• 제목/요약/키워드: High humidity

검색결과 1,699건 처리시간 0.033초

이부자리의 보온력에 관한 연구( I ) -충전물의 보온성 - (Studies on the Thermal Insulation Effect of Bedding ( I ) - Warmth Retaining Property of Filling Material -)

  • 이송자;성수광
    • 한국의류학회지
    • /
    • 제16권3호
    • /
    • pp.251-256
    • /
    • 1992
  • As a basic expriment to find out the thermal insulation effect of bedding KES-F7 was used to measure. The warmth retaining ratio of the six kinds of filling materials as cotton, wool , silk, down, cotton/polyester was measured, and the infleunce on the warmth retaining ratio of the warmth retaining ratio and humidity by the material was investigated. The results obtained are as follows: 1. The warmth retaining ratio of each filling material was shown to range from $70\%$ to $77\%$ . The warmth retaining ratio of each material preyed to be high in order down> polyester> cotton/polyester>cotton>silk>wool fiber. 2. The warmth retaining ratio of each filling material decreased with the inclose of the humidity The effective reduction rate by filling fiber's was high in order wool>cotton>cotton/polyester>silk>down>polyester material. 3. The warmth retaining ratio of each filling material was shown to be in counter-correlation with the humidity, and the correlation coefficient (r=0.94-0.98) proved to be highly signi-ficant.

  • PDF

국지예보모델에서 고해상도 마이크로파 위성자료(MHS) 동화에 관한 연구 (A Study on the Assimilation of High-Resolution Microwave Humidity Sounder Data for Convective Scale Model at KMA)

  • 김혜영;이은희;이승우;이용희
    • 대기
    • /
    • 제28권2호
    • /
    • pp.163-174
    • /
    • 2018
  • In order to assimilate MHS satellite data into the convective scale model at KMA, ATOVS data are reprocessed to utilize the original high-resolution data. And then to improve the preprocessing experiments for cloud detection were performed and optimized to convective-scale model. The experiment which is land scattering index technique added to Observational Processing System to remove contaminated data showed the best result. The analysis fields with assimilation of MHS are verified against with ECMWF analysis fields and fit to other observations including Sonde, which shows improved results on relative humidity fields at sensitive level (850-300 hPa). As the relative humidity of upper troposphere increases, the bias and RMSE of geopotential height are decreased. This improved initial field has a very positive effect on the forecast performance of the model. According to improvement of model field, the Equitable Threat Score (ETS) of precipitation prediction of $1{\sim}20mm\;hr^{-1}$ was increased and this impact was maintained for 27 hours during experiment periods.

농작물 육성에 필요한 습도 자동조절 환경 구축에 관한 연구 (A Study of Constructing the Environment to Adjust the Humidity Automatically)

  • 서신림;이현창;신성윤
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 추계학술대회
    • /
    • pp.147-148
    • /
    • 2015
  • 농업은 고 수율, 고 품질, 안전적인 지속적으로 발전하기 위해 과학 기술을 이용하면서 농업 생산, 가공, 유통이 정보화 지능화 시키고 표준화 관리 시스템을 구축해야한다. 이를 이루기 위해 농사 모니터링 시스템에 대한 연구를 많아지고 있는 반면에 일반 농가들은 비닐하우스로 농작물 재배 시에 여전히 전통적인 수공 측정 방식으로 습도를 측정하고 있다. 이런 문제를 해결하기 위해 본 논문에서는 센서, 디스플레이 장치 등을 결합하며 자동 습도 조절 환경을 구축한다.

  • PDF

고추 탄저병 Colletotrichum gloeosporioides의 병반 및 분생자층 형성에 미치는 온도, 상대습도 및 수분 지속기간의 영향 (Effect of Temperature, Relative Humidity, and Free Water Period on Lesion Development and Acervulus Formation of Colletotrichum gloeosporioides on Red Pepper)

  • 박경석;김충회
    • 한국식물병리학회지
    • /
    • 제10권1호
    • /
    • pp.34-38
    • /
    • 1994
  • Effect of temperature, relative humidity (RH) and free water period on anthracnose development by Colletotrichum gloeosporioides was examined on red pepper fruits. Mycelial growth of C. gloeosporioides was best at 28$^{\circ}C$, but greatly retarded at 32$^{\circ}C$. Minimum inoculum density required for lesion development varied with isolates, but was mostly above 1.0$\times$105 conidia/ml. Optimum temperature for lesion development on fruits was 31$^{\circ}C$. Percentage of lesion development was decreased as incubation temperature decreased. similar trend of temperature response was observed for acervulus formation on the developed lesions. Acervuli were not developed on the lesion as low as at 19$^{\circ}C$. Lesion development and acervuli formation tended to increase as increasing RH, but were greatly inhibited at the RH lower than 88%. More than 2 hours of free water period after inoculation were required for lesion development. Lesion development was increased as free water period increased. This study indicates that anthracnose development by C. gloeosporioides favors the conditions of high temperature above 28$^{\circ}C$, high humidity above 90% RH, and requires free water period longer than 2 hours.

  • PDF

Effects of Temperature and Humidity on Fungal Occurrence in Dried Red Pepper during Storage

  • Kim, Sosoo;Baek, Seul Gi;Hung, Nguyen Bao;Kim, Se-Ri;Jang, Ja Yeong;Kim, Jeomsoon;Lee, Theresa
    • 식물병연구
    • /
    • 제27권4호
    • /
    • pp.155-163
    • /
    • 2021
  • Dried red peppers are frequently contaminated with mycotoxins during storage. To determine the effect of storage environments on fungal occurrence and subsequent mycotoxin accumulation in dried red peppers, we monitored red pepper powder and whole fruit samples for fungal occurrence under various temperatures and relative humidity (RH) conditions during 340 days. Fungal occurrences fluctuated in both pepper forms throughout the storage but they were higher in pepper powder than whole one, higher under low temperatures (-20℃, 0℃, or 4℃) than others (10℃, 25℃, or 30℃), and higher under RH 93% than RH 51% and 69% in both peppers. The samples exhibiting high fungal occurrences were associated mainly with dominant species such as Aspergillussydowii, Penicillium solitum, P. roqueforti, P. polonicum, or P. chrysogenum. Mycotoxigenic species, including A. flavus, A. ochraceus, A. westerdijkiae, A. tubingensis, and P. citrinum, were also detected throughout the samples. Although mycotoxins were not detected in the samples, mycotoxigenic potential of A. flavus, A. ochraceus, and A. westerdijkiae isolates were confirmed. These results show that low temperatures (-20℃, 0℃, or 4℃) and/or high surrounding RH (>93%) are not safe environments for storage of dried red peppers as fungal growth can occur under these conditions.

실내 미세먼지 측정을 위한 저가형 PM 센서의 실험실/현장 평가 및 보정 방법 (Laboratory/Field evaluation and calibration method of low-cost PM sensor for indoor PM2.5, PM10 measurement)

  • 김도헌;신동민;황정호
    • 한국입자에어로졸학회지
    • /
    • 제18권4호
    • /
    • pp.109-127
    • /
    • 2022
  • Recently, low-cost particulate matter (PM) sensors have been widely used in monitoring mass concentration. Maintaining the accuracy of the sensors is important and requires rigorous performance evaluation and calibration. In this study, two commercial low-cost PM sensors(LCS), Plantower PMS3003 and Plantower PMS7003, were evaluated in the laboratory and field with a reference-grade PM monitor (GRIMM 11-D). Laboratory evaluation was conducted with single/mixed particles of PSL (Poly Styrene Latex) in an acrylic chamber at 20℃ and relative humidity of 20%. Field evaluation was conducted inside a building of Yonsei University (Shinchon) from February 12 to March 31, 2022. In both evaluations, LCS measured values became different from reference measured values when the relative humidity was high or the outdoor air PM10/PM2.5 ratio was high. Based on the field evaluation, the LCS measured values were corrected through four different regression analysis models. As a result, the multivariate polynomial regression analysis model showed highest matching with the reference PM monitor (PM2.5 >0.9, PM10 >0.85). In this model, the PM10/PM2.5 ratio and relative humidity were chosen as independent variables.

Simulation of the Air Conditioning System Using Fuzzy Logic Control

  • Mongkolwongrojn, M.;Sarawit, W.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2270-2273
    • /
    • 2003
  • Fuzzy logic control has been widely implemented in air conditioning and ventilation systems which has uncertainty or high robust system. Since the dynamic behaviors of the systems contain complexity and uncertainty in its parameters , several fuzzy logic controllers had been implemented to control room temperature in the field of air conditioning system. In this paper, the fuzzy logic control has been developed to control room temperature and humidity in the precision air conditioning systems. The nonlinear mathematical model was formulated using energy and continuity equations. MATLAB was used to simulate the fuzzy logic control of the multi-variable air conditioning systems. The simulation results show that fuzzy logic controller can reduce the steady-state errors of the room temperature and relative humidity in multivariable air conditioning systems. The offset are less than 0.5 degree Celsius and 3 percent in relative humidity respectively under random step disturbance in heating load and moisture load respectively

  • PDF

Development of Ceramic Humidity Sensor for the Korean Next Generation Reactor

  • Lee, Na-Young;Hwang, Il-Soon;Yoo, Han-Ill;Song, Chang-Rock
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 추계학술발표회논문집(1)
    • /
    • pp.183-190
    • /
    • 1996
  • Leak-before-break(LBB) approach has been shown to be both cost and risk effective by reducing maintenance cost and occupational exposure when applied to high energy piping in nuclear power plants. For Korean Next Generation Reactor(KNGR) development, LBB is considered for the Main Steam Line(MSL) piping inside containment. Unlike the reactor coolant piping leakages which can be detected by particulate and gaseous radiation monitoring, main steam line leak detection systems must be based on principles that do not involve radioactivity. Ceramics are widely used as humidity sensor materials which can be further developed for nuclear applications. In this paper, we describe the progress in the development of ceramic humidity sensors for use with the main steam lines of KNGR.

  • PDF

기후요소가 건설안전사고에 미치는 영향에 관한 연구 (A Study on the Influence of Climate Factors on Construction Accidents)

  • 손창백;김상철
    • 한국안전학회지
    • /
    • 제20권2호
    • /
    • pp.91-97
    • /
    • 2005
  • The purpose of this study is to provide basic data for establishment of prevention counterplan against construction accidents in preparation for variation of climate conditions. In order to execution of this study, it was analyzed relations of climate factors and cases of construction accident occurred construction sites. In occurrence of construction accidents inducing death upon variation of Climate factors, precipitation and wind velocity were not related directly to construction accidents inducing death. On the other hand, the more temperature and humidity are high, the more construction accidents inducing death occurred. Especially, when temperature and humidity are above $24^{\circ}C,\;70\%$ respectively, field managers must pay attention to safety management of construction sites.

Implementation of Fuzzy Logic Control for Air Conditioning Systems

  • Mongkolwongrojn, M.;Sarawit, V.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1264-1267
    • /
    • 2005
  • Fuzzy logic control has been widely applied for handling the system which has uncertainty or high robust system. Since the dynamic behaviors of the systems contain complexity and uncertainty in its parameters, several fuzzy logic controllers have been implemented to control room temperature in the field of air conditioning system. In this paper, the fuzzy logic control has been developed to control both in door temperature and humidity in the air conditioning systems. The manipulating variables are speed of compressor, heater and supply air flow rate. The microcomputer was used to interface with in system. The experimental results show the superior of multivaiable fuzzy logic control to keep room temperature and humidity in air conditioning system for the best comfortable.

  • PDF