• Title/Summary/Keyword: High windows

Search Result 723, Processing Time 0.031 seconds

A Study on the Development of Automatic Drawing System for Pump (펌프의 자동설계 시스템 개발에 관한 연구)

  • Kim, Ill-Soo;Park, Chang-Eun;Jeong, Young-Jae;Song, Chang-Jae;Kim, Hak-Hyoung;Park, Ju-Seog
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.333-337
    • /
    • 1999
  • The biggest challenge facing today manufacturing industry is better quality and high productivity. From an economic point of view, productivity is the most important parameter, as high productivity will reduce the cost. However, the customers of day are not only cost concerned, but also quality conscious. So high accuracy levels should also be achieved in the manufacturing process. This paper reports the development of a automatic design system based on AutoCAD program. 1'his work is composed of three section that are design of top down menu, impeller and casing for pump programed by AutoLISP language and runned Windows system. The developed system ultimately generates the design for a pump through AutoCAD program. In the design of the pump, it needs about 23 hours with an expert, but this system can be only 80 seconds without an expert.

  • PDF

Implementation of Ethernet-Based High-Speed Data Communication for Multi-core DSP (멀티 코어 DSP를 위한 이더넷 기반 고속 데이터 통신 구현)

  • Nguyen, Dung Huy;Choi, Joon-Young
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.17 no.3
    • /
    • pp.185-190
    • /
    • 2022
  • We propose a high speed data communication method for motor drive systems with fast control cycle in order to collect state variables of motor control without degrading control performance. Ethernet is chosen for communication device, and multi-core DSP architecture is exploited for communication processing load distribution. The communication program including network protocol stack and motor control program are assigned to two separate cores, and data between two cores are exchanged using interrupt-based inter-process communication mechanism, which enables to achieve a high-speed communication performance without degrading the motor control performance. The performance of developed communication method is demonstrated by real experiments using TCP, UDP and Raw Socket protocols in an experimental setup consisting of TI's TMS320F28388D motor control card and MS Windows PC.

A Study on High School Students' Awareness of Gender Equality and Clothing Attitude (고등학생의 양성평등의식과 의복태도와의 관련 연구)

  • Lee, Eun-Hee
    • Korean Journal of Human Ecology
    • /
    • v.14 no.6
    • /
    • pp.1007-1015
    • /
    • 2005
  • The purpose of this study was to investigate the relationship between the awareness of gender equality and clothing attitude of high school students. The survey was conducted on 600(male 297, female 303) high school students located in Choongnam and Jeollabukdo province. The statistical analysis was done with SPSS 11.0 for Windows Program to calculate percentile, mean and standard deviation. Also, the significance of the data was verified by Factor analysis, t-test, one-way ANOVA, Duncan' multiple range test. The results of this research were as follows: The results of analysing the factors to the response attitude toward appearance emerged four factors (sexual attractiveness, fashion pursuit, self-expression, aesthetic, and modesty). Gender had significant effects on the awareness of gender equality and clothing attitude of high school students. Gender equality awareness of high school students had an effects on clothing attitude. A group with high awareness score of gender equality showed high score in clothing attitude, fashion pursuit, self-expression, and aesthetic. A group with low awareness of gender equality, however, showed high in clothing attitude, sexual attractiveness and modesty.

  • PDF

Association between obesity and high-sensitivity C-reactive protein in Korean adults without cardiovascular disease

  • Heashoon, Lee
    • Journal of Korean Biological Nursing Science
    • /
    • v.25 no.1
    • /
    • pp.32-42
    • /
    • 2023
  • Purpose: This study aimed to investigate the association between obesity and high-sensitivity C-reactive protein (hs-CRP) levels in Korean adults without cardiovascular disease (CVD). Methods: The subjects were 3,634 adults, and data were extracted from the seventh Korea National Health and Nutrition Examination Survey (KNHANES VII-3). A complex sampling design analysis was applied to reflect the stratified and clustered weights. The data were analyzed using the complex sample Rao-Scott chi-square test and multiple logistic regression analysis (in SPSS for Windows version 26.0). Obesity, according to body mass index (BMI), was defined as obesity (BMI = 25-29.9 kg/m2), high obesity (BMI = 30-34.9 kg/m2), and super-high obesity (BMI ≥ 35 kg/m2), and abdominal obesity (AO) was defined as a waist circumference (WC) ≥ 90 cm in males and WC ≥ 85 cm in females. Results: The odds ratios for moderate CVD risk (hs-CRP; 1-3 mg/dL) were 2.21, 4.16, and 7.13 in the obesity, high obesity, and super-high obesity groups, respectively, compared to the normal BMI group. The odds ratio for moderate CVD risk was 2.18 in males with AO and 1.88 in females with AO. The odds ratios for high CVD risk (hs-CRP > 3 mg/L) were 4.40 and 17.55 in the high obesity and super-high obesity groups, respectively, compared to the normal BMI group. Conclusion: This study provides evidence that early detection and prevention programs for CVD should include obesity-related interventions aiming to modulate hs-CRP.

Analysis on TVOC Concentrations and Influence Factors of Newly-Built Apartments (신축 아파트의 총휘발성유기화합물 농도와 관련요인 분석)

  • Choi, Yoon-Jung;Kang, Mi-Ra;Lee, Hye-Min;An, Hye-Jung
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2006.05a
    • /
    • pp.268-271
    • /
    • 2006
  • The purpose of this study was to identify the influence of living factors on TVOC(Total Volatile Organic Compounds) concentrations for newly-built apartments. The field measurements of TVOC concentrations were made totally 30 times(5 times per one subject house) in six apartment units in which residents recently moved. Those apartments authorized its business approval before May 2004, the Act of Indoor Air auality Management for multi-use facilities. The findings were as follows: The TVOC concentrations of the measured subject apartments ranged from about 1/10 of the recommended standard for multi-use facilities($400{\mu}g/m^3$) to up to 90 times as high as the standard. Since then, the Recommended Standard of Indoor Air Quality Management for newly-built apartment house was announced in December 2005. In accordance with this standard($2390{\mu}g/m^3$) it ranged from about 1/100 to up to 15 times as high as the standard. The subject house whose TVOC concentrations reduced below the recommendation standard in the shortest period had the largest amount of ventilation (all the windows were open for ventilation in the past three months) among ail measured houses. The reason of another house whose TVOC concentrations were much higher than the rest was fronted with new furniture in the room. It's recommended that they should open all the windows for at least three months for ventilation in newly-built houses, and it would be better to avoid remodeling than needs be.

  • PDF

Research on the Images and Preference of Work Values of the Dental Laboratory Technician (치과기공사의 이미지와 선호도 조사)

  • Choi, Esther;Kwon, Eun-Ja;Song, Kwui-Sook
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.1
    • /
    • pp.339-347
    • /
    • 2009
  • The study surveyed 350 people who are over 18 and not related to dentistry with questionnaires in order to examine image and preference of dental technicians. The data analysis was done using the SPSS 21.0 for Windows. As for the analysis methods, the study used the frequency analysis, percentage, t-test, f-test. Through these analyses, the following conclusions were made. The score on the image of dental technicians declined in the order of occupational image(3.62), work image(3.46). The necessity of professional knowledge and techniques in the occupational image had the highest score with 4.17. Also, the image showing that it is professional had a score of 4.14 and the image that shows hardworking and stressful occupation showed the lowest score with 2.43. The study on the preference of dental technicians showed a low score of 2.67. The respondents who are in the 20s(3.53), and who are students(3.29) showed a high score. Also, people who have monthly income of less than 1.5 million won showed a high score of 2.91.With the help of information technology.

A Development of DCS Binding Delay Analysis System based on PC/Ethernet and Realtime Database

  • Gwak, Kwi-Yil;Lee, Sung-Woo;Lim, Yong-Hun;Lee, Beom-Seok;Hyun, Duck-Hwa
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1571-1576
    • /
    • 2005
  • DCS has many processing components and various communication elements. And its communication delay characteristic is affected diverse operating situation and context. Especially, binding signal which traversed from one control-node to another control-node undergo all sort of delay conditions. So its delay value has large deviation with the lapse of time, and the measurement of delay statistics during long time is very difficult by using general oscilloscope or other normal instruments. This thesis introduces the design and implementation of PC-based BDAS(Binding Delay Analysis System) System developed to overcomes these hardships. The system has signal-generator, IO-card, data-acquisition module, delay-calculation and analyzer module, those are implemented on industrial standard PC/Ethernet hardware and Windows/Linux platforms. This system can detect accurate whole-system-wide delay time including io, control processing and network delay, in the resolution of msec unit, and can analyze each channel's delay-historic data which is maintained by realtime database. So, this system has strong points of open system architecture, for example, user-friendly environment, low cost, high compatibility, simplicity of maintenance and high extension ability. Of all things, the measuring capability of long-time delay-statistics obtained through historic-DB make the system more valuable and useful, which function is essential to analyze accurate delay performance of DCS system. Using this system, the verification of delay performance of DCS for nuclear power plants is succeeded in KNICS(Korea Nuclear Instrumentation & Control System) projects

  • PDF

A Study on the Problems of the Occupants for the Aspects of the Improper Construction of Housing ( II ) - The Relations between the Actual Conditions (주택의 하자발생으로 인한 소비자문제에 관한 연구( II ) - 주택특성에 따른 하자실태와 피해유형과의 관계 -)

  • 강순주
    • Journal of the Korean housing association
    • /
    • v.3 no.2
    • /
    • pp.75-88
    • /
    • 1992
  • The purpose of this study is to analyze the relations between the conditions of the flaws and the types of damage according to the characteristics of housing, and then to provide with some basic data for the construction of houses of good quality. The effective analytic data for this research are 558 of all 700 questionnaires gathered through distribution collection and personal interviews conducted from June 22, 1992 Through to July 6, towards the first occupants in apartment houses, tenement houses, multidetached houses, multifamily houses and detached houses that last 10 years after construction, located in Seoul and Kyungki-Do. Our major findings are as under:1) Our data reveal that the ratio of flaw occurrence by general type breaks down into noise 53.7%, crack 39.3%, dew condensation 36.9%, windows and doors 36.6%, structure and frame 35.3%, built-in materials 33.3%, the inferiority of equipments/facilities 29.0%, ill drainage 22.0%, and the leakage of water 19.3% average number of flaw occurrence, multi detached house is the highest as 13.7, apartment house 10.5, tenement house 10.5, detached house 10.51 and multifamily house 8.7.3) As regards the degree of flaw occurrence, the flaw of noise is as serious in the degree of occurence as it is high in the ratio of occurrence. Particularly, the following contrastive phenomena are found: multidetached house is normal (2.0) in the degree of occurrence but it is high in the ratio of occurrence: while multifamily house is 2.9 in the degree of occurrence but it is low in the ratio of occurrence.4) In view of the relations between the types of flaws and those of damage, the flaw type which significantly influences on the injury of spirit and health is built-in materials; the flaw types that have considerable effect on the damage of house and home life are the inferiority of equipments/facilities, due condensation, and inferior windows and doors; and the flaw types that have a bad influence over the reliance on the constructors are the inferiority of equipments/facilities, due condensation and built-in materials.

  • PDF

An Experimental Study on Development of a Window Sprinkler for Fire Spread Prevention along Building External Walls (건물 외벽 화재확산 방지용 윈도우 헤드의 개발을 위한 실험적 연구)

  • Kwark, Jihyun;Kim, Dong-Jun
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.8-13
    • /
    • 2013
  • In case of fire in a high-rise building fire can be easily spread along the building external walls dramatically if the flame comes out through broken windows. There are a few effective methods to prevent the fire spread at the moment. One is using a fire resistance window, and the other is using a window sprinkler that discharges water to resist flame in case of fire. In this study a window sprinkler which is installed on top of windows and prevents fire by discharging water when its heat-responsive element opens was tested using a large scale furnace in accordance with the standard temperature-time graph. Test result showed that one window sprinkler was able to protect a 2,400 mm wide window from fire for 2 hours and the window backside's temperature locally increased up to $126^{\circ}C$ but kept stable around $100^{\circ}C$ for the test duration.

TVOC Concentrations and Residents' Responses on Sick House Syndrome of Newly-Built Apartments (신축 아파트의 TVOC 농도 및 거주자의 새집증후군 반응)

  • Choi Yoon-Jung;An Hye-Jung;Kang Mi-Ra;Lee Hye-Min
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.4 s.57
    • /
    • pp.129-137
    • /
    • 2006
  • The purpose of this study was to identify the influence of living factors on TVOC(Total Volatile Organic Compounds) concentrations and personal factors to reduce the Sick House Syndrome for newly-built apartments. The field measurements of TVOC concentrations were made totally 30 times(5 times per one subject house) in six apartment units in which residents recently moved. Those apartments authorized its business approval before May 2004, the Act of Indoor Air Quality Management for multi-use facilities. The Questionnaire surveys of residents' subjective responses on the Sick House Syndrome were carried out in 2nd measurement of each house. Respondents consisted of 20 residents living in the measured houses. The findings were as follows: The TVOC concentrations of the measured subject apartments ranged from about 1/10 of the recommended standard for multi-use facilities($400{\mu}g/m^3$) to up to 90 times as high as the standard. Since then, the Recommended Standard of Indoor Air Quality Management for newly-built apartment house was announced in December 2005. In accordance with this standard($2390{\mu}g/m^3$) it ranged from about 1/100 to up to 15 times as high as the standard. The subject house whose TVOC concentrations reduced below the recommendation standard in the shortest period had the largest amount of ventilation (all the windows were open for ventilation in the past three months) among all measured houses. The reason of another house whose TVOC concentrations were much higher than the rest was fronted with new furniture in the room. There turned out to be no apparent relations between the TVOC concentrations and the residents' individual responses of Sick House Syndrome. The responses were serious in those who stayed in their new houses for a long period or had disease like allergy. It's recommended that they should open all the windows for at least three months for ventilation in newly-built houses, and it would be better to avoid remodeling than needs be.