• Title/Summary/Keyword: High frequency cavity

Search Result 172, Processing Time 0.029 seconds

Development of FBG sensor System for Measuring the High Frequent Vibration of Structures and the Natural Frequency of Composites (고주파 진동 측정을 위한 FBG 센서 시스템 개발 및 복합재 시편의 고유진동수 측정)

  • Kim, Dae-Hyun;Koo, Bon-Yong;Kim, Chun-Gon;Hong, Chang-Sun;Lee, In
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.05a
    • /
    • pp.159-162
    • /
    • 2002
  • We introduce a simple optically passive detection scheme for Bragg grating sensors. This detection scheme is based on two cavity lengths in Fabry-Perot read-out interferometers to produce two quadrature phase shifted signals from the Bragg grating sensor. The passive detection technique is demonstrated by the use of Bragg grating sensors in measuring the dynamic vibrations of the composites.

  • PDF

Nonlinear Impedance Characteristics of Helmholtz Resonator with Tapered Neck (경사진 목을 가지는 헬름홀쯔 공명기의 비선형 임피던스 특성)

  • Seo, Sang-Hyeon;Chung, Hoe-min;Kim, Yang-hann
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.75-80
    • /
    • 2012
  • Helmholtz resonator is widely used acoustic instrument which has high absorption characteristics at its resonance frequency. Particularly it maintains good performance even in the low frequency region that is difficult to control by general porous absorptive materials. However, under severely high sound pressure level, the absorption characteristics are changed by increase of resistance due to nonlinear behavior of neck impedance. Because of this nonlinear behavior, it is difficult to obtain the expected absorption performance under high sound pressure environment. Thus, in order to prevent excessive rise of resistance, the resonator with neck having cross section dimension decrease away from the entry of the resonator cavity could be suggested. This paper introduces the experiment method and results about nonlinear characteristics of Helmholtz resonator with tapered neck and proposes the approximate nonlinear impedance model.

  • PDF

Design of Acoustic Resonator Array for Low Frequency Mode Control of Launch Vehicle (위성 발사체 탑재부 저주파 음향 모드 제어를 위한 공명기 배치 설계)

  • Seo, Sang-Hyun;Park, Soon-Hong;Jang, Young-Soon;Yi, Yeong-Moo;Cho, Gwang-Rae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.521-524
    • /
    • 2005
  • To protect a satellite and electronic equipment from the acoustic loads generated by rocket propulsion system, many launch vehicle use acoustic blanket. Most high frequency region of the acoustic loads is reduced by nose fairing skins and acoustic barrier, but low frequency region is not. In order to control low frequency acoustic mode, we designed away resonator panel which was made of composite materials. This paper shows the absorption coefficient measurement result of resonator and SPL(Sound Pressure Level) reduction by using resonators in a rectangular cavity for experiment. Proper arrangement of acoustic resonators at each mode reduce effectively SPL around the satellite through changing boundary condition.

  • PDF

Exhaust Noise Control of Marine Diesel Engine Using Hybrid Silencer (조합형 소음기를 이용한 박용 디젤 엔진 배기 소음 제어)

  • Lee, Tae-Kyoung;Joo, Won-Ho;Bae, Jong-Gug
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.7
    • /
    • pp.679-684
    • /
    • 2009
  • Low frequency exhaust noise of marine diesel engine is one of the most important noise sources in vessels. However, conventional absorptive silencers are ineffective to control exhaust noise because of low absorption in the low frequency range. In the paper, exhaust noise control of marine diesel engine was studied by using the hybrid silencer, which was composed of virtually divided array of concentric hole-cavity resonators and conventional absorptive silencer. A series of tests including field tests were performed to investigate the acoustic performance of the hybrid silencer. Consequently, its high performance of 5${\sim}$10 dB noise reduction in the low frequency range was confirmed and it is expected to be very helpful in reducing the exhaust noise of marine diesel engine.

Exhaust Noise Control of Marine Diesel Engine by using Resonator Type Silencer (공명형 소음기를 이용한 박용 디젤엔진 배기 소음 제어)

  • Lee, Tae-Kyung;Joo, Won-Ho;Bae, Jong-Gug
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.350-354
    • /
    • 2008
  • Low frequency exhaust noise of marine diesel engine is one of the most important noise sources in vessels. However, conventional absorptive silencers are limited because the absorptive material is not effective in low frequency range. In the paper, exhaust noise control of marine diesel engine has been studied by using the resonator type silencer, which was composed of concentric hole-cavity resonators. The acoustic performance of the resonator type silencer was verified by the insertion loss measurement considering flow effect. Consequently, its high performance, about $5{\sim}8dB$ noise reduction, in the low frequency range was confirmed by insertion loss measurements conducted in the ship.

  • PDF

A Study on the Method to Suppress Radiation-Noise with Electromagnetic Wave Absorber in the Rectangular Cavity Resonator (전파 흡수체에 의한 구형 공동 공진기의 방사노이즈 억제 방법에 관한 연구)

  • 김경용;김왕섭
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.28A no.12
    • /
    • pp.19-23
    • /
    • 1991
  • A method for suppressing unwanted resonance modes by attaching an electromagnetic wave absorber onto a metal case was studied to prevent performance deterioration of electronic devices. The electromagnetic wave absorber fabricated for this study had an attenuation characteristics above 20dB in the frequency band from 450MHz, 1150MHz. A rectangular cavity resonator whose resonance frequencies of TE$_{101}$, TE$_{102}$ modes were 900MHz, 1250MHz, respectively, was made to measure attenuation for the electromagnetic wave absorber-metal assembly. The result showed that the resonance mode for high attenuation was sensitive to the location of electromagnetic wave absorber, and the attenuation characteristics above 20dB could be obtained when electromagnetic wave absorber was properly positioned.

  • PDF

Experimental Study and Numerical Simulation of Cavity Oscillation in a Conical Diffuser

  • Chen, Chang-Kun;Nicolet, Christophe;Yonezawa, Koichi;Farhat, Mohamed;Avellan, Francois;Miyazawa, Kazuyoshi;Tsujimoto, Yoshinobu
    • International Journal of Fluid Machinery and Systems
    • /
    • v.3 no.1
    • /
    • pp.91-101
    • /
    • 2010
  • Based on the one-dimensional stability analysis, the self-excited oscillation in hydraulic power generating systems was studied by a simple experiment and numerical simulation. It was shown that a cavity in a conical diffuser can cause surge. With the diffuser, a high amplitude and low frequency oscillation occurs at low cavitation number. This oscillation was not observed with the straight pipe. It was confirmed that the diffuser effect of the draft tube can be the cause of the full load surge in hydraulic power system. Numerical results were also analyzed to check the validity of the one-dimensional stability analysis.

The sound insulation performance of eco-friendly loess brick wall (친환경 황토벽체의 차음성능 평가에 관한 연구)

  • Lee, Tai-Gang;Kim, Yul;Song, Kook-Gon;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.9 no.6
    • /
    • pp.13-18
    • /
    • 2009
  • Korean traditional houses have been developed in harmony with natural environment and comfortable indoor condition by using the natural resources including building layout, space composition and materials. Originally Korea traditional architectures have used wood lintel constructions and loess walls through the many years. Theses loess have many strength such as highly heat capacity, controling of humidity, a deodorant than any other materials. Nowaday it is recommended to use exterior and interior walls in loess wall to meet the eco-friendly materials to improve our residental environmental. Thus this study aims to research the sound insulation performance of traditional loess brick wall varied with thickness, thermal insulation materials and cavity wall. The sound insulation performance of these loess walls are compared with other masonry wall's and sound insulation performance of th walls were tested in anechoic laboratory to measure the sound transmission loss of these walls. The loess brick wall with 75mm thickness of cavity is shown the sound insulation performance with Rw 57 which is nearly same performances of 1B brick wall and cement 8' block wall, The improving effect of insulation materials is shown in the high frequency bandwidth. Especially, there is improving as much as 11 dB using the extruded poly stylene form(75mm) and poly ethylene film(0.7mm).

The Effect of Joint Space Pumping Treatment in Patients with Reducible Disc Displacement Accompanied by TMJ Sound and Pain (악관절잡음 및 동통을 동반한 정복성 관절원판 변위환자에 대한 관절강 Pumping 효과)

  • Kim, Hyeon-Cheol;Choi, Jong-Hoon;Park, Hye-Suk;Kim, Chong-Youl
    • Journal of Oral Medicine and Pain
    • /
    • v.24 no.1
    • /
    • pp.9-24
    • /
    • 1999
  • Pumping into the upper joint cavity of the TMJ was done on patients who had reducible disc displacement with pain. This article discusses the change in TMJ sounds before and after the Pumping treatment. 20subjects(mean age of $32.1{\pm}10.2yr$)were selected among those who visited the department of Oral Medicine of Yonsei University for the treatment of craniomandibular dysfunctions. Through a thorough history taking, clinical exam and X-ray taking these subjects were diagnosed as reducible disc displacement patients, and they were subdivided into two groups as acute and chronic according to the time the TMJ sound was made. Sonopak was used to measure the TMJ sound before, right after and one-week after the Pumping treatment. VAS was used to measure the degree of subjective TMJ complaints(sounds and pain) before and one-week after the Pumping treatment. Vibration related items included total integral, high integral, low integral, ratio of high integral to low integral, peak amplitude, peak frequency and median frquency. 1. It was not statistically significant between the acute and chronic groups before the treatment. However, total integral, high integral, low integral, peak amplitude, peak frequency, median frequency showed to be greater in the chronic group. 2. In all the subjects, just after the Pumping treatment was done, total integral, high and low integral, peak amplitude and peak frequency significantly decreased (p<0.05). Even after one week, low integral, peak frequency and median frequency significantly decreased (p<0,05), and the TMJ sound diminished accordingly. 3. Comparing the two groups(before and right after the Pumping treatment), there was the following difference ; in the acute group, high integral, high amplitude, high frequency and median frequency significantly decreased(p<0.05). In the chronic group, total integral, high integral, low integral, ratio, peak amplitude and peak frequency significantly decreased(p<0,05). It was not statistically significant between the acute and chronic group. 4. Comparing the two groups(right after and one week after the Pumping treatment), there was the following difference : in the acute group, high integral, high amplitude, high frequency and median frequency significantly decreased(p<0.05), In the chronic group, low integral significantly decreased(p<0.05). However, although it was not statistically significant, after one week, there was an increase in total integral, ratio, peak amplitude and peak frequency compared to right after the treatment group. 5. In the VAS of before and one week after the Pumping treatment of the TMJ pain and sound, the TMJ pain significantly decreased(p<0.05) in both the acute and chronic group. However, it was not statistically significant between the two groups. There was a statistically significant decrease(p<0.05) in the TMJ sound in the acute group after one week of Pumping treatment, but no change was notable in the chronic group and it was not statistically significant between the two groups. From the above results, we can conclude that Pumping into the upper joint cavity of patients having reducible disc displacement is effective in reducing clicking and pain. Therefore, it can be applied in diverse clinical fields.

  • PDF

The Effects of a Mupirocin Smear in the Nasal Cavity Against Nosocomial Infections (비강 내 약물 도포가 병원 감염 예방에 미치는 효과)

  • Kil Suk-Young
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.6 no.2
    • /
    • pp.255-266
    • /
    • 1999
  • This study was done to analyze the effects of a smear in the nasal cavity against nosocomial Infection. The smear used was mupirocin, and the study centered on infection which constitutes the majority of nosocomial infections called MRSA. The data were collected between March 23 1998 and June 31 of the same year in a university hospital in the Kyongi Province, and is made up of a experimental group of 14 patients who were given nasal cavity smears and a control group of 16 patients who were not given nasal cavity smears. The data were analyzed through frequency and the Chi-square tests and gave forth these results. 1. Of the experimental group 28.6% developed nosocomial infections while 62.5% of the control group developed infections. This difference was significant. 2. In the experimental group, all of the patients developed infections within the first week in the ICU, while 80% of the control group developed infections in the first week and 20% in the second week. The difference was not as marked here. 3. In the experimental group the DM group 66.7% contracted MRSA while 18.2% developed it in the non-DM group showing that the DM group had infection rate was 3.7 times higher than the non-DM groups. In the control group the DM group had a 100% infection rate while 50% of the non-DM group developed it. Overall the DM group's rate infection was 2.4 times higher than the non-DM group. 4. In the experimental group, 37.55% of the patients who had a tracheostomy developed it while 16.7% of the patients who did not have a tracheostomy developed infections. In the control group, 62.5% of the patients who had tracheostomy, and 37.5% of the patients who did not have tracheostomies developed infections. Those who had tracheostomies, and the control group had double the rate contracting infections. From these results we can see that nasal cavity smears are effective against nosocomial infections. In spite of the smears, patients with the diabetes mellitus had a high MRSA infection rate, which requires new alternative treatments.

  • PDF