• 제목/요약/키워드: High frequency partial discharge

검색결과 153건 처리시간 0.026초

고압전동기 고정자 권선에서 부분방전 펄스의 전송 (Propagation of Partial Discharge Pulse in High Voltage Motor Stator Windings)

  • 김희동
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권11호
    • /
    • pp.512-515
    • /
    • 2003
  • This paper is to investigate how partial discharge pulse signal can flow in 6.6㎸ motor stator windings. Pulse propagation is experimentally analyzed in stator windings using a variety of frequency-domain techniques. The experiments were performed on two stator windings in the laboratory. Spectrum analyzer(9KHz to 3㎓) with tracking generator(100kHz to 3㎓) was used. Sweep time of the tracking generator was looms. The frequency spectrum of the response signal was detected by active FET probe(1㎓). The active FET probe has a flat amplitude response up to 1㎓ without high frequency attenuation. The stator winding acts as a low-pass filter below 600KHz, the high-frequency components being highly declined. The resonance peaks show about 1.1MHz and 2MHz in low frequency of No. 1 and No. 2 stator windings, respectively. This low-frequency range indicates that attenuation is low. The peaks of partial discharge magnitude show about 900MHz, 1.6MHz in No. 1 stator winding and about 800KHz, 1.4MHz in No. 2 stator winding.

절연유에서 부분방전에 의한 극초단파 신호 특성분석 (Signal Characteristics of Ultra-high Frequency Radiation from Partial Discharge in Insulation Oil)

  • 주형준;구선근;박기준;한기선;윤진열
    • 전기학회논문지P
    • /
    • 제57권1호
    • /
    • pp.56-59
    • /
    • 2008
  • We have designed 4 types(void in insulation paper, protrusion electrode, floating electrode, surface discharge) of partial discharge(PD) defect to simulate typical faults found in oil filled power transformers. Ultra-high frequency(UHF) radiation due to PD was measured using a UHF measuring system and a conventional PD measuring system, simultaneously. Electromagnetic radiation spectra of these defects show UHF radiation up to about 1.5-2 GHz range. The phase resolved partial discharge(PRPD) patterns of UHF radiation from the PD defects were also measured and the pattern reveals distinct feature for each defect types. The UHF measuring could be used to detect PDs in oil filled transformers and analysis of the PRPD pattern should provide useful information on origin of PD signal.

Comparison of High Frequency Detailed Generator Models for Partial Discharge Localization

  • Hassan Hosseini, S.M.;Hosseini Bafghi, S.M.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1752-1758
    • /
    • 2015
  • This paper presents partial discharge localization in stator winding of generators using multi-conductor transmission line (MTL) and RLC ladder network models. The high-voltage (HV) winding of a 6kV/250kW generator has been modeled by MATLAB software. The simulation results of the MTL and the RLC ladder network models have been evaluated with the measurements results in the frequency domain by applying of the Pearson’s correlation coefficients. Two PD generated calibrator signals in kHz and MHz frequency range were injected into different points of generator winding and the signals simulated/measured at the both ends of the winding. For partial discharge localization in stator winding of generators is necessary to calculate the frequency spectrum of the PD current signals and then estimate the poles of the system from the calculated frequency spectrum. Finally, the location of PD can be estimated. This theory applied for the above generator and the simulation/measured results show the good correlation for PD Location for RLC ladder network and MTL models in the frequency range of kHz (10kHz<f<1MHz) and MHz (1MHz<f<5MHz) respectively.

절연유 내 변압기 Turn간 결함에 의한 부분방전의 극초단파 전자기파 신호 특성 (Characteristics of Ultra High Frequency Partial Discharge Signals of Turn to Turn Defect in Transformer Oil)

  • 윤진열;주형준;구선근;박기준
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.2000-2004
    • /
    • 2009
  • In general, for the condition monitoring of a power transformer using the UHF PD measuring technique, detection of any partial discharge, identifying the defect in the transformer and locating the insulation defect are necessary. In this paper one of the most frequent detects which can result in turn to turn fault in power transformer was examined for identifying the defect. In order to model the defect, as a discharge source, a partial discharge cell was used for experimental activity. Magnitude of electromagnetic wave signals and corresponding amount of apparent discharge were measured simultaneously against phase of applied voltage to the discharge cell. Frequency range and phase resolved partial discharge signals were measured and analyzed. The results will be contributed to build the defect database of power transformer and to decrease the occurrence of transformer faults.

VHF안테나를 이용한 기중 부분방전 신호의 전자파 특성연구 (A Study on the Electromagnetic Pattern of Partial Discharge Signal using VHF(Very High Frequency) Antenna)

  • 이도훈;김재철;전영재;김영노;김광화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.560-562
    • /
    • 2002
  • This paper describes measurement and diagnosis methods for electromagnetic wave using a VHF(Very High Frequency) antenna. In the laboratory partial discharges are generated on a needle-plate and a plate-plate configuration. The detected electromagnetic wave is analyzed by FFT(Fast Fourier Transform). We propose a methode to classify creeping partial discharge and corona partial discharge that are detected in three frequency bands.

  • PDF

AE센서를 이용한 C-GIS의 부분방전 검출에 관한 연구 (A study on the PD detecting of C-GIS using AE sensor)

  • 이현동;이용희;신양섭;서정민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1659-1661
    • /
    • 2003
  • Recently, diagnostic techniques have been investigated to defect a partial discharge in high voltage electrical equipment. We have studied the characteristics of the acoustic partial discharge originating from the electrical defects in cubicle GIS(C-GIS). An acoustic emission(AE) sensor is used on the enclosure to detect partial discharge source because the sensor is sensitive to stress waves in its frequency range that may not be from a partial discharge source. AE signal is analyzed with phase-magnitude-frequency number(${\Phi}$-V-n) and pulse per second(PPS). Experience result has shown that the omitted acoustic signal has phase dependency and phase shift characteristic according to increase with applied voltage. These result will be helpful to the pattern recognition of the acoustic partial discharge in a C-GIS.

  • PDF

액체질소중 정극성 직류방전시 방사전자파의 주파수 스펙트럼 특성 (The Frequency Spectrum Characteristics of the Radiated Electromagnetic Waves during Positive DC Discharge in Liquid Nitrogen)

  • 박광서;신호영;최병주;최상태;김기채;이광식;이동인
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권9호
    • /
    • pp.648-655
    • /
    • 1999
  • In this study, a relationship between DC discharge and the radiated electromagnetic waves is investigated by measuring electromagnetic waves using a biconical antenna and a spectrum analyzer. The characteristics of frequency spectrum ofthe radiated electromagnetic waves was measured at the atmospheric pressure in Liquid Nitrogen $(LN_2)$ during partial discharges in nonuniform and uniform electric field depend on positive DC power. From this experiment results, it was confirmed that when partial discharge was produced in Liquid Nitrogen and Air, the signal of partial discharge was detected by this experiment and the analysis method. It is considered thatthese results obtained from this investigation may be used as fundamental data for diagnosis and prediction of insulation on the equipments ultra-high voltage, superconducting and cryogenic applications.

  • PDF

UWB 안테나를 이용한 MV급 전력케이블의 부분방전 측정 연구 (PD measuring on MV XLPE Calble by Using UWB Antenna)

  • 양상현;임광진;이용성;박노준;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.267-268
    • /
    • 2008
  • This paper presents compact low frequency ultra-wide band(UWB) sensor design and studying of the partial discharge diagnosis by sensing electromagnetic pulse emitted from the partial discharge source with new designed UWB sensor. In this study, we designed new type of compact low frequency UWB sensor based on microstrip antenna technology to detect both low frequency and high frequency band of partial discharge signal. And experiments of offline PD testing on in medium voltage (22.9kV) underground cable and mention the comparative results with the traditional HFCT as a reference sensor in the laboratory. In the series of comparative test, the calibration signal injection test provided with conventional IEC 60270 method and high voltage injection testing are included.

  • PDF

액체 질소중 교류방전 진전에 따른 방사전자파의 주파수 스펙트럼 특성 (The Characteristics of Frequency Spectrum of Radiated Electromagnetic Waves with AC Discharge Progress in Liquid Nitrogen)

  • 박광서;윤대희;이상훈;이현동;김충년;최병주;김기채;이광식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권3호
    • /
    • pp.123-129
    • /
    • 2003
  • In this paper, a relationship between AC discharge progress and the radiated electromagnetic waves was investigated by measuring electromagnetic waves using a biconical antenna and a spectrum analyzer. The frequency spectrum of the radiated electromagnetic waves were measured at the atmospheric pressure in liquid nitrogen($LN_2$) during partial discharges progressed by AC high voltage in nonuniform electric field. Front the results of this study, a new method was introduced for measurement and analysis of the radiated electromagnetic waves with discharge progress in $LN_2$ Besides. according to the consideration of the mutual relation between frequency spectrum of the radiated electromagnetic waves and discharge progress, it was confirmed that detecting partial discharge and estimating discharge progress could be possible. It is considered that these results obtained from this investigation may be used as fundamental data for diagnosis and prediction of electric insulations about superconducting and cryogenic power equipments.

방사전자파를 이용한 고분자애자의 오손량 분류기법 (Classification Technique of Kaolin Contaminants Degree for Polymer Insulator using Electromagnetic Wave)

  • 박재준
    • 한국전기전자재료학회논문지
    • /
    • 제19권2호
    • /
    • pp.162-168
    • /
    • 2006
  • Recently, diagnosis techniques have been investigated to detect a Partial Discharge associated with a dielectric material defect in a high voltage electrical apparatus, However, the properties of detection technique of Partial Discharge aren't completely understood because the physical process of Partial Discharge. Therefore, this paper analyzes the process on surface discharge of polymer insulator using wavelet transform. Wavelet transform provides a direct quantitative measure of spectral content in the time~frequency domain. As it is important to develop a non-contact method for detecting the kaolin contamination degree, this research analyzes the electromagnetic waves emitted from Partial Discharge using wavelet transform. This result experimentally shows the process of Partial Discharge as a two-dimensional distribution in the time-frequency domain. Feature extraction parameter namely, maximum and average of wavelet coefficients values, wavelet coefficients value at the point of $95\%$ in a histogram and number of maximum wavelet coefficient have used electromagnetic wave signals as input signals in the preprocessing process of neural networks in order to identify kaolin contamination rates. As result, root sum square error was produced by the test with a learning of neural networks obtained 0.00828.