• Title/Summary/Keyword: High humidity

Search Result 1,719, Processing Time 0.042 seconds

Effects of Temperatures and Relative Humidities on the Development of Brown Planthopper, Nilaparvata Zugens (Stal) (온도와 습도가 벼멸구의 생육에 미치는 영향에 관한 연구)

  • Park Chung Gyoo;Hyun Jai Sun
    • Korean journal of applied entomology
    • /
    • v.22 no.4 s.57
    • /
    • pp.262-270
    • /
    • 1983
  • The newly hatched nymphs of brown planthopper(BPH) were reared individually for two generations in test tubes, where young rice seedling was planted on agar solution, at $30^{\circ}C,\;25^{\circ}C\;and\;20^{\circ}C\;with\;95\%,\;75\%,\;65\%\;and\;35\%$ R.H. Effects of $30^{\circ}C$ on the development of BPH when compared with those of $25^{\circ}C$ are followings. Egg period, nymphal period, and adult longevity were shortened. Nymphal mortality was increased and the number of oviposited eggs was decreased. Hatchability was zero per cent because the eggs were either unfertilized or died before finishing the development. At the low temperature of $20^{\circ}C$, in comparision with $25^{\circ}C$, the developmental period of nymphs and eggs was considerably lengthened, and adult longevity was shortened, the number of oviposited eggs was decreased. The nymphal mortality was higher at high relative humidity $(above\;75\%\;RH)$ than that at low relative humidity $(under\;65\%\;RH)$. Under the condition of high relative humidities, the adult longevity was shortened, and the number of oviposited eggs was decreased.

  • PDF

The Effects of the Dehumidifying Membrane Dryer for the Curing Processes of Waterborne Adhesives (수용성 접착제 경화 공정용 제습 막 건조기 시스템의 효과)

  • Yu, Seoyoon;Lim, Choong-Sun;Seo, Bongkuk
    • Journal of Adhesion and Interface
    • /
    • v.17 no.2
    • /
    • pp.62-66
    • /
    • 2016
  • The curing processes of waterborne adhesives are in general undergone by using hot-air dryer. The hot-air dryer curing the adhesives with heat has a disadvantage of requiring high temperature over $100^{\circ}C$ as well as curing time as long as 20 min. When it comes to the heat control, high temperature open disturbs the adhesion of substrates by extremely lowering the viscosity of the adhesives. Furthermore, the humidity resulting from the drying process makes the curing condition irregularly. In this report, dehumidifying membrane dryer was used in order to keep the curing process same by removing humidity caused by the evaporation of water during the drying process, and to shorten the curing time. Here, we compared the peel strength of attached substrates in the dehumidifying membrane dryer to find out appropriate curing condition and confirm the effects of the dehumidifying membrane.

Enhancing Design and Evaluating Mobility of Firefighting Chemical and Flame Protective Clothing for the National 119 Rescue Headquarters (중앙119구조본부 소방대원용 화학 보호복과 방열복의 동작적합성 평가 및 디자인 개선)

  • Syifa Salsabila;Do-Hee Kim;Joo-Young Lee
    • Fashion & Textile Research Journal
    • /
    • v.25 no.4
    • /
    • pp.520-533
    • /
    • 2023
  • The present study developed a test protocol for evaluating the mobility of firefighting chemical and flame personal protective equipment (PPE) for the National 119 Rescue Headquarters in Korea and suggested ergonomic design factors to improve their mobility and performance. Six types of PPE were employed, including three types for flame protective PPE (5 ~ 6 kg excluding the self-contained breathing apparatus), and three types for chemical and flame protective PPE (8 ~ 11 kg). These PPEs are used by the 119 Rescue firefighters. Three male firefighters (34.3 ± 1.2 y in age, 175 ± 8 cm in height, 81 ± 13 kg in body weight) participated in the mobility test and interview. A mobility test protocol consisting of 16 components (nine postures and seven motions including a dexterity test) along with a visibility test were developed based on pre-interviews and literature reviews. The findings indicated that the clothing microclimate humidity on the neck and chest exceeded 85%RH on average for all the six PPE conditions, with the chest area reaching as high as 98%RH. This high humidity caused fogging inside the visor and impaired visibility. The requirements for improving the PPE design in terms of mobility varied depending on whether it was the separated types or all-in-one types, particularly regarding the hood and gloves design. The findings of this study can be applied to improve the design of Level A_PPE for firefighters. The mobility test protocol and visibility test developed in this study can also be applied to other types of Level A impermeable PPE.

A Study on the Characteristic Micro-Climate of Traditional Korean Houses using Computational Fluid Analysis (전산유체해석을 이용한 전통한옥 주변의 미기후 특성에 대한 연구)

  • Park, Min-Woo;You, Jang-Youl;Nam, Byung-Hee;You, Ki-Pyo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.22 no.4
    • /
    • pp.15-22
    • /
    • 2022
  • Micro-climate measurements and computational fluid analysis were conducted to use it as basic data for the preservation and management of the old house of Kim Myung-kwan, a traditional building that is National Folk Cultural Property No. 26. As a result of the actual measurement, the temperature and humidity are relatively evenly distributed indoors unlike outdoors, but the temperature and humidity vary depending on the time change and the installation location in the outdoors. It was found that the temperature increases after dawn and the temperature varies depending on the installation position around 14:00-15:00, when the temperature becomes the highest. In particular, the temperature was high at the outdoor measurement point adjacent to the building and the fence. As a result of the computational fluid analysis, the temperature was high in the buildings and fences in the old house or in the area adjacent to the building, and it was about 1℃ higher than the surrounding area. In this area, it is judged that the thickening of wood will occur more severely than in other locations, and special preservation management is required.

Vibration control of high-rise buildings for wind: a robust passive and active tuned mass damper

  • Aly, Aly Mousaad
    • Smart Structures and Systems
    • /
    • v.13 no.3
    • /
    • pp.473-500
    • /
    • 2014
  • Tuned mass dampers (TMDs) have been installed in many high-rise buildings, to improve their resiliency under dynamic loads. However, high-rise buildings may experience natural frequency changes under ambient temperature fluctuations, extreme wind loads and relative humidity variations. This makes the design of a TMD challenging and may lead to a detuned scenario, which can reduce significantly the performance. To alleviate this problem, the current paper presents a proposed approach for the design of a robust and efficient TMD. The approach accounts for the uncertain natural frequency, the optimization objective and the input excitation. The study shows that robust design parameters can be different from the optimal parameters. Nevertheless, predetermined optimal parameters are useful to attain design robustness. A case study of a high-rise building is executed. The TMD designed with the proposed approach showed its robustness and effectiveness in reducing the responses of high-rise buildings under multidirectional wind. The case study represents an engineered design that is instructive. The results show that shear buildings may be controlled with less effort than cantilever buildings. Structural control performance in high-rise buildings may depend on the shape of the building, hence the flow patterns, as well as the wind direction angle. To further increase the performance of the robust TMD in one lateral direction, active control using LQG and fuzzy logic controllers was carried out. The performance of the controllers is remarkable in enhancing the response reduction. In addition, the fuzzy logic controller may be more robust than the LQG controller.

Effects on Vegetation Distribution of Odaesan National Park according to Climate and Topography of Baekdudaegan, Korea

  • Han, Bong-Ho;Choi, Jin-Woo;Yeum, Jung-Hun
    • Journal of Environmental Science International
    • /
    • v.26 no.10
    • /
    • pp.1111-1124
    • /
    • 2017
  • This study aimed to understand the distribution of vegetation in the eastern and western sides of the Baekdudaegan (ridge) dividing the Odaesan National Park, as influenced by its topography and climate. The actual vegetation, topography and climate for each side were used in the overlay analysis. The results of the analysis of actual vegetation showed a high distribution rate of Quercus mongolica forest on both the eastern and western sides. On the eastern side, the distribution rate of Pinus densiflora forest and P. densiflora-Q. variabilis forest was high, while the western side had a high distribution rate of deciduous broad-leaved tree forest and Abies hollophylla forest. A clear trend was identified for vegetation distribution with respect to elevation but not with respect to slope or aspect. The results of micro-landform analysis showed that the P. densiflora forests in the ridge and slope and the deciduous broad-leaved tree forest in the valley were respectively distributed with a high ratio. In terms of climate, the eastern side revealed an oceanic climate, with a relatively high average annual temperature, while the western side was characterized by relatively high average annual humidity and average annual precipitation. The distribution rate of P. densiflora forest was found to be high on the eastern side of the mountain range.

Analysis of the Thermal Environment in the Laying House (산란계사내부 열환경 분석)

  • Kim Y. B.;Lee S. K.;Kim S. T.;La W. J.;Chang H. H.
    • Journal of Animal Environmental Science
    • /
    • v.11 no.3
    • /
    • pp.177-188
    • /
    • 2005
  • In this study, the thermal environmental factors in a layer f(arm such as dry bulb temperature, relative humidity, black globe temperature and illumination intensity were measured and analyzed to serve as basis for effective design and plan of poultry houses. The correlation analysis between the different factors was also done. Heat Index as measure of the thermal stress was also calculated and analyzed. A $1,000m^2$ laying house, 4 meters high with 52,000 layers in six-stage type cages was used in the measurement of the different environmental parameters. The results were as follows; 1. The temperature of the inside air and materials was directly related to the increase in aerial temperature based on the dry-bulb, black globe temperature reading. The correlation factor of the outside to inside air based on dry bulb setting was very significant at 0.927 The dry bulb temperature for inside temperature ranged from $19.9\~28.8^{\circ}C\;with\;SD+2.2^{\circ}C$ while that of the outside air was $16.2\~33.1^{\circ}C,\;SD+3.5^{\circ}C$. In addition, the temperature of the inside air was very stable. 2. The black globe temperature of the inside air ranged from $20.1\~28.8^{\circ}C,\;SD+2.3^{\circ}C$ while that of the outside air was $16.2\~47.5^{\circ}C,\;SD+6.0^{\circ}C$. 3. The relative humidity of the outside and inside air was $72.4\~100\;and\;50.2\~85.6\%$ with an average of $89.2\;and\;71.7\%$, respectively. 4. The illumination intensity in the laying house was less than 7 lux, with an average of $1.2\~2.5lux$ relative to height indicating that the laying house was well isolated from outside radiation. 5. The heat index of the inside air of the laying house had a high variation from $20.5^{\circ}C,\;SD+2.5^{\circ}C$ while that of the outside air was $13.1\~45.5^{\circ}C$, with an average of $21.6^{\circ}C,\;SD+6.3^{\circ}C$.

  • PDF

Study of Pallet Scale Modified Atmosphere Packaging Films for Reducing Water Condensation

  • Kim, Jinse;Park, Jong Woo;Park, Seokho;Choi, Dong Soo;Choi, Seung Ryul;Kim, Yong Hoon;Lee, Soo Jang;Park, Chun Wan;Lee, Jung- Soo;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • v.41 no.2
    • /
    • pp.98-107
    • /
    • 2016
  • Purpose: The aim of this study was to find an appropriate polymer film, which could reduce the water condensation for pallet-size modified atmosphere packaging (MAP). Methods: Five different types of films were selected from several commercialized films. Prior to the real food storage test, plastic boxes with wetted plastic balls were used to simulate the high humidity conditions of real food storage. The initial MAP condition was 5% oxygen and 95% nitrogen, and the $O_2$ concentration, the relative humidity and water condensation inside the films were checked on a daily basis. The MAP test for tomatoes was conducted by using the most appropriate film from the five films examined in this study. Results: Every film except Mosspack(R) indicated a similar variation in the $O_2$ concentration over the course of time. The relative humidity near the surfaces of all the films except nylon-6 approached saturation conditions over time. For three kinds of films, namely, low-density polyethylene (LDPE) film, anti-fogging oriented polypropylene (AFOPP) film, and Mosspack(R), the inner surfaces of the films were fully covered with dew after a storage period of a day. Conversely, an area of 4.5% was covered with dew in the case of the poly lactic acid (PLA) film, and there was no dew inside the nylon-6 film. The pallet-size MAP test for tomatoes was conducted by using the nylon-6 film and there was no water condensation inside the nylon-6 film over three weeks of storage. Conclusions: During the pallet scale MAP, water condensation could cause severe fungal infection and wetting of the corrugated box. Hence, it was important to minimize water condensation. This study showed that the MAP films with high WVTR such as nylon-6 and PLA could reduce the water condensation inside the pallet scale MAP.

The Physiological Responses and Subjective Sensation in the Subjects Wearing Dust-free Garment for Semiconductor Industrial Environments (방진복 착용에 따른 인체의 온열생리적 특성 및 주관적 감각)

  • 권오경;이창미
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1998.04a
    • /
    • pp.255-263
    • /
    • 1998
  • Dust-free garment prevents contamination which otherwise is caused by skin and clothes to protect from dust or dirt. Therefore, it requires high performance and should function as a working clothes. Clothes are a medium between human and thermal environmental system, and it is required to study human enviroment to ensure comfortableness of clothes and to satisfactorily go along with enviroment .This study investigates the physical and physiological features of dust-free garment used in the clean room at a semiconductor factory in oredr to scientifically clarify what the dust-free garmint is as well as to contribute to the design and development of high performance material and clothes. Three kinds of dust-free fabrics (DFG-I, DFG-II, DFG-III) which are being developed by a local company are used to manufacture dust-free garment. These dust-free garments are dressed and tested in such an enviroment as similar to semiconmemts with temperature at 23${\pm}$1$^{\circ}C$ and humidity at 50${\pm}$5%RH in order to investigate the thermo physiological and psychological features of human body. The results of this study are as follows. The results of this study are as follows. 1.The mean skin temperature was significantly different among the clothes, subjects and experimental time. Temperature tends to rise from the time of exercising load. Continuous motion coupled sealed clothes prevents heat transmittance, and temperature rises in the order of DFG-l, DFG-ll and DFG-lll as time course. 2.As for the skin temperature by local timperature is minimun on the head and torso and increares remarkably at the terminal part of human body. 3. As for the body mass loss was significantly higher in DFG-lll than DFG-l and DFG-ll. 4. Though there is no significant difference in the temperature within clothes among the kind of clothes temperature is 1$^{\circ}C$ higher in the back. Temperature within all the dust-free garments 29.7$^{\circ}C$ in the back and 31.3$^{\circ}C$ in the chest which belong to the comfort zone(31-33$^{\circ}C$). The relative humidity is 39.7%RH in the chest and 33.8%RH in the back which is slightly below the comfort zone(40-60%RH) 5. The thermal sensation belong to the comfort zone regardless of the kinds of clothes. The subjects feels a slight fatigue as times goes. As for the subjective sense of subjects the mean skin temperature as well as temperature and humidity within clothes show similar tendency. This means that they relate with each other.

  • PDF

Effect of Canopy Covering on Thermal Insulation and Freezing Tolerence of 'Shiranui' Hybrid Mandarin Cultivated in Field During Winter Season (수관 피복이 노지재배 '부지화' 감귤나무의 보온과 내한성에 미치는 영향)

  • Joa, Jae-Ho;Kang, Seok-Beom;Moon, Young-Eel;Lee, Hae-Jin
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.441-447
    • /
    • 2021
  • It were investigated changes in internal and external temperature, relative humidity using tyvek, weedstop, and 35% shading net as covering material to reduce the freezing damage of 'Shiranui' hybrid mandarin grown in open field. It were also evaluated canopy covering effect and LT50 of leaves by covering material when it was cold at -2℃. In tyvek, temperature difference between inside and outside was low at the height of 1.5m and was high at 0.4m. The relative humidity differed greatly between day and night, and was high at 6-8 a.m. At -2℃, Sum of temperature at the height of 1.5m of canopy for 24-hour after covering were at 3.4℃ higher in tyvek than in control. The LT50 of leaves was at 1.51℃ in tyvek, 1.33℃ in withstop, and 1.61℃ in 35% shading net lower than in control. Considering thermal insulation and relative humidity in canopy, tyvek is expected to reduce low temperature damage when covering after making a fine hole for ventilation.