• Title/Summary/Keyword: High-Frequency Medical Device

Search Result 56, Processing Time 0.025 seconds

Comparison of high-resolution and standard zoom imaging modes in cone beam computed tomography for detection of longitudinal root fracture: An in vitro study

  • Taramsari, Mehran;Kajan, Zahra Dalili;Bashirzadeh, Parinaz;Salamat, Fatemeh
    • Imaging Science in Dentistry
    • /
    • v.43 no.3
    • /
    • pp.171-177
    • /
    • 2013
  • Purpose: The purpose of this study was to compare the efficacy of two imaging modes in a cone beam computed tomography (CBCT) system in detecting root fracture in endodontically-treated teeth with fiber posts or screw posts by selecting two fields of view. Materials and Methods: In this study, 78 endodontically-treated single canal premolars were included. A post space was created in all of them. Then the teeth were randomly set in one of 6 artificial dental arches. In 39 of the 78 teeth set in the 6 dental arches, a root fracture was intentionally created. Next, a fiber post and a screw post were cemented into 26 teeth having equal the root fractures. High resolution (HiRes) and standard zoom images were provided by a CBCT device. Upon considering the reconstructed images, two observers in agreement with each other confirmed the presence or absence of root fracture. A McNemar test was used for comparing the results of the two modes. Results: The frequency of making a correct diagnosis using the HiRes zoom imaging mode was 71.8% and in standard zoom was 59%. The overall sensitivity and specificity in diagnosing root fracture in the HiRes mode were 71.79% and 46.15% and in the standard zoom modes were 58.97% and 33.33%, respectively. Conclusion: There were no significant differences between the diagnostic values of the two imaging modes used in the diagnosis of root fracture or in the presence of root canal restorations. In both modes, the most true-positive results were reported in the post space group.

Ultrasonography in periodontal diagnosis (악안면 초음파의 치주학적 활용)

  • Kim, Dae-Yeob;Lee, Jong-Bin;Pang, Eun-Kyoung
    • The Journal of the Korean dental association
    • /
    • v.55 no.11
    • /
    • pp.800-807
    • /
    • 2017
  • Ultrasonography is one of the most common diagnostic tools in medical imaging with non-invasive and non-radiation loaded characteristics. In the field of dentistry, especially for periodontology, high frequency ultrasonic device can be used for several purposes such as evaluating gingival thickness, identifying the level of alveolar bone, measuring the volume of mucosa of donor site for soft tissue graft and so on. According to recent studies, it was demonstrated that ultrasonic diagnosis had both accuracy and repeatability comparable to conventional diagnostic tools. However, improvement and development of intra-oral probe suitable for adpatation to gingiva and palatal mucosa, are considered as prerequisites for diffusion of ultrasonic diagnosis in periodontology.

  • PDF

A Study on Hospitalized Patients' Intent to Use Home Care Nursing According to the Types of Medical Security (입원환자의 의료보장형태에 따른 가정간호 이용의사에 대한 연구)

  • Kim, Myung-Hee;Cho, Eun-Ji;Park, Hyoung-Sook;Kang, In-Soon
    • Journal of Korean Academic Society of Home Health Care Nursing
    • /
    • v.12 no.2
    • /
    • pp.63-86
    • /
    • 2005
  • Purpose: This study is a descriptive research which is designed to investigate hospitalized patients' intent to use home care nursing according to the types of medical security. Method: This researcher surveyed 236 patients who were hospitalized at B medical center located in Busan,. Data were collected from Sep. 1 to Nov. 30, 2005 using a questionnaire survey, medical records, face-to-face interviews and observations. Collected data were analyzed in terms of frequency, percentage, mean and standard deviation through $x^2$-test and t-test under SPSS WIN 10.0 Program. Result: Out of the total subjects, 59.3% were medical aid clients and the remaining 40.7%, health insurance ones. The hospitalized period and frequency of the former group were 38.0 days and 4.0 times, respectively, while those of the latter, 37.7 and 3.4. When home care nursing clients were examined using a given classification device, it was found that out of the total 236 subjects, 205(86.9%) were needed to receive home care nursing, 121, medical aid and the other 84, health insurance. 24.0% of medical aid clients heard about home care nursing ever before, lower than 39.3% of health insurance clients. 43.8% of the former clients said cost for home care nursing was high while, 47.6% of the latter group responded expense for the nursing intervention was low. 30.6% of medical aid clients had intent to use home care nursing, lower than 47.6% of health insurance clients. 71.7% of those patients whose monthly income was 99 million won or below had no intent to use home care nursing, higher than 62.5% of those who were 100 million or over in monthly income(p<.05). 76.4% of those clients who had no nursing provider intented to use home care nursing, higher than those who had nursing provider(p<.05). Concerning contents of home care nursing, 85.1% of medical aid clients needed education, training and counseling while, 77.4% of health insurance aids wanted medication and injection. Conclusion: In conclusion, the use of home care nursing by medical aid clients should be promoted through improving conditions for home care nursing in terms of expense, family and residence and making public relations about activities and contents of the home care nursing.

  • PDF

Analysis of Characteristic of Wound Therapy Apparatus using ${\mu}$-Controller (마이크로컨트롤러를 이용한 창상 치유기의 특성 평가)

  • Cheon, Min-Woo;Kim, Seong-Hwan;Park, Yong-Pil;Lee, Ho-Sik;Kim, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.497-497
    • /
    • 2007
  • We developed the light medical therapy apparatus for external injury cure using a ${\mu}$-controller. This equipment was fabricated by using a high brightness LEDs and a ATmega 128, and designed to enable us to control irradiation timer, intensity and reservation. Especially, to control the light irradiation frequency, and to control the change of output value, TLC5941 was used. Control stage is divided into 4 step by program. Consequently, the current value could be controlled by the change of level in Continue Wave(CW) and the output of a high brightness LEDs could be controlled, stage by stage. In this paper, the designed device was used to find out how a high brightness LEDs light source affects the skin wound of a small animal. In result, compared with none light irradiation animal, the lower incidence of inflammation and faster recovery was shown in light irradiation animal.

  • PDF

Special quality research about action output waveform change by gap (1.0mm and 1.6mm) difference of $CO_2$ laser for skin disease (피부질환을 위한 $CO_2$ 레이저의 공극 (1.0mm 및 1.6mm)차이에 따른 동작출력 파형변화에 관한 특성연구)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.156-158
    • /
    • 2007
  • Laser wave length can have evaporation effect by absorption because outer skin or tissue of focus is consisted of water almost though absorption of water occurs more than 90% almost in formation thickness of very thin floor Can operate outer skin, steam by floor and correct incision of formation is available. Suture surgical operation is avaliable to vein or lymph system and surgical operation region can dry and see as eye and radish bleeding surgical operation is avaliable Specially, stability of tube both end output about pulse by weight very, this research can cause various curative effect because can reduce bulk and control easily current wave style of medical laser using electric power conversion device of high frequency way. If introduce ZVS (Zero Voltage Switching) or ZVZCS (Zero Voltage and Zero Current Switching), is more profitable because can reduce switching damage Because electric power department of proposed medical laser can do stable soft-switching in wide subordinate extent introducing ZVZCS technique by the first help and control department composes microcontroller, output current waveform user have free form make. Result that experiment because design and manufacture, brought result that improve of 20% than existing equipment, and will be bought to get into superior result if supplement as systematic late.

  • PDF

Special quality research about action output waveform change by gap (1.0mm and 1.6mm) difference of $CO_2$ laser for skin disease (피부질환을 위한 $CO_2$ 레이저의 공극차이에 따른 동작출력 변화에 관한 연구)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.52-54
    • /
    • 2007
  • Laser wave length can have evaporation effect by absorption because outer skin or tissue of focus is consisted of water almost though absorption of water occurs more than 90% almost in formation thickness of very thin floor. Can operate outer skin, steam by floor and correct incision of formation is available. Suture surgical operation is available to vein or lymph system and surgical operation region can dry and see as eye and radish bleeding surgical operation is available. Specially, stability of tube both end output about pulse by weight very, this research can cause various curative effect because can reduce bulk and control easily current wave style of medical laser using electric power conversion device of high frequency way. If introduce ZVS (Zero Voltage Switching) or ZVZCS (Zero Voltage and Zero Current Switching), is more profitable because can reduce switching damage. Because electric power department of proposed medical laser can do stable soft-switching in wide subordinate extent introducing ZVZCS technique by the first help and control department composes microcontroller, output current waveform user have free form make. Result that experiment because design and manufacture, brought result that improve of 20% than existing equipment, and will be bought to get into superior result if supplement as systematic late.

  • PDF

Recent research trends on Bio-MEMS (Bio-MEMS분야의 최근 연구동향)

  • Park, Se-Kwang;Yang, Joo-Ran
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.259-270
    • /
    • 2010
  • MEMS(micro electro mechanical systems) is a technology for the manufacture hyperfine structure, as a micro-sensor and a driving device, by a variety of materials such as silicon and polymer. Many study for utilizing the MEMS applications have been performed in variety of fields, such as light devices, high frequency equipments, bio-technology, energy applications and other applications. Especially, the field of Bio-MEMS related with bio-technology is very attractive, because it have the potential technology for the miniaturization of the medical diagnosis system. Bio-MEMS, the compound word formed from the words 'Bio-technology' and 'MEMS', is hyperfine devices to analyze biological signals in vitro or in vivo. It is extending the range of its application area, by combination with nano-technology(NT), Information Technology(IT). The LOC(lab-on-a-chip) in Bio-MEMS, the comprehensive measurement system combined with Micro fluidic systems, bio-sensors and bio-materials, is the representative technology for the miniaturization of the medical diagnosis system. Therefore, many researchers around the world are performing research on this area. In this paper, the application, development and market trends of Bio-MEMS are investigated.

A study on Actual Condition and Interfererence of Electromagnetic Fields inside of The Hospital (I) (의료기관내 전자파환경 실태와 그 영향 (I))

  • Lee, Jun-Ha;Shin, Hyun-Jin;Yoo, Heum
    • Progress in Medical Physics
    • /
    • v.8 no.1
    • /
    • pp.53-67
    • /
    • 1997
  • General hospitals have being under the influence of various and specific environment of electromagnetic field. The factors are development of medical electric equipment and device with enlarged functional demands, in high power and multi-frequency. It has all of both faces, EMI(electromagnetic interference) and EMS(electromagnetic susceptibility). In additional, expansion of personal communication system(cellular phone) has many unreliable factor of using time and area, making noise of electromagnetic fields. We studied actual conditions of EMI in the medical site, where is numerous medical equipment, especially central operation room and ICU(intensive care unit), AKR(artificial kidney room : hemo-dialysis unit), etc. The influence, most of medical equipments made electromagnetic nosie has various factors in its band of frequency, harmonics and strength. In the experimental use of electro-surgical unit and cellular phone, noticeable and considerable noise of eletromagnetic fields were measured. All of that can make trouble and errors on the steadiness of bioelectrical devices. In conclusion, It is necessary to reconsiderations of reallocating EMI source vs. EMS factor, and set to definite forbiding area of using cellular phone. For maintenance of steady normal conditions, in spite of existing any other legal standards of safty level, it need considering all of alternative electromagnetic situations on a case-by-case basis.

  • PDF

A Study on Safety Management Inspection of Diagnostic X-ray System (진단용 엑스선 장치의 안전관리 검사에 관한 연구)

  • Lee, Hoo min;Kim, Hyeon ju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.887-893
    • /
    • 2018
  • The purpose of this study is to compare the performance of X-ray generators installed in hospitals and universities and apply the quality control items of diagnostic X-ray generators to recognize the importance of periodic performance management. First, the reproducibility and linearity test results showed that the PAE of the reproducibility evaluation was high for the GX-650 devices that met the acceptance criteria in all the experimental conditions and lacked the periodic quality control. In the linearity evaluation, when the tube voltage was set to 100 kVp, It was measured to deviate from the error. In addition, it was found that the PAE in the low-accuracy evaluation results relative to an X-ray tube voltage and tube current of the device low occurrence frequency. The HVL experiment was included in all of the devices at the HVL by tube voltage. Therefore, it is necessary to recognize the importance of quality control of all devices rather than hospital and laboratory, and to manage the device performance by actively managing the device, and to establish a short - term quality control system like special medical devices.

Case Study Of Hair Growth Effect of The Hair Scalpdetox Five Step Program (두피해독 5단계 프로그램의 발모효과 사례 연구)

  • Jeong, Keum-Yong;Tak, Sang-Sook;Kim, Ju-Hee;Park, Jeong-Yong;Hong, Kweon-Eui;Ju, Mi-Sook
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.29 no.3
    • /
    • pp.259-273
    • /
    • 2016
  • Objectives: Objectives of this research is to test hair growth effect of the hair scalpdetox five step program.Methods : Data for this research is gathered from participants who are suffering from hair loss and have completed scalpdetox five step program at a esthetic by receiving treatments twenty times constantly with once or twice a week during three months from March 2015 to April 2016. The hair scalpdetox program consists of five steps : the first step is shampooing, the second is scalp massage with aroma oils, the third is vertical meridian scrapping massage, the fourth is applying scalp and hair pack made with natural herbs, and the last is scalp massage with an indirect high frequency massaging device.Results: Subjective evaluations from the participants show that overall hair scalp conditions are meaningfully improved. Participants evaluated that tested approach helps hair growth by increasing the number of hair (p<.01) and helps to make their hair thicker (p<.01). Visual observations with magnification by 60 times and 200 times show improvement in hair scalp condition and clean opening of pores. Photographs of hair loss parts of each participant also show improvement in hair growth.Conclusions: From the evaluation of the participants for the test program and from visual observations, we conclude that suggested hair scalpdetox five step program has effect on improving scalp, hair condition, and hair growth.