• Title/Summary/Keyword: High ozone concentration

Search Result 294, Processing Time 0.028 seconds

Verification of Mobile Emission for CMAQ using an Observation-based Approach in Seoul Metropolitan Area (수도권 지역에서 대기질 측정망 자료를 이용한 광화학모델의 이동오염원 배출량 검증)

  • Lee, Yong-Mi;Lee, Hyun-Ju;Yoo, Chul;Song, Jeong-Hui;Kim, Ji-Young;Hong, Ji-Hyung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.5
    • /
    • pp.369-381
    • /
    • 2009
  • The objective of this study was to simulate surface air pollutants and to examine reliability of mobile emission for CMAQ system using an observation-based approach in the Seoul Metropolitan Area. Accurate assessment of emissions from mobile source is one of the most debatable parts in the entire emissions inventory process. For this study, we evaluated the official emission inventories of Volatile Organic Compounds (VOCs) and nitrogen oxides ($NO_x$) using an observation-based approach. In this paper, we achieved VOCs/CO and $NO_x$/CO ratios derived from ambient measurements taken from June to August of 2005 in early morning (07:00~08:00). And we compared them with those derived from the emission inventory. Based on these ratios and on the assumption that official inventory of CO emissions is reasonably accurate, mobile emissions of $NO_x$ seem to be slightly overestimated and VOCs emissions significantly underestimated. The results of simulations using modified emission of mobile source were in closer agreement with the observation results except NO. Predicted NO values based on revised $NO_x$ emissions were considerably lower than the observed values. Using modified emission inventories brings the modeled values into closer agreement with observed ozone levels in Seoul. Especially in case of CO, $NO_x$ and VOCs emission, the modified values were suitable for simulating ozone levels in Seoul and Gyeonggi. However, ozone values predicted using the modified emissions were higher than the observed and predicted values based on original emissions. According to the 95 percentile ozone concentrations, emission revised by CO, $NO_x$ and VOCs from mobile source was the best for predicting high concentration.

Test Results of Pulsed Power Supply for Nonthermal Plasma Process (저온 플라즈마 공정용 펄스발생 전원장치의 성능시험)

  • Jang, S.D.;Byun, Y.C.;Cho, M.H.;Shin, D.N.
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1574-1575
    • /
    • 2011
  • The application of a pulsed power system is being extended to an environmental and industrial field. The non-destructive gaseous pollutants from industrial plants such as power generation plants and incinerators can be processed by applying high voltage pulses with a fast rising time (a few nanoseconds) and short duration (nano to microseconds) in a pulsed corona discharge reactor. The pulsed plasma generator with a triggered switch has been developed. Its corona current in load can be adjusted by applied voltage and repetition rate. We investigated the performance of the pulsed plasma generator by analyzing the concentration of ozone in small reactor. This paper describes the electrical characteristics of the pulse generator with a voltage of 30 kV at repetition rate of 50 PPS. In addition, we briefly discuss a configuration of the system and initial test results.

  • PDF

Characteristic improvement of the forward type high voltage pulse power supply for Lamp Type Ozonizer (램프형 오존발생기용 Foward형 고압 펄스전원장치의 특성개선)

  • Kim, Kyung-Sik;Won, Jae-Sun;Kim, Dong-Hee;Ro, Chae-Gyun;Nam, Seung-Sik;Sim, Kwang-Yeal
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1117-1119
    • /
    • 2001
  • This paper describes the forward type pulse power supply using a Power-MOSFET in the view of commercialization. The principle of basic operating and the operating characteristics of the forward type pulse power supply are estimated by the switching frequency, coupling factor and duty ratio. It is shown that theoretical and experimental results are in good agreement by comparing simulation and experimental results when a lamp type ozonizer can be used as a load. Also, experimental results indicate that the discharge and ozone concentration characteristics of the manufactured pulse power supply is more improved compare to the conventional pulse power supply[5]. This proposed supply show that it can be practically used as a pulse power supply in various environment improvement facilities.

  • PDF

A Characteristic analysis of Wind Direction and Wind Speed for the High Ozone Concentration (고농도 오존현상에 영향을 미치는 풍향ㆍ풍속의 특징분석)

  • 이화운;정우식;현명숙
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.403-404
    • /
    • 2001
  • 전구물질에 의해 생성되는 이차오염물질인 $O_3$은 기상장의 영향으로 인한 두가지 형태의 수송에 의해 방출원이 아닌 다른 지역에서 오염물질의 고농도 현상을 야기할 수 있다. 첫 번째 형태의 수송은 종관장이 강한 날에 발생할 수 있는 것으로 방출원에서 타 지역으로 경도풍에 의한 오염물질의 장거리 수송이다(Cox et al.,1975 : Apling et al.,1977). 두 번째 형태는 종관장이 약하여 국지순환계가 발달하고 연안지역과 내륙지역의 기온차이에 의해 발생하는 내륙지역의 열적 저기압의 형성과 이에 따른 연안지역에서 내륙지역으로의 오염물질의 수송이다(Kurita and Ueda, 1990). (중략)

  • PDF

A Study on the Color Removal in the Secondary Effluent (하수처리장 방류수 색도 제거에 관한 연구)

  • 이면주;정영도;진준하
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.3
    • /
    • pp.30-36
    • /
    • 1998
  • A study on the color removal by irradiation of ${\gamma}-ray$ was carried out to reclaim the secondary effluent for the purpose of industrial water. Coagulation, ozone and ion exchange methods were compared. It could know that irradiation method was the most effective in color removal. The color was removed by 87.5% at 0.5 Mrad and it was increase with dose. High removal efficiency could be obtained in low pH and low concentration of $CO3^{-2}$. This process can be applied to the treatment of secondary effluent and is considered to be one of the most useful tertiary treatment.

  • PDF

A Study on the Relationship of Air Pollution and Meteorological Factors : Focusing at Kwanghwamun in Seoul (대기오염농도와 기상인자의 관련성 연구: 서울 광화문지점을 중심으로)

  • 신찬기;한진석;김윤신
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.8 no.4
    • /
    • pp.213-220
    • /
    • 1992
  • Simple correlation analysis, factor analysis, and multi-variate analysis have been performed to analyze the relationship between air pollution and meteorological factors for air pollution and meteorological data measured at Kwanghwamun in Seoul during the period of one year(January 1990 $\sim$ December 1990). As a result of simple correlation and factor analysis, $SO_2$, TSP and CO concentrations have shown high negative correlation with temperature and among these indicating that these are related with pollutant emission trend based upon heating fuel usage. Ozone has a good corrleation with solar radiation and relative humidity to have a closed relation with $O_3$ generation reaction mechanism. The result of multi-variate correlation analysis shows that the concentration of $SO_2$ and CO are adequate for correlation model with ambient temperature and wind speed and $O_3$ concentrations are adequate for that with solar radiation and wind speed. $SO_2$ and CO levels are considered to be affected first of all by heating fuel usage as a emssion source and wind speed as a dispersion effect. The $SO_2$ concentration in the condition that the temperature fall below zero is explained by multilicative model with wind speed, only one variable.

  • PDF

A Study on the Relationship of Air Pollution and Meteorologic Factors in a Specific Site (서울 일부지점의 대기오염 농도와 기상인자의 관련성 연구)

  • 신찬기;김윤신
    • Journal of environmental and Sanitary engineering
    • /
    • v.7 no.2
    • /
    • pp.141-152
    • /
    • 1992
  • Simple correlation analysis, factor analysis, and multi-verite analysis have been performed to analyze the relationship between air pollution and meteorological factors for air pollution and meteorological data measured at Kwanghwamun in Seoul during the period of one year (January 1990" December 1990). As a result of simple correlation and factor analysis, $SO_2$, TSP and CO concentrations have shown high negative correlation with temperature and among these indicating that these are related with pollutants emission trend based upon heating fuel usage. Ozone has a good correlation with solar radiation and relative humidity to have a closed relation with $0_3$ generation reaction mechanism. The result of multi-variate correlation analysis shows that the concentration of $SO_2$ and CO are adequate for correlation model with ambient temperature and wind speed and 0$_{3}$ concentrations are adequate for that with solar radiation and wind speed. $SO_2$ and CO levels are considered to be affected first of all by heating fuel usage as a emission source and wind speed as a dispersion effect. The $SO_2$ concentration in the condition that the temperature fall below zero is explained by multiplicative model with wind speed, only one variable.

  • PDF

Relation with Activity of Road Mobile Source and Roadside Nitrogen Oxide Concentration (도로이동오염원의 활동도와 도로변 질소산화물 농도의 관계)

  • Kim, Jin Sik;Choi, Yun Ju;Lee, Kyoung Bin;Kim, Shin Do
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.1
    • /
    • pp.9-20
    • /
    • 2016
  • Ozone has been a problem in big cities. That is secondary air pollutant produced by nitrogen oxide and VOCs in the atmosphere. In order to solve this, the first to be the analysis of the $NO_x$ and VOCs. The main source of nitrogen oxide is the road mobile. Industrial sources in Seoul are particularly low, and mobile traffics on roads are large, so 45% of total $NO_x$ are estimated that road mobile emissions in Seoul. Thus, it is necessary to clarify the relation with the activity of road mobile source and $NO_x$ concentration. In this study, we analyzed the 4 locations with roadside automatic monitoring systems in their center. The V.K.T. calculating areas are set in circles with 50 meter spacing, 50 meter to 500 meter from their center. We assumed the total V.K.T. in the set radius affect the $NO_x$ concentration in the center. We used the hourly $NO_x$ concentrations data for the 4 observation points in July for the interference of the other sources are minimized. We used the intersection traffic survey data of all direction for construction of the V.K.T. data, the mobile activities on the roads. ArcGIS application was used for calculating the length of roads in the set radius. The V.K.T. data are multiplied by segment traffic volume and length of roads. As a result, the $NO_x$ concentration can be expressed as linear function formula for V.K.T. with high predictive power. Moreover we separated background concentration and concentrations due to road mobile source. These results can be used for forecasting the effect of traffic demand management plan.

Prediction of High Level Ozone Concentration in Seoul by Using Multivariate Statistical Analyses (다변량 통계분석을 이용한 서울시 고농도 오존의 예측에 관한 연구)

  • 허정숙;김동술
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.207-215
    • /
    • 1993
  • In order to statistically predict $O_3$ levels in Seoul, the study used the TMS (telemeted air monitoring system) data from the Department of Environment, which have monitored at 20 sites in 1989 and 1990. Each data in each site was characterized by 6 major criteria pollutants ($SO_2, TSP, CO, NO_2, THC, and O_3$) and 2 meteorological parameters, such as wind speed and wind direction. To select proper variables and to determine each pollutant's behavior, univariate statistical analyses were extensively studied in the beginning, and then various applied statistical techniques like cluster analysis, regression analysis, and expert system have been intensively examined. For the initial study of high level $O_3$ prediction, the raw data set in each site was separated into 2 group based on 60 ppb $O_3$ level. A hierarchical cluster analysis was applied to classify the group based on 60 ppb $O_3$ into small calsses. Each class in each site has its own pattern. Next, multiple regression for each class was repeatedly applied to determine an $O_3$ prediction submodel and to determine outliers in each class based on a certain level of standardized redisual. Thus, a prediction submodel for each homogeneous class could be obtained. The study was extended to model $O_3$ prediction for both on-time basis and 1-hr after basis. Finally, an expect system was used to build a unified classification rule based on examples of the homogenous classes for all of sites. Thus, a concept of high level $O_3$ prediction model was developed for one of $O_3$ alert systems.

  • PDF

Analysis of Chemical and Meteorological Effects on the Concentration Difference of Photochemical Air Pollutants between Coastal and Inland Regions in Busan (부산시 해안 및 내륙지역에서 광화학 오염물질의 농도 차이에 영향을 주는 화학 및 기상조건 분석)

  • Sang, Sang-Keun;Shon, Zang-Ho
    • Journal of Environmental Science International
    • /
    • v.17 no.10
    • /
    • pp.1169-1182
    • /
    • 2008
  • The chemical and meteorological effects on the concentration variations of air pollutants ($O_3$ and its precursors) were evaluated based on ground observation data in coastal and inland regions, Busan during springs and summers of 2005-2006. For the purpose of this study, study areas were classified into 5 categories: coastal area (CA), industrial area (IA), downtown area (DA), residential area (RA), and suburban area (SA). Two sites of Dongsam (DS) and Yeonsan (YS) were selected for the comparison purpose between the coastal and inland regions. $O_3$ concentrations in CA and SA were observed to be highest during spring (e.g., 40 ppb), whereas those in DA and RA were relatively low during summer (e.g., $22\sim24$ ppb). It was found that $O_3$ concentrations in IA were not significantly high although high VOCs (especially toluene of about 40 ppb) and $NO_x$ ($\geq$ 35 ppb) were observed. On the other hand, the concentration levels of $O_3$ and $PM_{10}$ at the DS site were significantly higher than those at the YS site, but $NO_x$ was slightly lower than that at the YS site. This might be caused by the photochemical activity and meteorological conditions (e.g., sea-land breeze and atmospheric stagnance). When maximum $O_3$ (an index of photochemical activity) exceeds 100 ppb, the contribution of secondary $PM_{10}\;((PM_{10})_{SEC})$ to total observed $PM_{10}$ concentrations was estimated up to 32% and 17% at the DS and YS sites, respectively. In addition, the diurnal variations of $(PM_{10})_{SEC}$ at the DS site were similar to those of $O_3$ regardless of season, which suggests that they are mostly secondary $PM_{10}$ produced from photochemical reactions.