• 제목/요약/키워드: High- and low-dose-rate

검색결과 284건 처리시간 0.031초

Hormesis as a Confounding Factor in Epidemiological Studies of Radiation Carcinogenesis

  • Sanders Charles L.
    • Journal of Radiation Protection and Research
    • /
    • 제31권2호
    • /
    • pp.69-89
    • /
    • 2006
  • Biological mechanisms for ionizing radiation effects are different at low doses than at high doses. Radiation hormesis involves low-dose-induced protection and high-dose-induced harm. The protective component is associated with a reduction in the incidence of cancer below the spontaneous frequency, brought about by activation of defensive and repair processes. The Linear No-Threshold (LNT) hypothesis advocated by the International Commission on Radiological Protection (ICRP) and the Biological Effects of ionizing Radiation (BEIR) Report VII for cancer risk estimations Ignores hormesis and the presence of a threshold. Cancer incidences significantly less than expected have been found in a large number of epidemiological studies including, airline flight personnel, inhabitants of high radiation backgrounds, shipyard workers, nuclear site workers in scores of locations throughout the world, nuclear power utility workers, plutonium workers, military nuclear test site Participants, Japanese A-bomb survivors, residents contaminated by major nuclear accidents, residents of Taiwan living in $^{60}Co$ contaminated buildings, fluoroscopy and mammography patients, radium dial painters, and those exposed to indoor radon. Significantly increased cancer was not found at doses <200 $mSv^*$. Evidence for radiation hormesis was seen in both sexes for acute or chronic exposures, low or high LET radiations, external whole- or partial body exposures, and for internal radionuclides. The ubiquitous nature of the Healthy Worker Effect (HWE)-like responses in cellular, animal and epidemiological studies negates the HWE as an explanation for radiation hormesis. The LNT hypothesis is wrong and does not represent the true nature of the dose-response relationship, since low doses or dose-rates commonly result in thresholds and reduce cancer incidences below the spontaneous rate. Radiation protection organizations should seriously consider the cost and health implications of radiation hormesis.

면역방사계수측정법의 민감도 향상을 위한 변법의 평가 (Evaluation of Variation Method to Improve the Sensitivity of Immunoradiometric Assay)

  • 권원현;강미지;김나경;박지솔;김정인;이경재
    • 핵의학기술
    • /
    • 제27권1호
    • /
    • pp.29-35
    • /
    • 2023
  • Purpose The concentration of PSA (Prostate Specific Antigen) after radical prostatectomy in prostate cancer patients is a predictor of biochemical recurrence, and the AUA (American Urological Association) is defined as biochemical recurrence when the concentration of PSA is measured at 0.2 ng/mL or more, and when the concentration is measured at 0.2 ng/mL or more at the retest. This standard is also applied our hospital. In this laboratory, the PSA reagent using IRMA (Immunoradiometric Assay) is used, and the sensitivity at a very low value was not as good as the reagent used in the department of laboratory medicine. This study aims to increase the reliability of the results by improving the precision and sensitivity of very low values. Materials and Methods As a reagent for the study, PSA reagent using IRMA was used. As a method to improve the precision and sensitivity of very low values, a variation method on the serum volume(25 uL, 50 uL, 100 uL, 200 uL) was studied, and variation usefulness evaluation was conducted. The evaluation items were compared the results of precision, analytical sensitivity, recovery rate, dilution test, high-dose hook effect test, parallel test and very low concentration values(n = 20). Results The validation results were displayed in the order of 25 uL, 50 uL, 100 uL, 200 uL. As the serum volume increased, it was confirmed that CV (Coefficient of Variation)(%) improved. Analytical sensitivity(ng/mL) was 0.038, 0.041, 0.017, 0.015 and recovery rate(%) was 101±3, 101±3, 99±2, 97±4. very low concentration values(ng/mL) between each volume(n=20) were 0.135±0.068, 0.076±0.050, 0.048±0.034, 0.046±0.034. and high dose hook effect appeared as the serum volume increased. Conclusion Through the variation usefulness evaluation, it was confirmed that as the serum volume increased, the precision and sensitivity improved at very low concentration values. However, it is necessary to pay special attention to the occurrence of high-dose hook effect as the serum volume increases. In the case of tests that requires very low concentration values, it is thought that the reliability of the result will be increased if the variation method is properly used after the variation usefulness evaluation.

  • PDF

자궁경부암용 팬톰을 이용한 HDR (High dose rate) 근접치료의 선량 평가 (Dose Verification Using Pelvic Phantom in High Dose Rate (HDR) Brachytherapy)

  • 장지나;허순녕;김회남;윤세철;최보영;이형구;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제14권1호
    • /
    • pp.15-19
    • /
    • 2003
  • HDR (High dose rate) 근접 치료는 기존의 LDR (Low dose rate) 근접 치료에서 야기되었던 치료 시간이나 선량 최적화 등의 문제점을 해결하였기 때문에 자궁경부암 치료에 많이 사용되고 있다. 그러나, 단시간에 고선량이 조사되는 HDR 근접치료에서 치료 효과를 극대화시키기 위해서는 선량 계산 알고리즘, 위치 계산 알고리즘, 최적화 알고리즘이 정확하게 검증되어야 한다. 이를 위해서는 인체 등가 팬톰과 치료 계획 컴퓨터의 선량 분포 곡선을 비교함으로써 검증할 수 있다. 본 연구에서는 이러한 검증이 가능하도록 자궁경부암용 팬톰을 설계, 제작하여 HDR 치료 계획 컴퓨터와 팬톰과의 선량을 비교, 평가하는 것이다 이 자궁경부암용 팬톰은 높은 해상도를 가진 선량 측정기를 사용하여 정량적인 평가가 가능하도록 제작되었고, 인체 등가물질인 물과 아크릴을 사용하여 제작하였다 또한, 팬톰 내의 방사선량 측정을 위해서 $\frac{1}{8}$ 인치 TLD (Thermoluminescent dosimeters) 칩과 공간 해상도가 1 mm 이내인 필름을 사용하였다. 이 자궁경부암용 팬톰는 HDR applicator의 고정을 위해 applicator 홀더의 홈 안에 HDR applicator가 삽입되게 제작하였고 세 개의 TLD 홀더에는 TLD 칩(TLD 간의 거리는 5 mm)이 정렬되게 제작하여 A점이나 B점 같은 특정 점의 절대 선량을 측정할 수 있게 제작하였다 필름은 3개의 직교(orthogonal) 평면에 삽입되도록 제작하여 상대 선량 측정이 가능하게 하였다. 사용된 치료 계획 시스템은 Nucletron Plato system이고, Microselectron Ir-192 소스를 사용하였다. 선량 평가 결과, TLD 선량의 경우 A, B point를 포함하여 직장과 방광 선량이 $\pm$4% 이내로 치료계획 컴퓨터(Plato, Nucletron)와 일치하였고, 필름의 경우 선량 분포 곡선이 치료계획 컴퓨터의 선량 분포 곡선 패턴과 거의 일치하는 우수한 결과를 보였다. 제작된 자궁경부암용 팬톰은 HDR 치료 계획 컴퓨터의 선량 계산 알고리즘의 평가 및 검증에 유용하게 사용될 것이고, 이 팬톰은 강남성모병원 치료방사선과 HDR 근접치료 기기의 선량과 위치확인의 QA(quality assurance) 도구로써 사용하려고 추진 중에 있다.

  • PDF

고선량율 근접 방사선치료법을 이용한 원발성 및 재발된 설암의 치료 (HIGH DOSE RATE BRACHYTHERAPY IN PRIMARY AND RECURRENT TONGUE CANCER)

  • 이의룡;이종호;정필훈;김명진;박주용;최성원;조관호
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제28권5호
    • /
    • pp.470-476
    • /
    • 2006
  • Low-dose rate brachytherapy(LDR) has been effective modality for treatment of oral cancer. But the disadvantage of LDR is radioexposure of medical staff. To overcome this problem, high dose rate(HDR) brachytherapy has been developed. Our study evaluates the outcomes of patients with tongue cancer as treated by HDR brachytherapy. Between 2002 and 2005, eight patients with carcinoma of the tongue were treated with HDR brachytherapy. Five patients had AJCC stage I or II disease and the remaining three patients had AJCC stage III or IV. The male-to-female ratio was 2:6 and the mean age was 60.1 years (range: 21-80 years).The median follow-up time was 23.8 months (range: 7-55 months). There was no local failure until now. Three patients showed some complications. Two patients showed soft tissue necrosis. There was no bone sequela in all cases. Our experience in treating tongue cancer with HDR brachytherapy is encouraging, because it gave a satisfactory local control. Prospective studies are necessary to delineate the optimum indication for this treatment modality and long-term outcome.

PET/CT실에서 사용되는 주사기 차폐체의 산란선 측정 (Scattering Measurement of Syringe Shield Used in PET/CT)

  • 장동근;박철우;박은태
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권5호
    • /
    • pp.375-382
    • /
    • 2020
  • PET/CT is a medical equipment that detects 0.511 MeV of gamma rays. The radiation workers are inevitably exposed to ionizing radiation in the process of handling the isotope. Accordingly, PET/CT workers use syringe shields made of lead and tungsten to protect their hands. However, lead and tungsten are known to generate very high scattering particles by interacting with gamma rays. Therefore, in this study, we tried to find out the effect on the scattering particles emitted from the syringe shield. In the experiment, first, the exposure dose to the hand (Rod phantom) was evaluated according to the metal material (lead, tungsten, iron, stainless steel) using Monte Carlo simulation. The exposure dose was compared according to whether or not plastic is attached. Second, the exposure dose of scattering particles was measured using a dosimeter and lead. As a result of the experiment, the shielding rate of plastics using the Monte Carlo simulation showed the largest difference in dose of about 40 % in lead, and the lowest in iron, about 15 %. As a result of the dosimeter test, when the plastic tape was wound on lead, it was found that the reduction rate was about 15 %, 28 %, and 39 % depending on the thickness. Based on the above results, it was found that 0.511 MeV of gamma ray interacts with the shielding tool to emit scattered rays and has a very large effect on radiation exposure. However, it was considered that the scattering particles could be sufficiently removed with plastics with a low atomic number. From now on, when using high-energy radiation, the shielding tool and the skin should not be in direct contact, and should be covered with a material with a low atomic number.

Mongolian Gerbil의 뇌허혈 유발에 따른 뇌조직 손상에 있어서 사향 함유 우황청심원액과 영묘향 함유 우황청심원액의 조직학적 효능 비교 (The comparison of histological effects of musk containing and civet containing WooHwangChungSimWon on the cerebral ischemia)

  • 최은욱;이장헌;신상덕;마응천
    • Biomolecules & Therapeutics
    • /
    • 제8권3호
    • /
    • pp.255-261
    • /
    • 2000
  • WooHwangChungSimWon is a traditional prescription for treating with hypertension, arteriosclerosis, coma, and stroke in China, Korea, and Japan. In the new presciption of WooHwangChungSimWon, the covet is substituted for the musk, the major component of WooHwangChungSimwon, because of the prohibition law about the musk. We have made a comparative study of the effects on the ischemic damage between the musk containing and civet containing WooHwangChungSimWon. In order to investigate the effects of WooHwangChungSimWon on the ischemic damage, each samples were administrated for 12 days, ischemia was induced for 10 minutes at 7th day, and immunohistochemistry was performed in the region of hippocampus of mongolian gerbils. According to the result of immunohistochemistry, the survival rates of neuroal cells in the hippocampal CA1 region are 37.8% in the high dose of musk containing WooHwangChungSimWon (HM-WHCSW) administrated group, 27.8% in low dose of civet containing WooHwangChungSimWon (LC-WHCSW), and 35.5% in high dose of civet containing WooHwangChungSimWon (HC-WHCSW) administrated group. These survial rates were significantly different from the survival rate of sham control group (14.4%). The results suggest that all the samples except the low dose of musk containing WooHwangChungSimWon (LM-WHCSW) have protective or preventive effects on cerebral ischemia.

  • PDF

3D 프린팅 플라스틱 섬광체의 양성자 빔에 대한 적용 (Preliminary Test of 3D Printed Plastic Scintillators for Proton Beam)

  • 김성환
    • 한국방사선학회논문지
    • /
    • 제16권6호
    • /
    • pp.681-686
    • /
    • 2022
  • 본 연구에서 상용 아크릴 기반 레진에 PPO 유기섬광체 및 MMA를 각각 1 wt% 및 5 wt% 첨가하여 3D 프린팅이 가능한 섬광체 레진을 제작하였다. 개발된 섬광체 레진을 사용하여 상용 3D DLP로 간편하면서도 저렴하게 3D 모양의 플라스틱 섬광체 방사선 센서를 성공적으로 제작할 수 있었다. 제작된 센서는 45 MeV 양성자 빔의 빔 전류 1 ~ 10 nA 범위에서 R제곱값이 0.998로 우수한 선량 대 출력 직선성을 보였다. 개발된 3D 플라스틱 섬광체는 광출력이 낮아서 저선량율 감마선이나 X선 선량 측정에 활용하기에는 제한이 있지만, 조직등가물질로서 인체흡수선량을 직접 측정할 수 있기 때문에 양성자 빔, 초고선량율 빔 등 고에너지 또는 고선량율 방사선 선량 측정에 유용하게 활용될 수 있음을 확인하였다.

Maternal caffeine consumption has irreversible effects on reproductive parameters and fertility in male offspring rats

  • Dorostghoal, Mehran;Majd, Naeem Erfani;Nooraei, Parvaneh
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제39권4호
    • /
    • pp.144-152
    • /
    • 2012
  • Objective: Concerns are growing about the decrease in male reproductive health. Caffeine is one of the popular nutrients that has been implicated as a risk factor for infertility. In the present study, we examined whether in utero and lactational exposure to caffeine affects the reproductive function of the offspring of rats. Methods: Pregnant rats received caffeine via drinking water during gestation (26 and 45 mg/kg) and lactation (25 and 35 mg/kg). Body and reproductive organ weight, seminiferous tubule diameter, germinal epithelium height, sperm parameters, fertility rate, number of implantations, and testosterone level of the offspring were assessed from birth to adulthood. Results: Significant dose-related decreases were observed in the body and reproductive organ weight, seminiferous tubule diameter, and germinal epithelium height of the offspring. Sperm density had declined significantly in offspring of the low-dose and high-dose groups, by 8.81% and 19.97%, respectively, by postnatal day 150. The number of viable fetuses had decreased significantly in females mated with male offspring of the high-dose group at postnatal days 60, 90, 120, and 150. There were also significant reductions in testosterone levels of high-dose group offspring from birth to postnatal day 150. Conclusion: It is concluded that maternal caffeine consumption impairs gonadal development and has long-term adverse effects on the reproductive efficiency of male offspring rats.

DIFFERENTIAL EXPRESSION OF RADIATION RESPONSE GENES IN SPLEEN, LUNG, AND LIVER OF RATS FOLLOWING ACUTE OR CHRONIC RADIATION EXPOSURE

  • Jin, Hee;Jin, Yeung Bae;Lee, Ju-Woon;Kim, Jae-Kyung;Lee, Yun-Sil
    • Journal of Radiation Protection and Research
    • /
    • 제40권1호
    • /
    • pp.25-35
    • /
    • 2015
  • We analyzed the differential effects of histopathology, apoptosis and expression of radiation response genes after chronic low dose rate (LDR) and acute high dose rate (HDR) radiation exposure in spleen, lung and liver of rats. Female 6-week-old Sprague-Dawley rats were used. For chronic low-dose whole body irradiation, rats were maintained for 14 days in a $^{60}Co$ gamma ray irradiated room and received a cumulative dose of 2 Gy or 5 Gy. Rats in the acute whole body exposure group were exposed to an equal dose of radiation delivered as a single pulse ($^{137}Cs$-gamma). At 24 hours after exposure, spleen, lung and liver tissues were extracted for histopathologic examination, western blotting and RT-PCR analysis. 1. The spleen showed the most dramatic differential response to acute and chronic exposure, with the induction of substantial tissue damage by HDR but not by LDR radiation. Effects of LDR radiation on the lung were only apparent at the higher dose (5 Gy), but not at lower dose (2 Gy). In the liver, HDR and LDR exposure induced a similar damage response at both doses. RT-PCR analysis identified cyclin G1 as a LDR-responsive gene in the spleen of rats exposed to 2 Gy and 5 Gy gamma radiation and in the lung of animals irradiated with 5 Gy. 2. The effects of LDR radiation differed among lung, liver, and spleen tissues. The spleen showed the greatest differential effect between HDR and LDR. The response to LDR radiation may involve expression of cyclin G1.

Gamma Knife Radiosurgery for Trigeminal Neuralgia : Review and Update

  • Lee, Seunghoon;Lee, Jung-Il
    • Journal of Korean Neurosurgical Society
    • /
    • 제65권5호
    • /
    • pp.633-639
    • /
    • 2022
  • Accurate diagnosis of trigeminal neuralgia (TN) is the starting point for optimal treatment. Gamma knife radiosurgery (GKRS) is currently regarded as one of the first-line treatment options for medically refractory TN. GKRS is a less invasive treatment with a low risk of complications than other surgical procedures that provides a favorable pain control Barrow Neurological Institute (BNI) I-IIIb rate of >75% at short-term follow-up. Drawbacks of GKRS include the latency period before pain relief and higher recurrence rate compared with microvascular decompression. Therefore, repeat treatment is necessary if the initial GKRS was effective but followed by recurrence. The concept of dose rate and the biologically effective dose of radiation has been actively studied in radiation oncology and is also applied in GKRS for TN to achieve high safety and efficacy by prescribing the optimal dose. Recent progress in functional imaging, such as diffusion tensor imaging, enables us to understand the pathophysiology of TN and predict the clinical outcome after GKRS. Here, we review TN, GKRS, and recent updates, especially in the concepts of radiation dose, diffusion tensor imaging studies, and repeat treatment in GKRS for TN.