• 제목/요약/키워드: High temperature performance

검색결과 3,904건 처리시간 0.035초

Temperature-Dependent Mn Substitution Effect on LiNiO2

  • Seungjae Jeon;Sk. Khaja Hussain;Jin Ho Bang
    • Journal of Electrochemical Science and Technology
    • /
    • 제15권1호
    • /
    • pp.161-167
    • /
    • 2024
  • Despite the important role of manganese (Mn) in cobalt-free, Ni-rich cathode materials, existing reports on the effects of Mn as a substitute for cobalt are not consistent. In this work, we analyzed the performance of cathodes comprised of Li(Ni1-xMnx)O2 (LNMO). Both beneficial and detrimental results occurred as a result of the Mn substitution. We found that a complex interplay of effects (Li/Ni mixing driven by magnetic frustration, grain growth suppression, and retarded lithium insertion/extraction kinetics) influenced the performance and was intimately related to calcination temperature. This indicates the importance of establishing an optimal reaction temperature for the development of high-performance LNMO.

Temperature Controllable HPLC Column for Preparative Fractionation of Polymers

  • Im, Kyu-Hyun;Park, Hae-Woong;Kim, Young-Tak;Chang, Tai-Hyun
    • Macromolecular Research
    • /
    • 제16권6호
    • /
    • pp.544-548
    • /
    • 2008
  • An HPLC column with a self-contained temperature control device was constructed for preparative temperature programmed interaction chromatography. Two Peltier plates were attached to a large bore column ($120{\times}22\;mm$ i.d.) and the column temperature was controlled by PID mode feed back control. At a flow rate of 1.5 mL/min, the column temperature could be increased and decreased at a rate as high as $50^{\circ}C/min$ and $10^{\circ}C/min$, respectively, which is much faster than using a column jacket and bath/circulator. The rapid heating and cooling rates allows a high repetition rate of chromatographic fractionation. The performance of the temperature controllable column was demonstrated successfully by the fractionation of homo-polymer precursors from diblock copolymers.

Residual behavior of SRRAC beam and column after exposure to high temperatures

  • Zhou, Ji;Chen, Zongping;Zhou, Chunheng;Zheng, Wei;Ye, Peihuan
    • Steel and Composite Structures
    • /
    • 제45권3호
    • /
    • pp.369-388
    • /
    • 2022
  • Composite effect between steel and recycled aggregate concrete (RAC) in steel reinforced-RAC (SRRAC) structures can effectively improve RAC's adverse mechanical properties due to the natural defects of recycled coarse aggregate (RCA). However, the performance of SRRAC after thermal exposure will have a great impact on the safety of the structure. In this paper, firstly, the mechanical properties of SRRAC structures after high temperatures exposure were tested, including 24 SRRAC columns and 32 SRRAC beams. Then, the change rules of beams and columns performance with the maximum temperature and replacement percentage were compared. Finally, the formulas to evaluate the residual bearing capacity of SRRAC beams and columns after exposure to high temperatures were established. The experimental results show that the maximum exposure temperature can be judged by the apparent phenomenon and mass loss ratio of RAC. After high temperatures exposure, the mechanical properties of SRRAC beams and columns change significantly, where the degradation of bearing capacity and stiffness is the most obvious. Moreover, it is found that the degradation degree of compression member is more serious than that of flexural member. The formulas of residual bearing capacity established by introducing influence coefficient of material strength agree well with the experimental results.

Development of High Performance Stainless Steel Powders

  • Schade, Christopher;Schaberl, John;Narasimhan, Kalathur S.
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part 1
    • /
    • pp.169-170
    • /
    • 2006
  • Advanced melting technology is now being employed in the manufacture of stainless steel powders. The new process currently includes electric arc furnace (EAF) technology in concert with Argon Oxygen Decarburization (AOD), High Performance Atomizing (HPA) and hydrogen annealing. The new high performance-processing route has allowed the more consistent production of existing products, and has allowed enhanced properties, such as improved green strength and green density. This paper will review these processing changes along with the potential new products that are being developed utilizing this technology. These include high strength stainless steels such as duplex and dual phase as well as stainless steel powders used in high temperature applications such as diesel filters and fuel cells.

  • PDF

Effects of Varying Dietary Zinc Levels and Environmental Temperatures on the Growth Performance, Feathering Score and Feather Mineral Concentrations of Broiler Chicks

  • Lai, P.W.;Liang, Juan-Boo;Hsia, L.C.;Loh, T.C.;Ho, Y.W.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제23권7호
    • /
    • pp.937-945
    • /
    • 2010
  • This study aimed to investigate the effects of dietary zinc (Zn), environmental temperatures and Zn${\times}$temperature interaction on growth, feathering score and mineral composition of broilers. A total of 256 d-old Avian male broiler chicks were randomly allocated to a $4{\times}2$ factorial arrangement with four corn-soybean meal basal diets (containing 44 mg Zn/kg) supplemented with 0, 40, 60 mg/kg Zn (Diets 1, 2 and 3, respectively; 0.8% Ca for these three diets) and non-Zn supplementation, 1.6% Ca (Diet 4) and two temperature conditions (low: 26, 24, $22^{\circ}C$ vs. high: 30, 28, $26^{\circ}C$). All birds were given feathering coverage scores for back, breast, wing, under-wing and tail. The wing and tail were further evaluated for the occurrence and severity of defect feathers. Feathers were then pooled for mineral composition analysis. The results showed that in high temperature conditions, broilers fed Zn-unsupplemented, 0.8% Ca ration (Diet 1) had significantly (p<0.05) lower ADFI and ADG (wk 1-6) than birds under low temperature conditions. However, when the birds were fed 40 and 60 mg/kg Zn supplementation (Diets 2 and 3), the ADFI and ADG in both temperature conditions were not significantly different. In low temperature conditions, the ADFI, ADG (p<0.05), all feather coverage (p<0.01) and tail defect scores (p<0.001) of birds fed Diet 4 (excess Ca) were significantly poorer than those fed Diet 1. More Ca (p<0.05) was retained in the feathers of broilers fed Diet 4 under high temperature conditions. Broilers fed the Zn-unsupplemented ration (Diet 1) had significantly higher feather phosphorus (p<0.01) and potassium (p<0.05) concentrations than those fed the 60 mg/kg Zn-supplemented ration (Diet 3). A reduction of feather phosphorus (p<0.01) and potassium (p<0.05) and higher manganese (p<0.05) concentrations were observed in Diet 4 broilers as compared to those fed Diet 1. Under high temperature conditions, broilers had lower iron (p<0.05) and higher manganese (p<0.05) concentrations in feathers. Broilers kept in high temperature conditions had a higher Zn requirement and 40 mg/kg Zn supplementation was sufficient for the birds to achieve optimum growth. Supplemental Zn ameliorated the adverse effect of high temperature on growth and occurrence of tail feather defects. Excess Ca disrupted Zn metabolism to exert a detrimental effect on growth performance and normal feathering and this was elucidated in the birds kept in low temperature conditions.

통기식 디스크 브레이크의 방열 성능에 관한 수치적 연구 (A Numerical Study of Thermal Performance in Ventilated Disk Brake)

  • 김진택;백병준
    • Tribology and Lubricants
    • /
    • 제17권5호
    • /
    • pp.358-364
    • /
    • 2001
  • Disk brake system transforms a large amount of kinetic energy to thermal energy in a short time. As the size and speed of automotive increases in recent years, the disk brakes absorbs more thermal energy. And this thermal energy can cause an unacceptable braking performance due to the high transient temperature, that is attained at the friction surface of brake disk and pad. Although these high temperatures are one of the biggest problems. In this study, the overall thermal behavior of ventilated disk brake system was investigated by numerical method. The 3-Dimensional unsteady model was simulated by using a general purpose software package “FLUENT” to obtain the temperature distributions of disk and pad. The model includes the more realistic braking method, which repeats braking and release. The effects of several parameters such as the repeated braking, inlet air velocity and thermal conductivity on the temperature distribution were investigated.

인젝션용 스크롤 압축기의 성능특성에 관한 실험적 연구 (Experimental Study on the Performance Characteristics of an Injection Type Scroll Compressor)

  • 조홍현;김용찬
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.193-198
    • /
    • 2000
  • For an inverter-driven compressor, the discharge temperature increased with a rise of frequency, Therefore, it is necessary to control the discharge temperature at high frequencies in order to obtain system reliability and efficiency. This paper describes the effects of liquid injection system on the performance of an inverter-driven scroll compressor. Experiments were performed at ASHRAE-T conditions. Frequency was altered from 45 to 105Hz. As results of the present work, the refrigerant discharge temperature fur the injection system was dropped approximately $10{\sim}20^{\circ}C$ as compared to those for the non-injection system. The COP of the compressor was improved approximately $0.8{\sim}9.3%$ at high frequencies(75, 90, and 105 Hz).

  • PDF

패시브환기외피의 열성능 수치시뮬레이션 (Numerical Simulation on Thermal Performence of Passive Ventilation Skin)

  • 이태철;손유남;윤성환
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.144-149
    • /
    • 2011
  • This study aims to evaluate performance of ventilation and thermal about breathing wall by flowing air to indoor on appropriate conditions that is effective aperture area in the Central region(20, 50, $80cm^2/m^2$). The result is as follows : 1) Sectional temperature distribution of inflow and outflow out under the constant ventilation was reviewed. In the case of inflow, outside temperature increase effect was confirmed. 2) The more differences of temperature between outdoor and indraft of air was high, the more heat recovery was high.

  • PDF

쇼케이스에서 고온가스 바이패스 및 단속운전 제상사이클의 성능특성에 관한 실험적 연구 (Experimental Study on the Performance Characteristics of Hot-gas Bypass and On-off Defrosting Cycle in a Showcase Refrigeration System)

  • 김용찬;조홍현;노현일;김영득;박윤철
    • 설비공학논문집
    • /
    • 제14권6호
    • /
    • pp.493-502
    • /
    • 2002
  • During the defrosting process, the temperature in the cabinet of a showcase becomes high as compared to the setting point, which is not desirable for stored foods or materials. It is necessary to develop a more efficient defrosting method to prevent large temperature fluctuation. In this study, the performance of a showcase refrigeration system with three evaporators is investigated by employing a hot-gas bypass defrosting technology in the system under frosting and defrosting conditions. The operating characteristics are compared with those for the on-off defrosting method that has been widely used in current products. As a result, the hot-gas bypass defrosting method shows higher refrigerating capacity and less temperature fluctuation than the on-off method under frosting/defrosting conditions, while the power input is relatively high for the hot-gas bypass method.

에너지 저장용 Li-Ion 배터리 팩의 열적 성능 평가에 관한 연구 (A Research on the Assessment of Thermal Performance of Energy Storage Li-Ion Battery Pack)

  • 장혁;장경민;김광선
    • 반도체디스플레이기술학회지
    • /
    • 제13권1호
    • /
    • pp.101-108
    • /
    • 2014
  • The battery pack in this research consists of dozens of a small battery for energy storage. And this battery pack charges and discharges repeatedly at high capacity (25 ~ 50 V, 25 ~ 100 A). The high temperature which can be generated in this process has a bad effect to the lifetime and efficiency of batteries. Moreover these factors are related with maintenance cost. Therefore, we need to assess the thermal performance of the battery pack in advance using the experimental or numerical analysis. In this research, we analyzed voltage and surface temperature of one cell battery to calculate heat transfer using the numerical analysis. And the temperature of the battery surfaces and inside of the pack was also analyzed. As a result, we found out the appropriate pack structure which stacked five modules.