• 제목/요약/키워드: High humidity

검색결과 1,699건 처리시간 0.028초

액화천연가스의 냉열을 이용한 가스터빈의 성능향상 (Improvement of Gas Turbine Performance Using LNG Cold Energy)

  • 김동섭;노승탁;이우일;최만수;고상근
    • 대한기계학회논문집B
    • /
    • 제23권5호
    • /
    • pp.653-660
    • /
    • 1999
  • This work describes analysis on the effect of inlet air cooling by the cold energy of liquefied natural gas(LNG) on the performance of gas turbines. Gas turbine off-design analysis program to simulate the influence of compressor inlet temperature variation is prepared and an inlet air cooler is modeled. It is shown that the degree of power augmentation is much affected by the humidity of inlet air. If the humidity is low enough, that is the water content of the air does not condense, the temperature drop amounts to $18^{\circ}C$, which corresponds to more than 12% power increase, in case of a $1350^{\circ}C$ class gas turbine with methane as the fuel. Even with 60% humidity, about 8% power increase is possible. It is found that even though the fuel contains as much as 20% ethane in addition to methane, the power improvement does not change considerably. It is observed that if the humidity is not too high, the current system is feasible oven with conceivable air pressure loss at the inlet air cooler.

습공기사이클 냉동시스템의 성능해석 (Performance Analysis of a Wet Air-Cycle Refrigeration System)

  • 원성필
    • 설비공학논문집
    • /
    • 제26권11호
    • /
    • pp.504-511
    • /
    • 2014
  • The objective of this study is to theoretically analyze the performance of an open wet air-cycle refrigeration system, which nowadays is increasingly generating environmental concern. The temperature and relative humidity of the outside air are selected as the most important parameters. As the temperature and relative humidity of the outside air increase, the pressure ratio of the ACM compressor is determined to be nearly constant, the air temperature at the exit of the system increases, and the amount of condensed water, the cooling capacity, the COP, and the total entropy production rate increase overall. The effects of the effectiveness of the heat exchanger and the efficiency of the turbine on the performance are greater than that of the efficiency of the ACM compressor. Also, the performance of the wet air-cycle refrigeration system with two heat exchangers is enhanced, with a high COP and low total entropy production rate, compared to the system with a single heat exchanger.

고분자 전해질 연료전지 멀티 스택 시스템의 수소극 흐름방향에 따른 습도분포 및 성능변화 (Humidity Distribution and Performance Variation of a PEMFC Multi Stack System According to the Direction of Anodic Supply)

  • 이용택
    • 설비공학논문집
    • /
    • 제30권3호
    • /
    • pp.143-148
    • /
    • 2018
  • In this study the performance and humidity variation for 2 unit cells connected in series were experimentally measured. The relative flow direction of hydrogen and air was changed from parallel flow to counter flow. Internal humidity distribution was then measured by 5 embedded sensors on each channel. In all experimental conditions, the former unit cell showed a better performance and the gap is noted to be higher when counter flow is applied. The performance was noted to be higher at high humidification case in the parallel flow. However, in the counter flow, the difference of performance according to the humidification is negligible. Hydrogen and air are discharged from the PEMFC unsaturated with water vapor at parallel flow/low humidification condition, which explains lower performance of the PEMFC than other conditions. The humidities in hydrogen and air streams of counter flow were noted to increase rapidly even at low humidification condition and the consequential even hydration of membrane is the reason of higher performance.

공기 중의 미세먼지에 의한 태양전지의 오염에 관한 연구 (A Study on the Contamination of Photovoltaic Cells by Fine Dust in the Air)

  • 한진목;최수광;김세웅;정영관
    • 한국수소및신에너지학회논문집
    • /
    • 제29권3호
    • /
    • pp.292-298
    • /
    • 2018
  • The contamination of photovoltaic (PV) cells reduces the incidence of sunlight and reduces the power generation output of PV cells. The main factor influencing the contamination of PV cells installed outdoors is the fine dust in the air, but the influence of temperature, humidity, rain and wind can be considered. In this paper, experiments on the contamination of PV cells according to the fine dust density, the temperature and humidity of air were investigated. As results of this study, the contamination area of PV cells increases with contamination time and cumulative fine dust density in the air. The contamination of PV cells increases when the temperature is low and the humidity is high. Also, as the contamination of PV cells is affected to the wind, the deviation of contamination area is happened.

습도가 버섯 성장에 미치는 상관관계 연구 (A Study of the Correlation Between the Growth of Mushroom and Humidity)

  • 서신림;이현창;윤려;신성윤
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 추계학술대회
    • /
    • pp.155-156
    • /
    • 2015
  • 버섯은 높은 단백질, 낮은 칼로리 있으면서 풍부한 비타민, 미네랄 등을 포함해서 건강식품으로 큰 주목을 받고 있다. 버섯은 인공재배 시에 온도 이외의 또 하나 중요한 요소는 습도이다. 현재 연구 중에 버섯과 온도의 상관관계에 대한 연구 많으며 버섯과 습도의 상관관계에 대한 연구를 상대적인 부족하다. 본 논문에서는 각 습도별에 버섯의 생장상태에 대한 관찰하고 분석한다. 버섯의 수율 및 품질을 개선하기 위해 데이터를 제공할 수 있다.

  • PDF

한지닥 섬유제품의 인체 생리 반응 및 쾌적성 평가 (Evaluation of Thermal Physiological Responses and Comfort in Dox Fabric)

  • 임순
    • 복식
    • /
    • 제63권5호
    • /
    • pp.102-114
    • /
    • 2013
  • This study performed the evaluation of skin temperature, heart rate, humidity and temperature inside clothing, and subjective sensation to estimate the physiological responses of the human body and its feeling of comfort for developing value-added dox fabric. Experiments were performed on five healthy adult women whose average age was 21, at climate chamber in which temperature, relative humidity and air current were set up below $28{\pm}5^{\circ}C$, $50{\pm}10%$, 0.2m/s, respectively. Two kinds of clothes were used for the experiments: 100% cotton and dox clothes. The clothes were identical in size and form, and the attire consisted of long-sleeved shirts, long trousers, and socks. The experiment was performed for 30 minutes using ergometer. The results are as follows. 1) It showed low skin temperature of forearm, breast, back, forehead and lower leg in exercise, but high skin temperature of them in recovery. However skin temperature of thigh and foot increased from rest to recovery. 2) It showed significant difference (p<0.001, p<0.01) in average skin temperature between cotton and dox clothes. Cotton clothes had a higher average skin temperature compared to dox. Not only was there a significant difference in temperature inside clothing (p<0.001), this was also the case with humidity inside the clothing (p<0.001).

공조기가 설치된 고분 내에서의 열 및 음 환경 평가 (Evaluation of the Thermal and Noise Environment in an Ancient Tomb installed a Duct-type HVAC System)

  • 박진양;전희호;전용두;이금배
    • 설비공학논문집
    • /
    • 제19권3호
    • /
    • pp.228-234
    • /
    • 2007
  • Opening an ancient tomb interior can deal fair damage for preservation in long period because of high moisture. In this study, a duct-type HVAC system was installed to preserve an ancient tomb and temperature and humidity was measured to analyze heat environment. Armhole was measured to search whether an ancient tomb receives effects of vibration caused by a duct-type HVAC system. According to the measured data, temperature in an ancient tomb is kept adaptively in conservation regardless of a duct-type HVAC system installation when it rains in summer. The other side, humidity is kept adaptively in conservation when installed duct-type HVAC system. But when it is in natural state, a lot of humidity by dew condensation phenomena. So it needs a duct-type system for an ancient tomb conservation. In the case of vibration, measurement value of 3 satisfy control but Germanic DIN 4150 does not satisfy. Therefore, equip must be such that it can prevent vibration for safety.

폴리이미드가 코팅된 광섬유 브래그 격자를 이용한 습도센서 (Humidity Sensor Using Polyimide Film Coated Fiber Bragg Grating)

  • 양재창;김건표;김광택
    • 한국전기전자재료학회논문지
    • /
    • 제36권6호
    • /
    • pp.594-597
    • /
    • 2023
  • We have proposed and demonstrated a fiber optic RH (relative humidity) sensor based on fiber Bragg grating covered with a polyimide film. As the polyimide film absolves the moisture in the air, its volume expands. As a result, the grating period of the FBG (fiber Bragg grating) covered with a polyimide film becomes wide and the Bragg wavelength is shifted. The sensor is implemented by fixing a 30 ㎛ thickness polyimide film on the surface of an optical fiber grating using an adhesive, and the characteristics of the device according to humidity are analyzed. The fabricated FBG RH sensor showed a high sensitivity of 0.0186 nm/RH% and a wide measurement range from 30% to 90%. The influence of environmental temperature on the characteristics of the RH sensor was also measured and analyzed. The feasibility of commercialization is presented.

동절기 대향류형 환기장치의 온실 내 습도 조절 효과 분석 (Analysis on the Effect of Greenhouse Humidity Control by Counter-flow Ventilator in Winter)

  • 이태석;강금춘;장재경;백이;임류갑
    • 생물환경조절학회지
    • /
    • 제29권3호
    • /
    • pp.259-264
    • /
    • 2020
  • 본 연구에서는 겨울철 보온으로 인해 야간 및 새벽에 상대습도가 높아지는 온실에 대향류형 환기장치를 설치하고 그 효과를 분석하였다. 대향류형 환기장치는 크기 0.96×0.65×0.82(W×D×H, m)의 케이스에 크기 0.54×0.40×0.75(W×D×H, m)의 PE소재의 열교환 소자와 급기와 배기를 위한 송풍팬(풍량 6,800㎥/h, 소비전력1.7kW) 2대가 내부에 있다. 환기장치는 총 2대를 이용하였으며 토마토의 적정 생육 환경을 고려하여 설정 습도를 80%하고 18시부터 익일 8시까지 온실 내 온도 및 습도를 측정하고 분석하였다. 관행 온실에서 야간 평균 온도 및 습도는 14.9℃, 82.8%, 시험구 온실에서 야간 평균 온습도는 15.1℃, 79.9%로 측정되어 온도는 0.1℃, 습도는 약 3% 차이가 났다. 온실 평균 온도 및 습도를 월별로 비교하고 독립표본 t검정을 통해 분석해 본 결과, 유의수준 1%에서 각 월의 온도는 차이가 없는 것으로 나타났으며 습도는 차이가 있다고 판단된다. 따라서 대향류형 환기장치의 사용이 온실의 습도를 관리하고 작물 생육에 적합환 환경을 조성하여 작물 생산성 향상에 도움을 줄 수 있다고 판단된다. 이 외에도 환기장치 사용에 따른 난방비 증가와 같은 손실적 요소와 이익적 요소를 복합적으로 고려한 추가적인 연구도 필요할 것으로 사료된다.

전산유체해석과 실측을 이용한 도심내 미기후 특성에 대한 연구 (A Study on the Characteristic Micro-Climate in the City using Computerized Fluid Analysis and Actual Measurement)

  • 유장열;박민우
    • 한국공간구조학회논문집
    • /
    • 제23권1호
    • /
    • pp.35-43
    • /
    • 2023
  • Microclimate analysis was conducted through actual measurement according to land use status in urban, and CFD analysis was conducted to analyze and predict the microclimate characteristics of urban, and compared and analyzed with the actual measurement results. It was measured in high-rise areas and parks, and the temperature of the park area was 0.4 to 0.6℃ lower, and the relative humidity was 1.0 to 3.0% higher. The correlation coefficient was obtained by comparing the results of the computational fluid analysis with the results of the computational fluid analysis at the actual location located within the CFD analysis area for validation. The seasonal correlation coefficients are all higher than 0.8, so it is judged that they can be applied to microclimate analysis in urban area. The computational fluid analysis was divided into three areas (low-rise, low and high-rise, and high-rise) centered on the A2 point. On average, the low-rise area was 0.1 to 0.4% higher than the high-rise area. In the low and high-rise area and high-rise area, the pith of buildings are wide, so the airflow is smooth, so it is judged that the temperature is relatively low.