• Title/Summary/Keyword: High heart rates

Search Result 123, Processing Time 0.032 seconds

Recent advances in pediatric interventional cardiology

  • Kim, Seong-Ho
    • Clinical and Experimental Pediatrics
    • /
    • v.60 no.8
    • /
    • pp.237-244
    • /
    • 2017
  • During the last 10 years, there have been major technological achievements in pediatric interventional cardiology. In addition, there have been several advances in cardiac imaging, especially in 3-dimensional imaging of echocardiography, computed tomography, magnetic resonance imaging, and cineangiography. Therefore, more types of congenital heart diseases can be treated in the cardiac catheter laboratory today than ever before. Furthermore, lesions previously considered resistant to interventional therapies can now be managed with high success rates. The hybrid approach has enabled the overcoming of limitations inherent to percutaneous access, expanding the application of endovascular therapies as adjunct to surgical interventions to improve patient outcomes and minimize invasiveness. Percutaneous pulmonary valve implantation has become a successful alternative therapy. However, most of the current recommendations about pediatric cardiac interventions (including class I recommendations) refer to off-label use of devices, because it is difficult to study the safety and efficacy of catheterization and transcatheter therapy in pediatric cardiac patients. This difficulty arises from the challenge of identifying a control population and the relatively small number of pediatric patients with congenital heart disease. Nevertheless, the pediatric interventional cardiology community has continued to develop less invasive solutions for congenital heart defects to minimize the need for open heart surgery and optimize overall outcomes. In this review, various interventional procedures in patients with congenital heart disease are explored.

Efficiency of MVP ECG Risk Score for Prediction of Long-Term Atrial Fibrillation in Patients With ICD for Heart Failure With Reduced Ejection Fraction

  • Levent Pay;Ahmet Cagdas Yumurtas;Ozan Tezen;Tugba Cetin;Semih Eren;Goksel Cinier;Mert Ilker Hayiroglu;Ahmet Ilker Tekkesin
    • Korean Circulation Journal
    • /
    • v.53 no.9
    • /
    • pp.621-631
    • /
    • 2023
  • Background and Objectives: The morphology-voltage-P-wave duration (MVP) electrocardiography (ECG) risk score is a newly defined scoring system that has recently been used for atrial fibrillation (AF) prediction. The aim of this study was to evaluate the ability of the MVP ECG risk score to predict AF in patients with an implantable cardioverter defibrillator (ICD) and heart failure with reduced ejection fraction in long-term follow-up. Methods: The study used a single-center, and retrospective design. The study included 328 patients who underwent ICD implantation in our hospital between January 2010 and April 2021, diagnosed with heart failure. The patients were divided into low, intermediate and high-risk categories according to the MVP ECG risk scores. The long-term development of atrial fibrillation was compared among these 3 groups. Results: The low-risk group included 191 patients, the intermediate-risk group 114 patients, and the high-risk group 23 patients. The long-term AF development rate was 12.0% in the low-risk group, 21.9% in the intermediate risk group, and 78.3% in the high-risk group. Patients in the high-risk group were found to have 5.2 times higher rates of long-term AF occurrence compared to low-risk group. Conclusions: The MVP ECG risk score, which is an inexpensive, simple and easily accessible tool, was found to be a significant predictor of the development of AF in the long-term follow-up of patients with an ICD with heart failure with reduced ejection fraction. This risk score may be used to identify patients who require close follow-up for development and management of AF.

Treatment of Failed Arthrodesis of First Metatarsophalangeal Joint with Tensor Fascia Lata Interposition Arthroplasty: A Case Report (실패한 제 1중족 족지관절 유합술 후 대퇴근막 장근 개재 관절 성형술을 이용한 치료: 증례 보고)

  • Sim, Jaewoo;Hyun, Yoonsuk;Park, Junsik;Kang, Saehyun;Kwon, Hwanjin;Kim, Gablae
    • Journal of Korean Foot and Ankle Society
    • /
    • v.21 no.1
    • /
    • pp.39-42
    • /
    • 2017
  • Surgical treatments for arthritis in the first metatarsophalangeal joint include arthrodesis, interposition arthroplasty using silicone or meniscus cartilage, and rarely arthroplasty. Although arthrodesis was performed successfully, pain can persist if the angle of fusion was inappropriate. Interposition arthroplasty can be tried for the treatment of persisting pain after the arthrodesis. Interposition arthroplasty using tensor fascia lata is known that has low risk of adhesions and easy to harvest. Compared to autologous grafts, grafting rates is high and low risk of rejection additionally. Herein, we report a successfully managed arthritis with severe pain with interposition arthroplasty using tensor fascia lata after a failed metatarsophalangeal joint arthrodesis.

The Effect of Additives in the Cardioplegic Solution on the Recovery of Myocardium, Compariosn Among Albumin, Mannitol, and Glucose (심마비용액의 삼투압을 유지하기위한 첨가 물질들의 차이가 심근보호에 미치는 영향)

  • Kim, Eun-Gi;Lee, Jong-Guk;Lee, Sang-Heon
    • Journal of Chest Surgery
    • /
    • v.24 no.11
    • /
    • pp.1058-1067
    • /
    • 1991
  • High potassium cardioplegia is a widely accepted procedure to enhance myocardial protection from ischemic injuries associated with open heart surgery. Maintaining optimum osmolarity of the cardioplegic solution is one of the required conditions for an ideal cardioplegic solution Albumin is an frequently added component for maintaining optimum osmolarity of clinically used cardioplegic solutions. But the source of albumin is human blood so that the supply is limited and the cost of manufacturing is relatively high. Recently there are moves to minimized the use of blood product for fear of blood-associated infections or immunological disorders. In this experiment, we substituted mannitol or glucose for albumin added to the cardioplegic solution which has been used at the Wonju Medical College, To determine whether addition of mannitol or glucose instead of albumin in the cardioplegic solution can produce satisfactory myocardial protection during ischemia, three different groups of isolated rat heart perfused by modified Langendorff technique were studied. Wonju Cardioplegic Solution was selected as a standard high potassium[18mEq/L of K+] cardioplegic solution. Three kinds of cardioplegic solution were made by modifying the composition maintaining the same osmolarity[339$\pm$1mOsm/Kg] Isolated rat heart were perfused initially with retrograde nonworking mode and then changed to working mode. After measuring the heart rate, systolic aortic pressure, aortic flow, coronary flow, ischemic arrest by aorta cross clamp and cardioplegia was made maintaining the temperature of water jacket at 10oC. The heart was rewarmed and reperfused after 60min of ischemic arrest with intermittent cardioplegia at the 30min interval. The time to return of heart beat and the time required to get. Regular heart beat were observed after reperfusion. The recovery rate of the functional variables-heart rate, systolic aortic pressure, aortic flow, coronary flow and cardiac output were calculated and compared among the three groups of different cardioplegia-albumin, mannitol, and glucose. The wet weight and dry weight was measured and the water content of the heart as figured out for comparison. The time to return of heart beat was fastest in the albumin group, The functional recovery rates were best in the albumin group also. In the above conditions, albumin was the best additive to the cardioplegic solution compared to the mannitol or glucose.

  • PDF

Development of algorithm for work intensity evaluation using excess overwork index of construction workers with real-time heart rate measurement device

  • Jae-young Park;Jung Hwan Lee;Mo-Yeol Kang;Tae-Won Jang;Hyoung-Ryoul Kim;Se-Yeong Kim;Jongin Lee
    • Annals of Occupational and Environmental Medicine
    • /
    • v.35
    • /
    • pp.24.1-24.15
    • /
    • 2023
  • Background: The construction workers are vulnerable to fatigue due to high physical workload. This study aimed to investigate the relationship between overwork and heart rate in construction workers and propose a scheme to prevent overwork in advance. Methods: We measured the heart rates of construction workers at a construction site of a residential and commercial complex in Seoul from August to October 2021 and develop an index that monitors overwork in real-time. A total of 66 Korean workers participated in the study, wearing real-time heart rate monitoring equipment. The relative heart rate (RHR) was calculated using the minimum and maximum heart rates, and the maximum acceptable working time (MAWT) was estimated using RHR to calculate the workload. The overwork index (OI) was defined as the cumulative workload evaluated with the MAWT. An appropriate scenario line (PSL) was set as an index that can be compared to the OI to evaluate the degree of overwork in real-time. The excess overwork index (EOI) was evaluated in real-time during work performance using the difference between the OI and the PSL. The EOI value was used to perform receiver operating characteristic (ROC) curve analysis to find the optimal cut-off value for classification of overwork state. Results: Of the 60 participants analyzed, 28 (46.7%) were classified as the overwork group based on their RHR. ROC curve analysis showed that the EOI was a good predictor of overwork, with an area under the curve of 0.824. The optimal cut-off values ranged from 21.8% to 24.0% depending on the method used to determine the cut-off point. Conclusion: The EOI showed promising results as a predictive tool to assess overwork in real-time using heart rate monitoring and calculation through MAWT. Further research is needed to assess physical workload accurately and determine cut-off values across industries.

Surgical Experience of the Ruptured Distal Anterior Cerebral Artery Aneurysms

  • Lee, Jong-Young;Kim, Moon-Kyu;Cho, Byung-Moon;Park, Se-Hyuck;Oh, Sae-Moon
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.4
    • /
    • pp.281-285
    • /
    • 2007
  • Objective : Distal anterior cerebral artery (DACA) aneurysms are fragile and known to have high risks for intraoperative premature rupture and a relatively high associated morbidity. To improve surgical outcomes of DACA aneurysms, we reviewed our surgical strategy and its results postoperatively. Methods : A total of 845 patients with ruptured cerebral aneurysms were operated in our hospital from January 1991 to December 2005. Twenty-three of 845 patients had ruptured DACA aneurysms which were operated on according to our surgical strategy. Our surgical strategy was as follows; early surgery, appropriate releasing of CSF, appropriate surgical approach, using neuronavigating system, securing the bridging veins, using temporary clipping and/or tentative clipping, meticulous manipulation of aneurysm, and using micro-Doppler flow probe. Twenty of 23 patients who had complete medical records were studied retrospectively. We observed the postoperative radiographic findings and checked Glasgow Outcome Scale score sixth months after the operation. Results : Nineteen DACA aneurysms were clipped through a unilateral interhemispheric approach and one DACA aneurysm was clipped through a pterional approach. Postoperative radiographic findings revealed complete clipping of aneurysmal neck without stenosis or occlusion of parent arteries. In two patients, a residual neck of aneurysm was visualized. Seventeen patients showed good recovery, one patient resulted in moderate disability, while 2 patients died. Conclusion : With our surgical strategy it was possible to achieve acceptable surgical morbidity and mortality rates in patients with DACA aneurysms. Appropriate use of tentative clipping, temporary clipping and neuro-navigating systems can give great help for safe approach and clipping of DACA aneurysm.

Effects of Soaansintang(SOAT) on the hemodynamics and electrocardiogram of isolated rat hearts induced by electrical stimulation (소아안신탕(小兒安神湯)이 STRESS를 유발한 흰쥐의 적출심장(摘出心臟)에 미치는 영향)

  • Lee Seung-Jun;Lee Jin-Yong;Kim Deok-Gon
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.14 no.2
    • /
    • pp.1-32
    • /
    • 2000
  • It has long been known that SOAT is effective for sudden palpitation occurring unexpectedly in Oriental Medicine. However, effect of SOAT on the isolated heart has not been studied yet. The purpose of this study is to investigate the effect of SOAT on hemodynamics and ECG of isolated rat hearts induced by electrical stimulation using Langendorff perfusion apparatus for nonworking heart. SOAT extract was manufactured by water-alcohol precipitated method. Sprague-Dawley rats weighting $120{\sim}150g$ were used for the experiments, Subject animals were divided into four groups, which are consisted of 1) control(Group orally administered by normal saline 1ml for 14days), 2) sample A(Group orally administered by SOAT extract 1ml for 14days), 3) sample C(Group injected by SOAT extract 0.5ml after stimulation, 4) sample C(Group injected by SOAT extract 1ml after stimulation. To evluate the effects of SOAT on hemodynamics and ECG of isolated rat heart induced by stimulation, heart rate, left ventricular pressure, systolic power, diastolic power, coronary artery perfusion volume and ECG were measured using Langendorff apparatus in both stimulation mode(5 volts, 450 beats/min) and arrythmic mode(5 volts, 420 beats/min including 60 beats/min) The results obtained are as follows : 1. After receiving stressful electrical stimuli, isolated heart showed the heart rate, left ventricular pressure, systolic power, diastolic power, coronary artery perfusion volume were all decreased temporarily, but perfusion continued longer recovery to the control state appeared. However, the coronary artery perfusion volume diminished continuously. 2. The heart rates did not change significantly with both stimulation mode and arrhythmic mode, among experimental groups. 3. The left ventricular pressure showed with both stimulation mode and arrhythmic mode, the significant changes(p<0.05) especially in the injection sample group. In case of stimulation mode, low concentration injection group(0.5ml) was more significantly increased rather than high concentration group(1ml) and in case of arrhythmic mode, high density group(1ml) was so increased than the other(0.5ml). 4. For the systolic power and diastolic power, no significant changes were noticed in the stimulation mode, but in the arrhythmic mode of injection sample groups, significant change(p<0.05) was noticed in both systolic power and diastolic power. Specially the high concentration group(1ml) showed more significant increase than the low concentration group. 5. For the coronary artery perfusion volume, no significant change difference among sample groups was observed in both the stimulation mode and the arrhythmic mode. 6. For the ECG recordings, arrhythmia was induced by electrical stimulus of arrythmia mode and after the stimulus was removed, irregular wave appeared temporarily, but as perpusion continued, recovery to the control state was abtained like the stimulation mode. According to the above results, SOAT significantly changed the hemodynamic data from the electrically stressed, isolated hearts of connected Langendorff perfusion apparatus and we propose SOAT has the direct effects on the muscular function of heart.

  • PDF

Recent Mortality Trends in Korea (최근(最近) 한국인(韓國人)의 사망력(死亡力) 경향(傾向)에 관(關)한 고찰(考察))

  • Kim, Il-Soon;Lee, Dong-Woo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.2 no.1
    • /
    • pp.61-76
    • /
    • 1969
  • A review has been made of mortality trends in Korea from 1958 to 1967 analyzing the data by sex, age and cause of death. The crude death rates and age specific death rates were estimated by the model of N. Keyfitz life table which had been developed by the data of the 1960's national census. The cause specific death rates shown in this article are based on the following: all deaths occurring in the death-registration are expressed as a numberator, while the denominator was estimated from the regular national census data by interpolation method. It is estimated that only an average of about 40% of deaths which occurred during a year were registered during 1958 to 1967. The validity and the reliability of the diagnosis of causes of death seem to be extremely poor in this country. Therefore the cause specific death rates in this article are aimed to reveal trends of causes of registered death ana not for the actual level of death rates. For 10 years very interesing mortality trends were observed : 1. The trend in the crude death rates was downward slowly. 2. The estimated death rate for the infant in 1960 was still high up to 100 per 1,000. 3. The rates for mortality attributed to such infectious diseases as pneumonia, bronchitis, gastroenteritis and measles decreased an average 40-60%. 4. The death rates for over-all tuberculosis decreased only 9.8%. 90% of the decrease was contributed by those in the less-than-15 year age group. 5. The death rates for chronic diseases, such as vascular diseases affecting the central nervous system, malignant neoplasm, major heart diseases and all accidents rose about 40-60%. 6. The rank order of the 10 leading causes of death showed large changes over the years, except for pneumonia and tuberculosis which occupyed 1st and 2nd places respectively. Vascular diseases affecting the central nervous system moved from 5th to 3rd place and malignant neoplasm from 6th to 4th place, The major heart diseases moved from 10th to 6th place and all accidents from 10th to 7th place. On tile other hand, gastroenteritis moved from 3rd to 5th place and influenja from 4th to 8th place.

  • PDF

Wireless Bio-Signal Sensing System Using a Circular Polarized Antenna

  • Kwon Young-Bae;Park Jung-Min;Choe Jung-Hwan;Park Seong-Ook;Ishida Osami
    • Journal of electromagnetic engineering and science
    • /
    • v.5 no.3
    • /
    • pp.132-139
    • /
    • 2005
  • Wireless bio-signal sensing system, which is based on the principle of Doppler radar, can measure a respiration and heart rates with a periodic movement of skin and muscle near the heart. Though the sensing monostatic system using a circulator has been studied, this bistatic system can be improved by using a circular polarized antenna which has a high isolation between transmitter and receiver. In this paper, we measured the bio-signal without the direct contact with the person. The design of each system and experimental results are discussed.

Irrigation-suction System for Management of Deep Sternal Wound Infection after Open Heart Surgery -Four cases- (개심술 후 발생한 심부 흉골 창상감염의 세척-흡입법을 이용한 치험 -4예 보고-)

  • 김상익;오상준
    • Journal of Chest Surgery
    • /
    • v.36 no.6
    • /
    • pp.431-435
    • /
    • 2003
  • Deep sternal wound infection (with or without acute mediastinitis) is a serious complication of open heart surgery, with high rates of associated morbidity and mortality, and prolonged hospitallization. The result of treatment largely depends on timely diagnosis and appropriate surgical management. Postoperative deep sternal wound infections in 4 cases were successfully treated with extensive debridement, pressurized jet irrigation with antibiotic solution, sternal refixation by Robicsek method, and dilute antibiotic irrigation via irrigation-suction system. We report 4 cases with review of articles.