• 제목/요약/키워드: High order scheme

검색결과 1,113건 처리시간 0.033초

데드비트 및 디지털 반복제어에 의한 고차 체인드 시스템의 제어 (High order chained system control using deadbeat and iterative control)

  • 남택근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권4호
    • /
    • pp.455-461
    • /
    • 2007
  • In this paper a state steering strategy for high order chained system is presented. High order chained system can be derived from the acceleration constraints that cannot be integrable. The system classified as a nonholonomic system cannot be controlled to its equilibrium points by continuous and time-invariant controller. Using variable transformation two sub system can be obtained from the high order chained system. Deadbeat control and iterative state steering methods are proposed to control the system. Simulation results are given to show the effectiveness of the proposed control scheme.

FUNWAVE-TVD 수치모형을 이용한 수중천퇴를 통과하는 불규칙파의 수치모의에서 TVD 기법들에 의한 수치해 비교 (Comparison of Numerical Solutions by TVD Schemes in Simulations of Irregular Waves Propagating over a Submerged Shoal Using FUNWAVE-TVD Numerical Model)

  • 최영광;서승남
    • 한국해안·해양공학회논문집
    • /
    • 제30권4호
    • /
    • pp.143-152
    • /
    • 2018
  • 최근 개발된 FUNWAVE-TVD 파랑모형을 이용하여 적용되어 온 TVD 기법들의 수렴도와 수치적인 안정성을 비교하였다. Yamamoto and Daiguji(1993)의 minmod limiter를 사용하는 4차 정확도의 MUSCL-TVD 기법과 Erduran et al.(2005)의 van-Leer limiter를 사용하는 4차 정확도의 MUSCL-TVD 기법, Zhou et al.(2001)의 van-Leer limiter를 사용하는 2차 정확도의 MUSCL-TVD 기법을 비교하였으며, 수리실험 관측치가 제시되어 있는 Vincent and Briggs(1989)의 불규칙 파랑실험에 적용하였다. 불규칙 파랑의 비쇄파 실험 결과에서 minmod limiter를 사용하는 4차 정확도의 기법은 van-Leer limiter를 사용하는 기법이 요구하는 격자의 크기만큼 세밀한 격자를 요구하지는 않지만, 더 낮은 CFL을 사용해야 안정적인 모의가 가능하였다. 반면에 van-Leer limiter를 사용하는 기법에서는 numerical dissipation을 줄이기 위하여 보다 세밀한 격자를 필요로 하지만 비교적 높은 CFL을 사용할 수 있는 것으로 나타났다. 각 기법의 numerical dissipation의 영향을 최대한 줄이기 위하여 공간격자를 충분히 줄인 쇄파 모의 실험에서는 비쇄파 실험에 비하여 각 기법의 특성이 명확히 나타났다. Numerical dissipation이 상대적으로 작은 minmod limiter를 사용하는 기법으로 모의할 때는 격자를 충분히 줄이면 수치적인 불안정성이 나타나며 수치해가 발산하는 결과를 보였지만, van-Leer limiter를 사용하는 기법에서는 비교적 낮은 CFL을 사용하여 쇄파 모의가 완료되었으며, 관측치를 잘 재현하는 결과를 보였다.

소비자의 감성과 소비유형을 이용한 협업여과기반 콘텐츠 추천 기법 (A Contents Recommendation Scheme Based on Collaborative Filtering Using Consumer's Affection and Consumption Type)

  • 최인복;박태근;이재동
    • 정보처리학회논문지D
    • /
    • 제15D권3호
    • /
    • pp.421-428
    • /
    • 2008
  • 협업여과 기법은 추천 시스템에서 널리 사용되는 기술이지만, 소비자의 참조그룹을 선정하는 방법에 따라 추천의 정확도가 달라지는 특성을 가지고 있다. 이에 본 논문에서는 콘텐츠 추천의 정확도를 높이기 위하여 소비자의 감성과 소비유형을 참조그룹으로 하여 협업여과기반으로 콘텐츠를 추천하는 기법을 제안한다. 소비자의 감성을 기쁨, 슬픔, 혐오, 행복, 이완 다섯 가지로 구분하고, 소비유형을 저실용/저쾌락, 저실용/고쾌락, 고실용/저쾌락, 고실용/고쾌락 네 가지로 구분하여 콘텐츠 추천 기법의 성능을 분석한 결과, 본 논문에서 제안하는 기법으로 콘텐츠를 추천한 경우가 소비자 감성과 소비유형을 고려하지 않은 전체 참조그룹으로 추천한 경우보다 정확도가 향상됨을 확인하였다.

고출력 증폭기의 비선형 왜곡 특성에 강인한 Companding 기법 (A Robust Companding Scheme against Nonlinear Distortion of High Power Amplifiers)

  • 김재운;한승우;신요안
    • 한국통신학회논문지
    • /
    • 제32권11C호
    • /
    • pp.1079-1086
    • /
    • 2007
  • 본 논문에서는 고출력 증폭기 (High Power Amplifier; HPA)의 비선형 특성에 관계없이 시스템의 비트오율 (Bit Error Rate; BER) 성능을 유지하면서 동시에 효율적으로 PAPR (Peak-to-Average Power Ratio)을 감소시킬 수 있는 CCP (Companding Combined with Predistorter) 기법을 제안한다. 제안된 CCP 기법은 기존에 본 저자들이 제안한 Companding 기법이 가지고 있는 Compression 특성과 HPA의 비선형 왜곡 특성에 의해 발생되는 전송 신호의 왜곡으로 인해 나타나는 시스템의 BER 성능 열화를 보완하기 위해 Predistorter를 기존의 Companding 기법에 결합하였다. 따라서, 제안된 CCP 기법은 HPA의 비선형 특성에 관계없이 효율적으로 PAPR을 감소시킬 수 있으며 동시에 시스템의 BER 성능도 유지시킬 수 있는 PAPR 감소 방식이라고 할 수 있다. 모의실험 결과, 제안된 CCP 기법은 TD (Total Degradation) 측면에서 Predistorter를 고려한 Clipping 기법과 Wang이 제안한 Companding 기법에 비해 모든 변조방식에서 가장 낮은 TD 성능을 나타내고 있음을 확인하였다.

Advanced Static Over-modulation Scheme using Offset Voltages Injection for Simple Implementation and Less Harmonics

  • Lee, Dong-Myung
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.138-145
    • /
    • 2015
  • In this paper, a novel static overmodulation scheme (OVM) for space-vector PWM (SVPWM) is proposed. The proposed static OVM scheme uses the concept of adding offset voltages in linear region as well as overmodulation region to fully utilize DC-link voltage. By employing zero sequence voltage injection, the proposed scheme reduces procedures for achieving SVPWM such as complicated gating time calculation. In addition, this paper proposes a stepwise discontinuous angle movement in high modulation region in order to reduce Total Harmonic Distortion (THD). The validity of the proposed scheme is verified through theoretical analysis and experimental results.

Simple 알고리즘을 이용한 압축성유동해석 (Numerical Calculations of Compressible Flows using a SIMPLE Algorithm)

  • 안희섭;손창현;문수연
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2000년도 춘계 학술대회논문집
    • /
    • pp.184-190
    • /
    • 2000
  • A well-known pressure correction method, a SIMPLE algorithm is extended to treat compressible flows. Collocated grids are used and density is linked to pressure via an equation of state. The influence of pressure on density in the case of compressible flows is implicitly incorporated into the extended SIMPLE algorithm. The first-order Upwind and high-order Quick scheme are compared with respect to an accuracy and convergence time at all speeds. The extended method is verified on a number of test cases and the results we compared with other numerical results available in the literature. The calculated results show that the Quick scheme improves accuracy at all speed and also reduces the calculation time at supersonic flows, compared with the Upwind scheme.

  • PDF

SIMPLE 알고리즘을 이용한 압축성유동해석 (Numerical Calculations of Compressible Flows using a SIMPLE Algorithm)

  • 안희섭;손창현;문수연
    • 한국전산유체공학회지
    • /
    • 제5권2호
    • /
    • pp.1-8
    • /
    • 2000
  • A well-known pressure correction method, a SIMPLE algorithm, is extended to treat compressible flows. Collocated grids are used and density is linked to pressure via an equation of state. The influence of pressure on density in the case of compressible flows is implicitly incorporated into the extended SIMPLE algorithm. The first-order Upwind and high-order Quick scheme are compared with respect to an accuracy and convergence time at all speeds. The extended method is verified on a number of test cases and the results are compared with other numerical results available in the literature. The calculated results show that the Quick scheme improves accuracy at all speed and also reduces the calculation time at supersonic flows, compared with the Upwind scheme.

  • PDF

Reverse Iterative Image Encryption Scheme Using 8-layer Cellular Automata

  • Zhang, Xing;Zhang, Hong;Xu, Chungen
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권7호
    • /
    • pp.3397-3413
    • /
    • 2016
  • Considering that the layered cellular automata (LCA) are naturally fit for representing image data in various applications, a novel reverse iterative image encryption scheme based on LCA is proposed. Specifically, the plain image is set as the final configuration of an 8-layer CA, and some sequences derived from a random sequence are set as the pre-final configuration, which ensure that the same plain image will never be encrypted in the same way when encrypted many times. Then, this LCA is backward evolved by following some reversible two order rules, which are generated with the aid of a newly defined T-shaped neighborhood. The cipher image is obtained from the recovered initial configuration. Several analyses and experimental results show that the proposed scheme possesses a high security level and executive performance.

콘버어터의 전원 고조파분을 저감시키기 위한 SHE PWM 방식의 적응 (Application of SHE PWM Scheme for Reducing The Source Harmonic Components of Converter)

  • Chung, Dong-Hwa
    • 대한전자공학회논문지
    • /
    • 제27권9호
    • /
    • pp.1427-1435
    • /
    • 1990
  • This paper proposes the Selected Harmonic Elimination Pluse Width Modulation (SHE PW) scheme toreduce the ahrmonic components of source line current. To eliminate the low order harmonics which affects the source dominatly, we apply the Fourier series analysis to line current waveforms and then find out the switching patterns using the SHE PWM scheme. In addition to the analysis of harmonic effects, the three phase filter circuit is used to reduce high order harmonics. For the experimental realization, the converter circuit with power Transistor(PTR) is designed and the Pulse Time Control(PTC) is applied. The line current and the load voltage are measured under the condition of three phase application, highly inductive load.

  • PDF

출력궤환 가변구조 제어계의 설계에 관한 연구 (Design of an Output Feedback Variable Structure Control System)

  • 이기상;조동식
    • 대한전기학회논문지
    • /
    • 제41권8호
    • /
    • pp.883-892
    • /
    • 1992
  • In order to remove the assumption of full state availability which is one of the major difficulties with the practical realization of variable structure control system (VSCS), an output feedback variable structure control scheme for multivariable systems is proposed. The proposed output feedback VSCS is composed of a switching surfaces with dynamic structure and a new output feedback control input that can be constructed by using conventional output feedback control input design methodologies. With the proposed scheme, the practical realization of VSCS for the systems with unmeasurable states and for high order systems that conventional schemes cannot be applied is possible. Simulation results show that proposed scheme is a viable method to achieve the desired control performance, for example, good transient response, robustness against process parameter variations and external disturbance without measuring all the state variables.