• 제목/요약/키워드: High frequency partial discharge

검색결과 153건 처리시간 0.024초

GIS 감시진단용 다양한 센서를 적용한 PD 검출 및 패턴분석 결과 비교연구 (A Comparate Study for the PD Pattern Analysis using Different Type of Sensors Applicable to the On-line Monitoring of GIS)

  • 구자윤;장용무;최재옥;연만승;이지철
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권5호
    • /
    • pp.198-205
    • /
    • 2005
  • Many precedent investigations hate been made for the reliable assessment of the insulation state of large power apparatus for which partial discharge detection is one of tile plausible way. In this work, experimental investigations have been carried out to make the comparison on the PD(partial discharge) pattern analysis related to the five different types of artificial defects such as SFMP (Single Free Moving Particle), MFMP (Multi Free Moving Particle), Void, CFP (Conductor-Fixed Protrusion), EP (Enclosure Protrusion). For each PD pattern, PD detection has been done by tee different types of PD sensors such as HFCT(High Frequency Current Transformer), AE(Acoustic Emission) and UHF(Ultra High Frequency). And, in addition, frequency spectrum by the UHF sensor has been also made for each defect respectively. As a result, it is observed that the possibility of obtaining PD pattern based on PRPD(Phase Resolved Partial Discharge) in connection with the defects tinder investigation is dependant on the type of the sensor while the spectrum analysis is always successful to be achieved for every defect. Therefore, it could be suggested that the nature of PD source can be identified more distinctively when the conventional PRPDA is combined with spectrum analysis.

웨이브렛 변환을 이용한 부분방전 신호의 분석 (Analysis of Partial Discharge Signal Using Wavelet Transform)

  • 이현동;김충년;박광서;이광식;이동인
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권11호
    • /
    • pp.616-621
    • /
    • 2000
  • This paper deals with the multiresolution analysis of wavelet transform for partial discharge(PD). Test arrangement is based on the needle-plane electrode system and applied AC high voltage. The measured PD signal was decomposed into "approximations" and "details". The approximation are the high scale, low-frequency components of the PD signal. The details are the low-scale, high frequency components. The decomposition process are iterated to 3 level, with successive approximation being decomposed in turn, so that PD signal is broken down into many lower-resolution components. Through the procedure of signal wavelet transform, signal noise extraction and signal reconstruction, the signal is analyzed to determine the magnitude of PD.

  • PDF

기중방전 진전에 따른 방사전자파의 주파수 스펙트롬 특성 (The Characteristic of Frequency Spectrum of Electromagnetic Waves Radiated from Discharge in Air)

  • 박광서;윤대희;박창기;주재현;최병주;이광식;이동인
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.285-289
    • /
    • 1999
  • Insulation diagnosis techniques of power equipments for the stable power supply and prevention from accidents are of high importance. Diagnosis techniques is able to prevent from large accidents before they happen by finding signs of the accidents. From this point of view, this paper simulated discharge progress and partial discharge using needle-plan electrode system in air, studied the distribution of frequency spectrum of the radiated electromagnetic waves using biconical antenna and spectrum analyzer. From results of this study, the new method was introduced for measurement and analyzation of the radiated electromagnetic waves in accordance with discharge progress in air, Besides, according to the consideration of the mutual relation between frequency spectrum of the radiated electromagnetic waves and discharge progress, it was confirmed that detecting partial discharge and estimating discharge progress were possible.

  • PDF

154kV급 중간접속부내의 부분방전 진단을 위한 HFCT 적용 (HFCT for Diagnosing Partial Discharge in Middle Joint Box of 154kV Grade)

  • 이정수;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.214-217
    • /
    • 2008
  • To detect partial discharge of 154kV joint box, we have made experiment by using the HFCT sensor. Generally the signals which are detected in partial discharge test of underground power transmission cable are accompanied with both noises of high voltage and noises of surrounding Power cable. The most noise in near to end part of joint box is corona, beside other noises flowed from surrounding area. Partial discharge test is difficulty due to these noises. First, we test reliability on both injection of calibration signal in NJB and removal of low frequency. After that, we had analyzed frequencies by measuring signals in IJB with 300[m] distance from NJB. Also we had measured S/N ratio by using the indirected injection method of calibration signal in IJB. In this experiment, two measurement methods were difference of detection acquisition, but these had the equal frequency properties.

  • PDF

Mica/Epoxy 복합 절연계통의 부분방전 특성과 열화 관계에 관한 연구(I) (A Study on the Relationship between Aging and Partial Discharge Characteristics of the Mica/Epoxy Composite Insulation Systems (l))

  • 강동식;이우영;박정후;곽영순;김길용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.976-979
    • /
    • 1992
  • There are lots of problem which are delaminations and partial discharge of insulation materials in high-voltage rotating machines caused by mechanical, electrical and thermal aging. Several experiments have been aiming at finding the useful diagnostic parameters from the partial discharge characteristics by applying a new measurement techniques. This paper deals with the partial discharge characteristics (pulse height, pulse angle, pulse frequency spectrum and time interval), which may be a useful diagnostic concept in predicting insulation condition of mica/epoxy composite insulation materials, by using several measurement equipments (frequency spectrum analyzer. multichannel analyzer and time interval analyzer).

  • PDF

운전 중인 전력기기의 부분방전 측정장치 개발에 관하여 (Development of On-Line Patial Discharge Detector for Power)

  • 김광화;선종호;김우성;이종구;이준모;강창원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.733-739
    • /
    • 2000
  • This paper is described the development of on-line partial discharge detector for high voltage apparatus. This detector consists of acoustic and high frequency current sensors, amplifier part, A/D converter part, data communication part and computer. The contents of paper are characteristics of units and digital signal processing for reducing noise in partial discharge detection. We seek methods to do good digital signal processing for detection of partial discharge. We apply digital filtering methods to the elect Tic signal and a cross con-elation to the acoustic signal. This paper shows the characteristics of these filtering method and cross con-elation in partial discharge detection.

  • PDF

가스절연 개폐장치의 내부절연 성능검증을 위한 UHF 협대역 부분방전 진단법 (UHF Narrow Band Type Partial Discharge Diagnosis Method for the Internal Insulation Performance Verification of the Gas Insulated Switchgear)

  • 송원표;김정배;김민수;정재룡;박승재;고희석
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권9호
    • /
    • pp.414-420
    • /
    • 2005
  • A method for partial discharge diagnosis based on UHF narrow band type for GIS has been developed and calibrated. In generally, PD cannot be directly measured under on-line condition, but we can indirectly measure the electromagnetic wave made by PD using the high-frequency antenna. Compared with VHF band, electromagnetic waves of UHF band have a low influence for external noise in high-voltage substation. Therefore, we can detect the real abnormality with several pC in GIS using UHF narrow-band type method. For the case of no internal VHF sensor for GIS of the domestic substation, it has applied to use the external UHF sensor attached in spacer in GIS of existing substation. In this paper, we firstly described the technique of partial discharge measurement using frequency analysis and phase analysis in UHF band. Secondly, we presented the results of sensitivity test, the relationship of dBm-pC and diagnosis result of the cause of PD source by phase analysis. And then, we report the diagnosis result of partial discharge on the real GIS in domestic substation. These results make above method applicable for measurement of quantity and cause of PD for real operation GIS in high-voltage substation.

고주파 부분방전 측정에 의한 초고압 접속함 신뢰성 평가 기술 (A Evaluation Technique for Reliability of Extra-High Voltage Cable Accessories using High Frequency Partial Discharge Measurement)

  • 신두성;이창영;김충식;전승익;김동욱;박완기
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권3호
    • /
    • pp.186-195
    • /
    • 2000
  • In this paper, partial discharge (PD) measurement was performed to evaluate the quality of the cable joint and termination constructions. The resistive coupling technique for PD detection using resistivity of semiconducting layer of the cable in the accessories, such as joints and terminations. With high frequency PD (HEPD) measurement, an excellent sensitivity below 20pC could be achieved under unshielded condition. The localization of the defects in the accessories could be identified. During heating cycle, PDs were monitored and analyzed. At that time, the PDs were dependent on the temperature of the heating cycle and showed cyclic behaviors, which were attributed to local delamination of the interfaces, between epoxy unit and stress relief cone(SRC) and between SRC and cable, due to the difference of thermal expansion. As a conclusion, HFPD measurement technique was proven to be an effective diagnostic method for qualification of extra high voltage (EHV) cable accessories. With this technique, the optimal design of the components of the accessories could be verified not only in an early stage but also under operating condition. This technique would result in the improvement of the reliability of the EHV cable accessories.

  • PDF

에폭시/고무 계면에서의 결함에 따른 부분방전 특성 (Chracteristics of Partial Discharge Patterns Subjected to Different Defects at the Epoxy/Rubber Interface)

  • 김동욱;김정년;백주흠
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권5호
    • /
    • pp.199-204
    • /
    • 2002
  • In order to recognize the deterioration of insulation system by partial discharge (PD), the characteristics of PD patterns which are occurring at the interface between epoxy and rubber materials in extra high voltage cable joints, have been investigated. The artificial defects such as voids, metal particles, insulation fiber and water impregnated insulation fiber are planted between the interfaces. A high frequency partial discharge detection system was used for measuring PD signals. An analysis of the PD patterns is focused on the shape of PD pattern, phase, width and time-dependence for each artificial defect. The PD Patterns in each defect show the different behaviors and it is suggested that the precise discrimination of PD patterns could be used for the diagnosis of deterioration in the insulation systems.

인가 스트레스에 따른 HFPD의 통계적 패턴해석 (Statistic Pattern Analysis of HFPD According to Applied Stress)

  • 김덕근;이은석;정영일;임장섭;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마
    • /
    • pp.18-22
    • /
    • 2000
  • The partial discharge testing is widely used in insulation property measurement because it gives low stress to high voltage equipment which is undertaken tests. Therefore it is very useful method compare to previous destructive methods and effective diagnosis method in power transformer that requires live-line diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF