• Title/Summary/Keyword: High step-up

Search Result 691, Processing Time 0.043 seconds

Numerical Analysis of Vortex Induced Vibration of Circular Cylinder in Lock-in Regime (Lock-in 영역에서 원형실린더의 와류유기진동 전산해석)

  • Lee, Sungsu;Hwang, Kyu-Kwan;Son, Hyun-A;Jung, Dong-Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.1
    • /
    • pp.9-18
    • /
    • 2016
  • The slender structures such as high rise building or marine riser are highly susceptible to dynamic force exerted by fluid-structure interactions among which vortex-induced vibration(VIV) is the main cause of dynamic unstability of the structural system. If VIV occurs in natural frequency regime of the structure, fatigue failure likely happens by so-called lock-in phenomenon. This study presents the numerical analysis of dynamic behavior of both structure and fluid in the lock-in regimes and investigates the subjacent phenomena to hold the resonance frequency in spite of the change of flow condition. Unsteady and laminar flow was considered for a two-dimensional circular cylinder which was assumed to move freely in 1 degree of freedom in the direction orthogonal to the uniform inflow. Fluid-structure interaction was implemented by solving both unsteady flow and dynamic motion of the structure sequentially in each time step where the fluid domain was remeshed considering the movement of the body. The results show reasonable agreements with previous studies and reveal characteristic features of the lock-in phenomena. Not only the lift force but also drag force are drastically increasing during the lock-in regime, the vertical displacement of the cylinder reaches up to 20% of the diameter of the cylinder. The correlation analysis between lift and vertical displacement clearly show the dramatic change of the phase difference from in-phase to out-of-phase when the cylinder experiences lock-in. From the results, it can be postulated that the change of phase difference and flow condition is responsible for the resonating behavior of the structure during lock-in.

Removal of Herbicide Molinate during treatment Processes for Drinking Water (상수처리과정 중 제초제 molinate의 제거)

  • Park, Ju-Hwang;Park, Jong-Woo;Kim, Jong-Soo;Kim, Jang-Eok
    • Applied Biological Chemistry
    • /
    • v.45 no.3
    • /
    • pp.145-151
    • /
    • 2002
  • Molinate, a thiolcarbamate herbicide widely used for control weeds in paddy soil, has been suspected for a possibile transportation into surface water due to its relatively high solubility in water. This study was performed to know that how much molinate could be removed during treatment processes for drinking water. The removal effciency of molinate in water was negligible in treatment process of polyaluminium chloride for coagulation. Molinate was gradually decreased up to 60.2% during contact time of 4 hours when chloride, an disinfectant used in water treatment system was treated. And in an hour treatment of ozone, molinate removal ranged $28.9%{\sim}58%$ However by treatment system of granular activated carbon, molinate was removed 93.9 to 100% at all concentrations used with a range of concentrations of granular activated carbon treated. The removal effciency of whole system simulated with removal efficiencies of molinate in each step of treatment processes was 99.5%. Therefore, if molinate happen to come into water treatment facilities, it could be removed effectively through the treatment processes.

Development of 1.2[kW]Class Fuel Cell Power Conversion System (1.2[kW]급 연료전지용 전력변환장치의 개발)

  • Suh, Ki-Young;Kim, Chil-Ryong;Cho, Man-Chul;Kim, Jung-Do;Yoon, Young-Byun;Kim, Hong-Sin;Park, Do-Hyung;Ha, Sung-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.6
    • /
    • pp.117-125
    • /
    • 2007
  • Recently, a fuel cell with low voltage and high current output characteristics is remarkable for new generation system. It needs both a DC-DC step-up converter and DC-AC inverter to be used in fuel cell generation system. Therefor, this paper, consists of an isolated DC-DC converter to boost the fuel cell voltage 380[VDC] and a PWM inverter with LC filter to convent the DC voltage to single-phase 220[VAC]. Expressly, The fuel cell system which it proposes DC-DC the efficient converter used PWM the phase transient control law and it depended to portion resonance ZVS switching, loss peek voltage and electric current of realization under make schedule, switching frequency anger and the switch reduction. And mind benevolence it sprouted 2 in stop circuit and it added and a direct current voltage and the electric current where the ingredient is reduced in load side ripple stable under make whom it will be able to supply. Besides the efficiency of 92[%]is obtained over the wide output voltage regulation ranges and load variations. Also, under make over together the result leads simulation and test, the propriety confirmation.

Registration Technique of Partial 3D Point Clouds Acquired from a Multi-view Camera for Indoor Scene Reconstruction (실내환경 복원을 위한 다시점 카메라로 획득된 부분적 3차원 점군의 정합 기법)

  • Kim Sehwan;Woo Woontack
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.42 no.3 s.303
    • /
    • pp.39-52
    • /
    • 2005
  • In this paper, a registration method is presented to register partial 3D point clouds, acquired from a multi-view camera, for 3D reconstruction of an indoor environment. In general, conventional registration methods require a high computational complexity and much time for registration. Moreover, these methods are not robust for 3D point cloud which has comparatively low precision. To overcome these drawbacks, a projection-based registration method is proposed. First, depth images are refined based on temporal property by excluding 3D points with a large variation, and spatial property by filling up holes referring neighboring 3D points. Second, 3D point clouds acquired from two views are projected onto the same image plane, and two-step integer mapping is applied to enable modified KLT (Kanade-Lucas-Tomasi) to find correspondences. Then, fine registration is carried out through minimizing distance errors based on adaptive search range. Finally, we calculate a final color referring colors of corresponding points and reconstruct an indoor environment by applying the above procedure to consecutive scenes. The proposed method not only reduces computational complexity by searching for correspondences on a 2D image plane, but also enables effective registration even for 3D points which have low precision. Furthermore, only a few color and depth images are needed to reconstruct an indoor environment.

A Study on FPGA Design for Rotating LED Display Available Video Output (동영상 표출이 가능한 회전 LED 전광판을 위한 FPGA 설계에 관한 연구)

  • Lim, Young-Sik;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.19 no.2
    • /
    • pp.168-175
    • /
    • 2015
  • In this paper, we propose FPGA design technique for rotating LED display device which is capable of displaying videos with the use of the afterimage effect. The proposed technique is made up of image data correction process based on inverse gamma correction and error diffusion, block interleaving process, and data serial output process. The data correction process based on inverse gamma correction and error diffusion is an image data correction step in which image data received are corrected by inverse gamma correction process to convert the data into linear brightness characteristics, and by error diffusion process to reduce the brightness reduction phenomenon in low-gray-level which is caused by inverse gamma correction. In the block interleaving process, the data of the frames entered transversely are first saved in accordance with entrance order, and then only the longitudinal image data are read. The data serial output process is applied to convert the parallel data in a rotating location into serial data and send them to LED Driver IC, in order to send data which will be displayed on high-speedy rotating LED Bar. To evaluate the accuracy of the proposed FPGA design technique, this paper used XC6SLX45-FG484, a Spartan 6 family of Xilinx, as FPGA, and ISE 14.5 as a design tool. According to the evaluation analysis, it was found that goal values were consistent with simulation values in terms of accurate operation of inverse gamma and error diffusion correction, block interleaving operation, and serialized operation of image data.

A Study on the Value of Island Landscape as Scenic Site Resource - Focus on the Raising Fine Village(Gwanmaedo, Youngsando) - (도서 경관의 명승자원으로서의 가치연구 - 명품마을(관매도, 영산도)을 중심으로 -)

  • Lee, Young-Yi;Lee, Jin-Hee;Kim, Jun;Lee, Jae-Keun
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.30 no.4
    • /
    • pp.93-101
    • /
    • 2012
  • Despite the fact that the importance of islands and oceans is increasingly being emphasized as they are recognized as alternative spaces for the future, some islands that have not been designated as cultural assets have lost their natural and cultural landscapes to development projects and other plans for turning islands into tourist resources, and are still in the process of being destroyed. Unlike old perceptions of islands, islands, in the minds of people living in the modern age, have become places for taking a quiet rest or enjoying and appreciating the undamaged beauty of nature itself. Keeping up with the trend of people increasingly visiting the islands these days, it is high time to prepare plans for the promotion, preservation management, and usages of islands based on researches of islands with excellent natural landscapes and through the designation of these islands as cultural properties. As the first step of studying island landscape resources as resources of cultural assets, the current study includes literature reviews and field investigations of Gwanmaedo and Yeongsando, two islands that have been selected as prestigious villages and are part of the Dadohaehaesang National Park. Based on these preliminary investigations, landscape resources showing distinctive natural landscapes and cultural sceneries were selected and analyzed in detail, thus presented for their value as resources of Scenic site and future research.

Prediction and Evaluation of Indoors Noise Level of Exhibition Room in Museum by Road Traffic Noise (도로교통소음으로 인한 박물관 전시실의 실내 소음레벨 예측 및 평가)

  • Lee, Kook-Hyun;Park, Yeong-Ji;Kim, Jae-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.8
    • /
    • pp.787-794
    • /
    • 2010
  • Recently, with sudden increase of supplying rate of cars and quantity of goods transported, traffic noisy becomes one of important factors obstruct environment of exhibition and view facilities have purpose in calmness and unsatisfaction about this is high now. Therefore, in case of exhibition and view facilities, it has to be grasped that satisfaction degree about the noisy in and out of the exhibition room by performing effect valuation on traffic noisy from design step. However the level of internal noise cannot be measured at the design phrase of the structure due to the noise of traffic. Up until now a walls transmission loss, based on the law of mass, is predicted using this method. However measuring the internal sound level after actual construction reveals that there is a large difference from measurements made at the design stage, and it is very difficult to find a solution after the opening of the structure. From research looking from this perspective the internal sound level was predicted- calculating the internal sound absorption ability, using acoustic simulation and loss prevention of an insulated wall- based on data collected to evaluate the internal sound of an exhibition room at a Folk Museum adjacent to a freeway. The results of this research are considered to provide important data for the prediction of internal sound level at the time of construction of exhibition facilities similar to this.

Determination of Unit Hydrograph for the Hydrological Modelling of Long-term Run-off in the Major River Systems in Korea (장기유출의 수문적 모형개발을 위한 주요 수계별 단위도 유도)

  • 엄병현;박근수
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.26 no.4
    • /
    • pp.52-65
    • /
    • 1984
  • In general precise estimation of hourly of daily distribution of the long-term run-off should be very important in a design of source of irrigation. However, there have not been a satisfying method for forecasting of stationar'y long-term run-off in Korea. Solving this problem, this study introduces unit-hydrograph method frequently used in short-term run-off analysis into the long-term run-off analysis, of which model basin was selected to be Sumgin-river catchment area. In the estimation of effective rainfall, conventional method neglects the Soil moisture condition of catchment area, but in this study, the initial discharge (qb) occurred just before rising phase of the hydrograph was selected as the index of a basin soil moisture condition and then introduced as 3rd variable in the analysis of the reationship between cumulative rainfall and cumulative loss of rainfall, which built a new type of separation method of effective rainfall. In next step, in order to normalize significant potential error included in hydrological data, especially in vast catchment area, Snyder's correlation method was applied. A key to solution in this study is multiple correlation method or multiple regressional analysis, which is primarily based on the method of least squres and which is solved by the form of systems of linear equations. And for verification of the change of characteristics of unit hydrograph according to the variation of a various kind of hydrological charateristics (for example, precipitation, tree cover, soil condition, etc),seasonal unit hydrograph models of dry season(autumn, winter), semi-dry season (spring), rainy season (summer) were made respectively. The results obtained in this study were summarized as follows; 1.During the test period of 1966-1971, effective rainfall was estimated for the total 114 run-off hydrograph. From this estimation results, relative error of estimation to the ovservation value was 6%, -which is mush smaller than 12% of the error of conventional method. 2.During the test period, daily distribution of long-term run-off discharge was estimated by the unit hydrograph model. From this estimation results, relative error of estimation by the application of standard unit hydrograph model was 12%. When estimating by each seasonal unit bydrograph model, the relative error was 14% during dry season 10% during semi-dry season and 7% during rainy season, which is much smaller than 37% of conventional method. Summing up the analysis results obtained above, it is convinced that qb-index method of this study for the estimation of effective rainfall be preciser than any other method developed before. Because even recently no method has been developed for the estimation of daily distribution of long-term run-off dicharge, therefore estimation value by unit hydrograph model was only compared with that due to kaziyama method which estimates monthly run-off discharge. However this method due to this study turns out to have high accuracy. If specially mentioned from the results of this study, there is no need to use each seasonal unit hydrograph model separately except the case of semi-dry season. The author hopes to analyze the latter case in future sudies.

  • PDF

Probabilistic Medium- and Long-Term Reservoir Inflow Forecasts (II) Use of GDAPS for Ensemble Reservoir Inflow Forecasts (확률론적 중장기 댐 유입량 예측 (II) 앙상블 댐 유입량 예측을 위한 GDAPS 활용)

  • Kim, Jin-Hoon;Bae, Deg-Hyo
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.3 s.164
    • /
    • pp.275-288
    • /
    • 2006
  • This study develops ESP (Ensemble Streamflow Prediction) system by using medium-term numerical weather prediction model which is GDAPS(T213) of KMA. The developed system forecasts medium- and long-range exceedance Probability for streamflow and RPSS evaluation scheme is used to analyze the accuracy of probability forecasts. It can be seen that the daily probability forecast results contain high uncertainties. A sensitivity analysis with respect to forecast time resolution shows that uncertainties decrease and accuracy generally improves as the forecast time step increase. Weekly ESP results by using the GDAPS output with a lead time of up to 28 days are more accurately predicted than traditional ESP results because conditional probabilities are stably distributed and uncertainties can be reduced. Therefore, it can be concluded that the developed system will be useful tool for medium- and long-term reservoir inflow forecasts in order to manage water resources.

Slit Ventricle Syndrome in Children : Clinical Presentation and Treatment (소아에서 틈새뇌실 증후군 : 임상 양상 및 치료)

  • Shin, Beom-Sik;Yang, Kook-Hee;Kim, Dong-Seok;Choi, Joong-Uhn
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup2
    • /
    • pp.309-315
    • /
    • 2001
  • The term slit ventricle syndrome(SVS) refers to an episodic occurrence of headache, vomiting, and possibly some degree of impaired consciousness in shunted hydrocephalic children in whom slit-like ventricles are seen on CT scan or MRI. Authors present 6 cases with SVS who were treated at our institute for last 10 years. From 1986 to 1996, 821 patients underwent shunt surgery for hydrocephalus. The etiology of hydrocephalus included brain tumor(140 patients), post-hemorrhagic(62 patients), idiopathic normotensive hydrocephalus(64 patients), post-meningitic( 58 patients), post-traumatic(54 patients), congenital(48 patients), neurocysticercosis(31 patients), and unknown etiology(364 patients). During the mean follow-up duration of 68 months, 232 shunt revisions were performed by a revision rate of 1.28 per patient. The incidence of SVS was 0.7%(6 patients). Most of them have been operated on in infancy. Time interval from the first operation to the development of slit-ventricle syndrome ranged from 4 to 8 years, the mean was 6 years. Shuntogram showed patent shunt in all patients. Two patients with less severe clinical symptoms improved with conservative treatment. These patients were not measured ICP because of good hospital course. One patient showed high ICP and needed only revision with same pressure valve as previous shunt. Low ICP was noted in 3 patients. Pressure augmentation using an anti-siphon device(ASD) or upgrading valve system were necessary in these patients. The authors stress that determining type of SVS is the first step in treatment planning and that the best treatment is a strategy aimed at resolving the specific type of SVS responsible for the symptoms.

  • PDF