• Title/Summary/Keyword: High frequency motor

Search Result 554, Processing Time 0.033 seconds

Survey on Satisfaction Survey for Korean Medicine Treatment in Traffic Injury Patients (교통사고 후 한의치료에 대한 만족도 조사 연구)

  • Kim, Juchul;Oh, Soosuk;Kim, Dongsu
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.25 no.3
    • /
    • pp.15-24
    • /
    • 2021
  • Objectives : This study sought to identify the Korean medicine treatment satisfaction of 3,000 patients who are 19 or older with experiences of being treated with Korean medicine at Korean medicine clinics or Korean medicine hospitals after experiencing traffic accidents. Methods : Frequency analysis was carried out to identify the effectiveness and satisfaction of Korean medicine services, and independent sample t-test was carried out to compare the satisfaction of users with different characteristics. Lastly, cross analysis(chi-square) was carried out to examine the relation between satisfaction and willingness to recommend. Results : Firstly, 91.3% of the patients were satisfied with the medical services provided at Korean medicine clinics, with the most satisfactory Korean medicine treatments in the order of acupuncture, moxibustion, cupping, Korean physical therapy, herbal acupuncture, Chuna manual therapy, herbal medicine, and others. Secondly, 71.3% of the patients answered that outpatient treatment was appropriate while 65.3% of the patients answered that hospitalized treatment was appropriate regarding duration of treatment at Korean medicine clinics, mostly being satisfied with the treatment duration at Korean medicine clinics and Korean medicine hospitals. Thirdly, in a survey on effectiveness of Korean medicine treatment compared to occidental medicine treatment, 85.9% of the patients answered: "the effectiveness of Korean medicine treatment is higher compared to occidental medicine or similar". Conclusion : From the results of this study, it was identified that satisfaction of Korean medicine treatment is high in motor insurance, and that higher satisfaction led to higher willingness to recommend Korean medicine treatment to others. Based on such results, the expansion of the role of Korean medicine could be understood.

Building Bearing Fault Detection Dataset For Smart Manufacturing (스마트 제조를 위한 베어링 결함 예지 정비 데이터셋 구축)

  • Kim, Yun-Su;Bae, Seo-Han;Seok, Jong-Won
    • Journal of IKEEE
    • /
    • v.26 no.3
    • /
    • pp.488-493
    • /
    • 2022
  • In manufacturing sites, bearing fault in eletrically driven motors cause the entire system to shut down. Stopping the operation of this environment causes huge losses in time and money. The reason of this bearing defects can be various factors such as wear due to continuous contact of rotating elements, excessive load addition, and operating environment. In this paper, a motor driving environment is created which is similar to the domestic manufacturing sites. In addition, based on the established environment, we propose a dataset for bearing fault detection by collecting changes in vibration characteristics that vary depending on normal and defective conditions. The sensor used to collect the vibration characteristics is Microphone G.R.A.S. 40PH-10. We used various machine learning models to build a prototype bearing fault detection system trained on the proposed dataset. As the result, based on the deep neural network model, it shows high accuracy performance of 92.3% in the time domain and 98.3% in the frequency domain.

High Efficient Inductive Power Supply System Implemented for On Line Electric Vehicles

  • Huh, Jin;Park, Eun-Ha;Jung, Gu-Ho;Rim, Chun-Taek
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.105-110
    • /
    • 2009
  • The On Line Electric Vehicles(OLEV) that can pick up inductive power from underground coils on driving with high efficiency have been developed this year, and is now proposed in this paper. The IPS(Inductive Power Supply) system consists of power supply inverters, power supply rails, pick up modules, and a regulator. There are 3 generations of IPS have been developed so far, and the $4^{th}$ generation IPS is being developed. The $1^{st}$ generation has been demonstrated this Feb. 27, which is equipped with mechanically auto tracking pick-up module with 1cm air gap, and showed 80% power efficiency. The $2^{nd}$ generation IPS applied to an 120kW (average)/240kW(peak) motor powered electric bus has 17cm air gap with 72% power efficiency. For the $2^{nd}$ generation IPS, the Power supply inverter has 440V, 3phase input and 200A @ 20kHz output. The test power supply rail of 240m long is segmented by 60m each, where newly developed core structure and power cable are constructed under the road covered with asphalt of 5cm thickness. The pick-up modules which consist of core, winding wire, and rectifiers are fixed to the bottom of the bus which can carry more than 40 passengers and can pick up max. 60kW. To remove parasitic component and to transfer maximum power between them resonant circuit topology is applied to the primary and secondary sides. The EMF level is below 62.5mG at 1.75m from the center of the road to meet the regulation. Several effective ways of reducing EMF levels have been developed. In addition, effective ways to solve problems related high frequency power cables buried in ground and it's proof from soil have been studied also. This development shows that the IPS system is capable of supplying enough power to the pick-up of OLEV and can reduce battery size, weight and cost, which means the IPS with OLEV is one of the best candidate for EV.

  • PDF

Development of Rotordynamics Program Based on the 2D Finite Element Method for Flywheel Energy Storage System (2차원 유한요소법을 적용한 플라이휠 에너지 저장 장치 동특성 해석 프로그램 개발)

  • Gu, Dong-Sik;Bae, Yong-Cae;Lee, Wook-Ryun;Kim, Jae-Gu;Kim, Hyo-Jung;Choi, Byeong-Keun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.11
    • /
    • pp.1757-1763
    • /
    • 2010
  • Flywheel energy storage system (FESS) is defined as a high speed rotating flywheel system that can save surplus electric power. The FESS is proposed as an efficient energy storage system because it can accumulate a large amount of energy when it is operated at a high rotating speed and no mechanical problems are encountered. The FESS consists of a shaft, flywheel, motor/generator, bearings, and case. It is difficult to simulate rotor dynamics using common structure simulation programs because these programs are based on the 3D model and complex input rotating conditions. Therefore, in this paper, a program for the FESS based on the 2D FEM was developed. The 2D FEM can model easier than 3D, and it can present the multi-layer rotor with different material each other. Stiffness changing of the shaft caused by shrink fitting of the hub can be inputted to get clear solving results. The results obtained using the program were compared with those obtained using the common programs to determine any errors.

Recent research activities on hybrid rocket in Japan

  • Harunori, Nagata
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.1-2
    • /
    • 2011
  • Hybrid rockets have lately attracted attention as a strong candidate of small, low cost, safe and reliable launch vehicles. A significant topic is that the first commercially sponsored space ship, SpaceShipOne vehicle chose a hybrid rocket. The main factors for the choice were safety of operation, system cost, quick turnaround, and thrust termination. In Japan, five universities including Hokkaido University and three private companies organized "Hybrid Rocket Research Group" from 1998 to 2002. Their main purpose was to downsize the cost and scale of rocket experiments. In 2002, UNISEC (University Space Engineering Consortium) and HASTIC (Hokkaido Aerospace Science and Technology Incubation Center) took over the educational and R&D rocket activities respectively and the research group dissolved. In 2008, JAXA/ISAS and eleven universities formed "Hybrid Rocket Research Working Group" as a subcommittee of the Steering Committee for Space Engineering in ISAS. Their goal is to demonstrate technical feasibility of lowcost and high frequency launches of nano/micro satellites into sun-synchronous orbits. Hybrid rockets use a combination of solid and liquid propellants. Usually the fuel is in a solid phase. A serious problem of hybrid rockets is the low regression rate of the solid fuel. In single port hybrids the low regression rate below 1 mm/s causes large L/D exceeding a hundred and small fuel loading ratio falling below 0.3. Multi-port hybrids are a typical solution to solve this problem. However, this solution is not the mainstream in Japan. Another approach is to use high regression rate fuels. For example, a fuel regression rate of 4 mm/s decreases L/D to around 10 and increases the loading ratio to around 0.75. Liquefying fuels such as paraffins are strong candidates for high regression fuels and subject of active research in Japan too. Nakagawa et al. in Tokai University employed EVA (Ethylene Vinyl Acetate) to modify viscosity of paraffin based fuels and investigated the effect of viscosity on regression rates. Wada et al. in Akita University employed LTP (Low melting ThermoPlastic) as another candidate of liquefying fuels and demonstrated high regression rates comparable to paraffin fuels. Hori et al. in JAXA/ISAS employed glycidylazide-poly(ethylene glycol) (GAP-PEG) copolymers as high regression rate fuels and modified the combustion characteristics by changing the PEG mixing ratio. Regression rate improvement by changing internal ballistics is another stream of research. The author proposed a new fuel configuration named "CAMUI" in 1998. CAMUI comes from an abbreviation of "cascaded multistage impinging-jet" meaning the distinctive flow field. A CAMUI type fuel grain consists of several cylindrical fuel blocks with two ports in axial direction. The port alignment shifts 90 degrees with each other to make jets out of ports impinge on the upstream end face of the downstream fuel block, resulting in intense heat transfer to the fuel. Yuasa et al. in Tokyo Metropolitan University employed swirling injection method and improved regression rates more than three times higher. However, regression rate distribution along the axis is not uniform due to the decay of the swirl strength. Aso et al. in Kyushu University employed multi-swirl injection to solve this problem. Combinations of swirling injection and paraffin based fuel have been tried and some results show very high regression rates exceeding ten times of conventional one. High fuel regression rates by new fuel, new internal ballistics, or combination of them require faster fuel-oxidizer mixing to maintain combustion efficiency. Nakagawa et al. succeeded to improve combustion efficiency of a paraffin-based fuel from 77% to 96% by a baffle plate. Another effective approach some researchers are trying is to use an aft-chamber to increase residence time. Better understanding of the new flow fields is necessary to reveal basic mechanisms of regression enhancement. Yuasa et al. visualized the combustion field in a swirling injection type motor. Nakagawa et al. observed boundary layer combustion of wax-based fuels. To understand detailed flow structures in swirling flow type hybrids, Sawada et al. (Tohoku Univ.), Teramoto et al. (Univ. of Tokyo), Shimada et al. (ISAS), and Tsuboi et al. (Kyushu Inst. Tech.) are trying to simulate the flow field numerically. Main challenges are turbulent reaction, stiffness due to low Mach number flow, fuel regression model, and other non-steady phenomena. Oshima et al. in Hokkaido University simulated CAMUI type flow fields and discussed correspondence relation between regression distribution of a burning surface and the vortex structure over the surface.

  • PDF

An analysis on Flicker Phenomenon of a Fluorescent lights for the commercial operating EMU (영업운행 전동차 객실형광등의 플리커(Flicker) 현상에 관한 분석 연구)

  • Ha, Jong-Eun;Han, Seon-Ho;Park, Jae-Hong;Lee, Dae-Won
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1240-1246
    • /
    • 2006
  • Generally, there are two types of main factors to affect output power quality of a auxiliary power supply an EMU(electric multiple unit). One is a voltage flicker by amplitude modulation of short time and air compressors. The other is repetitive motion of large capacity motor such as air compressors, HVAC unit etc. in main factors. This paper compared two kinds of fluorescent lamp, 32W (after remodeling interior) and 40W(before remodeling interior) and measured the light output varying input power(AC220V) for a flicker phenomenon related power supply of lamps in EMU. Also, we analyzed a flicker considering EMU operating time and density in order to grasp main factors of a load change to cause a voltage change. As a results of test, a 40W fluorescent lamp was more insensitive with 20.26% degree an eye recognition degree sides about changes of the input power and lower with 19.9% voltage side generating flicker compare with fluorescent lamp 32W. Also, we confirmed the fact which the fluorescent lamp flicker was generated by varying fluorescent lamp output voltage when the commercial EMU was in high driving density and at the busy time. Additionally, we confirmed the frequency band which an EMU passenger could feel sensitively blinking of a fluorescent lamp was visually $8Hz{\sim}15Hz$.

  • PDF

Survey About Current Status of Pediatric and Adolescent Physical Therapy: Focus on Pediatric and Adolescent Rehabilitation Hospitals in Seoul and Gyeonggi Province (소아 청소년 물리치료 실태 조사: 서울 경기 지역 소아 청소년 재활병원을 중심으로)

  • Kim, Jeong-soo;Min, Kyoung-chul
    • Therapeutic Science for Rehabilitation
    • /
    • v.12 no.4
    • /
    • pp.67-80
    • /
    • 2023
  • Objective : This study aimed to investigate the current status of physical therapy in children and adolescents. Methods : Sixty questionnaires from physical therapists treating children and adolescents with disabilities were analyzed. The questionnaire consisted of questions on physical therapy, participants, satisfaction, and the assessment of pediatric and adolescent physical therapy. Descriptive statistics and frequencies were used to investigate the current status, participants, and satisfaction. Differences between physical therapy participation difficulty, importance-ability of major aspects of pediatric and adolescent physical therapy, and therapy goal frequency were analyzed using paired T-test. Results : 11 to 15 cases (66.7%) and one-on-one treatment (95.0%) were performed independently (95.0%). The main ages of the subjects were preschool and school, the diagnoses were brain lesions and developmental delay, and treatment was conducted for up to 20 years or older. Satisfaction with pediatric and adolescent physical therapy was high (70.0%), as was the intensity of work (71.7%). Neurodevelopmental therapy, gait training, and goal-directed rehabilitation were the main treatments, and Gross Motor Function Measures of 88 and 66, respectively, were used. Respondents said that current fee system is inadequate (66.1%) and appropriate fee system is needed. Conclusion : This study extensively investigated the content of and factors related to pediatric and adolescent physical therapy. Based on the current situation, efforts to improve the expertise and continuity of pediatric and adolescent physical therapists and apply the latest treatment techniques are required.

Reliability of Muscle Evaluation with a Tactile Sensor System (촉각센서를 이용한 근육평가의 신뢰도 조사)

  • Oh, Young-Rak;Lee, Dong-Ju;Kim, Sung-Hwan;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.3
    • /
    • pp.337-344
    • /
    • 2005
  • A tactile sensor employs a piezoelectric element to detect contact frequency shifts and thereby measure the stiffness or softness of material such as tissue, which allows the sensor to be used in many fields of research for urology, cardiology, gynecology, sports medicine and caner detection and especially for cosmetics and skin care. In this study, reliability of the tactile sensor system was investigated with its manual application to the muscles susceptible to temporomandibular disorders. Stiffness and elasticity of anterior temporalis, masseter and trapezius muscles were calibrated bilaterally from 5 healthy men with an average of 24.5$\pm$0.94 years. The tactile sensor used in this study had a computer-controlled and motor-driven sensor unit which automatically pressed down on the skin surface over the muscles being measured and retracted, thereby providing the hysteresis curve. The slope of the tangent of the hysteresis curve (${\Delta}f/{\Delta}x$) is defined as stiffness of the muscle being measured and the distance between the two parts of the curve as its elasticity. To determine inter-examiner reliability, all the measurements were performed by the two examiners A and B, respectively and the same examination were repeated with an interval of 2 days for intra-examiner reliability. The results from this study demonstrated high reliability in measuring stiffness and elasticity of anterior temporalis, masseter and upper trapezius muscles using a tactile sensor system. It is suggested that the tactile sensor system can be a highly reproducible and effective instrument for quantitative evaluation of the muscle in head and neck region.

Research on the Relation between Musculoskeletal symptoms and Diagnosis using Moire Topography among Workers at an Automobile Manufacturing Plant (자동차회사 근로자를 대상으로 한 근골격계 자각증상과 moire 영상 진단과의 관계 연구)

  • Chun Eun-Joo;Lee Young-Gil;Jahng Doo-Sub;Lee Ki-Nam;Song Yung-Sun
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.5 no.2
    • /
    • pp.69-92
    • /
    • 2001
  • The purposes of this study were to offer foundation making more certain standards of musculoskeletal disorder diagnosis, We researched musculoskeletal symptoms degrees, frequencies, and cares and then examined relation between musculoskeletal symptoms and diagnosis of musculoskeletal conditions using moire topography among workers at an automobile manufacturing plant. Therefore we propose the possibility of moire topography as diagnosing utilities of musculoskeletal disorders. Methods: This study was to examine the general characteristics, complaints of musculoskeletal symptoms, and work-related musculoskeletal disorder rates of cervicobrachial and lumbar area by survey among 435 workers at an automobile manufacturing plant and then to show each frequency and percentage, In the diagnosis using moire topography, we studied pain control necessity of cervicobrachial and lumbar area, 435 subjects were classified by 5 levels: A(no symptoms), B(need management), C(need treatment) and then more divided by B1(light symptoms)/B2(heavy symptoms), C1(light symptoms)/C2(heavy symptoms), And musculoskeletal areas were divided by 2 parts, cervicobrachial area(neck, shoulder, arm&elbow, and wrist&hand) and lumbar area, Then, frequency and percentage of each musculoskeletal areas(cervicobrachial and lumbar area) were appeared. At last, Pearson's chi-square test analysis was utilized to observe the relation between diagnosis using moire topography and general characteristics and the relation between diagnosis using moire topography and work-related complaint of musculoskeletal symptoms of cervicobrachial and lumbar area, Results: The subjects employed for this research were categorized into; by gender, all of them were males(l00%): by age, under 35 years 12 %, 36-40 years 56.3%, 41-45 years 26.3 %, and above 46 years 5.3% with 36-40 years accounting for most of it. By living location, owned houses represented 69.7%, rented houses 23.4%, monthly-rented 1.6%, the others 5.3%; by education, middle school and lower represented 3.0%, high school 89.4%, and junior college and higher 7.6% with high school occupying most of the group. By marital status, married represented 95.2%, unmarried 4.1%, and the others 0.7% with most of them married; by alcohol, drinking represented 81.8% and non-drinking 18.2%; by smoking status, smoking represented 53.6%, non-smoking 46.4% with no big difference between them. By working time(hours/week), below 50 represented 26.9%, 50-60 67.6%, above 60 5.5%; by working time(hours/day), below 9 represented 21.6%, 10-12 73.1%, above 13 5.3%; by job tenure(years), below 10 represented 25.1%, 11-15 54.3%, 16-20 15.2%, above 21 5.5%. By personal income per year, below 30 million won represented 11.0%, 30-40 84.8%, above 40 4.1%; by sleeping hours, below 6 hours represented 26.7%, 7-8 hours 69.9%, above 9 hours 3.4%. Complaint rates of musculoskeletal symptoms and work-related musculoskeletal disorder rates were 63.9% and 54.9% with shoulder area occupying most of both them. By pain degree of musculoskeletal symptoms, shoulder area represented $2.73{\pm}0.84$, lumbar area $2.66{\pm}0.86$, wrist and hand area $2.59{\pm}0.86$, neck area $2.55{\pm}0.74$, and arm and elbow area $2.48{\pm}0.71$. By cares about musculoskeletal symptoms, taking medication or care represented 34.4%-46.7%, absence or leave 15.4%-28.7%, and job transfer 6.3%-11.5%. So experienced cases more than one thing among cares about musculoskeletal symptoms represented 39.6%-54%. In the diagnosis using moire topography, pain control necessity of cervicobrachial area was shown below; A(no symptoms) 20.7%, B1(need management/light symptoms) 64.6%, B2(need management/heavy symptoms) 11.5%, C1(need treatment/light symptoms) 3.0%, C2(need treatment/heavy symptoms) 0.2%. By lumbar area, A(no symptoms) 8.7%, B1(need management/light symptoms) 52.2%, B2(need management/heavy symptoms) 30.3%, C1(need treatment/light symptoms) 8.7%, C2(need treatment/heavy symptoms) was none. In the relation between pain control necessity and general characteristics, age(P=0.013), education(P=0.000), and job tenure(P=0.012) with pain control necessity showed differences with significance. The relation between pain control necessity and complaint of musculoskeletal symptoms of cervicobrachial and lumbar area showed no difference with significance; in cervicobrachial area represented P=0.708, lumbar area P=0.318 Conclusions: This study for musculoskeletal symptoms on workers at automobile manufacturing plant showed that complaint rates of musculoskeletal symptoms for cervicobrachial and lumbar area were so high, 63.9%. But Pearson's chi-square test analysis was utilized to study the relation between musculoskeletal symptoms and the diagnosis using moire topography, showed no differences with significance. They have no differences with significance, but the prevalence rates of diagnosis using moire topography for cervicobrachial and lumbar area were more higher than complaint rates of musculoskeletal symptoms; complaint rates of musculoskeletal symptoms were 52.4%, 34.5% and the diagnosis using moire topography were 79.3%, 91.3% for cervicobrachial and lumbar area. The results of this study indicate that the diagnosis using moire topography can find weak musculoskeletal disorders that an individual can not feel, not be judged work-related musculoskeletal disease. Therefore, this study has an important meaning that diagnosis using moire topography can predict and control own physical condition complete musculoskeletal disorders beforehand, since oriental medicine theory considers that prevention is important.

  • PDF

Integrated Rotary Genetic Analysis Microsystem for Influenza A Virus Detection

  • Jung, Jae Hwan;Park, Byung Hyun;Choi, Seok Jin;Seo, Tae Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.88-89
    • /
    • 2013
  • A variety of influenza A viruses from animal hosts are continuously prevalent throughout the world which cause human epidemics resulting millions of human infections and enormous industrial and economic damages. Thus, early diagnosis of such pathogen is of paramount importance for biomedical examination and public healthcare screening. To approach this issue, here we propose a fully integrated Rotary genetic analysis system, called Rotary Genetic Analyzer, for on-site detection of influenza A viruses with high speed. The Rotary Genetic Analyzer is made up of four parts including a disposable microchip, a servo motor for precise and high rate spinning of the chip, thermal blocks for temperature control, and a miniaturized optical fluorescence detector as shown Fig. 1. A thermal block made from duralumin is integrated with a film heater at the bottom and a resistance temperature detector (RTD) in the middle. For the efficient performance of RT-PCR, three thermal blocks are placed on the Rotary stage and the temperature of each block is corresponded to the thermal cycling, namely $95^{\circ}C$ (denature), $58^{\circ}C$ (annealing), and $72^{\circ}C$ (extension). Rotary RT-PCR was performed to amplify the target gene which was monitored by an optical fluorescent detector above the extension block. A disposable microdevice (10 cm diameter) consists of a solid-phase extraction based sample pretreatment unit, bead chamber, and 4 ${\mu}L$ of the PCR chamber as shown Fig. 2. The microchip is fabricated using a patterned polycarbonate (PC) sheet with 1 mm thickness and a PC film with 130 ${\mu}m$ thickness, which layers are thermally bonded at $138^{\circ}C$ using acetone vapour. Silicatreated microglass beads with 150~212 ${\mu}L$ diameter are introduced into the sample pretreatment chambers and held in place by weir structure for construction of solid-phase extraction system. Fig. 3 shows strobed images of sequential loading of three samples. Three samples were loaded into the reservoir simultaneously (Fig. 3A), then the influenza A H3N2 viral RNA sample was loaded at 5000 RPM for 10 sec (Fig. 3B). Washing buffer was followed at 5000 RPM for 5 min (Fig. 3C), and angular frequency was decreased to 100 RPM for siphon priming of PCR cocktail to the channel as shown in Figure 3D. Finally the PCR cocktail was loaded to the bead chamber at 2000 RPM for 10 sec, and then RPM was increased up to 5000 RPM for 1 min to obtain the as much as PCR cocktail containing the RNA template (Fig. 3E). In this system, the wastes from RNA samples and washing buffer were transported to the waste chamber, which is fully filled to the chamber with precise optimization. Then, the PCR cocktail was able to transport to the PCR chamber. Fig. 3F shows the final image of the sample pretreatment. PCR cocktail containing RNA template is successfully isolated from waste. To detect the influenza A H3N2 virus, the purified RNA with PCR cocktail in the PCR chamber was amplified by using performed the RNA capture on the proposed microdevice. The fluorescence images were described in Figure 4A at the 0, 40 cycles. The fluorescence signal (40 cycle) was drastically increased confirming the influenza A H3N2 virus. The real-time profiles were successfully obtained using the optical fluorescence detector as shown in Figure 4B. The Rotary PCR and off-chip PCR were compared with same amount of influenza A H3N2 virus. The Ct value of Rotary PCR was smaller than the off-chip PCR without contamination. The whole process of the sample pretreatment and RT-PCR could be accomplished in 30 min on the fully integrated Rotary Genetic Analyzer system. We have demonstrated a fully integrated and portable Rotary Genetic Analyzer for detection of the gene expression of influenza A virus, which has 'Sample-in-answer-out' capability including sample pretreatment, rotary amplification, and optical detection. Target gene amplification was real-time monitored using the integrated Rotary Genetic Analyzer system.

  • PDF