원편파를 이용한 무전극 고압 방전 램프 시스템에 관한 연구 (A Study on Electrodeless HID Lamp Systems Using Circularly Polarized Microwaves)

  • 김경신;김진중;이승철
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.214-220
    • /
    • 2010
  • This paper presents the results of a study on an electrodeless high intensity discharge (HID) lamp system that is powered by circularly polarized microwaves (CPMs). The technique to generate CPMs enables an electrodeless high intensity discharge lamp to be turned on without the retation of the bulb but conventional electrodeless high intensity discharge lamps use rotating bulbs in order to prevent a puncture in a hot spots that are formed by the linearly polarized microwaves in the circular cavity. The technique to generate CPMs is described and the salient features of the lamp characteristics are presented.

Soft Switching Multi Level Inverter를 이용한 HID용 Ballast (HID Ballast using Soft Switching Multi Level Inverter)

  • 이장선;김윤호;김수홍
    • 전력전자학회논문지
    • /
    • 제9권6호
    • /
    • pp.628-634
    • /
    • 2004
  • 차량용 전조등에 사용되어지는 HID(High Intensity Discharge) 발라스트(Ballast)의 특성 개선을 위하여 소프트 스위칭 방식의 멀티 레벨 인버터를 적용하였다. 멀티레벨 인버터의 모드(Mode)별 특성을 해석하고, 그 결과를 통해 발라스트의 출력 특성을 해석하고 시스템을 설계하였다. 그리고 실험을 통하여 해석결과를 확인하였다.

전자식 안정기를 위한 HID Lamp 시뮬레이션 모델 (A PSpice Model for the Electrical Ballast of HID Lamps)

  • 지윤근;권원목;김남준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.123-125
    • /
    • 2002
  • To simulate the characteristics of an High-Intensity Discharge Lamp, this paper uses PSpice circuit model which have been developed from modification of the classical Cassie and Mayr equations. The model is for an High-Intensity Discharge Lamp and compatible to adopt high-frequency electric ballast. This model is correspond to some conditions between the simulated and experimental results.

  • PDF

광학렌즈 AR 코팅에 따른 폴리머애자에서의 방전 자외선 강도 비교 (Comparison of Discharge UV Intensity Due to AR Coating of Optic Lens on Polymer Insulator)

  • 김영석;송길목;방선배;김종민;최명일
    • 조명전기설비학회논문지
    • /
    • 제26권4호
    • /
    • pp.35-40
    • /
    • 2012
  • In this study, the ultraviolet (UV) intensity of polymer insulator was measured using the Anti-Reflective (AR) coating lens on the occurrence of corona discharge. The UV intensity was compared before and after the AR coating. Under the 200-260[nm] of UV lens, the reflection rate before AR coating was 7.5~5.5[%] with 85-89[%] of transmission rate. After AR coating, however, the reflection rate decreased to 1.3~1.22[%] with improved transmission (97.4~97.6[%]). Then, the UV intensity by distance was measured in the polymer insulator. According to the measurement, the UV intensity increased 6.5 times at 37.5[%] of Vm/Vbd with 5[m] of distance. As distance increased, the growth rate declined. As high voltage increased, in addition, AR coating was less effective due to the count error caused by the UV sensor pulse signal overlap. Therefore, it appears that it would be more effective to detect corona discharge with 5[m] or less of distance at diagnosis of power facilities by AR coating and UV sensor sensitivity.

무수은 무전극 유도-용량형 직관형 램프 방전에 관한 연구 (Investigation of Hg free Electrodeless inductively capacitive tubular discharge)

  • 이태일;박해일;백홍구
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.191-196
    • /
    • 2002
  • In this paper we introduce novel electrode structure for high efficiency discharge. We operate discharge tube under the 0.16 torr pure Xe and apply the sinusoidal wave power to the lamp with 60kHz. We measure the electric power dissipation, plasma parameters, and 828 nm IR intensity. From these data we determine the discharge efficiency, IR intensity/watt, EEDF(Electron energy distribution function). As a result we obtain that the novel electrode structure has better performance in efficiency than that of conventional external electrode system. Also we determine the EEDF for each type of electrode structure by Boltzmann stover, EELNDIF code. The result of Boltzmann equation solving show that the noble electrode system has many high energy electrons compared with the conventional system.

  • PDF

고휘도 Short-Arc 램프용 전자식 안정기 설계 및 제작 (The Design and Fabrication of an Electronic Ballast for High Intensity Short-Arc Lamps)

  • 김일권;박대원;이성근;길경석
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.304-309
    • /
    • 2005
  • This paper presents an electronic ballast using a step down converter, a low frequency inverter for high intensity short-arc discharge lamp. The proposed ballast is composed of a full-wave rectifier, a step down converter operated as a current source with power regulation and a low frequency inverter with external ignition circuit. The ignition circuit generates high voltage pulse of $3{\sim}5[kV]$ peak, 130[Hz] periodically. Moreover, it is able to reignite at regular intervals by protective circuit. As experimental results on the test, acoustic resonance phenomenon is eliminated by operating the low frequency square wave voltage and current. Lamp voltage, current and consumption power are measured 123.8[V], 8.1[A] and 1,002[W], respectively. It was confirmed that the designed ballast operate the lamp with a constant power.

  • PDF

Comparative Study on the Runoff Process of Granite Drainage Basins in Korea and Mongolia

  • Tanaka, Yukiya;Matsukura, Yukinori
    • 한국제4기학회지
    • /
    • 제17권2호
    • /
    • pp.79-84
    • /
    • 2003
  • This study revealed the differences in runoff processes of granite drainage basins in Korea and Mongolia by hydrological measurements in the field. The experimental drainage basins are chosen in Korea (K-basin) and Mongolia (M-basin). Occurrence of intermittent flow in K-basin possibly implies that very quick discharge dominates. The very high runoff coefficient implies that most of effective rainfall quickly discharge by throughflow or pipeflow. The Hortonian overlandflow is thought to almost not occur because of high infiltration capacity originated by coarse grain sized soils of K- basin. Very little baseflow and high runoff coefficient also suggest that rainfall almost does not infiltrate into bedrocks in K-basin. Flood runoff coefficient in M-basin shows less than 1 %. This means that most of rainfall infiltrates or evaporates in M-basin. Runoff characteristics of constant and gradually increasing discharge imply that most of rainfall infiltrates into joint planes of bedrock and flow out from spring very slowly. The hydrograph peaks are sharp and their recession limbs steep. Very short time flood with less than 1-hour lag time in M-basin means that overland flow occurs only associating with rainfall intensity of more than 10 mm/hr. When peak lag time shows less than 1 hour for the size of drainage area of 1 to 10 km2, Hortonian overland flow causes peak discharge (Jones, 1997). The results of electric conductivity suggest that residence time in soils or weathered mantles of M-basin is longer than that of K-basin. Qucik discharge caused by throughflow and pipeflow occurs dominantly in K-basin, whereas baseflow more dominantly occur than quick discharge in M-basin. Quick discharge caused by Hortonian overlandflow only associating with rainfall intensity of more than 10 mm/hr in M-basin.

  • PDF

자동차 조명장치용 고압 방전등 시스템의 특성해석에 관한 연구 (A Study on the Characteristics Analysis of Automotive Ballast System)

  • 이두호;김병우
    • 한국산학기술학회논문지
    • /
    • 제12권9호
    • /
    • pp.3795-3801
    • /
    • 2011
  • 자동차 방전 램프의 전압과 전류에 대한 수학적 해석은 고전압 안정기 해석 및 설계에 유용하게 활용된다. 본 논문에서는 자동차 방전 램프에서 발생되는 램프 전력과 음극 전압 강하 현상에 대한 수학적 모델을 제안하였다. 제안된 모델에 적용된 수치해석 알고리즘을 구현하였고 여기에서 발생된 해석결과는 실험과 비교 검토하였다. 또한, 본 논문에서는 설계 기반의 해석방법을 적용하여 자동차용 고전압 안정기 핵심 부품에 대한 설계 인자를 도출하였다.

Auto-Leveling of HID Headlamp Using Preview Control

  • Yang, Boojoong;Kang, Heeyong;Yang, Sungmo
    • Journal of Mechanical Science and Technology
    • /
    • 제16권11호
    • /
    • pp.1404-1411
    • /
    • 2002
  • A newly developed high intensity discharge (HID) automotive headlamp results in a high luminous gradient at the cutoff line, and proves the superior concept in safer and more com-fortable nighttime driving. This new headlamp technology Provides drivers expanded night vision by a significantly improved light pattern. However, the HID headlamp may dazzle other traffics during traversing a rough road or encountering an unexpected bump. To resolve this problem, an automatic headlamp leveling device is necessary. A preview control is presented for the design of the leveling system. The proposed control algorithm is capable of attenuating a dynamic glare which is one of the major detractors to a driving in dark roads. Computer simulations using ADAMS are carried out to confirm the effectiveness on the control system.