• Title/Summary/Keyword: High peak power

Search Result 913, Processing Time 0.025 seconds

Performance Analysis of SLM Method for PAR Reduction Based on OFDM System (OFDM 시스템에서 PAR 감소를 위한 SLM 기법의 성능 분석)

  • Lee, Sang-Geun;Lee, Yoon-Hyun;Jin, Seong-Woo
    • Journal of Advanced Navigation Technology
    • /
    • v.10 no.1
    • /
    • pp.20-25
    • /
    • 2006
  • In these days, OFDM(Orthogonal Frequency Division Multiplexing) is adopted to support high-speed data communication based on multi-path RF channel, but it has some weak point. One of those is that it has a higher PAR(peak-to-average power ratio) compared with single-carrier method. If some PAR of the transmitted signal is high, nonlinear amplitude distortion has occurred when it pass through the HPA(high power amplifier). There is a solution to prevent nonlinear distortion using higher peak power HPA, but it makes inefficiency and a cost problem. In this paper, we choose the SLM(Selected Mapping) scheme, which transmit the lowest PAR signal after OFDM symbol mapping, in various schemes reducing PAR for OFDM system. And we derived the performances of SLM method in fading channel through computer simulations.

  • PDF

Precise Analytical Solution for the Peak Gain of LLC Resonant Converters

  • Hong, Sung-Soo;Cho, Sang-Ho;Roh, Chung-Wook;Han, Sang-Kyoo
    • Journal of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.680-685
    • /
    • 2010
  • Although LLC resonant converters have the advantages of a wide operation range and high efficiency, the lack of an analytical solution for the peak gain makes it difficult to optimize the resonant tank design, when considering not only the normal condition but also the holdup time requirement. In this paper, based on a mathematical analysis of a LLC resonant converter at the peak gain point, an analytical solution for the peak gain has been developed. By using the developed analytical solution, the peak gain with given resonant tank parameters can be obtained. To confirm the validity of the developed analytical solution, simulations and experimental results are compared.

Solar ESS Peak-cut Simulation Model for Customer (수용가 대응용 태양광 ESS 피크컷(Peak-cut) 시뮬레이션 모델)

  • Park, Seong-Hyeon;Lee, Gi-Hyun;Chung, Myoung-Sug;Chae, U-ri;Lee, Joo-Yeuon
    • Journal of Digital Convergence
    • /
    • v.17 no.7
    • /
    • pp.131-138
    • /
    • 2019
  • The world's electricity production ratio is 40% for coal, 20% for natural gas, 16% for hydroelectric power, 15% for nuclear power and 6% for petroleum. Fossil fuels also cause serious problems in terms of price and supply because of the high concentration of resources on the earth. Solar energy is attracting attention as a next-generation eco-friendly energy that will replace fossil fuels with these problems. In this study, we test the charge-operation plan and the discharge operation plan for peak-cut operation by applying the maximum power demand reduction simulation. To do this, we selected the electricity usage from November to February, which has the largest amount of power usage, and applied charge / discharge logic. Simulation results show that the contract power decreases as the peak demand power after the ESS Peak-cut service is reduced to 50% of the peak-target power. As a result, the contract power reduction can reduce the basic power value of the customer and not only the economic superiority can be expected, but also contribute to the improvement of the electric quality and stabilization of the power supply system.

A Study on the Electrical-Fire Analysis and Firing Characteristics of Power Cord by Thermal Stress (열적 피로에 의한 전원코드의 발화 특성과 전기화재 분석에 관한 연구)

  • 최충석;송길목;김향곤;김동욱;김동우
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2003.04a
    • /
    • pp.164-170
    • /
    • 2003
  • In this paper, we studied on the firing characteristics and electrical fire analysis of power cord deteriorated by thermal stress. The cross section of PVC insulating cord deteriorated by indirect flame decreased through heat convection. PVC insulating cord deteriorated by direct flame was bumpy shape. The exothermic peak of normal cord was shown at ($526.7^{\circ}C$), but the peaks or on(heat treatment temperature) ($150^{\circ}C$) cord was shown at ($299.6^{\circ}C$) and [$502.2^{\circ}C$]. The exothermic peaks according to high temperature were similar to those of amorphous carbon. In the FT-IR analysis, the absorption peak of normal cord indicated double bond of oxygen and carbon in benzene ring at 1720.0$cm^{1}$. As the HTT was high, the height of characteristic peak decreased and the peak of carbonyl group was shown at about 1625.7$cm^{-1}$. The characteristic peak of single bond(O-H) was shown at about 3479.2$cm^{-1}$. In case of the internal part of wire covering deteriorated by over current, the characteristic peak were shown at about 3417.3$cm^{-1}$ and 1600.2$cm^{-1}$. The above results show that we can distinguish the differences according to the fire pattern through the internalㆍexternal analysis of wire covering deteriorated by heat.

  • PDF

A development of direct load control system for air-conditioner (원격제어 에어컨 개발 보급현황 및 향후전망)

  • Gang, Won-Gu;Kim, Choong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2446-2448
    • /
    • 2001
  • In addition to the stabilization of electricity supply and the quality management of electricity, load balance has been an important strategy for achieving high quality load management. Among many techniques for load management, direct load management has been actively studied and applied for increasing the efficiency of power facility and suppressing peak load. In Korea, the highest peak load is demanded in summer rather than in winter, and almost 50% of the peak load comes from cooling load. Currently, applicable systems are limited to air conditioners that have the cooling capacity less than 2kW. This paper describes the development of remote controlled air conditioners and the result of the field test of the new type air conditioner. The technical specification based on the test will be applied to the new model of the remote controlled air conditioner. The wide distribution of the air conditioners to the public will be helpful to control peak demand due to cooling load in summer time. Financial investment to generating, transmission, distribution facilities will be decreased from flatting the seasonal power load.

  • PDF

An Automatic Power Control Circuit suitable for High Speed Burst-mode optical transmitters (고속 버스트 모드 광 송신기에 적합한 자동 전력 제어 회로)

  • Ki, Hyeon-Cheol
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.11 s.353
    • /
    • pp.98-104
    • /
    • 2006
  • The conventional burst-mode APC(Automatic Power Control) circuit had an effective structure that was suitable for a low power consumption and a monolithic chip. However, as data rate was increased, it caused errors due to the effect of the zero density. In this paper, we invented a new structured peak-comparator which could compensate the unbalance of the injected currents using double gated MOS and MOS diode. And we proposed a new burst-mode APC adopting it. The new peak-comparator in the proposed APC was very robust to zero density variations maintaining the correct decision point of the current comparison at high data rate. It was also suitable for a low power consumption and a monolithic chip due to lack of large capacitors.

An optimization technique for simultaneous reduction of PAPR and out-of-band power in NC-OFDM-based cognitive radio systems

  • Kaliki, Sravan Kumar;Golla, Shiva Prasad;Kurukundu, Rama Naidu
    • ETRI Journal
    • /
    • v.43 no.1
    • /
    • pp.7-16
    • /
    • 2021
  • Noncontiguous orthogonal frequency division multiplexing (NC-OFDM)-based cognitive radio (CR) systems achieve highly efficient spectrum utilization by transmitting unlicensed users' data on subcarriers of licensed users' data when they are free. However, there are two disadvantages to the NC-OFDM system: out-of-band power (OBP) and a high peak-to-average power ratio (PAPR). OBP arises due to side lobes of an NC-OFDM signal in the frequency domain, and it interferes with the spectrum for unlicensed users. A high PAPR occurs due to the inverse fast Fourier transform (IFFT) block used in an NC-OFDM system, and it induces nonlinear effects in power amplifiers. In this study, we propose an algorithm called "Alternative Projections onto Convex and Non-Convex Sets" that reduces the OBP and PAPR simultaneously. The alternate projections are performed onto these sets to form an iteration, and it converges to the specified limits of in-band-power, peak amplitude, and OBP. Furthermore, simulations show that the bit error rate performance is not degraded while reducing OBP and PAPR.

The Study on the Field test and Operational Method of a Direct Load Control System for Air conditioner (에어컨부하 직접제어시스템 실증시험 및 운용방안에 관한 연구)

  • Gang, Won-Gu;Kim, Chung-Hwan;Kim, Myong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2825-2827
    • /
    • 2000
  • In electric power industry. load balance has been one of the most fundamental and important management goals. Therefore. the strategy to achieve high quality load management now includes load balance besides the stabilization of electricity supply and quality management of electricity. Amongst many techniques of load management. direct load management has been actively studied and utilized to increase power facility and peak load suppression. Higher peak load situation is appeared during summer than during winter in Korea. and approximately 20% of the peak load is due to the load for air-conditioning. To cope with this peak load problem during summer KEPCO is performing a research project to develop a system to remotely control air-conditioning load using wireless communication. Currently, applicable facilities are limited to small-scale air-conditioning facility that has less than 2KW power capacity. This paper described the 1st year of efforts made in the study.

  • PDF

A New SLM Method using Dummy Sequence Insertion far the PAPR Reduction of the OFDM Communication System (OFDM통신 시스템의 PAPR저감을 위한 Dummy Sequence를 삽입하는 새로운 SLM 기법)

  • 이재은;허근재;김상우;유흥균
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.4
    • /
    • pp.379-386
    • /
    • 2004
  • OFDM(orthogonal frequency division multiplexing) communications system is very attractive for the high data rate transmissionin the frequency selective fading channel. Since OFDM has high PAPR(peak-to-average power ratio), OFDM signal may be distorted by the nonlinear HPA(high power amplifier). In this paper, we propose an improved dummy sequence scheme for reducing the PAPR in OFDM communication system. This method inserts each different dummy sequence at the predefined sub-carriers fur PAPR reduction. After IFFT, the OFDM data signal with the lowest PAPR is selected to transmit. The complementary sequence is used as dummy sequence. So, it can cut down the computation time and quantity because it dose not require the peak value optimization for finding the phase rotation factor and the transmission of the side information about the rotation factor unlike the PTS method.

Grid-Connected Peak Load Compensation System Based on Lithium Polymer Battery Energy Storage System

  • Jung, Doo-Yong;Ji, Young-Hyok;Lee, Su-Won;Won, Chung-Yuen;Seo, Kwang-Duk;Jung, Yong-Chae
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.265-267
    • /
    • 2009
  • we proposed a grid connected peak load compensation system with high discharge current characteristics based on lithium polymer battery for development of the next generation power-station. The lithium polymer battery has faster discharge current characteristics than conventional battery, so that can compensate high active power demanded by load in a short time using the low capacity battery bank. Therefore, it is possible to control power leveling of grid by measuring storage energy of battery and active power which is needed from load. The validity of proposed system was verified through the simulation and experiment.

  • PDF