• 제목/요약/키워드: High level of ozone

검색결과 76건 처리시간 0.025초

Characteristics of near-surface ozone distribution

  • Kim, Yoo-Keun;Lee, Hwa-Woon;Kim, Jae-Hwan;Moon, Yun-Seob;Song, Sang-Keun
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제4권3호
    • /
    • pp.127-137
    • /
    • 2000
  • This study presents an analysis of the characteristics of vertical ozone distribution near the surface using ozonesonde data(l995 to 1998), plus surface ozone and meteorological data from the Pohang region. These features were examined in detail using three case studies. The first related to episodes of high surface ozone concentrations during the Spring season when the frontogenesis between the high and low pressure associated with the upper-level jet stream was found to be located near the surface. The second was a 5-day winter period(l3 -17 December, 1997) in the Pohang province when the hourly concentrations exceeded 90 ppb on several occasions owing to low-level jets(LLJs) induced by a nocturnal stable layer. Accordingly, this explains why the high surface ozone concentrations occurred at night as the ozone was transported across the zone by a strong wind speed( over 12.5 ms .1). The third case study was ozone enhancement due to photochemical reactions. In this case, the maximum concentration of ozone exceeded 60 ppb in the summer(23 -28 August, 1997). When an ozone peak appeared within the boundary layer, the occurrence frequency of a low-level jet due to the nocturnal stable layer was about 77%, similarly the occurrence frequency of a near-surface ozone peak relative to the appearance of an LLJ was about 76%. Accordingly, there is clearly a close correlation between the occurrence of LLJs and near-surface ozone peaks.

  • PDF

오존 대기 환경기준의 비교 연구 (A Comparative study on Ambient Air Quality Standard for Ozone)

  • 허정숙;김태오;김동술
    • 한국대기환경학회지
    • /
    • 제15권2호
    • /
    • pp.159-173
    • /
    • 1999
  • Based on air quality monitoring data('89~'97) operated by the Department of Environment, we provide various fundamental statistics for ground ozone. The purpose of this paper are to review the national ambient ozone standard, to study spatial distribution of ozone. Since we, in Korea, calculate average ozone level, to examine the occurrences of ozone level 3 times a day (1~8, 9~16, 17~24 hours), the method does not seem to be scientifically sound comparing to a running average method adapted by the USEPA. When we counted the number of cases with 8-h average O3 level exceeding 60ppb(8-h average standard in Korea)and 80 ppb (that in the U.S.A) and also when we calculated 8-hour average ozone level based on th US method, some regions were classified as non-attainment areas. Especially in Seoul, results of spatial distribution analysis showed that high level ozone over 80 ppb was observed at Kuui-Dong and Pangi-Dong in the eastern part and at Ssangmun-Dong in the northeastern part. Also, occurrences of ozone episode defined as number of days then ozone level exceeding 80 ppb for 3 consecutive hours were extensively reviewed in this paper.

  • PDF

경기도 안양시 오존농도의 시계열모형 연구 (Analysis of Time Series Models for Ozone Concentration at Anyang City of Gyeonggi-Do in Korea)

  • 이훈자
    • 한국대기환경학회지
    • /
    • 제24권5호
    • /
    • pp.604-612
    • /
    • 2008
  • The ozone concentration is one of the important environmental issue for measurement of the atmospheric condition of the country. This study focuses on applying the Autoregressive Error (ARE) model for analyzing the ozone data at middle part of the Gyeonggi-Do, Anyang monitoring site in Korea. In the ARE model, eight meteorological variables and four pollution variables are used as the explanatory variables. The eight meteorological variables are daily maximum temperature, wind speed, amount of cloud, global radiation, relative humidity, rainfall, dew point temperature, and water vapor pressure. The four air pollution variables are sulfur dioxide $(SO_2)$, nitrogen dioxide $(NO_2)$, carbon monoxide (CO), and particulate matter 10 (PM10). The result shows that ARE models both overall and monthly data are suited for describing the oBone concentration. In the ARE model for overall ozone data, ozone concentration can be explained about 71% to by the PM10, global radiation and wind speed. Also the four types of ARE models for high level of ozone data (over 80 ppb) have been analyzed. In the best ARE model for high level of ozone data, ozone can be explained about 96% by the PM10, daliy maximum temperature, and cloud amount.

퍼지 클러스터링을 이용한 고농도오존예측 (Forecasting High-Level Ozone Concentration with Fuzzy Clustering)

  • 김재용;김성신;왕보현
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2001년도 춘계학술대회 학술발표 논문집
    • /
    • pp.191-194
    • /
    • 2001
  • The ozone forecasting systems have many problems because the mechanism of the ozone concentration is highly complex, nonlinear, and nonstationary. Also, the results of prediction are not a good performance so far, especially in the high-level ozone concentration. This paper describes the modeling method of the ozone prediction system using neuro-fuzzy approaches and fuzzy clustering. The dynamic polynomial neural network (DPNN) based upon a typical algorithm of GMDH (group method of data handling) is a useful method for data analysis, identification of nonlinear complex system, and prediction of a dynamical system.

  • PDF

Analysis of Time Series Models for Ozone Concentrations at the Uijeongbu City in Korea

  • Lee, Hoon-Ja
    • Journal of the Korean Data and Information Science Society
    • /
    • 제19권4호
    • /
    • pp.1153-1164
    • /
    • 2008
  • The ozone data is one of the important environmental data for measurement of the atmospheric condition of the country. In this article, the Autoregressive Error (ARE) model have been considered for analyzing the ozone data at the northern part of the Gyeonggi-Do, Uijeongbu monitoring site in Korea. The result showed that both overall and monthly ARE models are suited for describing the ozone concentration. In the ARE model, seven meteorological variables and four pollution variables are used as the as the explanatory variables for the ozone data set. The seven meteorological variables are daily maximum temperature, wind speed, relative humidity, rainfall, dew point temperature, steam pressure, and amount of cloud. The four air pollution explanatory variables are Sulfur dioxide(SO2), Nitrogen dioxide(NO2), Cobalt(CO), and Promethium 10(PM10). Also, the high level ozone data (over 80ppb) have been analyzed four ARE models, General ARE, HL ARE, PM10 add ARE, Temperature add ARE model. The result shows that the General ARE, HL ARE, and PM10 add ARE models are suited for describing the high level of ozone data.

  • PDF

Optical Ozone Monitor Using UV Source

  • Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.49-52
    • /
    • 2003
  • Two types of ozone monitors using UV absorption method were tried in consideration of cost of the monitor and precision in measuring. The high concentration ozone monitor for high concentration real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source, a photo multiplier tube as UV detector and signal processing unit for the most part. This structure could be very useful for low price high concentration ozone monitor due to simple system structure and fairly good monitoring characteristics. The developed system showed good linear output characteristics to ozone in the measuring concentration range of 0.05 and 2 wt.%. For accuracy ambient ozone monitoring in ambient in ppm level, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector and signal processing unit in brief speaking was proposed our study for the first time in the world. The developed system showed good linearity and sensitivity in relative low measuring range between 10ppm and 10,000ppm, and showed some feasibility of high resolution ozone monitor using CCD array as photodetector.

  • PDF

The Analysis of Correlation between BVOCs and Ozone at Taehwa Research Forest

  • Kim, Dan-Bi;Lee, Sang-Deok;Lee, Seung-Ha;Kim, Rhok-Ho;Lee, Yeong-Jae;Chae, Hee-Mun
    • Journal of Forest and Environmental Science
    • /
    • 제34권2호
    • /
    • pp.153-161
    • /
    • 2018
  • Ozone absorbs ultraviolet light which is harmful to life. However, the recent increase of ambient ozone level due to climate change is becoming the cause of stimulating human eyes, affecting respiratory system, and damaging crops. In this paper, a study was conducted at the Taehwa Research Forest (TRF) of Seoul National University with the purpose of analyzing the characteristics of forest air chemistry based on the measurement of BVOCs emitted from forests and investigating the correlation of BVOCs with ozone generation. The results showed that levels of isoprene and MVK (Methyl Vinyl Keton)+MACR (Methacrolein) were high in summer, but level of monoterpene was high in spring. Ozone level was high from the middle of May to the middle of June, which was before the rainy season. Comparison of the correlation between ozone and isoprene during the measurement period at the TRF showing limited NOx showed that the $R^2$ was correlated with a low value of about 0.4. However, when the isoprene was actively produced from 6:00 AM to 6:00 PM, correlation analysis showed that $R^2$ was about 0.9, while monoterpene started to increase in the afternoon, and decreased level of ozone at night. Correlation analysis showed negative correlation. Forests have two characteristics: not only the formation of ozone but also the decomposition of ozone.

광양만 권역에서의 고농도 오존 사례에 대한 기상 및 대기질 분석 (The Analysis of Atmospheric Flow Field and Air Quality According to the High Level Ozone Case on Gwangyang Bay)

  • 최현정;이화운;임헌호;송재활
    • 한국환경과학회지
    • /
    • 제17권7호
    • /
    • pp.743-753
    • /
    • 2008
  • Gwangyang Bay is often severely confronted by photochemical pollutants due to its location and dense emissions. It is located in a basin on the south coast of the Korean peninsula and is crossed by a remarkable cluster of hills and mountains of a small horizontal scale that forms a channel. Clearly, the air flow field has a great influence on the dispersion of air pollutants. The characteristics of the wind flow patterns have an important effect on the dispersion of pollutants emitted. In these situations, the distribution of the ozone concentration is extremely complicated because of the superposition of circulations of the air flow fields, especially in complex coastal region. In this study, we examined the distribution of the high level ozone on Gwangyang Bay particularly during the episode day (for 5 years). Among these days, A high level ozone was induced by the development of a sea/land breeze local circulation system, as well as by an anabatic/catabatic flow from the mountains and valley with weakening of the synoptic wind. High level ozone distribution pattern(6 types) on Gwangyang bay is analyzed and the comparison of each pattern reveals substantial localized differences in intensity and distribution of ozone concentration from the site coherence and UPA analysis of ozone concentration. The observed VOC concentration had much difference in concentrations and daily variations between Jungdong and Samil.

충북 청원군에서 관측된 지표면 부근의 오존 (Measutements of the ground-level ozone in a rural area of Chongwon, Korea)

  • 윤마병;정용승
    • 한국대기환경학회지
    • /
    • 제11권1호
    • /
    • pp.85-93
    • /
    • 1995
  • Measurements of ground level ozone concentrations were made in a rural area of Chongwon (Choongbook Province) from June 1993 to July 1994. High values frequently exceeding 100 ppb (ambient air qualyty standard of Korea) were recorded. High ozone concentrations in the boundary layer were primarily correlated with the several meteorological parameters in warm seasons: pressure, radiation, temperature, precipitation and wind velocity. The annual average concentration of ozone at Chongwon was 17ppb, and this value was relatively higher than those for other cities in Korea. O$\_$3/ concentrations were observed to increase when the ridge of a surface anticyclone was passing over the region, and maximum values(.geq.100 ppb) were observed on the rear sides of high pressure centers and in the warm sectors of cyclones(well head of cold fronts). The ozone concentrations had a negative correlation with the concentration of primary pollutants(e.g., total hydrocarbons).

  • PDF

구형파 및 PWM 인버터 조합에 의한 오존발생용 인버터 (The Invert for ozone generator by mixed square_wave and PWM)

  • 박노식;박성준;원태헌;안진우;김철우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1193-1195
    • /
    • 2004
  • Ozone gas is one of the strongest oxidizing and bleaching agents which leave no residues harmful to the global environment. In recent years, the ozone generator has been widely utilized, However, it has been known that a broader application of ozone is hindered primarily because of its low efficiency of generation. Thus, it is more indispensable to improve actual system efficiency of the silent discharge type ozonizer using high frequency inverter. This paper presents a multi level resonant ozone power regulation by association of high frequency transformers and full bridge invert. And proposed resonant inverter system can generate continuous output voltage. can control linearly quantity of ozone gas. This invert that add PWM forms within square forms of output voltage about one level range. The power regulation characteristics and operating performances of silent discharge (SD)type ozone generating tube load driven by this load proposed inverter using FET modules are illustrated from a practical point of view, which can operate under stable conditions of basic level and PWM hybrid control strategy implemented DSP(2406). The effectoveness of propsed invert type ozonizer is proved by experiment results.

  • PDF