 치료외에도 기관수술, 흉부수술, 뇌수술에서 수술부위의 움직임을 최소화시키면서 충분한 가스교환율 이룩할 수 있어서 효과적으로 이용되고 있다. 그러나 응급심폐소생술, 폐쇄성 폐질환, 성인 또는 영아 호흡곤란증후군등과 같은 질환에서의 적용은 더 규명되어져야겠다. 고빈도 환기법의 여러가지 문제점중 적절한 환기빈도의 결정, 충분한 습도를 공급하는 장치, 고빈도 환기의 정확한 감시장치의 개발등은 앞으로 우선적으로 해결해야 할 문제점이다. 또한 임상에 더욱 효과적으로 응용될 수 있는 새로운 환기법이 되기 위해서는 고빈도 환기법의 호흡생리와 안정성등에 관한 연구도 병행되어야겠다.

  • PDF

Evaluation of pig behavior changes related to temperature, relative humidity, volatile organic compounds, and illuminance

  • Kim, Yong Ju;Song, Min Ho;Lee, Sang In;Lee, Ji Hwan;Oh, Han Jin;An, Jae Woo;Chang, Se Yeon;Go, Young Bin;Park, Beom Jun;Jo, Min Seok;Lee, Chang Gyu;Kim, Hyeun Bum;Cho, Jin Ho
    • Journal of Animal Science and Technology
    • /
    • 제63권4호
    • /
    • pp.790-798
    • /
    • 2021
  • The objective of this study was evaluation of pig behavior changes related to temperature, relative humidity, volatile organic compounds (VOCs), and illuminance. A total of 24 growing pigs ([Yorkshire × Landrace] × Duroc) were used in the experiment. A sensor was installed at a height of 0.5 m in the center of the pig house. In experiment 1, temperature was changed every four days to 18℃ (T1), 22℃ (T2), 26℃ (T3), and then 30℃ (T4). In experiment 2, relative humidity was adjusted to 45% (low humidity [LH]), 60% (middle humidity [MH]), and then 75% (high humidity [HH]) for four days. In experiment 3, after cleaning the pig house just before experiment, only minimal ventilation was provided. VOCs and pig behaviors were observed for 7 days without cleaning the pig house. In experiment 4, three light bulbs of 40 W (470 lumens / 45 lx; low illuminance [LI]), 75 W (1,055 lumens / 103 lx; middle illuminance [MI]), and 100 W (1,521 lumens / 146 lx; high illuminance [HI]) were used for four days each. Pig behavior analysis was performed for following criteria : Feed intake, Standing, Lying, Sitting, Drink water, Rooting, Posture transition (lying-standing), Posture transition (standing-lying), Wallowing, and Biting. In experiment 1, feed intake time was lower (p < 0.05) for the T3 than other treatment groups. Standing time was highest (p < 0.05) for the T1 and lowest (p < 0.05) for the T3. Lying time was shorter (p < 0.05) in T1 and T2 compared to T3 and T4. Drinking frequency was higher (p < 0.05) for the T4 than other treatment groups. In experiment 2, the frequency of rooting and wallowing increased (p < 0.05) with increasing humidity. LH showed the lowest (p < 0.05) rooting frequency and HH showed the highest (p < 0.05) rooting frequency. In experiment 3, VOCs concentration did not (p > 0.05) change pig behavior. In experiment 4, lying time was the longest (p < 0.05) at LI and shortest (p < 0.05) at HI. Therefore, pig behavior is heavily influenced by the environment, especially temperature and humidity. However, correlation between pig behavior to VOCs and illuminance seems to be needed more research.

만성 폐쇄성 폐질환에서 기관의 단면적과 폐기능지표와의 상관관계 (Correlation of Tracheal Cross-sectional Area with Parameters of Pulmonary Function in COPD)

  • 이찬주;이재호;송재우;유철규;김영환;한성구;심영수;정희순
    • Tuberculosis and Respiratory Diseases
    • /
    • 제46권5호
    • /
    • pp.628-635
    • /
    • 1999
  • 연구배경 : 만성 폐쇄성 폐질환을 대변하는 폐기종에서 주요 기능적 장애는 호기의 장애이며, 최대 호기류량은 기도의 크기, 폐의 탄력반동압 그리고 기도의 함몰성에 의해 결정된다. 기도의 항몰성은 폐기종에서 기류를 제한하는 하나의 기전으로 작용하지만, 폐용적과 폐의 과팽창을 유지하는 기전으로 작용하여 가스교환을 증진시킨다는 주장도 있다. 따라서 폐기종에서 기관이 호흡에 미치는 생리학적 역할이 무엇인지를 알아보고자 본 연구를 수행하였다. 방 법 : 1997년 1월 1일부터 8월 31일까지 보라매병원 호흡기내과를 방문하여 단순 흉부방사선검사, 체간용적기록계(body plethysmography)를 포함하는 폐기능검사 및 HRCT를 통해 폐기종으로 진단된 20명을 대상으로 하였다. HRCT에서 대동맥궁의 정상부위에서 기관의 단면적을 호흡주기에 따라 측정하고 이를 체표면적으로 보정한 값과 동맥혈의 이산화탄소분압 및 산소분압, 기도저항, 폐유순도 등 폐기능지표와의 상관 관계를 분석하였다. 결 과 : 폐기종에서 기관의 단면적은 호기시 동맥혈의 이산화탄소분압(r=-0.61, p<0.05) 및 산소분압(r=0.6, p<0.05) 그리고 매분환기량(r=0.73, p<0.05)과 유의한 상관관계가 있었지만, 흡기시에는 상관관계가 없었다(이산화탄소분압과는 r=-0.22, p>0.05, 산소분압과는 r=0.26, p>0.05, 매분환기량과는 r=0.44, p>0.05). 매분환기량은 상시호흡량(tidal volume)과는 r=0.45(p<0.05)로 유의한 상관관계가 있었지만, 호흡수와는 r=-0.31(p>0.05)로 상관관계가 없었다. 폐기종에서 기관의 단면적은 호흡주기와 상관없이 $FEV_1$ FVC, $FEV_1$/FEC, 최대 호기류량, 잔기용적, 폐확산능, 기도저항, 폐유순도 등의 다른 폐기능지표와는 상관관계가 없었다. 결 론 : 폐기종에서 호기시 기관의 단면적은 주로 가스 교환(gas exchange)의 지표들과 유의한 상관관계가 있었지만, 폐용적이나 폐의 과팽창을 시사하는 지표와는 상관관계가 없었다. 따라서 폐기종에서는 호기시 동일 압력점의 개념에 의해 발생하는 기도압박으로 기관의 단면적이 감소하고 이러한 현상이 기류를 제한하는 하나의 기전으로 작용하는 것이지 폐용적이나 폐의 과팽창을 유지시켜 가스교환을 증진시키는 것은 아니라고 생각된다.

  • PDF