• 제목/요약/키워드: High order spectrum analysis

검색결과 150건 처리시간 0.021초

The applicability study and validation of TULIP code for full energy range spectrum

  • Wenjie Chen;Xianan Du;Rong Wang;Youqi Zheng;Yongping Wang;Hongchun Wu
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4518-4526
    • /
    • 2023
  • NECP-SARAX is a neutronics analysis code system for advanced reactor developed by Nuclear Engineering Computational Physics Laboratory of Xi'an Jiaotong University. In past few years, improvements have been implemented in TULIP code which is the cross-section generation module of NECP-SARAX, including the treatment of resonance interface, considering the self-shielding effect in non-resonance energy range, hyperfine group method and nuclear library with thermal scattering law. Previous studies show that NECP-SARAX has high performance in both fast and thermal spectrum system analysis. The accuracy of TULIP code in fast and thermal spectrum system analysis is demonstrated preliminarily. However, a systematic verification and validation is still necessary. In order to validate the applicability of TULIP code for full energy range, 147 fast spectrum critical experiment benchmarks and 170 thermal spectrum critical experiment benchmarks were selected from ICSBEP and used for analysis. The keff bias between TULIP code and reference value is less than 300 pcm for all fast spectrum benchmarks. And that bias keeps within 200 pcm for thermal spectrum benchmarks with neutron-moderating materials such as polyethylene, beryllium oxide, etc. The numerical results indicate that TULIP code has good performance for the analysis of fast and thermal spectrum system.

고차원펄스 스펙트럼 분석을 위한 이러닝 시스템의 설계 (Design of e-Learning System for Spectral Analysis of High-Order Pulse)

  • 오용선
    • 한국콘텐츠학회논문지
    • /
    • 제11권8호
    • /
    • pp.475-487
    • /
    • 2011
  • 본 논문에서는 고차원펄스의 스펙트럼을 유도하는 체계적인 방법을 제시하고, 이를 학습내용으로 하는 효율적인 이러닝 시스템을 설계한다. 고차원펄스의 스펙트럼은 연속미분법이나 콘볼루션법 등 기존의 방법에 의하여 유도될 수 있으나, 그 차수가 증가함에 따라 현저하게 높아지는 복잡도 때문에 사용할 수 없다. 우리는 고차원펄스의 차수에 따라 순환적으로 적용되는 알고리듬을 제시하고, 이를 찾아보기표에 의하여 함수적으로 차수에 연관된 스펙트럼의 식을 유도한다. 또한, 이를 이용하여 고차원펄스의 스펙트럼을 분석하는 과정을 학습하는 이러닝 콘텐츠를 설계한다. 여기에는 기존의 순차적 재생을 기본으로 하여 이른바 개념단위 오브젝트별 분기방식을 적용하는 콘텐츠 처리방식이 사용된다. 모델링, 임펄스응답과 전달함수, 파라미터, 찾아보기표 등 전체를 네 개의 개념단위로 분할한 콘텐츠페이지를 설계하고, 이들로부터 하향식으로 분화된 개념단위들을 모듈과 서브모듈로 설정한다. 이들은 개념단위 오브젝트별 분기방식에 의하여 학습자에게 다양한 학습순서와 반복학습 등을 제공하여 상호작용을 증대하고, 저작된 이러닝 콘텐츠에 의한 학습효과를 현저히 향상시킨다. 또한, 콘텐츠 자체의 효율성 측면에서도 현저한 향상을 이룬다.

국내 지진동 특성에 대한 기기 용접 정착부의 비탄성에너지 흡수계수를 고려한 지진취약도 평가 (Seismic Fragility Analysis of Equipment Considering the Inelastic Energy Absorption Factor of Weld Anchorage for Seismic Characteristics in Korea)

  • 임승현;김건규;최인길;곽신영
    • 한국지진공학회논문집
    • /
    • 제27권1호
    • /
    • pp.69-75
    • /
    • 2023
  • In Korea, most nuclear power plants were designed based on the design response spectrum of Regulatory Guide 1.60 of the NRC. However, in the case of earthquakes occurring in the country, the characteristics of seismic motions in Korea and the design response spectrum differed. The seismic motion in Korea had a higher spectral acceleration in the high-frequency range compared to the design response spectrum. The seismic capacity may be reduced when evaluating the seismic performance of the equipment with high-frequency earthquakes compared with what is evaluated by the design response spectrum for the equipment with a high natural frequency. Therefore, EPRI proposed the inelastic energy absorption factor for the equipment anchorage. In this study, the seismic performance of welding anchorage was evaluated by considering domestic seismic characteristics and EPRI's inelastic energy absorption factor. In order to reflect the characteristics of domestic earthquakes, the uniform hazard response spectrum (UHRS) of Uljin was used. Moreover, the seismic performance of the equipment was evaluated with a design response spectrum of R.G.1.60 and a uniform hazard response spectrum (UHRS) as seismic inputs. As a result, it was confirmed that the seismic performance of the weld anchorage could be increased when the inelastic energy absorption factor is used. Also, a comparative analysis was performed on the seismic capacity of the anchorage of equipment by the welding and the extended bolt.

구조물 및 기기의 내진성능 평가를 위한 고주파수 지진에 의한 원자력발전소의 지진응답 증폭계수 (Seismic Response Amplification Factors of Nuclear Power Plants for Seismic Performance Evaluation of Structures and Equipment due to High-frequency Earthquakes)

  • 임승현;최인길;전법규;곽신영
    • 한국지진공학회논문집
    • /
    • 제24권3호
    • /
    • pp.123-128
    • /
    • 2020
  • Analysis of the 2016 Gyeongju earthquake and the 2017 Pohang earthquake showed the characteristics of a typical high-frequency earthquake with many high-frequency components, short time strong motion duration, and large peak ground acceleration relative to the magnitude of the earthquake. Domestic nuclear power plants were designed and evaluated based on NRC's Regulatory Guide 1.60 design response spectrum, which had a great deal of energy in the low-frequency range. Therefore, nuclear power plants should carry out seismic verification and seismic performance evaluation of systems, structures, and components by reflecting the domestic characteristics of earthquakes. In this study, high-frequency amplification factors that can be used for seismic verification and seismic performance evaluation of nuclear power plant systems, structures, and equipment were analyzed. In order to analyze the high-frequency amplification factor, five sets of seismic time history were generated, which were matched with the uniform hazard response spectrum to reflect the characteristics of domestic earthquake motion. The nuclear power plant was subjected to seismic analysis for the construction of the Korean standard nuclear power plant, OPR1000, which is a reactor building, an auxiliary building assembly, a component cooling water heat exchanger building, and an essential service water building. Based on the results of the seismic analysis, a high-frequency amplification factor was derived upon the calculation of the floor response spectrum of the important locations of nuclear power plants. The high-frequency amplification factor can be effectively used for the seismic verification and seismic performance evaluation of electric equipment which are sensitive to high-frequency earthquakes.

여러환경조건에 의한 Silicon애자의 표면열화 진단기술 (Diagnosis Technique of Surface Aging according to Various Environment Condition for Silicon Polymer Insulator)

  • 박재준;정명연;이승욱;김정부;송영철;김희동
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.76-81
    • /
    • 2004
  • This paper presents the results of spectral analysis of leakage current waveforms on contaminated insulators under various fog and environment conditions(salt fog, clean fog, rain) The larger the leakage current during 200ms, the higer the power spectrum at 60Hz. For almost equal maximum current during 200ms, however, the spectrum at 60hz and the odd order harmonics increase emphatically when discharges occur continuously for several half-waves. If contaminated insulators suffers from high salt-density fog, the leakage current occurs with high crest value intermittently, results in the low spectrum. Analysis of leakage current data showed that this electrical activity was characterized by transient arcing behavior contaminants are deposited on the insulator surface during salt fog tests. This provides a path for the leakage current to flow along the surface of the insulator. It is important to have an indication of the pollution accumulation in order to evulate the test performance of a particular insulator. If the drop in surface resistivity is severe enough, then the leakage current may escalate into s service interrupting flashover that degrade power quality.

  • PDF

Preliminary Result of Spectral Analysis Using Objective-Prism Plates

  • Kang, Wonseok;Lee, Sang-Gak;Kwon, Sun-Gill
    • 천문학회보
    • /
    • 제39권2호
    • /
    • pp.119.1-119.1
    • /
    • 2014
  • We present the scanned digital images and their preliminary analysis results of objective-prism plates taken with the Michigan Curtis Schmidt telescope at Cerro Tololo Inter-American Observatory. In order to separate an individual spectrum of a star, it should be required to identify each field star in the plate. Using the PPM(Position and Proper Motion) catalog, we are verifying which star corresponds to the spectrum in a plate. In addition to this, we plan to devise the method for wavelength calibration in each spectrum. Finally we will make them for public use, not only for professional astronomers but also for high school and college students for encouraging them to be interested in the astronomy, especially astronomical spectroscopy and stellar astronomy.

  • PDF

IPI의 확률밀도함수에 의한 근신호의 저주파 특성 해석 (Low Frequency Characteristics Analysis of EMG Signal on the Probability Density Function of the IPI)

  • 류재춘;조원경;박종국;김성환
    • 대한전자공학회논문지
    • /
    • 제25권3호
    • /
    • pp.335-342
    • /
    • 1988
  • In this paper, we proposed a new algorithm for EMG low frequency analysis. Through the power spectrum analysis of Gaussian's, Gamma's and Erlang's PDF(probability density function) based on the proposed algorithm, the proper PDF of IPI (inter pulse interval) representing the firing rate of muscle was suggested. In order to verify the proposed algorithm EMG signals of masseter and biceps muscle were detected by surface electrode and its power spectrum analysis was performed. The experimental results are compared with the computer simulaiton. As a result, the masseter muscle's IPI was fitted by Gamma PDF, having a 10Hz fundamental frequency including n(1+\ulcornerfp high harmnic frequency on 10% MVC(maximum voluntary contaraction). And the biceps muscle's IPI was fitted by Gaussian PDF, also it have a 14Hz fundamental frequency.

  • PDF

Capacity spectrum method based on inelastic spectra for high viscous damped buildings

  • Bantilas, Kosmas E.;Kavvadias, Ioannis E.;Vasiliadis, Lazaros K.
    • Earthquakes and Structures
    • /
    • 제13권4호
    • /
    • pp.337-351
    • /
    • 2017
  • In the present study a capacity spectrum method based on constant ductility inelastic spectra to estimate the seismic performance of structures equipped with elastic viscous dampers is presented. As the definition of the structures' effective damping, due to the damping system, is necessary, an alternative method to specify the effective damping ratio ${\xi}eff$ is presented. Moreover, damping reduction factors (B) are introduced to generate high damping elastic demand spectra. Given the elastic spectra for damping ratio ${\xi}eff$, the performance point of the structure can be obtained by relationships that relate the strength demand reduction factor (R) with the ductility demand factor (${\mu}$). As such expressions that link the above quantities, known as R - ${\mu}$ - Τ relationships, for different damping levels are presented. Moreover, corrective factors (Bv) for the pseudo-velocity spectra calculation are reported for different levels of damping and ductility in order to calculate with accuracy the values of the viscous dampers velocities. Finally, to evaluate the results of the proposed method, the whole process is applied to a four-storey reinforced concrete frame structure and to a six-storey steel structure, both equipped with elastic viscous dampers.

최소자승 스펙트럼분석을 통한 GPS상시관측소의 안정성 평가 (Stability Evaluation of Permanent GPS Site by Least Square Spectrum Analysis)

  • 윤홍식
    • 한국측량학회지
    • /
    • 제18권4호
    • /
    • pp.379-385
    • /
    • 2000
  • 본 논문에서는 GPS 상시관측소들의 안정성을 평가하여 성과산정의 정밀도를 향상시키기 위하여 수원, Tsukuba, 상하이 관측점의 좌표변화량에 대한 최소자승 스펙트럼 분석을 실시하였다. 수원, 스꾸바 및 상하이 상시관측점들은 1994년 이후 지속적으로 관측을 실시하여 오고 있어 계산된 좌표 변화량의 시간이력들에 대한 장기적인 재현성과 주기성을 분석하였다.

  • PDF

Transient testing from LV / SC coupled analysis by new shock synthesis

  • Girard, Alain;Cavro, Etienne;Dupuis, Paul-Eric
    • Advances in aircraft and spacecraft science
    • /
    • 제5권2호
    • /
    • pp.177-186
    • /
    • 2018
  • This paper deals with the idea to replace the usual high-level sine sweep test on shaker at system level, very severe, by a low level one completed by a transient test in the same configuration, in order to be more representative of the real environment, thus limiting over testing and improving the payload comfort. The problem of the transient test specification is first discussed. The proposed solution is to derive from LV/SC coupled analyses a shock response spectrum corresponding to two damping ratios. Then, the question of adequate shock synthesis is tackled. A new method with a given spectrum is considered for better potential and accuracy than the usual wavelets. A campaign on the Intespace bi-shaker devoted to system level showed its capability to perform the resulting test with one spectrum. First investigations to extend this approach to two spectra are in progress.