• Title/Summary/Keyword: High school building

Search Result 1,049, Processing Time 0.032 seconds

Dynamic responses on traditional Chinese timber multi-story building with high platform base under earthquake excitations

  • Zhang, Xicheng;Ma, Hui;Zhao, Yanli;Zhao, Hongtie
    • Earthquakes and Structures
    • /
    • v.19 no.5
    • /
    • pp.331-345
    • /
    • 2020
  • The multi-story timber structure with high platform base is one of the important architectural types in the traditional Chinese buildings. To study the dynamic characteristics and seismic responses on this kind of traditional structure, the 3-D finite element models of Xi'an drum tower which included the high platform base, upper timber structure and whole structure was established considering the structural form and material performance parameters of the structure in this study. By the modal analysis, the main frequencies and mode shapes of this kind of traditional building were obtained and investigated. The three kinds of earthquake excitations included El-Centro wave, Taft wave and Lanzhou wave were separately imposed on the upper timber structure model and the overall structure model, and the seismic responses on the tops of columns were analyzed. The results of time history analysis show that the seismic response of the upper timber structure is obviously amplified by high platform base. After considering the effect of high platform base, the mean value on the lateral displacement increments of the top column in the overall structure is more than 20.478% and the increase of dynamic coefficients was all above 0.818 under the above three different earthquake excitations. Obviously, it shows that the existence of high platform base has a negative influence on the seismic responses of upper timber structure. And the high platform base will directly affect the safety of the upper timber structure. Therefore, the influence of high platform base on the dynamic response of its upper timber structure cannot be neglected.

Designation of Buildings in Urban Area of High-resolution Satellite Image Using Generalized Hough Transform

  • Lee, Seung-Hee;Park, Sung-Mo;Lee, Joon-Whoan;Kim, Joon-Cheol
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.156-158
    • /
    • 2003
  • Analysis of high-resolution satellite image becomes important for cartography, surveillance, and remote sensing. However, there are lots of problems to be solved for automatic analysis of high-resolution satellite image especially in urban area. The problems are originated from the increased complexity due to the unnecessary details and shadows, and time-varying illuminations. Because of such obstacles, it seems impossible to make automatic analysis. This paper proposes a way of change detection of buildings in urban area by using digital vector map. The proposed way makes the buildings on the vector map parameterized, and searches them in the preprocessed high-resolution image by using generalized Hough transform. The searched building objects are overlaid on the satellite image. The overlaid image can help to detect the change of building rapidly.

  • PDF

Conceptual design of buildings subjected to wind load by using topology optimization

  • Tang, Jiwu;Xie, Yi Min;Felicetti, Peter
    • Wind and Structures
    • /
    • v.18 no.1
    • /
    • pp.21-35
    • /
    • 2014
  • The latest developments in topology optimization are integrated with Computational Fluid Dynamics (CFD) for the conceptual design of building structures. The wind load on a building is simulated using CFD, and the structural response of the building is obtained from finite element analysis under the wind load obtained. Multiple wind directions are simulated within a single fluid domain by simply expanding the simulation domain. The bi-directional evolutionary structural optimization (BESO) algorithm with a scheme of material interpolation is extended for an automatic building topology optimization considering multiple wind loading cases. The proposed approach is demonstrated by a series of examples of optimum topology design of perimeter bracing systems of high-rise building structures.

Research on the Domain Formation of Living Base Space of Credit System High Schools - Focused on Japanese Comprehensive High Schools - (학점제 고등학교 생활거점공간의 영역 형성에 관한 연구 - 일본의 총합학과 고등학교를 대상으로 -)

  • Son, Suk-Eui;Kim, Seung-je
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.10
    • /
    • pp.3-10
    • /
    • 2019
  • The high school credit system is a system in which students select complete various subjects, depending on their career, and graduate when their accumulated credit reaches the standard. It is expected that the high school credit system, which guarantees the individual's right of choice, will bring an educational effect that can respond to the student's career aptitude. However, it is expected that problems in the aspect of school life, such as the weakening of class belongingness or difficulty of securing a stable base venue within the school building would be accompanied. This research analyzed students' usage condition depending on the living base space environment feature in schools that are implementing moving-selective class in the aspect of activity domain formation and contemplated the venue evaluation. The purpose is to provide the basic data of an architectural plan of a stable living base space within the school building through this. 'Living base center type' and 'living base dispersion type' school buildings among Japanese integral department high schools were used as the target to analyze the usage condition in the aspect of domain formation. As a result, a conclusion was deducted that student's securement of territory consciousness about the base space and venue construction for the community of various studying groups affects life satisfaction.

A Basic Study on Application of Small Wind Power System Combined Ventilator in Super High-rise Apartment (1) (초고층 공동주택의 배기겸용 소형풍력발전 적용을 위한 기초연구(1))

  • Park, Jung-Ha;Kim, Jin-Woo;Jang, Ho-Jin;Park, Jin-Chul;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.126-132
    • /
    • 2011
  • Recently, high-rise apartment is being briskly built but there are problems such as lack of ventilation, stack effect and much energy consumption. Therefore It is recommended to develop a Small Wind Power System Combined Ventilator as a solution to solve these problems. The purpose of this study is to provide basis for Small Wind Power System Combined Ventilator in super high-rise apartment. This study conducted CFD simulation (Star-CCM) according to the shape of structures, building height and distance of two structures to identify the effect of wind speed increase when the structure is installed. As a result, pyramidal type was best suited for increase of wind speed. The best place was the front of the roof to main wind direction, and the best building height was 200m rather than 300m. If two or more small wind turbines combined ventilator are installed closely, vertical position to main wind direction is recommended. Horizontal position must necessarily be avoided, but height difference between two blades more than 3m showed good performance.

Experimental study on deformation of concrete for shotcrete use in high geothermal tunnel environments

  • Cui, Shengai;Liu, Pin;Wang, Xuewei;Cao, Yibin;Ye, Yuezhong
    • Computers and Concrete
    • /
    • v.19 no.5
    • /
    • pp.443-449
    • /
    • 2017
  • Taking high geothermal tunnels as background, the deformation of concrete for shotcrete use was studied by simulating hot-humid and hot-dry environments in a laboratory. The research is made up by two parts, one is the influence of two kinds of high geothermal environments on the deformation of shotcrete, and the other is the shrinkage inhibited effect of fiber materials (steel fibers, polypropylene fibers, and the mixture of both) on the concrete in hot-dry environments. The research results show that: (1) in hot and humid environments, wet expansion and thermal expansion happened on concrete, but the deformation is smooth throughout the whole curing age. (2) In hot and dry environments, the concrete suffers from shrinkage. The deformation obeys linear relationship with the natural logarithm of curing age in the first 28 days, and it becomes stable after the $28^{th}$ day. (3) The shrinkage of concrete in a hot and dry environment can be inhibited by adding fiber materials especially steel fibers, and it also obeys linear relationship with the natural logarithm of curing age before it becomes stable. However, compared with no-fiber condition, it takes 14 days, half of 28 days, to make the shrinkage become stable, and the shrinkage ratio of concrete at 180-day age decreases by 63.2% as well. (4) According to submicroscopic and microscopic analysis, there is great bond strength at the interface between steel fiber and concrete. The fiber meshes are formed in concrete by disorderly distributed fibers, which not only can effectively restrain the shrinkage, but also prevent the micro and macro cracks from extending.

Building Height Extraction using Triangular Vector Structure from a Single High Resolution Satellite Image (삼각벡터구조를 이용한 고해상도 위성 단영상에서의 건물 높이 추출)

  • Kim, Hye-Jin;Han, Dong-Yeob;Kim, Yong-Il
    • Korean Journal of Remote Sensing
    • /
    • v.22 no.6
    • /
    • pp.621-626
    • /
    • 2006
  • Today's commercial high resolution satellite imagery such as IKONOS and QuickBird, offers the potential to extract useful spatial information for geographical database construction and GIS applications. Extraction of 3D building information from high resolution satellite imagery is one of the most active research topics. There have been many previous works to extract 3D information based on stereo analysis, including sensor modelling. Practically, it is not easy to obtain stereo high resolution satellite images. On single image performance, most studies applied the roof-bottom points or shadow length extracted manually to sensor models with DEM. It is not suitable to apply these algorithms for dense buildings. We aim to extract 3D building information from a single satellite image in a simple and practical way. To measure as many buildings as possible, in this paper, we suggested a new way to extract building height by triangular vector structure that consists of a building bottom point, its corresponding roof point and a shadow end point. The proposed method could increase the number of measurable building, and decrease the digitizing error and the computation efficiency.

Organizational Accountability in Health Care : Developing a Model for Analysis (의료기관의 조직 책무성 : 분석을 위한 모형 개발)

  • Lee, Geun-Chan;You, Myoung-Soon
    • Health Policy and Management
    • /
    • v.21 no.2
    • /
    • pp.213-248
    • /
    • 2011
  • Past studies on organizational accountability have had similar limitations. First, empirical evidence of organizational accountability is rare as the majority of research takes a conceptual approach of the topic. Only a few of these studies are applicable to health care organizations (HCOs). To fill these gaps, we attempted to develop a model for analysis of organizational accountability for HCOs. Accountability for HCOs was conceptualized by two axes: answerability(X, horizontal) and value-creation(Y, vertical). Our concept building could relieve competing accountability mechanism which past studies stressed. Four elements of accountability(legal, economical, social, and clinical) were applied to specify each of the two features of organizational accountability. And then four types of accountability behavior were coordinated by this x-y axis : high A/high VC, high A/low VC, low A/high VC, low A/low VC. Finally, a multidimensional model of HCOs' accountability, enabling an empirically testable multi-level analysis, was proposed.

Validation of applying Canopy model to predict wind environment of pedestrian level by CFD simulation (보행자 레벨의 풍환경 예측 시 Canopy Model을 적용한 CFD 시뮬레이션 타당성 검증)

  • Jung, Su-Hyeon;Hong, In-Pyo;Song, Doo-Sam
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.345-353
    • /
    • 2012
  • Recently rapid urbanization facilitates development of high-rise building complex including apartment and office building in urban area. Many problems related with high-rise building are reported. Especially, unpleasant strong winds in pedestrian area are frequently encountered around the high-rise building. CFD simulation methods are used to analyze the wind environment of pedestrian level in high-rise building block. However the results show differences between CFD and measurement. The reason for the difference is that conventional CFD simulation couldn't consider the effect of trees, shrubs and plants which affect the wind environment. Canopy model is a solution to solve the limitation of CFD analysis. In this paper, the canopy model to predict wind environment of pedestrian level by CFD simulation will be proposed and the validity will be analyzed by comparison of measurement and CFD prediction.

  • PDF