• 제목/요약/키워드: High voltage insulator

검색결과 300건 처리시간 0.032초

전계제한테와 측면 유리 절연층을 사용한 고내압 소자의 항복 특성 연구 (A Study on the Breakdown Characteristics of High Voltage Device using Field Limiting Ring and Side Glass Insulator Wall)

  • 허창수;추은상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1072-1074
    • /
    • 1995
  • Zinc-Borosilicate is used as a side insulastor wall to make high breakdown voltage with one Field Limiting Ring in a p-n junction. It is known that surface charge can be yield at the interface of Zinc-Borosilicate Glass/Silicon system. When the glass is used as a side insulator wall, surface charge varied potential distribution and breakdown voltage improved more than 660V without using more FLR.

  • PDF

트래킹 휠과 복합열화시험에 의한 폴리머 애자의 성능 평가 (Performance Evaluation of Polymer Insulator using Tracking Wheel and Multi-Aging Test)

  • 조한구;안명상;한세원;허종철;이운용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.119-122
    • /
    • 2000
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators for transmission line have significant advantages over porcelain and glass insulators, especially for ultra-high voltage transmission lines. Their advantages are light weight, vandalism resistance and hydrophobicity. Polymer insulators are a relatively new technology, but their expected life is still unknown. Therefore these estimating technique are very important. Their life time is related to weathering and operating condition. Multi-aging test is requested because aging factor is occurred by multi-aging than unique aging. The aging test about polymer insulators have mainly carried out by IEC 61109. This paper presents multi-stress chamber experiments and tracking wheel test to examine the tracking and erosion performance of polymer insulator for transmission. Multi-stress testing is able to demonstrate deficiencies of polymer insulator materials and designs, including the nature of interfaces in insulation design. We have investigated IEC 61109 Annex C (5000h aging test) and CEA tracking wheel test as test methods of artificial accelerated aging. The aging degree of polymer insulator is estimated by leakage current, measurement of hydrophobicity degree, damage conditions of insulator surface, withstand voltage test etc.

  • PDF

Electrical Characteristics of Organic Thin-film Transistors with Polyvinylpyrrolidone as a Gate Insulator

  • Choi, Jong-Sun
    • Journal of Information Display
    • /
    • 제9권4호
    • /
    • pp.35-38
    • /
    • 2008
  • This paper reports the electrical characteristics of polyvinylpyrrolidone (PVPy) and the performance of organic thin-film transistors (OTFTs) with PVPy as a gate insulator. PVPy shows a dielectric constant of about 3 and contributes to the upright growth of pentacene molecules with $15.3\AA$ interplanar spacing. OTFT with PVPy exhibited a field-effect mobility of 0.23 $cm^2$/Vs in the saturation regime and a threshold voltage of -12.7 V. It is notable that there was hardly any threshold voltage shift in the gate voltage sweep direction. Based on this reliable evidence, PVPy is proposed as a new gate insulator for reliable and high-performance OTFTs.

초고압 현수애자의 Pin 형상에 따른 응력해석 (Analysis for Stress According to Pin Type of High Voltage Suspension Type Insulator)

  • 조한구;박기호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.140-142
    • /
    • 2001
  • In this study mechanical for stress according to Pin type of high voltage suspension type insulator. R-shaped metal pin. and a tapered metal pin having a tensile pin having a tensile strength of more than the breaking strength of insulating body are provided in porcelain insulating bodies, and a suspension insulator according to the present invention, a test for determining the tensile strength of the insulating body was made and the results. These insulators are designed and produced by using the computer analysis of mechanical and electrical stresses together with the technical know-how accumulated from long year of study into every respect of insulators.

  • PDF

고유전 $(Bi_{1.5}Zn_{1.0}Nb_{1.5}O_7)_{0.7}(MgO)_{0.3}$ 게이트 절연막을 이용한 저전압 구동 상온공정 ZnO 박막트랜지스터 (Low-Voltage, Room temperature Fabricated ZnO Thin Film Transistor using High-K $(Bi_{1.5}Zn_{1.0}Nb_{1.5}O_7)_{0.7}(MgO)_{0.3}$ Gate Insulator)

  • 조남규;김동훈;김경선;김호기;김일두
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.96-96
    • /
    • 2007
  • Low voltage organic TFTs (OTFTs) and ZnO based TFTs (<5V), utilizing room temperature deposited $Bi_{1.5}Zn_{1.0}Nb_{1.5}O_7$ (BZN) thin films were recently reported, pointing to high-k gate insulators as a promising route for realizing low voltage operating flexible electronics. $Bi_{1.5}Zn_{1.0}Nb_{1.5}O_7$ (BZN) thin film is one of the most promising materials for gate insulator because of its large dielectric constant (~60) at room temperature. However their tendency to suffer from relatively high leakage current at low electric field (>0.3MV/cm) hinder the application of BZN thin films for gate insulator. In order to improve leakage current characteristics of BZN thin film, we mixed 30mol% MgO with 70mol% BZN and their dielectric and electric properties were characterized. We fabricated field-effect transistors with transparent oxide semiconductor ZnO serving as the electron channel and high-k $(Bi_{1.5}Zn_{1.0}Nb_{1.5}O_7)_{0.7}(MgO)_{0.3}$ as the gate insulator. The devices exhibited low operation voltages (<4V) due to high capacitance of the $(Bi_{1.5}Zn_{1.0}Nb_{1.5}O_7)_{0.7}(MgO)_{0.3}$ dielectric.

  • PDF

765 kV용 400 kN 현수애자 개발 (Development of Extra High Voltage(400kN) Porcelain Insulator for Transmission Lines)

  • 최인혁;최장현;이동일;최연규
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권8호
    • /
    • pp.348-353
    • /
    • 2003
  • This paper was the research of high voltage suspension insulator (400 [kN]) including pottery stone, feldspar, clay and alumina of 17 [wt%]. The slurry was fabricated after ball milling mixed raw materials. Green compacts were made by the extrusion of jiggering method and were sintered at 1300[$^{\circ}C$] for 50 [min.] in the tunnel kiln. The sintered density was reached to 97% of theoretical density, and the bending strength was 1658 [k $g_{f}$/$\textrm{cm}^2$] and hardness and fracture toughness which was measured by ICL( indentation crack length ) method were 1658 (kgf/$\textrm{cm}^2$) and 27.5 [Gpa], respectively. In measurement of tana and insulation break voltage of 400 (kN) porcelain, tan$\delta$ took some numerical value between 17${\times}$10$_{-3}$ and 61${\times}$10$_{-3}$ and insulation break voltage value was 19.9$\pm$1.4 [㎸/mm]. The test was performed to research whether the shape of pin affect a overvoltage break load or not As a consequence, when a pin was designed a pin diameter 51 [mm] with the bottom form of two-step constructed with straight in the suspension insulator, Insulator showed overvoltage break load 52 [ton] of the highest value and reflected a fine characteristic in aged deterioration test which is one of the accelerated aging test. Also it could be confirmed a fine characteristic through performing the test that electrical property of insulator was established correctly in accordance with IEC 60383-1 standards.s.

송전선로 활선 애자 청소 및 점검용 로봇 기구부의 개발 (Development of Robot Mechanism for Cleaning and Inspection of Live Line Insulator)

  • 박준영;조병학;변승현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.421-423
    • /
    • 2005
  • Power transmission lines have been playing a key role as the mainstay of national industry. When a power failure occurs, it can have severe effects on national security as well as national industry and economy. In this paper, we consider an insulator failure, which is one of the main causes of such a power failure. In spite of its importance, however, a shortage of manpower in the insulator maintenance field is getting more serious due to working environments with a high voltage and a high place. For this reason, a new active maintenance technique using a robot system is required to prevent such an insulator failure. In this paper, a new robot mechanism for insulator cleaning and inspection was developed. We confirmed its effectiveness through experiments.

  • PDF

가공 송전설비의 소음 특성 (Characteristics of Wind Noise from Overhead Transmission Facilities)

  • 추장희;김상범;신구용;이성두;이동일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.465-472
    • /
    • 2001
  • This paper describes the characteristics of wind induced noise from high-voltage overhead transmission facilities which include transmission lines. insulator strings. and aviation beacon spheres installed on the overhead ground wires. High-voltage overhead transmission lines generate an audible wind noise due to the alternate shedding of wind-induced vortices. The frequency spectrum from the insulator strings reveals its resonance peak. This resonance sound mechanism has been supposed the self-excitation phenomenon of the resonance and the velocity fluctuation. The booming noises from the aviation beacon spheres are detected and analysed.

  • PDF

배전용 폴리머 현수애자의 설계해석 (The Design Analysis of Distribution Polymer Suspension Insulator)

  • 이운용;조한구;한동희;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.66-68
    • /
    • 2001
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators for transmission and distribution line have significant advantages over porcelain and glass insulators, especially for ultra-high voltage(UHV) transmission lines. Their advantages are light weight, vandalism resistance and hydrophobicity. In this paper, distribution polymer suspension insulator has been designed and investigated electric field distribution by FEM.

  • PDF

UV 센서 어레이를 이용한 폴리머 애자의 코로나 방전 신호분석 연구 (A Study on the Signal Analysis of Corona Discharge on the Polymer Insulator using UV Sensor Array)

  • 최명일;김재철
    • 조명전기설비학회논문지
    • /
    • 제28권4호
    • /
    • pp.16-20
    • /
    • 2014
  • To prevent any accident in electric power utilities, many researches for inspection and diagnosis deteriorations occurring by corona discharges have been continuously studying. Inspection and diagnosis of electric power utility is very important to prevent an accident. This paper studies a measurement of ultra-violet(UV) ray of corona discharges on polymer insulators using an UV sensor array with an optic lens. The detection of an UV signal begins at 60kV, which is about 37.5% of the breakdown voltage of the polymer insulator and the stronger the high voltage increased to the polymer insulator was. It can be determined that the polymer insulator mounted on a live part must be examined when the discharge risk exceeds approximately 40%. In conclusion, the status of power utilities can be checked using an UV sensor.