Characteristics of Residual Ozone Decomposition with Commercial Ozone Decomposition Catalyst (ODC) and Photo catalyst (상업용 오존촉매와 광촉매를 이용한 오존제거특성)

  • Byeon, Jeong-Hoon;Park, Jae-Hong;Hwang, Jung-Ho
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1255-1260
    • /
    • 2004
  • Decomposition of ozone at room temperature was investigated comparatively with commercial monolithic ozone decomposition catalyst (ODC, $MnO_2$) and monolithic photo catalyst ($TiO_2$). The effects of residence time, UV (ultraviolet) light dependence and ozone concentration on the conversion was presented. UV ray was irradiated using BLB (black light blue) lamp ($315{\sim}400$ nm), supplied with a constant intensity in the reactor. The concentration of ozone in the square-shape reactor can be controlled by combining the DBD (dielectric barrier discharge) reactor with an AC high voltage supply system. The catalytic performance, in presence of UV irradiation did not show significant changes for $MnO_2$ catalyst. $TiO_2$ catalyst was the different case, which showed higher decomposition activity in presence of UV irradiation. Deactivation of catalyst detected by real-time ozone monitor for 120 hours with a constant inlet ozone concentration.

  • PDF

A High Efficiency Ozone Generation Using a Electrode-edge Discharge and a Dielectric-Barrier Discharge (전극연면방전(電極沿面放電)과 유전체장벽방전(誘電體障壁放電)을 공용(共用)한 고효율(高效率) 오존발생(發生))

  • Choi, Jae-Gu;Moon, Jae-Duk
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1410-1412
    • /
    • 1995
  • A high efficiency ozone generation using both of a electrode-edge discharge and a dielectric-harrier discharge from a modified silent type ozone generator has been proposed and studied for small scale applications. It is found that the output ozone concentration of the proposed generator depended greatly upon the air gap spacing and the applied power frequency and voltage on the ozone generation. The ozone generator showed higher ozone concentration than the same size of the ceramic type surface ozone generator(Masuda type one). And, it is found that the generator had a potential to be used as an ozone generator for small scale applications.

  • PDF

The Analysis of Atmospheric Flow Field and Air Quality According to the High Level Ozone Case on Gwangyang Bay (광양만 권역에서의 고농도 오존 사례에 대한 기상 및 대기질 분석)

  • Choi, Hyun-Jung;Lee, Hwa-Woon;Leem, Heon-Ho;Song, Jae-Hwal
    • Journal of Environmental Science International
    • /
    • v.17 no.7
    • /
    • pp.743-753
    • /
    • 2008
  • Gwangyang Bay is often severely confronted by photochemical pollutants due to its location and dense emissions. It is located in a basin on the south coast of the Korean peninsula and is crossed by a remarkable cluster of hills and mountains of a small horizontal scale that forms a channel. Clearly, the air flow field has a great influence on the dispersion of air pollutants. The characteristics of the wind flow patterns have an important effect on the dispersion of pollutants emitted. In these situations, the distribution of the ozone concentration is extremely complicated because of the superposition of circulations of the air flow fields, especially in complex coastal region. In this study, we examined the distribution of the high level ozone on Gwangyang Bay particularly during the episode day (for 5 years). Among these days, A high level ozone was induced by the development of a sea/land breeze local circulation system, as well as by an anabatic/catabatic flow from the mountains and valley with weakening of the synoptic wind. High level ozone distribution pattern(6 types) on Gwangyang bay is analyzed and the comparison of each pattern reveals substantial localized differences in intensity and distribution of ozone concentration from the site coherence and UPA analysis of ozone concentration. The observed VOC concentration had much difference in concentrations and daily variations between Jungdong and Samil.

Meteorological Characteristics of High-Ozone Episode Days in Daegu, Korea (대구시의 고농도 오존 발생 일에 나타나는 기상학적 특성)

  • Son, Im-Young;Kim, Hee-Jong;Yoon, Ill-Hee
    • Journal of the Korean earth science society
    • /
    • v.23 no.5
    • /
    • pp.424-435
    • /
    • 2002
  • This study analyzes the surface ozone and meteorological data in Daegu for a period from 1997 to 1999. It also investigates the meteorological characteristics of high ozone episodes. For this study the high ozone episode has been defined as a daily maximum ozone concentration higher than 100ppb in at least one station among six air quality monitoring stations in Daegu, Korea. The frequency of episodes is 13 days. The frequency is the highest in May and September. The average value of daily maximum ozone concentration is 81.6ppb, and 8-hour average ozone concentration is 58.6ppb for the high episodes. This shows that ozone pollution is continuous and wide-ranging in Daegu. The daily maximum ozone concentration is positively correlated to solar radiation and daily maximum temperature, but negatively correlated to relative humidity, wind speed and cloud amount. The maximal correlation coefficient to solar radiation is 0.45. The differences between high ozone episode day's daily mean meteorological value and monthly mean value are +1.58hPa for sea level pressure, +3.45${\circ}$C for maximum temperature, -5.69% for relative humidity, -0.46ms$^{-1}$ for wind speed, -1.79 for cloud amount, and +3.97MJm$^{-2}$ for solar radiation, respectively. This shows that strong solar radiation, low wind speed and no precipitation between 0700${\sim}$1100LST are favorite conditions for high ozone episodes. It is related to the morning stagnant condition.

The Analysis of Spatial Distribution of Ozone in the Southern Coast of Korea using the Aircraft (2009, Summer) (항공기를 이용한 남해안 지역의 오존 공간분포 조사 (2009년, 여름철))

  • Seo, Seok-Jun;Kim, So-Young;Lee, Min-Do;Choi, Jin-Soo;Kim, Su-Yeon;Lee, Seok-Jo;Kim, Jeong-Soo;Lee, Gang-Woong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.1
    • /
    • pp.12-21
    • /
    • 2012
  • The purpose of this study is to understand distribution of ozone concentration in the south coastal region of Korea by evaluating ozone spatial distribution in the upper air using aircraft. Sampling was carried out from May to August in 2009. The average concentration of ozone in the upper air was ranged from 32.3~90.8 ppb with its maximum concentration of 132 ppb. When it comes to the spatial distribution of ozone, ambient concentration was high in the air, 1,000 m and 500 m above the southern sea near the Gwangyang Bay area and emission sources, respectively. Daily mean concentration of NOy was 6.7~24.2 ppb and that of CO was 0.152~0.487 ppm. In addition, the concentration was appeared to be relatively high in the upper air of industrial regions and the southern seas. Meanwhile, the concentration of both $NO_y$ and CO was high in the upper air of the emission sources regardless of latitude. As for PAN, its daily mean concentration ranged between 0.1 and 0.6 ppb with overall mean concentration of 0.2 ppb. The average concentration of VOCs was 48 ppb, and the concentration of toluene and m,p-Xylene were higher than other components.

Neuro-Fuzzy Approaches to Ozone Prediction System (뉴로-퍼지 기법에 의한 오존농도 예측모델)

  • 김태헌;김성신;김인택;이종범;김신도;김용국
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.10 no.6
    • /
    • pp.616-628
    • /
    • 2000
  • In this paper, we present the modeling of the ozone prediction system using Neuro-Fuzzy approaches. The mechanism of ozone concentration is highly complex, nonlinear, and nonstationary, the modeling of ozone prediction system has many problems and the results of prediction is not a good performance so far. The Dynamic Polynomial Neural Network(DPNN) which employs a typical algorithm of GMDH(Group Method of Data Handling) is a useful method for data analysis, identification of nonlinear complex system, and prediction of a dynamical system. The structure of the final model is compact and the computation speed to produce an output is faster than other modeling methods. In addition to DPNN, this paper also includes a Fuzzy Logic Method for modeling of ozone prediction system. The results of each modeling method and the performance of ozone prediction are presented. The proposed method shows that the prediction to the ozone concentration based upon Neuro-Fuzzy approaches gives us a good performance for ozone prediction in high and low ozone concentration with the ability of superior data approximation and self organization.

  • PDF

Design Optimization of an Ozone Contactor Using Ozone Contactor Model (OCM) Software

  • Kim, Doo-Il;Lee, Chae-Young;Joe, Woo-Hyeun;Lee, Seock-Heon
    • Environmental Engineering Research
    • /
    • v.14 no.4
    • /
    • pp.244-249
    • /
    • 2009
  • Designing an ozone contactor is complicated because the residual ozone, log C. parvum inactivation, and bromate formation should be optimized with fluctuating water quality. OCM software was developed to assist a plant designer or an operator to fulfill the sophisticated optimization required in the design or operation of a new or an existing plant. In this article, numerical simulations were carried out using the OCM software for the design of a new ozone contactor under diverse design factors (i.e., three pHs, three temperatures, low and high dispersion numbers, and four and ten cells with complete mixing) with kinetic parameters obtained from the sand-filter effluent of a water treatment plant treating water from the Paldang impoundment. The results of the simulation suggested that a high residual ozone concentration at low pH and low temperature would be challenging, and PFR-like hydrodynamics could lower the residual ozone concentration. The inactivation of C. parvum oocysts increased at a lower pH. A lower dispersion number and more cell division increased the inactivation efficiency. Bromate was instantaneously formed during the initial ozonation stage. The effluent concentration was much lower than the regulatory levels imposed by the USEPA because of the low bromide level in raw water.

A New Small Size Digital Optical Ozone Monitor Using CCD Array as a UV Detector (UV 감지기로서 CCD어레이를 사용한 소형 디지털 광 오존모니터)

  • Chung, Wan-Young;Lee, Seung-Chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.1
    • /
    • pp.158-163
    • /
    • 2008
  • Ozone monitor based on UV techniques has been widely used due to their signal stability. The high concentration ozone monitor for real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source and a photo multiplier tube as UV detector. The structure could be very useful for low price high concentration ozone monitor and showed good linearity to ozone in the concentration range between 0.05 and 2wt%. For accurate ambient ozone monitoring, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector. The optical signal form the CCD array was converted to digital signal, and the digital signal was displayed on screen using PC interface. The developed system showed good linearity and sensitivity in relatively low measuring range between 10ppm and 10,000ppm, and showed some feasibility of hish resolution ozone monitor using CCD array as a photodetecor.

Decoloring Effect of Viscose Rayon by Using Vapor Type Ozone Processing (오존 기상처리방법에 의한 비스코스 레이온의 탈색효과)

  • Kim, Gyoung-A;Lee, Mun-Soo
    • The Journal of Natural Sciences
    • /
    • v.10 no.1
    • /
    • pp.103-109
    • /
    • 1998
  • We studied on the decoloring effect of viscose rayon by vapor type ozone processing using ozone's strong oxidation. When ozone is generated, it becomes high concentration in vapor state, but in the insolving process with water, there are a lot of lose of ozone. As a result, a study using ozone in vapor-high concentration state is needed. So, in this paper, vapor type ozone processing is used unlike previous ozone treatment method-an aqueous solution method-to get a good effect from shortening the processing time. When vapor type ozone processing was directly treated to fabrics, high concentration ozone was generated then in a short time oxidized a dye existed in fabrics and finally decolored it. As vapor type ozone did not directly response to an organic dye, viscose rayon's decolorization was to be studied by changing pick up ratio(60%, 50%, 40%, 30%, 20%) using water as a medium. When pick up ratio of water was 40%, fabric's whiteness was improved but tensile strength and elongation were reduced. So 60 minutes was assumed as the most adjust time to minimize the reduction of fabric's tensile strength and elongation moreover of maximize the improvement of whiteness.

  • PDF

Prediction of Ozone Concentration by Multiple Regression Analysis in Daegu area (다중회귀분석을 통한 대구지역 오존농도 예측)

  • 최성우;최상기;도상현
    • Journal of Environmental Science International
    • /
    • v.11 no.7
    • /
    • pp.687-696
    • /
    • 2002
  • Air quality monitoring data and meteorology data which had collected from 1995. 1. to 1999. 2. in six areas of Daegu, Manchondong, Bokhyundong, Deamyungdong, Samdukdong, Leehyundong and Nowondong, were investigated to determine the distribution and characteristic of ozone. A equation of multiple regression was suggested after time series analysis of contribution factor and meteorology factor were investigated during the day which had high concentration of ozone. The results show the following; First, 63.6% of high ozone concentration days, more than 60 ppb of ozone concentration, were in May, June and September. The percentage of each area showed that; Manchondong 14.4%, Bokhyundong 15.4%, Deamyungdong 15.6%, Samdukdong 15.6%, Leehyundong 17.3% and Nowondong 21.6%. Second, correlation coefficients of ozone, $SO_2$, TSP, $NO_2$ and CO showed negative relationship; the results were respectively -0.229, -0.074, -0.387, -0.190(p<0.01), and humidity were -0.677. but temperature, amount of radiation and wind speed had positive relationship; the results were respectively 0.515, 0.509, 0.400(p<0.01). Third, $R^2$ of equation of multiple regression at each area showed that; Nowondong 45.4%, Lee hyundong 77.9%, Samdukdong 69.9%, Daemyungdong 78.8%, Manchondong 88.6%, Bokhyundong 77.6%. Including 1 hour prior ozone concentration, $R^2$ of each area was significantly increased; Nowondong 75.2%, Leehyundong 89.3%, Samdukdong 86.4%, Daemyungdong 88.6%, Manchondong 88.6%, Bokhyundong 88.0%. Using equation of multiple regression, There were some different $R^2$ between predicted value and observed value; Nowondong 48%, Leehyundong 77.5%, Samdukdong 58%, Daemyungdong 73.4%, Manchondong 77.7%, Bokhyundong 75.1%. $R^2$ of model including 1 hour prior ozone concentration was higher than equation of current day; Nowondong 82.5%, Leehyundong 88.3%, Samdukdong 80.7%, Daemyungdong 82.4%, Manchondong 87.6%, Bokhyundong 88.5%.