• 제목/요약/키워드: High ozone

검색결과 664건 처리시간 0.035초

단결정 형성을 위한 열역학 분석 (Analysis of Thermodynamics for Single Crystal Formation)

  • 천민우;양승호;박용필
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 학술대회 및 기술세미나 논문집 디스플레이 광소자
    • /
    • pp.70-73
    • /
    • 2006
  • High quality $Bi_2Sr_2Ca_nCu_{n+1}O_x$ superconducting thin films fabricated by using the evaporation method at various substrate temperatures, $T_{sub}$, and ozone gas pressures, $pO_3$. The correlation diagrams of the $Bi_2Sr_2Ca_nCu_{n+1}O_x$ phases with $T_{sub}$ and $pO_3$ are established in the 2212 arid 2223 compositional films. In spite of 2212 compositional sputtering, Bi2201 and Bi2223 as well as Bi2212 phases come out as stable phases depending on $T_{sub}$ and $pO_3$. From these results, the thermodynamic evaluation of ${\Delta}H$ and ${\Delta}S$, which are related with Gibbs' free energy change for single Bi2212 or Bi2223 phase, was performed.

  • PDF

냉매 R717과 R22를 작동유체로 이용한 냉동장치의 성능특성에 관한 연구 (The Study on Performance Characteristics in Refrigeration System using R717 and R22 as working fluid)

  • 김진현;김재근;김종길;김양현;홍석주;하옥남
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.495-500
    • /
    • 2006
  • Nowadays HCFCs refrigerant are restricted because it cause depletion of ozone layer. However, natural gases such as ammonia as an organic compound, propane and propylene as hydrocarbon are easy and cheap to obtain as well as environmental. Accordingly, this experiment apply the $NH_3$ and R22 to study the performance characteristic from the superheat control and compare the energy efficiency of two refrigerants from the high performance. The condensing pressure of refrigeration system is increased from 15bar to 16bar and degree of superheat is increased from 0 to $10^{\circ}C$ at each condensing pressure. As the result of experiment, when comparing the each COP, we knew the $NH_3$ is suitable as the alternative refrigerant of the R22.

  • PDF

R-134a와 R-152a 냉매를 이용한 자동차용 에어컨 시스템의 성능에 관한 실험적 연구 (An Experimental Study on Performance of Automotive Air conditioning System by using R-134a and R-152a)

  • 김종수;이대웅;유성연
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1225-1231
    • /
    • 2006
  • Recently, as the climate of temperature change has happened worldwide, To solve this problem, Kyoto protocol was taken to regulate global warming on Feb. 2005 and each country is making efforts to prevent global warming. In the automotive industry, R-134a refrigerant is widely used most these days because it has zero ODP(Ozone Depletion Potential). But R-134a GWP(Global Warming Potential) is so high. Therefore, replacement refrigerant desperately is needed as a alternative refrigerant. So, R-l52a is considered as one of the alternative refrigerants due to zero ODP and lower GWP against as required on Europe Committee. In this paper, performance of the air conditioning system between R-134a and R-152a is investigated experimentally. In the bench level, cooling capacity, condensing capacity, COP of automotive air conditioning system are ovaluated by means of air velocity entering the condenser and compressor revolution speed with optimized charge refrigerant quantity. Result of this study, R-152a refrigerant shows the possibility as alternative refrigerant of current R-134a in automotive air conditioning system.

  • PDF

시뮬링크를 이용한 플래시메모리 저장장치 성능 모델링 (Performane Modeling of Flash Memory Storage Systems Using Simulink)

  • 민항준;박정수;이주일;민상렬;김강희
    • 대한임베디드공학회논문지
    • /
    • 제6권5호
    • /
    • pp.263-272
    • /
    • 2011
  • The complexity of flash memory based storage systems is high due to diverse host interfaces and other design choices such as mapping granularity, flash memory controller execution models and so on. Thus, it is possible that the actual performance after implementation is not consistent with the target performance. This paper demonstrates that the performance prediction of flash memory based storage systems is possible through performance modeling that takes into account various design parameters. In the performance modeling, the FTL, which is the core element of flash memory based storage systems, is modeled as a set of (copy-on-write) logs and their interactions. Also, the flash memory controller is modeled based on the classification proposed in the design of the Ozone flash controller. In this study, the performance model has been implemented using Simulink and experimental results are presented and analyzed.

Estimation of HCHO Column Using a Multiple Regression Method with OMI and MODIS Data

  • Hong, Hyunkee;Yang, Jiwon;Kang, Hyeongwoo;Kim, Daewon;Lee, Hanlim
    • 대한원격탐사학회지
    • /
    • 제35권4호
    • /
    • pp.503-516
    • /
    • 2019
  • We have estimated the vertical column density (VCD) of formaldehyde (HCHO) on a global scale using a multiple linear regression method (MRM) with Ozone Monitoring Instrument (OMI) and Moderate-Resolution Imaging Spectroradiometer (MODIS) data. HCHO VCDs were estimated in regions of biogenic, pyrogenic, and anthropogenic emissions using independent variables, including $NO_2$ VCD, land surface temperature (LST), an enhanced vegetation index (EVI), and the mean fire radiative power (MFRP), which are strongly correlated with HCHO. To evaluate the HCHO estimates obtained using the MRM, we compared estimates of HCHO VCD data measured by OMI ($HCHO_{OMI}$) with those estimated by multiple linear regression equations (MRE) ($HCHO_{MRE}$). Good MRM performances were found, having the average statistical values (R = 0.91, slope = 1.03, mean bias = $-0.12{\times}10^{15}molecules\;cm^{-2}$, percent difference = 11.27%) between $HCHO_{MRE}$ and $HCHO_{OMI}$ in our study regions where high HCHO levels are present. Our results demonstrate that the MRM can be a useful tool for estimating atmospheric HCHO levels.

3구 노즐을 이용한 플라즈마 가스 용존율 향상을 위한 플라즈마 공정의 최적화 (Optimization of Plasma Process to Improve Plasma Gas Dissolution Rate using Three-neck Nozzle)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제30권5호
    • /
    • pp.399-406
    • /
    • 2021
  • The dissolution of ionized gas in dielectric barrier plasma, similar to the principle of ozone generation, is a major performance-affecting factor. In this study, the plasma gas dissolving performance of a gas mixing-circulation plasma process was evaluated using an experimental design methodology. The plasma reaction is a function of four parameters [electric current (X1), gas flow rate (X2), liquid flow rate (X3) and reaction time (X4)] modeled by the Box-Behnken design. RNO (N, N-Dimethyl-4-nitrosoaniline), an indictor of OH radical formation, was evaluated using a quadratic response surface model. The model prediction equation derived for RNO degradation was shown as a second-order polynomial. By pooling the terms with poor explanatory power as error terms and performing ANOVA, results showed high significance, with an adjusted R2 value of 0.9386; this indicate that the model adequately satisfies the polynomial fit. For the RNO degradation, the measured value and the predicted values by the model equation agreed relatively well. The optimum current, gas flow rate, liquid flow rate and reaction time were obtained for the highest desirability for RNO degradation at 0.21 A, 2.65 L/min, 0.75 L/min and 6.5 min, respectively.

Correlation Analysis of Atmospheric Pollutants and Meteorological Factors Based on Environmental Big Data

  • Chao, Chen;Min, Byung-Won
    • International Journal of Contents
    • /
    • 제18권1호
    • /
    • pp.17-26
    • /
    • 2022
  • With the acceleration of urbanization and industrialization, air pollution has become increasingly serious, and the pollution control situation is not optimistic. Climate change has become a major global challenge faced by mankind. To actively respond to climate change, China has proposed carbon peak and carbon neutral goals. However, atmospheric pollutants and meteorological factors that affect air quality are complex and changeable, and the complex relationship and correlation between them must be further clarified. This paper uses China's 2013-2018 high-resolution air pollution reanalysis open data set, as well as statistical methods of the Pearson Correlation Coefficient (PCC) to calculate and visualize the design and analysis of environmental monitoring big data, which is intuitive and it quickly demonstrated the correlation between pollutants and meteorological factors in the temporal and spatial sequence, and provided convenience for environmental management departments to use air quality routine monitoring data to enable dynamic decision-making, and promote global climate governance. The experimental results show that, apart from ozone, which is negatively correlated, the other pollutants are positively correlated; meteorological factors have a greater impact on pollutants, temperature and pollutants are negatively correlated, air pressure is positively correlated, and the correlation between humidity is insignificant. The wind speed has a significant negative correlation with the six pollutants, which has a greater impact on the diffusion of pollutants.

지상원격측정 MAX-DOAS 시스템과 위성 OMI센서로 서울에서 산출된 이산화질소 층적분농도의 비교연구 (Comparison of Nitrogen Dioxide Retrieved by MAX-DOAS and OMI measurements in Seoul)

  • 이한림
    • 대한원격탐사학회지
    • /
    • 제29권2호
    • /
    • pp.235-241
    • /
    • 2013
  • 본 연구에서는 2007년과 2008년 봄 기간 중 동북아 지역의 주요 메가시티 중 하나인 서울에서 Multi-Axis Differential Optical Absorption Spectroscopy(MAX-DOAS) 관측을 처음으로 수행하고, 측정된 스펙트럼의 차등흡수분광 분석을 통하여 이산화질소의 수직층적분농도를 산출 하였다. MAX-DOAS로부터 산출된 값들과 Ozone Monitoring Instrument(OMI) 위성센서로부터 산출된 서울지역의 대류권 이산화질소 산출물과의 비교를 통하여 OMI로부터 산출된 이산화질소 수직층적분농도의 상대적 정확성 규명을 수행하였다. MAX-DOAS로부터 산출된 이산화질소는 $1.0{\times}10^{15}molec{\cdot}cm^{-2}$에서 $6.0{\times}10^{16}molec{\cdot}cm^{-2}$ 정도 분포로 보였으며, OMI의 대류권 수직층적분농도는 $1.0{\times}10^{15}molec{\cdot}cm^{-2}$에서 $7.0{\times}10^{16}molec{\cdot}cm^{-2}$ 정도 분포로 보였다. 관측전체기간인 6개월 동안 두 관측결과의 상관관계를 보여주는 상관계수(R)는 0.73으로 비교적 양호한 상관 관계를 보였다. 구름이 없는 기간 동안에는 상관계수가 0.85로 두 관측결과의 높은 상관관계는 확인 할 수 있었다. 두 센서의 산출알고리즘 모두 구름이 있을 경우 대기질량인자의 계산에 있어서 높은 불확실성으로 인해 이산화질소농도의 산출오차가 높은 것으로 판단된다.

산악연안지역에서 내부중력파와 해륙풍순환 영향하의 대기오염농도 (Atmospheric Pollutant Concentrations under the Influences of Internal Gravity Wave and Sea-Land Breeze Circulations in the Mountainous Coastal Regions)

  • Hyo Choi;Joon Choi
    • International Union of Geodesy and Geophysics Korean Journal of Geophysical Research
    • /
    • 제23권1호
    • /
    • pp.18-33
    • /
    • 1995
  • 동쪽 연안지역에서 큰 경사를 갖인 산맥위를 흘러가는 종관규모의 서풍하에서 내부 중력파와 같은 강한 하강폭풍이 산의 후면에서 발생되어 진다. 주간에 해양에서 내륙으로 향하는 중규모의 열적 강화에 의해 유도되는 해풍순환이 동쪽으로 향하는 내부중력파에 기인하여 연안의 앞바다까지만 국한된다. 따라서 연안해 근처의 표층풍은 외해나 내륙의 위치에서보다 상대적으로 더 약하다. 명백하게 서풍의 내부중력파순환파 해면 근처에서 동풍 및 상층에서 서풍을 갖는 해풍순환과 같은 두개의 상이한 종류의 대기순환이 뚜렷하게 나타났다. 이런 상황에서 강릉시에서의 대기오염물질은 반대 방향의 두개의 상이한 순환에 의해 갇히게 되고 부유분진과 오존의 고농도가 초래되었다. 야간에 육지에서 연안해로 향하는 중규모의 육풍은 기존의 동쪽으로 향하는 하강풍과 협력하여 연안지역에서 서풍의 더욱 강화를 유도할 수 있었다. 산쪽에서 연안해로 향하여 부는 강한 표층풍에 의해 조절되는 부유분진의 농도는 추간의 경우보다 야간에 비교적 더 높았으며, 상층대기로 부터 지표면으로 오존의 하양수송에 기인하여 오존의 농도가 주간보다 야간에 매우 높았다. 결과로 바람폭풍하의 산악연안지역에서 대기오염농도는 바람푹풍 전.후보다 더 높았다.

  • PDF

한강수계 고도정수처리 공정에서의 유기물과 맛·냄새의 제거특성 (Removal Characteristics of Natural Organic Matter and Taste and Odor by Advanced Water Treatment Process around the Han River Water Supply System)

  • 임재림;이경혁;김성수;채선하
    • 상하수도학회지
    • /
    • 제21권1호
    • /
    • pp.13-25
    • /
    • 2007
  • The water treatment plants in Seoul Metropolitan Area, which are under Korea Water Resources Corporation(KOWACO)'s management, take water from Paldang Reservoir in Han River System for drinking water supply. There are taste and odor (T&O) problems in the finished water because the conventional treatment processes do not effectively remove the T&O compounds. As part of countermeasures for taste and odor control, KOWACO is planning to introduce advanced water treatment process such as ozone and GAC in near future. This study evaluated the removal characteristics of T&O and dissolved organic matter (DOM) to find design and operation parameters of advanced water treatment processes in a pilot-scale treatment plant. The GAC adsorption capacity for DOC in the two GAC system (GAC and $O_3$-GAC) at an EBCT of 14min was mostly exhausted after 9months. The differency of the removal efficiency of DOC between $O_3$-GAC and GAC increased with increasing operation time because the bioactivity in $O_3$-GAC process was enhanced by post-ozone process. Removal by conventional treatment was unable to reach the target TON(threshold odor number) of 3 but GAC systems at an EBCT(empty bed contact time) of 14 min were able to archive the target with few exception. During the high T&O episodes, PAC as a pretreatment together with GAC could be useful option for T&O control. However, substantial TON removal continued for more than two year (> 90,000 bed volumes). At the spiking of less concentration 26 to 61 ng/L in the influent of GAC systems, GAC absorber and $O_3$-GAC processes could meet the treatment target. The better spike control after 12 and 19 months of operation compared to that after 7 months of operation is a strong indication of biological control. The results presented in this study had shown that $O_3$-GAC process was found to be more effective for T&O control than GAC process. And the main removal mechanism in GAC systems were adsorption capacity and biodegradation.